Christian Knipfer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christian Knipfer has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Werner Adler
Institute of Medical Informatics, Biometry and Epidemiology (IMBE) of the Friedrich-Alexander-University, Erlangen-Nuremberg, Waldstrasse 6, 91054 Erlangen, Germany
4 shared publications Abbas Agaimy
Department of Pathology, Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
2 shared publications- Andreas Braeuer
Technische Universität Bergakademie Freiberg Leipziger Str. 28
2 shared publications Florian Stelzle
Department of Oral and Maxillofacial Surgery, Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Erlangen, Germany ; Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
2 shared publications- Florian Stelzle
Erlangen Graduate School in Advanced Optical Technologies, 91052 Erlangen, Germany
2 shared publications Friedrich Wilhelm Neukam
Department of Oral and Maxillofacial Surgery, Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Erlangen, Germany ; Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
2 shared publications
Latest Publications
- Open Access
- 3 June 2016
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 14 (1) , 1-11
Development and validation of a classification and scoring system for the diagnosis of oral squamous cell carcinomas through confocal laser endomicroscopy
Confocal laser endomicroscopy (CLE) is an optical biopsy method allowing in vivo microscopic imaging at 1000-fold magnification. It was the aim to evaluate CLE in the human oral cavity for the differentiation of physiological/carcinomatous mucosa and to establish and validate, for the first time, a scoring system to facilitate CLE assessment. The study consisted of 4 phases: (1) CLE-imaging (in vivo) was performed after the intravenous injection of fluorescein in patients with histologically confirmed carcinomatous oral mucosa; (2) CLE-experts (n = 3) verified the applicability of CLE in the oral cavity for the differentiation between physiological and cancerous tissue compared to the gold standard of histopathological assessment; (3) based on specific patterns of tissue changes, CLE-experts (n = 3) developed a classification and scoring system (DOC-Score) to simplify the diagnosis of oral squamous cell carcinomas; (4) validation of the newly developed DOC-Score by non-CLE-experts (n = 3); final statistical evaluation of their classification performance (comparison to the results of CLE-experts and the histopathological analyses). Experts acquired and edited 45 sequences (260 s) of physiological and 50 sequences (518 s) of carcinomatous mucosa (total: 95 sequences/778 s). All sequences were evaluated independently by experts and non-experts (based on the newly proposed classification system). Sensitivity (0.953) and specificity (0.889) of the diagnoses by experts as well as sensitivity (0.973) and specificity (0.881) of the non-expert ratings correlated well with the results of the present gold standard of tissue histopathology. Experts had a positive predictive value (PPV) of 0.905 and a negative predictive value (NPV) of 0.945. Non-experts reached a PPV of 0.901 and a NPV of 0.967 with the help of the DOC-Score. Inter-rater reliability (Fleiss` kappa) was 0.73 for experts and 0.814 for non-experts. The intra-rater reliability (Cronbach’s alpha) of the experts was 0.989 and 0.884 for non-experts. CLE is a suitable and valid method for experts to diagnose oral cancer. Using the DOC-Score system, an accurate chair-side diagnosis of oral cancer is feasible with comparable results to the gold standard of histopathology—even in daily clinical practice for non-experienced raters.
