CVCristian Vulcu

Cristian Vulcu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cristian Vulcu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 11.13: Hybrid seismic protection system: Buckling restrained brace of nano-micro composite magneto rheological damper

    by Cristian Vulcu, Dan Dubină, Nicolae Popa, Ladislau Vekas, Gheorghe Ghiţă, Tudor Sireteanu, Istvan Borbath, Radu Oprescu


  • Beam-to-CFT High-Strength Joints with External Diaphragm. II: Numerical Simulation of Joint Behavior

    by Cristian Vulcu, Aurel Stratan, Adrian Ciutina, Dan Dubina

    The paper presents the outcome of a finite-element numerical investigation program developed and carried out in connection to a set of experimental investigations performed on welded beam-to-column joints, with columns realized as concrete-filled tubes (CFT) with rectangular hollow sections (RHS). The current study was aimed to calibrate a set of numerical models, to conduct a parametric study, and to validate the proposed design procedure. Joint models were calibrated, and additional parameters were investigated numerically, such as: influence of the concrete core, influence of the axial force in the column, response of one-way and two-way joints. It was shown that (1) the influence of concrete core was proved to be low for the single sided RBS or CP joint assemblies, but significant corresponding to joints with strengthened beam, (2) the response of the joint assembly was not affected by the presence of the axial compression force in the column, and (3) the connection solution with external diaphragms was characterized by an adequate response considering one-way and two-way joints. The current study evidenced a good conception and design of the reduced beam section (RBS) and cover plate (CP) joints. In particular, the study proved the feasibility of using higher steel grades in columns and joint components, and the use of an external diaphragm for the transfer the loads from the beam to the side walls of the rectangular hollow section (RHS) steel tube.


  • Beam-to-CFT High-Strength Joints with External Diaphragm. I: Design and Experimental Validation

    by Cristian Vulcu, Aurel Stratan, Adrian Ciutina, Dan Dubina

    The paper presents the outcomes of an experimental program developed and carried out with the aim of characterizing the behavior of two types of moment-resisting joints in multistory frames of concrete-filled high-strength steel rectangular hollow section (RHS) columns and mild carbon steel beams. The paper describes the design approach and displays the specific detailing for the two joint typologies: with reduced beam section (RBS) and with cover plates (CP). In spite of the various past and recent studies which were focused on the evaluation of full-strength welded beam-to-concrete-filled-tube (CFT) column joints, particular design procedures are missing at the European level. The objectives of the current research were to (1) development a design procedure for welded beam-to-CF-RHS joints, (2) experimental validation of the of the design procedure, and (3) assessment of the seismic performance. The monotonic and cyclic tests evidenced a good conception and design of the RBS and CP joints. In particular, the current study proved the feasibility of using higher steel grades in columns and joint components, and the use of an external diaphragm for the transfer the loads from the beam to the side walls of the RHS steel tube. The seismic performance of the joints was proved adequate, the joints sustaining rotation capacities larger than the 40 mrad at the significant damage performance level.


  • Open Access

    Numerical Model of a Hybrid Damping System Composed of a Buckling Restrained Brace with a Magneto Rheological Damper

    by Norin Filip-Vacarescu, Cristian Vulcu, Dan Dubina

    This paper discusses the concept of a hybrid damper made from a combination of two dissipative devices. A passive hysteretic device like steel Buckling Restrained Brace (BRB) can be combined with a magneto-rheological (MR) Fluid Damper in order to obtain a hybrid dissipative system. This system can work either as a semi-active system, if the control unit is available, or as a passive system, tuned for working according to performance based seismic engineering (PBSE) scale of reference parameters (i.e. interstory drift).


  • High strength steel in seismic resistant building frames

    by Dan Dubina, Aurel Stratan, Cristian Vulcu, Adrian Ciutina

    Seismic resistant building frames designed as dissipative structures, must allow for plastic deformations to develop in specific members, whose behaviour is expected to be predicted and controlled by proper calculation and detailing. Members designed to remain elastic during earthquake, such as columns, are characterized by high strength demands. Dual‐steel structural systems, optimized according to a Performance Based Design (PBD) philosophy, in which High Strength Steel (HSS) is used in predominantly “elastic” members, while Mild Carbon Steel (MCS) is used in dissipative members, can be very reliable and cost efficient. Because present seismic design codes do not cover this specific configuration, an extensive European research project [1], HSS‐SERF − High Strength Steel in Seismic Resistant Building Frames, was carried out with the aim to investigate and evaluate the seismic performance of dual‐steel building frames. On this purpose, and based on a large numerical and experimental program, the following objectives have been focused into the project:1. to find reliable structural typologies and joint/connection detailing for dual‐steel building frames, (e. g. of HSS and MCS members), and to validate them by tests and advanced numerical simulations,2. to develop design criteria and performance based design methodology for dual‐steel structures using high strength steel,3. to recommend relevant design parameters (i. e. behaviour factor q, overstrength factor Ω) to be implemented in further versions of the seismic design code, EN 1998‐1 [1], in order to apply capacity design approach for dual‐steel framing typologies,4. to evaluate technical and economic benefit of dual‐steel approach involving HSS.