Iannis K. Kominis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Iannis K. Kominis has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
K. Mouloudakis
Department of Physics University of Crete 71003 Heraklion Greece
7 shared publicationsM. Loulakis
School of Applied Mathematical and Physical Sciences, National Technical University of Athens, 15780 Athens, Greece
5 shared publications- Michail Loulakis
School of Applied Mathematical and Physical Sciences National Technical University of Athens 15780 Athens Greece
4 shared publications A. Margaritakis
Department of Physics, University of Crete, Heraklion 71003, Greece
3 shared publicationsG. P. Tsironis
Department of Physics and Institute of Theoretical and Computational Physics University of Crete 70013 Heraklion Greece
3 shared publicationsK. M. Vitalis
Department of Physics, University of Crete, 70013 Heraklion, Greece
3 shared publications
Latest Publications
- Open Access
- 26 June 2026
- Published by IOP Publishing in New Journal of Physics
- Vol. 28 (7) , 074511
Searching for quantum effects in the brain: A Bell-type test for nonclassical latent representations in autoencoders
Whether neural information processing is entirely classical or involves quantum-mechanical elements remains an open question. Here we propose a model-agnostic, information-theoretic test of nonclassicality that bypasses microscopic assumptions and instead probes the structure of neural representations themselves. Using autoencoders as a transparent model system, we introduce a Bell-type consistency test in latent space, and ask whether decoding statistics obtained under multiple readout contexts can be jointly explained by a single positive latent-variable distribution. By shifting the search for quantum-like signatures in neural systems from microscopic dynamics to experimentally testable constraints on information processing, this work opens a new route for probing the fundamental physics of neural computation. The proposed test identifies violations of classical latent-variable consistency at the level of statistical representations, without assuming a specific underlying physical mechanism.
- 26 June 2026
- Published by IOP Publishing in New Journal of Physics
- Vol. 28 (7) , 074511
Open AccessSearching for quantum effects in the brain: A Bell-type test for nonclassical latent representations in autoencoders
Whether neural information processing is entirely classical or involves quantum-mechanical elements remains an open question. Here we propose a model-agnostic, information-theoretic test of nonclassicality that bypasses microscopic assumptions and instead probes the structure of neural representations themselves. Using autoencoders as a transparent model system, we introduce a Bell-type consistency test in latent space, and ask whether decoding statistics obtained under multiple readout contexts can be jointly explained by a single positive latent-variable distribution. By shifting the search for quantum-like signatures in neural systems from microscopic dynamics to experimentally testable constraints on information processing, this work opens a new route for probing the fundamental physics of neural computation. The proposed test identifies violations of classical latent-variable consistency at the level of statistical representations, without assuming a specific underlying physical mechanism.
- Open Access
- 9 June 2026
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 8 (2)
Metabolic quantum limit to the information capacity of magnetoencephalography
Magnetoencephalography (MEG) measures the magnetic fields generated by neural currents using quantum sensors such as superconducting quantum interference devices and atomic magnetometers. Here, we combine the energy resolution limit of magnetic sensing with the metabolic power available to neural currents to derive a technology-independent bound on the information capacity of MEG. The bound factorizes into geometry, metabolism, and Planck's constant, and gives an estimated maximum information rate of 2.2 Mbit/s for representative human-brain parameters. Further, we show that the externally measurable magnetic field has a finite angular bandwidth, with high multipole components being geometrically attenuated and falling below the quantum-limited noise floor. This yields an information-limited spatial scale of order 1 cm and renders the accessible measurement space effectively finite dimensional. The energy resolution limit therefore defines an information-theoretic Nyquist scale for magnetoencephalography, beyond which denser spatial sampling provides redundant measurements rather than additional recoverable information. Since the energy resolution limit also makes the noise variance grow linearly with measurement bandwidth, temporal and spatial bandwidths compete, producing a fundamental spatiotemporal trade-off. These results show how quantum-limited measurements constrain the observable complexity and information content of noninvasive brain imaging, providing a quantitative link between fundamental physics and neuroscience.
