HAHaktan Altinova

Haktan Altinova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Haktan Altinova has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Host Response Impairs Tissue Integration of a Fibrin Hydrogel Scaffold Containing Poly(ε-caprolactone) Nanofibers for Peripheral Nerve Repair

    by Haktan Altinova, Dorothee Hodde, José L. Gerardo-Nava, Axel Dievernich, Lmar Arman, Melissa Büchler, Andreas Kriebel, Jörg Mey, Hans Clusmann, Joachim Weis, et al.

    The development of bioengineered conduits for the repair of large peripheral nerve defects remains challenging. Here, we introduce a biomimetic fibrin hydrogel scaffold containing stacked arrays of aligned poly(ε-caprolactone) (PCL) nanofibers that mimics the naturally forming fibrin cable seen in transection injuries. We further evaluated the additional encapsulation of Schwann cells (SCs) into the fibrin hydrogel. Nerve regeneration was examined in a 15 mm rat sciatic nerve resection model over a period of 12 weeks, comparing our scaffolds against the autograft, a collagen hollow tube, and a lesion-only control group. Functional and morphometric analyses revealed that the autograft supported the strongest regeneration, followed by the SC-seeded fibrin-nanofiber scaffold and the hollow tube. Unexpectedly, a macrophage-rich core devoid of SCs and regenerated axons formed within both fibrin-nanofiber scaffolds around persisting PCL nanofibers. This core impaired the regenerative potential of the non-SC-seeded fibrin-nanofiber scaffold to the extent that functional regeneration was comparable to that of the lesion-only control group. While the scaffolds were designed to closely mimic and support the natural regenerative environment following nerve transection, our results reveal that these theoretical considerations do not necessarily translate into practice.

  • Open Access

    Characterization of a Novel Aspect of Tissue Scarring Following Experimental Spinal Cord Injury and the Implantation of Bioengineered Type-I Collagen Scaffolds in the Adult Rat: Involvement of Perineurial-like Cells?

    by Haktan Altinova, Pascal Achenbach, Moniek Palm, Istvan Katona, Emmanuel Hermans, Hans Clusmann, Joachim Weis, Gary Anthony Brook

    Numerous intervention strategies have been developed to promote functional tissue repair following experimental spinal cord injury (SCI), including the bridging of lesion-induced cystic cavities with bioengineered scaffolds. Integration between such implanted scaffolds and the lesioned host spinal cord is critical for supporting regenerative growth, but only moderate-to-low degrees of success have been reported. Light and electron microscopy were employed to better characterise the fibroadhesive scarring process taking place after implantation of a longitudinally microstructured type-I collagen scaffold into unilateral mid-cervical resection injuries of the adult rat spinal cord. At long survival times (10 weeks post-surgery), sheets of tightly packed cells (of uniform morphology) could be seen lining the inner surface of the repaired dura mater of lesion-only control animals, as well as forming a barrier along the implant–host interface of the scaffold-implanted animals. The highly uniform ultrastructural features of these scarring cells and their anatomical continuity with the local, reactive spinal nerve roots strongly suggest their identity to be perineurial-like cells. This novel aspect of the cellular composition of reactive spinal cord tissue highlights the increasingly complex nature of fibroadhesive scarring involved in traumatic injury, and particularly in response to the implantation of bioengineered collagen scaffolds.


  • A novel in vitro assay for peripheral nerve-related cell migration that preserves both extracellular matrix-derived molecular cues and nanofiber-derived topography

    by Pascal Achenbach, Inge Hambeukers, Anna L. Pierling, José L. Gerardo-Nava, Laura Hillerbrand, Antonio S. Sechi, Katharina J. Glücks, Paul D. Dalton, Andrij Pich, Axel Dievernich, et al.


  • Dense fibroadhesive scarring and poor blood vessel-maturation hamper the integration of implanted collagen scaffolds in an experimental model of spinal cord injury

    by Haktan Altinova, Sebastian Hammes, Moniek Palm, Pascal Achenbach, Jose Gerardo-Nava, Ronald Deumens, Tobias Führmann, Sabien G A van Neerven, Emmanuel Hermans, Joachim Weis, et al.

