Kate Liddle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kate Liddle has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jenni M. Buckley
Department of Mechanical Engineering, University of Delaware, Newark, Delaware
2 shared publications - Amir Matitiyahu
Orthopaedic Trauma Institute (OTI), San Francisco General Hospital, University of California, San Francisco (UCSF), 2550 23rd Street, Building 9, 2nd Floor, 94110, San Francisco, CA USA
1 shared publication - Amir Matityahu
Department of Orthopaedic Surgery, Orthopaedic Trauma Institute, University of California San Francisco, San Francisco, CA 94110, USA
1 shared publication - Meir Marmor
Orthopaedic Trauma Institute, San Francisco General Hospital, University of California, San Francisco, 2550 23rd Street, Building 9, 2nd Floor, San Francisco, CA 94110, USA
1 shared publication - Meir Tibrin Marmor
University of California, San Francisco
1 shared publication
Latest Publications
- 27 April 2016
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 26 (4) , 379-383
Effect of varus and valgus alignment on implant loading after proximal femur fracture fixation
Introduction More than 10 % of proximal femur fractures repaired with either a sliding hip screw and side plate (SHS-P) or a sliding hip screw and intramedullary nail (SHS-IMN) demonstrate varus malreduction. The purpose of this study was to compare the effect of varus or valgus loading on comminuted intertrochanteric fractures repaired with SHS-P or SHS-IMN constructs. Methods Unstable intertrochanteric fractures with segmental comminution were generated in 12 cadaver proximal femurs, six of which were fixed with an SHS-P and six with an SHS-IMN. Both implants had a strain gauge at the lag screw-nail–plate interface to assess implant load bearing. The load on the implants was measured with the specimens in neutral position and at 5°, 10°, and 15° of varus and valgus. Results Loads on both SHS-IMN and SHS-P constructs were significantly increased when loading the implants in varus and significantly decreased when loading the implants in valgus. Unlike the SHS-IMN, the SHS-P trended toward increased load bearing at 15° varus (159.1 vs. 118.5 %, P = .065) and trended toward less load bearing at 15° valgus (42.3 vs. 59.8 %, P = .06). Conclusions: Regardless of implant choice, avoiding varus loading on the fixation construct reduces the load on the implant. SHS-P constructs may be more affected by varus or valgus malalignment than SHS-IMN constructs.
- 27 April 2016
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 26 (4) , 379-383
Effect of varus and valgus alignment on implant loading after proximal femur fracture fixation
Introduction More than 10 % of proximal femur fractures repaired with either a sliding hip screw and side plate (SHS-P) or a sliding hip screw and intramedullary nail (SHS-IMN) demonstrate varus malreduction. The purpose of this study was to compare the effect of varus or valgus loading on comminuted intertrochanteric fractures repaired with SHS-P or SHS-IMN constructs. Methods Unstable intertrochanteric fractures with segmental comminution were generated in 12 cadaver proximal femurs, six of which were fixed with an SHS-P and six with an SHS-IMN. Both implants had a strain gauge at the lag screw-nail–plate interface to assess implant load bearing. The load on the implants was measured with the specimens in neutral position and at 5°, 10°, and 15° of varus and valgus. Results Loads on both SHS-IMN and SHS-P constructs were significantly increased when loading the implants in varus and significantly decreased when loading the implants in valgus. Unlike the SHS-IMN, the SHS-P trended toward increased load bearing at 15° varus (159.1 vs. 118.5 %, P = .065) and trended toward less load bearing at 15° valgus (42.3 vs. 59.8 %, P = .06). Conclusions: Regardless of implant choice, avoiding varus loading on the fixation construct reduces the load on the implant. SHS-P constructs may be more affected by varus or valgus malalignment than SHS-IMN constructs.
- 14 October 2014
- Published by ASME International in Journal of Medical Devices
- Vol. 8 (4) , 044508
A New Method to Intra-Operatively Measure Local Bone Strength in Osteoporotic Bone Using a Modified Surgical Tool
The aim of this study was to test a novel method for intra-operative assessment of osteoporotic bone fracture strength using a surgical tool instrumented with a strain gauge and compare the device with cortical width (CW) measurements in the distal radius. The force needed to puncture the cortex (FNP) was quantified with the device and found to strongly correlate with bone mineral density (BMD) in the diaphysis (adj. R2 = 0.66, p < 0.001). Screw pullout studies were performed and correlation between FNP and screw pullout strength (SPS) was modest (adj. R2 = 0.34 with p < 0.05). CW correlated well with BMD (adj. R2 = 0.7, p < 0.0001) and SPS (adj. R2 = 0.5, p = 0.002) in the diaphysis. This technology may allow objective intra-operative assessment of bone strength to provide surgeons another tool for decision making on fixation strategies appropriate to the area of bone treated.
- 14 October 2014
- Published by ASME International in Journal of Medical Devices
- Vol. 8 (4) , 044508
A New Method to Intra-Operatively Measure Local Bone Strength in Osteoporotic Bone Using a Modified Surgical Tool
The aim of this study was to test a novel method for intra-operative assessment of osteoporotic bone fracture strength using a surgical tool instrumented with a strain gauge and compare the device with cortical width (CW) measurements in the distal radius. The force needed to puncture the cortex (FNP) was quantified with the device and found to strongly correlate with bone mineral density (BMD) in the diaphysis (adj. R2 = 0.66, p < 0.001). Screw pullout studies were performed and correlation between FNP and screw pullout strength (SPS) was modest (adj. R2 = 0.34 with p < 0.05). CW correlated well with BMD (adj. R2 = 0.7, p < 0.0001) and SPS (adj. R2 = 0.5, p = 0.002) in the diaphysis. This technology may allow objective intra-operative assessment of bone strength to provide surgeons another tool for decision making on fixation strategies appropriate to the area of bone treated.