- 3 June 2016
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 14 (1) , 1-11
Open AccessDevelopment and validation of a classification and scoring system for the diagnosis of oral squamous cell carcinomas through confocal laser endomicroscopy
Confocal laser endomicroscopy (CLE) is an optical biopsy method allowing in vivo microscopic imaging at 1000-fold magnification. It was the aim to evaluate CLE in the human oral cavity for the differentiation of physiological/carcinomatous mucosa and to establish and validate, for the first time, a scoring system to facilitate CLE assessment. The study consisted of 4 phases: (1) CLE-imaging (in vivo) was performed after the intravenous injection of fluorescein in patients with histologically confirmed carcinomatous oral mucosa; (2) CLE-experts (n = 3) verified the applicability of CLE in the oral cavity for the differentiation between physiological and cancerous tissue compared to the gold standard of histopathological assessment; (3) based on specific patterns of tissue changes, CLE-experts (n = 3) developed a classification and scoring system (DOC-Score) to simplify the diagnosis of oral squamous cell carcinomas; (4) validation of the newly developed DOC-Score by non-CLE-experts (n = 3); final statistical evaluation of their classification performance (comparison to the results of CLE-experts and the histopathological analyses). Experts acquired and edited 45 sequences (260 s) of physiological and 50 sequences (518 s) of carcinomatous mucosa (total: 95 sequences/778 s). All sequences were evaluated independently by experts and non-experts (based on the newly proposed classification system). Sensitivity (0.953) and specificity (0.889) of the diagnoses by experts as well as sensitivity (0.973) and specificity (0.881) of the non-expert ratings correlated well with the results of the present gold standard of tissue histopathology. Experts had a positive predictive value (PPV) of 0.905 and a negative predictive value (NPV) of 0.945. Non-experts reached a PPV of 0.901 and a NPV of 0.967 with the help of the DOC-Score. Inter-rater reliability (Fleiss` kappa) was 0.73 for experts and 0.814 for non-experts. The intra-rater reliability (Cronbach’s alpha) of the experts was 0.989 and 0.884 for non-experts. CLE is a suitable and valid method for experts to diagnose oral cancer. Using the DOC-Score system, an accurate chair-side diagnosis of oral cancer is feasible with comparable results to the gold standard of histopathology—even in daily clinical practice for non-experienced raters.
- Open Access
Does Laser Surgery Interfere with Optical Nerve Identification in Maxillofacial Hard and Soft Tissue?—An Experimental Ex Vivo Study
The protection of sensitive structures (e.g., nerves) from iatrogenic damage is of major importance when performing laser surgical procedures. Especially in the head and neck area both function and esthetics can be affected to a great extent. Despite its many benefits, the surgical utilization of a laser is therefore still limited to superficial tissue ablation. A remote feedback system which guides the laser in a tissue-specific way would provide a remedy. In this context, it has been shown that nerval structures can be specifically recognized by their optical diffuse reflectance spectra both before and after laser ablation. However, for a translation of these findings to the actual laser ablation process, a nerve protection within the laser pulse is of utmost significance. Thus, it was the aim of the study to evaluate, if the process of Er:YAG laser surgery—which comes with spray water cooling, angulation of the probe (60°) and optical process emissions—interferes with optical tissue differentiation. For the first time, no stable conditions but the ongoing process of laser tissue ablation was examined. Therefore, six different tissue types (nerve, skin, muscle, fat, cortical and cancellous bone) were acquired from 15 pig heads. Measurements were performed during Er:YAG laser ablation. Diffuse reflectance spectra (4500, wavelength range: 350–650 nm) where acquired. Principal component analysis (PCA) and quadratic discriminant analysis (QDA) were calculated for classification purposes. The clinical highly relevant differentiation between nerve and bone was performed correctly with an AUC of 95.3% (cortial bone) respectively 92.4% (cancellous bone). The identification of nerve tissue against the biological very similar fat tissue yielded good results with an AUC value of 83.4% (sensitivity: 72.3%, specificity: of 82.3%). This clearly demonstrates that nerve identification by diffuse reflectance spectroscopy works reliably in the ongoing process of laser ablation in spite of the laser beam, spray water cooling and the tissue alterations entailed by tissue laser ablation. This is an essential step towards a clinical utilization.