    Severe spinal cord injury (SCI) results in permanent functional deficits, which despite pre-clinical advances, remain untreatable. Combinational approaches, including the implantation of bioengineered scaffolds are likely to promote significant tissue repair. However, this critically depends on the extent to which host tissue can integrate with the implant. In the present paper, blood vessel formation and maturation were studied within and around implanted micro-structured type-I collagen scaffolds at 10 weeks post implantation in adult rat mid-cervical spinal cord lateral funiculotomy injuries. Morphometric analysis revealed that blood vessel density within the scaffold was similar to that of the lateral white matter tracts that the implant replaced. However, immunohistochemistry for zonula occludens −1 (ZO-1) and endothelial barrier antigen revealed that scaffold microvessels remained largely immature, suggesting poor blood-spinal cord barrier (BSB) reformation. Furthermore, a band of intense ZO-1-immunoreactive fibroblast-like cells isolated the implant. Spinal cord vessels outside the ZO-1-band demonstrated BSB-formation, while vessels within the scaffold generally did not. The formation of a double-layered fibrotic and astroglial scar around the collagen scaffold might explain the relatively poor implant-host integration and suggests a mechanism for failed microvessel maturation. Targeted strategies that improve implant-host integration for such biomaterials will be vital for future tissue engineering and regenerative medicine approaches for traumatic SCI.


  • Open Access

    Fibroadhesive scarring of grafted collagen scaffolds interferes with implant–host neural tissue integration and bridging in experimental spinal cord injury

    by Haktan Altinova, Sebastian Hammes, Moniek Palm, Jose Gerardo-Nava, Pascal Achenbach, Ronald Deumens, Emmanuel Hermans, Tobias Führmann, Arne Boecker, Sabien Geraldine Antonia van Neerven, et al.

    Severe traumatic spinal cord injury (SCI) results in a devastating and permanent loss of function, and is currently an incurable condition. It is generally accepted that future intervention strategies will require combinational approaches, including bioengineered scaffolds, to support axon growth across tissue scarring and cystic cavitation. Previously, we demonstrated that implantation of a microporous type-I collagen scaffold into an experimental model of SCI was capable of supporting functional recovery in the absence of extensive implant–host neural tissue integration. Here, we demonstrate the reactive host cellular responses that may be detrimental to neural tissue integration after implantation of collagen scaffolds into unilateral resection injuries of the adult rat spinal cord. Immunohistochemistry demonstrated scattered fibroblast-like cell infiltration throughout the scaffolds as well as the presence of variable layers of densely packed cells, the fine processes of which extended along the graft–host interface. Few reactive astroglial or regenerating axonal profiles could be seen traversing this layer. Such encapsulation-type behaviour around bioengineered scaffolds impedes the integration of host neural tissues and reduces the intended bridging role of the implant. Characterization of the cellular and molecular mechanisms underpinning this behaviour will be pivotal in the future design of collagen-based bridging scaffolds intended for regenerative medicine.


  • Open Access

    Clinical and biometrical 12-month follow-up in patients after reconstruction of the sural nerve biopsy defect by the collagen-based nerve guide Neuromaix

    by Ahmet Bozkurt, Kristl G. Claeys, Simone Schrading, Jana V. Rödler, Haktan Altinova, Jörg B. Schulz, Joachim Weis, Norbert Pallua, Sabien G. A. van Neerven

    Many new strategies for the reconstruction of peripheral nerve injuries have been explored for their effectiveness in supporting nerve regeneration. However only a few of these materials were actually clinically evaluated and approved for human use. This open, mono-center, non-randomized clinical study summarizes the 12-month follow-up of patients receiving reconstruction of the sural nerve biopsy defect by the collagen-based nerve guide Neuromaix. Neuromaix was implanted as a micro-structured, two-component scaffold bridging 20–40 mm nerve defects after sural nerve biopsy in twenty patients (eighteen evaluated, two lost in follow-up). Safety of the material was evaluated by clinical examination of wound healing. Performance was assessed by sensory testing of modalities, pain assessment, and palpation for the Hoffmann–Tinel’s sign as well as demarcating the asensitive area at each follow-up visit. Every patient demonstrated uneventful wound healing during the complete 12-month time course of the study. Two patients reported complete return of sensation, whereas eleven out of eighteen patients reported a positive Hoffmann–Tinel’s sign at the lower leg with simultaneous reduction of the asensitive area by 12 months. Our data show that Neuromaix can be implanted safely in humans to bridge sural nerve gaps. No procedure-related, adverse events, or severe adverse events were reported. These first clinical data on Neuromaix provide promising perspectives for the bridging of larger nerve gaps in combined nerves, which should be investigated more through extensive, multi-center clinical trials in the near future.


