George Trellopoulos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
George Trellopoulos has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Efstratios Georgakarakos
Department of Vascular Surgery, “Democritus” University of Thrace, University Hospital of Alexandroupolis, Alexandroupolis, Greece
5 shared publications - George S. Georgiadis
Vascular Surgery Department, Medical School, Democritus University of Thrace, Alexandroupolis, Greece
4 shared publications - Argiro Pipinia
Plastic and Hand Surgery Department & Burn Unit, “G. Papanikolaou” Hospital, 57010 Thessaloniki, Greece
2 shared publications Athanasia Papachristodoulou
Laboratory of Radiology, Euromedic, Thessaloniki, Greece
2 shared publications- Christos V. Ioannou
Vascular Surgery Department, Medical School, University of Crete, Heraklion, Greece
2 shared publications Dimitrios Pelekas
First Surgical Clinic, General Hospital "G. Papanikolaou", Thessaloniki, Greece
2 shared publications
Latest Publications
- Open Access
- 9 February 2026
- Published by MDPI AG in European Burn Journal
- Vol. 7 (1) , 10
Intravascular Rewarming in Major Burns: A Rare but Serious Catheter-Related Complication
Introduction: Patients with major burn injuries are highly susceptible to hypothermia due to extensive skin loss, aggressive fluid resuscitation, repeated surgical procedures, and exposure during wound care. Hypothermia is associated with coagulation disorders, increased blood loss, impaired immune response, prolonged hospitalization, and increased mortality. When conventional warming strategies fail, intravascular temperature management systems may be employed, although they carry risks inherent to central venous catheters. Case Report: We report the case of a 26-year-old male with 66% total body surface area flame burns and inhalational injury, admitted to the Burns Intensive Care Unit with persistent hypothermia despite standard warming measures. An intravascular temperature management catheter was inserted via the femoral vein and successfully restored normothermia. Due to clinical instability, the catheter remained in situ beyond the recommended duration. During attempted catheter removal, significant resistance was encountered, raising concern for mechanical malfunction. Imaging confirmed catheter entrapment without fracture. Multidisciplinary management involving vascular surgery and interventional radiology enabled successful removal using endovascular snare techniques. A detached balloon fragment was identified and secured with venous stenting. Conclusions: This report describes the first documented case of complicated removal of an intravascular warming catheter due to balloon detachment in burn patients. Physicians using these devices should be aware of this possible complication and be prepared for its management.
- 9 February 2026
- Published by MDPI AG in European Burn Journal
- Vol. 7 (1) , 10
Open AccessIntravascular Rewarming in Major Burns: A Rare but Serious Catheter-Related Complication
Introduction: Patients with major burn injuries are highly susceptible to hypothermia due to extensive skin loss, aggressive fluid resuscitation, repeated surgical procedures, and exposure during wound care. Hypothermia is associated with coagulation disorders, increased blood loss, impaired immune response, prolonged hospitalization, and increased mortality. When conventional warming strategies fail, intravascular temperature management systems may be employed, although they carry risks inherent to central venous catheters. Case Report: We report the case of a 26-year-old male with 66% total body surface area flame burns and inhalational injury, admitted to the Burns Intensive Care Unit with persistent hypothermia despite standard warming measures. An intravascular temperature management catheter was inserted via the femoral vein and successfully restored normothermia. Due to clinical instability, the catheter remained in situ beyond the recommended duration. During attempted catheter removal, significant resistance was encountered, raising concern for mechanical malfunction. Imaging confirmed catheter entrapment without fracture. Multidisciplinary management involving vascular surgery and interventional radiology enabled successful removal using endovascular snare techniques. A detached balloon fragment was identified and secured with venous stenting. Conclusions: This report describes the first documented case of complicated removal of an intravascular warming catheter due to balloon detachment in burn patients. Physicians using these devices should be aware of this possible complication and be prepared for its management.
- Open Access
- 19 January 2026
- Published by MDPI AG in Preprints.org
Intravascular Rewarming in Major Burns: A Rare but Serious Catheter – Related Complication
Introduction: Patients with major burn injuries are highly susceptible to hypothermia due to extensive skin loss, aggressive fluid resuscitation, repeated surgical procedures, and exposure during wound care. Hypothermia is associated with coagulation disorders, increased blood loss, impaired immune response, prolonged hospitalization, and increased mortality. When conventional warming strategies fail, intravascular temperature management systems may be employed, although they carry risks inherent to central venous catheters. Case Report: We report the case of a 26-year-old male with 66% total body surface area flame burns and inhalational injury, admitted to the Burns Intensive Care Unit with persistent hypothermia despite standard warming measures. An intravascular temperature management catheter was inserted via the femoral vein and successfully restored normothermia. Due to clinical instability, the catheter remained in situ beyond the recommended duration. During attempted catheter removal, significant resistance was encountered, raising concern for mechanical malfunction. Imaging confirmed catheter entrapment without fracture. Multidisciplinary management involving vascular surgery and interventional radiology enabled successful removal using endovascular snare techniques. A detached balloon fragment was identified and secured with venous stenting. Conclusions: This report describes the first documented case of complicated removal of an intravascular warming catheter due to balloon detachment in burn patients. Physicians using these devices should be aware of this possible complication and be prepared for its management.
