Adnan Qamar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Adnan Qamar has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Joseph L. Bull
Department of Biomedical Engineering, Tulane University, New Orleans, USA
3 shared publications - Noreddine Ghaffour
Environmental Science and Engineering Program, Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia
2 shared publications - Sarah Kerdi
Water Desalination and Reuse Center (WDRC), King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia
2 shared publications - Ahad Syed
Core Laboratories, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia
1 shared publication Doug T. Valassis
C Case Medical Center , Case Western Reserve University , Cleveland , OH , USA
1 shared publication- Henry J. Tanudjaja
Environmental Science and Engineering Program, Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
Spacer Designs for Improved Hydrodynamics and Filtration Efficiency in Sea Water Reverse Osmosis
Reverse osmosis (RO) filtration performance is heavily influenced by the design of the feed spacer. Spacer design impacts hydrodynamic patterns within the system, affecting water production and concentration polarization. Two spacer designs, namely pillar (P) and standard (S), were investigated to improve the performance of a commercially available spacer design (C) in the RO process. Two approaches were employed to evaluate spacer performance. First, direct numerical simulation (DNS) was utilized to fundamentally understand the hydrodynamics generated by each spacer design. Second, laboratory RO experiments were conducted to confirm the simulation results. The P and S spacers induced higher flow velocity and vorticity than the C spacer, as confirmed by simulations and experiments. Reduced dead zones were also demonstrated using P and S spacers. However, the standard spacer design exhibited a clear advantage in promoting more efficient mixing within the filtration channels. This enhanced mixing substantially reduced salt concentration at the membrane surface, improving the filtration performance. In agreement with the permeation velocity computation, the S spacer achieved the highest improvement (13%) in both flux yield and specific flux relative to the C spacer. This finding confirms the S spacer’s ability to enhance RO performance while reducing energy consumption.
Open AccessSpacer Designs for Improved Hydrodynamics and Filtration Efficiency in Sea Water Reverse Osmosis
Reverse osmosis (RO) filtration performance is heavily influenced by the design of the feed spacer. Spacer design impacts hydrodynamic patterns within the system, affecting water production and concentration polarization. Two spacer designs, namely pillar (P) and standard (S), were investigated to improve the performance of a commercially available spacer design (C) in the RO process. Two approaches were employed to evaluate spacer performance. First, direct numerical simulation (DNS) was utilized to fundamentally understand the hydrodynamics generated by each spacer design. Second, laboratory RO experiments were conducted to confirm the simulation results. The P and S spacers induced higher flow velocity and vorticity than the C spacer, as confirmed by simulations and experiments. Reduced dead zones were also demonstrated using P and S spacers. However, the standard spacer design exhibited a clear advantage in promoting more efficient mixing within the filtration channels. This enhanced mixing substantially reduced salt concentration at the membrane surface, improving the filtration performance. In agreement with the permeation velocity computation, the S spacer achieved the highest improvement (13%) in both flux yield and specific flux relative to the C spacer. This finding confirms the S spacer’s ability to enhance RO performance while reducing energy consumption.
- Open Access
- 28 June 2021
- Published by MDPI AG in Bioengineering
- Vol. 8 (7) , 89
Bioengineering Progress in Lung Assist Devices
Artificial lung technology is advancing at a startling rate raising hopes that it would better serve the needs of those requiring respiratory support. Whether to assist the healing of an injured lung, support patients to lung transplantation, or to entirely replace native lung function, safe and effective artificial lungs are sought. After 200 years of bioengineering progress, artificial lungs are closer than ever before to meet this demand which has risen exponentially due to the COVID-19 crisis. In this review, the critical advances in the historical development of artificial lungs are detailed. The current state of affairs regarding extracorporeal membrane oxygenation, intravascular lung assists, pump-less extracorporeal lung assists, total artificial lungs, and microfluidic oxygenators are outlined.
- 28 June 2021
- Published by MDPI AG in Bioengineering
- Vol. 8 (7) , 89
Open AccessBioengineering Progress in Lung Assist Devices
Artificial lung technology is advancing at a startling rate raising hopes that it would better serve the needs of those requiring respiratory support. Whether to assist the healing of an injured lung, support patients to lung transplantation, or to entirely replace native lung function, safe and effective artificial lungs are sought. After 200 years of bioengineering progress, artificial lungs are closer than ever before to meet this demand which has risen exponentially due to the COVID-19 crisis. In this review, the critical advances in the historical development of artificial lungs are detailed. The current state of affairs regarding extracorporeal membrane oxygenation, intravascular lung assists, pump-less extracorporeal lung assists, total artificial lungs, and microfluidic oxygenators are outlined.
- Open Access
Hole-Type Spacers for More Stable Shale Gas-Produced Water Treatment by Forward Osmosis
An appropriate spacer design helps in minimizing membrane fouling which remains the major obstacle in forward osmosis (FO) systems. In the present study, the performance of a hole-type spacer (having holes at the filament intersections) was evaluated in a FO system and compared to a standard spacer design (without holes). The hole-type spacer exhibited slightly higher water flux and reverse solute flux (RSF) when Milli-Q water was used as feed solution and varied sodium chloride concentrations as draw solution. During shale gas produced water treatment, a severe flux decline was observed for both spacer designs due to the formation of barium sulfate scaling. SEM imaging revealed that the high shear force induced by the creation of holes led to the formation of scales on the entire membrane surface, causing a slightly higher flux decline than the standard spacer. Simultaneously, the presence of holes aided to mitigate the accumulation of foulants on spacer surface, resulting in no increase in pressure drop. Furthermore, a full cleaning efficiency was achieved by hole-type spacer attributed to the micro-jets effect induced by the holes, which aided to destroy the foulants and then sweep them away from the membrane surface.