- 9 June 2026
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 8 (2)
Open AccessMetabolic quantum limit to the information capacity of magnetoencephalography
Magnetoencephalography (MEG) measures the magnetic fields generated by neural currents using quantum sensors such as superconducting quantum interference devices and atomic magnetometers. Here, we combine the energy resolution limit of magnetic sensing with the metabolic power available to neural currents to derive a technology-independent bound on the information capacity of MEG. The bound factorizes into geometry, metabolism, and Planck's constant, and gives an estimated maximum information rate of 2.2 Mbit/s for representative human-brain parameters. Further, we show that the externally measurable magnetic field has a finite angular bandwidth, with high multipole components being geometrically attenuated and falling below the quantum-limited noise floor. This yields an information-limited spatial scale of order 1 cm and renders the accessible measurement space effectively finite dimensional. The energy resolution limit therefore defines an information-theoretic Nyquist scale for magnetoencephalography, beyond which denser spatial sampling provides redundant measurements rather than additional recoverable information. Since the energy resolution limit also makes the noise variance grow linearly with measurement bandwidth, temporal and spatial bandwidths compete, producing a fundamental spatiotemporal trade-off. These results show how quantum-limited measurements constrain the observable complexity and information content of noninvasive brain imaging, providing a quantitative link between fundamental physics and neuroscience.
- 20 April 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (7)
Constraining axionlike dark matter with a radio-frequency atomic magnetometer
- 20 April 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (7)
Constraining axionlike dark matter with a radio-frequency atomic magnetometer
- 3 February 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (2)
Quantum sensitivity limits and dynamical correlations in alkali-vapor sensors
- 3 February 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (2)
Quantum sensitivity limits and dynamical correlations in alkali-vapor sensors
- Open Access
Searching for Quantum Effects in the Brain: A Bell-Type Test for Nonclassical Latent Representations in Autoencoders
Whether neural information processing is entirely classical or involves quantum-mechanical elements remains an open question. Here we propose a model-agnostic, information-theoretic test of nonclassicality that bypasses microscopic assumptions and instead probes the structure of neural representations themselves. Using autoencoders as a transparent model system, we introduce a Bell-type consistency test in latent space, and ask whether decoding statistics obtained under multiple readout contexts can be jointly explained by a single positive latent-variable distribution. By shifting the search for quantum-like signatures in neural systems from microscopic dynamics to experimentally testable constraints on information processing, this work opens a new route for probing the fundamental physics of neural computation.
Open AccessSearching for Quantum Effects in the Brain: A Bell-Type Test for Nonclassical Latent Representations in Autoencoders
Whether neural information processing is entirely classical or involves quantum-mechanical elements remains an open question. Here we propose a model-agnostic, information-theoretic test of nonclassicality that bypasses microscopic assumptions and instead probes the structure of neural representations themselves. Using autoencoders as a transparent model system, we introduce a Bell-type consistency test in latent space, and ask whether decoding statistics obtained under multiple readout contexts can be jointly explained by a single positive latent-variable distribution. By shifting the search for quantum-like signatures in neural systems from microscopic dynamics to experimentally testable constraints on information processing, this work opens a new route for probing the fundamental physics of neural computation.
- Open Access
- 10 November 2025
- Published by MDPI AG in Preprints.org
Metabolic Quantum Limit and Holographic Bound to the Information Capacity of Magnetoencephalography
Magnetoencephalography, the noninvasive measurement of magnetic fields produced by brain activity, utilizes quantum sensors like superconducting quantum interference devices or atomic magnetometers. Here we derive a fundamental, technology-independent bound on the information that such measurements can convey. Using the energy resolution limit of magnetic sensing together with the brain's metabolic power, we obtain a universal expression for the maximum information rate, which depends only on geometry, metabolism, and Planck's constant, and the numerical value of which is 2.6 Mbit/s. At the high bandwidth limit we arrive at a bound scaling linearly with the area of the current source boundary. We thus demonstrate a biophysical holographic bound for metabolically powered information conveyed by the magnetic field. For the geometry and metabolic power of the human brain the geometric bound is 6.6 Gbit/s.
- 10 November 2025
- Published by MDPI AG in Preprints.org
Open AccessMetabolic Quantum Limit and Holographic Bound to the Information Capacity of Magnetoencephalography
Magnetoencephalography, the noninvasive measurement of magnetic fields produced by brain activity, utilizes quantum sensors like superconducting quantum interference devices or atomic magnetometers. Here we derive a fundamental, technology-independent bound on the information that such measurements can convey. Using the energy resolution limit of magnetic sensing together with the brain's metabolic power, we obtain a universal expression for the maximum information rate, which depends only on geometry, metabolism, and Planck's constant, and the numerical value of which is 2.6 Mbit/s. At the high bandwidth limit we arrive at a bound scaling linearly with the area of the current source boundary. We thus demonstrate a biophysical holographic bound for metabolically powered information conveyed by the magnetic field. For the geometry and metabolic power of the human brain the geometric bound is 6.6 Gbit/s.