- 19 January 2026
- Published by MDPI AG in Preprints.org
Open AccessIntravascular Rewarming in Major Burns: A Rare but Serious Catheter – Related Complication
Introduction: Patients with major burn injuries are highly susceptible to hypothermia due to extensive skin loss, aggressive fluid resuscitation, repeated surgical procedures, and exposure during wound care. Hypothermia is associated with coagulation disorders, increased blood loss, impaired immune response, prolonged hospitalization, and increased mortality. When conventional warming strategies fail, intravascular temperature management systems may be employed, although they carry risks inherent to central venous catheters. Case Report: We report the case of a 26-year-old male with 66% total body surface area flame burns and inhalational injury, admitted to the Burns Intensive Care Unit with persistent hypothermia despite standard warming measures. An intravascular temperature management catheter was inserted via the femoral vein and successfully restored normothermia. Due to clinical instability, the catheter remained in situ beyond the recommended duration. During attempted catheter removal, significant resistance was encountered, raising concern for mechanical malfunction. Imaging confirmed catheter entrapment without fracture. Multidisciplinary management involving vascular surgery and interventional radiology enabled successful removal using endovascular snare techniques. A detached balloon fragment was identified and secured with venous stenting. Conclusions: This report describes the first documented case of complicated removal of an intravascular warming catheter due to balloon detachment in burn patients. Physicians using these devices should be aware of this possible complication and be prepared for its management.
- 1 June 2016
- Vol. 57 (3) , 479-81
The inflatable-rings fixation mechanism of the Trivascular Ovation® Stent Graft System: every revolution comes at a price!
- 1 June 2016
- Vol. 57 (3) , 479-81
The inflatable-rings fixation mechanism of the Trivascular Ovation® Stent Graft System: every revolution comes at a price!
- 16 February 2016
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 13 (3) , 1-10
The ovation abdominal stent graft for the treatment of abdominal aortic aneurysms: current evidence and future perspectives
The Ovation Abdominal Stent Graft System is a trimodular endoprosthesis recently introduced for the endovascular repair of abdominal aortic aneurysm (AAA). It uncouples the stages of stent-graft fixation and sealing with the suprarenal fixation achieved with a long, rigid anchored stent while the sealing onto the neck is accomplished via a pair of polymer-filled inflatable rings that accommodate to each patient's individual anatomy. Moreover, the lack of Nitinol support enables lower profiles of the endograft's delivery system, thus facilitating the navigation through angulated and stenosed iliac vessels. Ovation's novel design expands further the AAA eligibility to endovascular repair. This article discusses the clinical and hemodynamic consequences of the Ovation design and contributes to better understanding of current and future implications.
- 16 February 2016
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 13 (3) , 1-10
The ovation abdominal stent graft for the treatment of abdominal aortic aneurysms: current evidence and future perspectives
The Ovation Abdominal Stent Graft System is a trimodular endoprosthesis recently introduced for the endovascular repair of abdominal aortic aneurysm (AAA). It uncouples the stages of stent-graft fixation and sealing with the suprarenal fixation achieved with a long, rigid anchored stent while the sealing onto the neck is accomplished via a pair of polymer-filled inflatable rings that accommodate to each patient's individual anatomy. Moreover, the lack of Nitinol support enables lower profiles of the endograft's delivery system, thus facilitating the navigation through angulated and stenosed iliac vessels. Ovation's novel design expands further the AAA eligibility to endovascular repair. This article discusses the clinical and hemodynamic consequences of the Ovation design and contributes to better understanding of current and future implications.
- 1 July 2015
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 29 (5) , 913-919
Initial Single-Center Experience with the Ovation Stent-Graft System in the Treatment of Abdominal Aortic Aneurysms: Application to Challenging Iliac Access Anatomies
- 1 July 2015
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 29 (5) , 913-919
Initial Single-Center Experience with the Ovation Stent-Graft System in the Treatment of Abdominal Aortic Aneurysms: Application to Challenging Iliac Access Anatomies
- 1 July 2014
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 28 (5) , 1324-1328
Chimney and Periscope Technique for Emergent Treatment of Spontaneous Aortic Rupture
- 1 July 2014
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 28 (5) , 1324-1328
Chimney and Periscope Technique for Emergent Treatment of Spontaneous Aortic Rupture
- 30 May 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 37 (5) , 1393-1394
The Chimney Technique with the Ovation Abdominal Stent Graft System: An Ideal Platform for Self-expandable Renal Stents?
- 30 May 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 37 (5) , 1393-1394
The Chimney Technique with the Ovation Abdominal Stent Graft System: An Ideal Platform for Self-expandable Renal Stents?
- 30 November 2008
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 48 (5) , 1356
Transposed brachial-basilic arteriovenous fistulas versus prosthetic upper limb grafts: A meta-analysis
- 30 November 2008
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 48 (5) , 1356
Transposed brachial-basilic arteriovenous fistulas versus prosthetic upper limb grafts: A meta-analysis
- Open Access
- 1 January 2008
- Published by Springer Nature in Thrombosis Journal
- Vol. 6 (1) , 9
Successful management of acute thromboembolic disease complicated with heparin induced thrombocytopenia type II (HIT II): a case series
Heparin-induced thrombocytopenia type II (HIT II) is a rare immune-mediated complication of heparin. The diagnosis of HIT is considered in patients exposed to heparin, presenting with thrombocytopenia and thrombosis.
- 1 January 2008
- Published by Springer Nature in Thrombosis Journal
- Vol. 6 (1) , 9
Open AccessSuccessful management of acute thromboembolic disease complicated with heparin induced thrombocytopenia type II (HIT II): a case series
Heparin-induced thrombocytopenia type II (HIT II) is a rare immune-mediated complication of heparin. The diagnosis of HIT is considered in patients exposed to heparin, presenting with thrombocytopenia and thrombosis.