Open AccessDoes Laser Surgery Interfere with Optical Nerve Identification in Maxillofacial Hard and Soft Tissue?—An Experimental Ex Vivo Study
The protection of sensitive structures (e.g., nerves) from iatrogenic damage is of major importance when performing laser surgical procedures. Especially in the head and neck area both function and esthetics can be affected to a great extent. Despite its many benefits, the surgical utilization of a laser is therefore still limited to superficial tissue ablation. A remote feedback system which guides the laser in a tissue-specific way would provide a remedy. In this context, it has been shown that nerval structures can be specifically recognized by their optical diffuse reflectance spectra both before and after laser ablation. However, for a translation of these findings to the actual laser ablation process, a nerve protection within the laser pulse is of utmost significance. Thus, it was the aim of the study to evaluate, if the process of Er:YAG laser surgery—which comes with spray water cooling, angulation of the probe (60°) and optical process emissions—interferes with optical tissue differentiation. For the first time, no stable conditions but the ongoing process of laser tissue ablation was examined. Therefore, six different tissue types (nerve, skin, muscle, fat, cortical and cancellous bone) were acquired from 15 pig heads. Measurements were performed during Er:YAG laser ablation. Diffuse reflectance spectra (4500, wavelength range: 350–650 nm) where acquired. Principal component analysis (PCA) and quadratic discriminant analysis (QDA) were calculated for classification purposes. The clinical highly relevant differentiation between nerve and bone was performed correctly with an AUC of 95.3% (cortial bone) respectively 92.4% (cancellous bone). The identification of nerve tissue against the biological very similar fat tissue yielded good results with an AUC value of 83.4% (sensitivity: 72.3%, specificity: of 82.3%). This clearly demonstrates that nerve identification by diffuse reflectance spectroscopy works reliably in the ongoing process of laser ablation in spite of the laser beam, spray water cooling and the tissue alterations entailed by tissue laser ablation. This is an essential step towards a clinical utilization.
- Open Access
- 24 June 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (7) , 2675
Raman difference spectroscopy: a non-invasive method for identification of oral squamous cell carcinoma: publisher’s note
The author list appeared incorrectly in [Biomed. Opt. Express 5(9), 3252–3265 (2014)]. The author names were corrected online as of January 17, 2015: https://www.osapublishing.org/boe/cfm?uri=boe-5-9-3252.
- 24 June 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (7) , 2675
Open AccessRaman difference spectroscopy: a non-invasive method for identification of oral squamous cell carcinoma: publisher’s note
The author list appeared incorrectly in [Biomed. Opt. Express 5(9), 3252–3265 (2014)]. The author names were corrected online as of January 17, 2015: https://www.osapublishing.org/boe/cfm?uri=boe-5-9-3252.
- Open Access
- 28 August 2014
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 5 (9) , 3252-3265
Raman difference spectroscopy: a non-invasive method for identification of oral squamous cell carcinoma
The feasibility of shifted-excitation Raman difference spectroscopy (SERDS) as a label-free and non-invasive technique for an objective diagnosis of oral cancer (OSCC) was investigated by analyzing 12 ex vivo OSCC samples. 72 mean SERDS spectra from each three physiological tissue points and pathological lesions were correlated with the histo-pathological diagnosis. Principal component analysis (PCA) and linear discriminant analysis (LDA) showed excellent results with an area under the curve of 94.5% and a classification error of 9.7% (sensitivity: 86.1%; specificity: 94.4%). The SERDS Raman spectra of malignant and benignant tissues were discriminable with respect to the spectral features of proteins, lipids and nucleic acids. The presented method is capable of a highly accurate identification of OSCC. These findings suggest a high validity and reproducibility of SERDS combined with PCA and LDA analysis regarding oral cancer tissue.
- 28 August 2014
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 5 (9) , 3252-3265
Open AccessRaman difference spectroscopy: a non-invasive method for identification of oral squamous cell carcinoma
The feasibility of shifted-excitation Raman difference spectroscopy (SERDS) as a label-free and non-invasive technique for an objective diagnosis of oral cancer (OSCC) was investigated by analyzing 12 ex vivo OSCC samples. 72 mean SERDS spectra from each three physiological tissue points and pathological lesions were correlated with the histo-pathological diagnosis. Principal component analysis (PCA) and linear discriminant analysis (LDA) showed excellent results with an area under the curve of 94.5% and a classification error of 9.7% (sensitivity: 86.1%; specificity: 94.4%). The SERDS Raman spectra of malignant and benignant tissues were discriminable with respect to the spectral features of proteins, lipids and nucleic acids. The presented method is capable of a highly accurate identification of OSCC. These findings suggest a high validity and reproducibility of SERDS combined with PCA and LDA analysis regarding oral cancer tissue.