- Open Access
- 4 November 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (17)
Prospecting for lunar 3He with a radio-frequency atomic magnetometer
Mining 3He from lunar regolith has attracted significant interest in recent years due to the scarcity of 3He on Earth and its diverse applications, from cryogenics and medical imaging, to nuclear physics and future nuclear fusion. Given the stringent technical and economic challenges of mining lunar 3He, precise prospecting is essential. Here, we propose a prospecting methodology based on a radio-frequency atomic magnetometer, which can detect the dipolar magnetic field of thermally polarized 3He spins. With a 200 g regolith sample and an rf magnetometer with sensitivity 1fT/Hz, we can detect 3He with abundance 5 ppb within a measurement time of just 5 min. The associated apparatus is lightweight and significantly more cost-effective than alternative measurement techniques. The proposed prospecting method is readily deployable and could substantially improve the technical and economic feasibility of mining lunar 3He.
- 4 November 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (17)
Open AccessProspecting for lunar 3He with a radio-frequency atomic magnetometer
Mining 3He from lunar regolith has attracted significant interest in recent years due to the scarcity of 3He on Earth and its diverse applications, from cryogenics and medical imaging, to nuclear physics and future nuclear fusion. Given the stringent technical and economic challenges of mining lunar 3He, precise prospecting is essential. Here, we propose a prospecting methodology based on a radio-frequency atomic magnetometer, which can detect the dipolar magnetic field of thermally polarized 3He spins. With a 200 g regolith sample and an rf magnetometer with sensitivity 1fT/Hz, we can detect 3He with abundance 5 ppb within a measurement time of just 5 min. The associated apparatus is lightweight and significantly more cost-effective than alternative measurement techniques. The proposed prospecting method is readily deployable and could substantially improve the technical and economic feasibility of mining lunar 3He.
- Open Access
Prospecting for lunar Helium-3 with a radio-frequency atomic magnetometer
Mining $^3{\rm He}$ from lunar regolith has attracted significant interest in recent years due to the scarcity of $^3{\rm He}$ on Earth and its diverse applications, from cryogenics and medical imaging, to nuclear physics and future nuclear fusion. Given the stringent technical and economic challenges of mining lunar $^3{\rm He}$, precise prospecting is essential. Here we propose a prospecting methodology based on a radio-frequency atomic magnetometer, which can detect the dipolar magnetic field of thermally polarized $^3{\rm He}$ spins. With a 200 g regolith sample and an rf-magnetometer with sensitivity $1~{\rm fT/\sqrt{Hz}}$ we can detect $^3{\rm He}$ with abundance 5 ppb within a measurement time of just 5 min. The associated apparatus is lightweight and significantly more cost-effective than alternative measurement techniques. The proposed prospecting method is readily deployable and could substantially improve the technical and economic feasibility of mining lunar $^3{\rm He}$.Open AccessProspecting for lunar Helium-3 with a radio-frequency atomic magnetometer
Mining $^3{\rm He}$ from lunar regolith has attracted significant interest in recent years due to the scarcity of $^3{\rm He}$ on Earth and its diverse applications, from cryogenics and medical imaging, to nuclear physics and future nuclear fusion. Given the stringent technical and economic challenges of mining lunar $^3{\rm He}$, precise prospecting is essential. Here we propose a prospecting methodology based on a radio-frequency atomic magnetometer, which can detect the dipolar magnetic field of thermally polarized $^3{\rm He}$ spins. With a 200 g regolith sample and an rf-magnetometer with sensitivity $1~{\rm fT/\sqrt{Hz}}$ we can detect $^3{\rm He}$ with abundance 5 ppb within a measurement time of just 5 min. The associated apparatus is lightweight and significantly more cost-effective than alternative measurement techniques. The proposed prospecting method is readily deployable and could substantially improve the technical and economic feasibility of mining lunar $^3{\rm He}$. - Open Access
- 17 June 2025
- Published by MDPI AG in Preprints.org
Prospecting for Lunar 3He with a Radio-Frequency Atomic Magnetometer