  • Functional recovery not correlated with axon regeneration through olfactory ensheathing cell-seeded scaffolds in a model of acute spinal cord injury

    by Haktan Altinova, Sven Möllers, Ronald Deumens, Jose Gerardo-Nava, Tobias Führmann, Sabien Geraldine Antonia van Neerven, Ahmet Bozkurt, Christian Andreas Mueller, Hans Joachim Hoff, Ingo Heschel, et al.

    The implantation of bioengineered scaffolds into lesion-induced gaps of the spinal cord is a promising strategy for promoting functional tissue repair because it can be combined with other intervention strategies. Our previous investigations showed that functional improvement following the implantation of a longitudinally microstructured collagen scaffold into unilateral mid-cervical spinal cord resection injuries of adult Lewis rats was associated with only poor axon regeneration within the scaffold. In an attempt to improve graft-host integration as well as functional recovery, scaffolds were seeded with highly enriched populations of syngeneic, olfactory bulb-derived ensheathing cells (OECs) prior to implantation into the same lesion model. Regenerating neurofilament-positive axons closely followed the trajectory of the donor OECs, as well as that of the migrating host cells within the scaffold. However, there was only a trend for increased numbers of regenerating axons above that supported by non-seeded scaffolds or in the untreated lesions. Nonetheless, significant functional recovery in skilled forelimb motor function was observed following the implantation of both seeded and non-seeded scaffolds which could not be correlated to the extent of axon regeneration within the scaffold. Mechanisms other than simple bridging of axon regeneration across the lesion must be responsible for the improved motor function.


  • Characterisation of cell–substrate interactions between Schwann cells and three‐dimensional fibrin hydrogels containing orientated nanofibre topographical cues

    by Dorothee Hodde, José Gerardo-Nava, Vanessa Wöhlk, Stefan Weinandy, Stefan Jockenhövel, Andreas Kriebel, Haktan Altinova, Harry W M Steinbusch, Martin Möller, Joachim Weis, et al.

    The generation of complex three‐dimensional bioengineered scaffolds that are capable of mimicking the molecular and topographical cues of the extracellular matrix found in native tissues is a field of expanding research. The systematic development of such scaffolds requires the characterisation of cell behaviour in response to the individual components of the scaffold. In the present investigation, we studied cell–substrate interactions between purified populations of Schwann cells and three‐dimensional fibrin hydrogel scaffolds, in the presence or absence of multiple layers of highly orientated electrospun polycaprolactone nanofibres. Embedded Schwann cells remained viable within the fibrin hydrogel for up to 7 days (the longest time studied); however, cell behaviour in the hydrogel was somewhat different to that observed on the two‐dimensional fibrin substrate: Schwann cells failed to proliferate in the fibrin hydrogel, whereas cell numbers increased steadily on the two‐dimensional fibrin substrate. Schwann cells within the fibrin hydrogel developed complex process branching patterns, but, when presented with orientated nanofibres, showed a strong tendency to redistribute themselves onto the nanofibres, where they extended long processes that followed the longitudinal orientation of the nanofibres. The process length along nanofibre‐containing fibrin hydrogel reached near‐maximal levels (for the present experimental conditions) as early as 1 day after culturing. The ability of this three‐dimensional, extracellular matrix‐mimicking scaffold to support Schwann cell survival and provide topographical cues for rapid process extension suggest that it may be an appropriate device design for the bridging of experimental lesions of the peripheral nervous system.


  • Functional improvement following implantation of a microstructured, type-I collagen scaffold into experimental injuries of the adult rat spinal cord

    by Haktan Altinova, Sven Möllers, Tobias Führmann, Ronald Deumens, Ahmet Bozkurt, Ingo Heschel, Leon H.H. Olde Damink, Frank Schügner, Joachim Weis, Gary A. Brook