KLKate Liddle

Kate Liddle

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kate Liddle has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of varus and valgus alignment on implant loading after proximal femur fracture fixation

    by Meir Marmor, Kate Liddle, Jenni Buckley, Amir Matityahu

    Introduction More than 10 % of proximal femur fractures repaired with either a sliding hip screw and side plate (SHS-P) or a sliding hip screw and intramedullary nail (SHS-IMN) demonstrate varus malreduction. The purpose of this study was to compare the effect of varus or valgus loading on comminuted intertrochanteric fractures repaired with SHS-P or SHS-IMN constructs. Methods Unstable intertrochanteric fractures with segmental comminution were generated in 12 cadaver proximal femurs, six of which were fixed with an SHS-P and six with an SHS-IMN. Both implants had a strain gauge at the lag screw-nail–plate interface to assess implant load bearing. The load on the implants was measured with the specimens in neutral position and at 5°, 10°, and 15° of varus and valgus. Results Loads on both SHS-IMN and SHS-P constructs were significantly increased when loading the implants in varus and significantly decreased when loading the implants in valgus. Unlike the SHS-IMN, the SHS-P trended toward increased load bearing at 15° varus (159.1 vs. 118.5 %, P = .065) and trended toward less load bearing at 15° valgus (42.3 vs. 59.8 %, P = .06). Conclusions: Regardless of implant choice, avoiding varus loading on the fixation construct reduces the load on the implant. SHS-P constructs may be more affected by varus or valgus malalignment than SHS-IMN constructs.


  • A New Method to Intra-Operatively Measure Local Bone Strength in Osteoporotic Bone Using a Modified Surgical Tool

    by Kate Liddle, Jenni M. Buckley, Amir Matitiyahu, Meir Marmor

    The aim of this study was to test a novel method for intra-operative assessment of osteoporotic bone fracture strength using a surgical tool instrumented with a strain gauge and compare the device with cortical width (CW) measurements in the distal radius. The force needed to puncture the cortex (FNP) was quantified with the device and found to strongly correlate with bone mineral density (BMD) in the diaphysis (adj. R2 = 0.66, p < 0.001). Screw pullout studies were performed and correlation between FNP and screw pullout strength (SPS) was modest (adj. R2 = 0.34 with p < 0.05). CW correlated well with BMD (adj. R2 = 0.7, p < 0.0001) and SPS (adj. R2 = 0.5, p = 0.002) in the diaphysis. This technology may allow objective intra-operative assessment of bone strength to provide surgeons another tool for decision making on fixation strategies appropriate to the area of bone treated.