Mining $^3{\rm He}$ from lunar regolith has attracted significant interest in recent years due to the scarcity of $^3{\rm He}$ on Earth and its diverse applications, from cryogenics and medical imaging, to nuclear physics and future nuclear fusion. Given the stringent technical and economic challenges of mining lunar $^3{\rm He}$, precise prospecting is essential. Here we propose a prospecting methodology based on a radio-frequency atomic magnetometer, which can detect the dipolar magnetic field of thermally polarized $^3{\rm He}$ spins. With a 200 g regolith sample and an rf-magnetometer with sensitivity $1~{\rm fT/\sqrt{Hz}}$ we can detect $^3{\rm He}$ with abundance 5 ppb within a measurement time of just 5 min. The associated apparatus is lightweight and significantly more cost-effective than alternative measurement techniques. The proposed prospecting method is readily deployable and could substantially improve the technical and economic feasibility of mining lunar $^3{\rm He}$.- 17 June 2025
- Published by MDPI AG in Preprints.org
Open AccessProspecting for Lunar 3He with a Radio-Frequency Atomic Magnetometer
Mining $^3{\rm He}$ from lunar regolith has attracted significant interest in recent years due to the scarcity of $^3{\rm He}$ on Earth and its diverse applications, from cryogenics and medical imaging, to nuclear physics and future nuclear fusion. Given the stringent technical and economic challenges of mining lunar $^3{\rm He}$, precise prospecting is essential. Here we propose a prospecting methodology based on a radio-frequency atomic magnetometer, which can detect the dipolar magnetic field of thermally polarized $^3{\rm He}$ spins. With a 200 g regolith sample and an rf-magnetometer with sensitivity $1~{\rm fT/\sqrt{Hz}}$ we can detect $^3{\rm He}$ with abundance 5 ppb within a measurement time of just 5 min. The associated apparatus is lightweight and significantly more cost-effective than alternative measurement techniques. The proposed prospecting method is readily deployable and could substantially improve the technical and economic feasibility of mining lunar $^3{\rm He}$. - Open Access
- 16 January 2025
- Published by American Physical Society (APS) in PRX Life
- Vol. 3 (1)
Approaching the Quantum Limit of Energy Resolution in Animal Magnetoreception
A large number of magnetic sensors, like superconducting quantum interference devices, optical pumping, and nitrogen vacancy magnetometers, were shown to satisfy the energy resolution limit. This limit states that the magnetic sensitivity of the sensor, when translated into a product of energy with time, is bounded below by Planck's constant, ℏ . This bound implies a fundamental limitation as to what can be achieved in magnetic sensing. Here we explore biological magnetometers, in particular three magnetoreception mechanisms thought to underly animals' geomagnetic field sensing: the radical-pair, the magnetite, and the MagR mechanism. We address the question of how close these mechanisms approach the energy resolution limit. At the quantitative level, the utility of the energy resolution limit is that it informs the workings of magnetic sensing in model-independent ways and thus can provide subtle consistency checks for theoretical models and estimated or measured parameter values, particularly needed in complex biological systems. At the qualitative level, the closer the energy resolution is to ℏ , the more “quantum” is the sensor. This offers an alternative route towards understanding the quantum biology of magnetoreception. It also quantifies the room for improvement, illuminating what nature has achieved, and stimulating the engineering of biomimetic sensors exceeding nature's magnetic sensing performance.
- 16 January 2025
- Published by American Physical Society (APS) in PRX Life
- Vol. 3 (1)
Open AccessApproaching the Quantum Limit of Energy Resolution in Animal Magnetoreception
A large number of magnetic sensors, like superconducting quantum interference devices, optical pumping, and nitrogen vacancy magnetometers, were shown to satisfy the energy resolution limit. This limit states that the magnetic sensitivity of the sensor, when translated into a product of energy with time, is bounded below by Planck's constant, ℏ . This bound implies a fundamental limitation as to what can be achieved in magnetic sensing. Here we explore biological magnetometers, in particular three magnetoreception mechanisms thought to underly animals' geomagnetic field sensing: the radical-pair, the magnetite, and the MagR mechanism. We address the question of how close these mechanisms approach the energy resolution limit. At the quantitative level, the utility of the energy resolution limit is that it informs the workings of magnetic sensing in model-independent ways and thus can provide subtle consistency checks for theoretical models and estimated or measured parameter values, particularly needed in complex biological systems. At the qualitative level, the closer the energy resolution is to ℏ , the more “quantum” is the sensor. This offers an alternative route towards understanding the quantum biology of magnetoreception. It also quantifies the room for improvement, illuminating what nature has achieved, and stimulating the engineering of biomimetic sensors exceeding nature's magnetic sensing performance.