Open AccessHole-Type Spacers for More Stable Shale Gas-Produced Water Treatment by Forward Osmosis
An appropriate spacer design helps in minimizing membrane fouling which remains the major obstacle in forward osmosis (FO) systems. In the present study, the performance of a hole-type spacer (having holes at the filament intersections) was evaluated in a FO system and compared to a standard spacer design (without holes). The hole-type spacer exhibited slightly higher water flux and reverse solute flux (RSF) when Milli-Q water was used as feed solution and varied sodium chloride concentrations as draw solution. During shale gas produced water treatment, a severe flux decline was observed for both spacer designs due to the formation of barium sulfate scaling. SEM imaging revealed that the high shear force induced by the creation of holes led to the formation of scales on the entire membrane surface, causing a slightly higher flux decline than the standard spacer. Simultaneously, the presence of holes aided to mitigate the accumulation of foulants on spacer surface, resulting in no increase in pressure drop. Furthermore, a full cleaning efficiency was achieved by hole-type spacer attributed to the micro-jets effect induced by the holes, which aided to destroy the foulants and then sweep them away from the membrane surface.
- 28 June 2017
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 20 (11) , 1182-1194
Small-bubble transport and splitting dynamics in a symmetric bifurcation
Simulations of small bubbles traveling through symmetric bifurcations are conducted to garner information pertinent to gas embolotherapy, a potential cancer treatment. Gas embolotherapy procedures use intra-arterial bubbles to occlude tumor blood supply. As bubbles pass through bifurcations in the blood stream nonhomogeneous splitting and undesirable bioeffects may occur. To aid development of gas embolotherapy techniques, a volume of fluid method is used to model the splitting process of gas bubbles passing through artery and arteriole bifurcations. The model reproduces the variety of splitting behaviors observed experimentally, including the bubble reversal phenomenon. Splitting homogeneity and maximum shear stress along the vessel walls is predicted over a variety of physical parameters. Small bubbles, having initial length less than twice the vessel diameter, were found unlikely to split in the presence of gravitational asymmetry. Maximum shear stresses were found to decrease exponentially with increasing Reynolds number. Vortex-induced shearing near the bifurcation is identified as a possible mechanism for endothelial cell damage.
- 28 June 2017
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 20 (11) , 1182-1194
Small-bubble transport and splitting dynamics in a symmetric bifurcation
Simulations of small bubbles traveling through symmetric bifurcations are conducted to garner information pertinent to gas embolotherapy, a potential cancer treatment. Gas embolotherapy procedures use intra-arterial bubbles to occlude tumor blood supply. As bubbles pass through bifurcations in the blood stream nonhomogeneous splitting and undesirable bioeffects may occur. To aid development of gas embolotherapy techniques, a volume of fluid method is used to model the splitting process of gas bubbles passing through artery and arteriole bifurcations. The model reproduces the variety of splitting behaviors observed experimentally, including the bubble reversal phenomenon. Splitting homogeneity and maximum shear stress along the vessel walls is predicted over a variety of physical parameters. Small bubbles, having initial length less than twice the vessel diameter, were found unlikely to split in the presence of gravitational asymmetry. Maximum shear stresses were found to decrease exponentially with increasing Reynolds number. Vortex-induced shearing near the bifurcation is identified as a possible mechanism for endothelial cell damage.
- 28 June 2017
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 20 (11) , 1195-1211
Transport and flow characteristics of an oscillating cylindrical fiber for total artificial lung application
Mass transport and fluid dynamics characteristics in the vicinity of an oscillating cylindrical fiber with an imposed pulsatile inflow condition are computationally investigated in the present study. The work is motivated by a recently proposed design modification to the Total Artificial Lung (TAL) device, which is expected to provide better gas exchange. Navier–Stokes computations, coupled with convection–diffusion equation are performed to assess flow dynamics and mass transport behavior around the oscillating fiber. The oscillations and the pulsatile free stream velocity are represented by two sinusoidal functions. The resulting non-dimensional parameters are Keulegan–Carpenter number (KC), Schmidt number (Sc), Reynolds number (Re), pulsatile inflow amplitude ( ), and amplitude of cylinder oscillation ( ). Results are computed for , Sc = 1000, Re = 5 and 10, and 0.7 and 0.25 5.25. The pulsatile inflow parameters correspond to the flow velocities found in human pulmonary artery while matching the operating TAL Reynolds number. Mass transport from the surface of the cylinder to the bulk fluid is found to be primarily dependent on the size of surface vortices created by the movement of the cylinder. Time-averaged surface Sherwood number (Sh) is dependent on the amplitude and KC of cylinder oscillation. Compared to the fixed cylinder case, a significant gain up to 380% in Sh is achieved by oscillating the cylinder even at the small displacement amplitude (AD = 0.75D). Moreover, with decrease in KC the oscillating cylinder exhibits a lower drag amplitude compared with the fixed cylinder case. Inflow pulsation amplitude has minor effects on the mass transport characteristics. However, an increase in results in an increase in the amplitude of the periodic drag force on the cylinder. This rise in the drag amplitude is similar to that measured for the fixed cylinder case. Quantifications of shear stress distribution in the bulk fluid suggest that the physiological concerns of platelet activation and injury to red blood cells due to cylinder oscillation are negligible.
- 28 June 2017
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 20 (11) , 1195-1211
Transport and flow characteristics of an oscillating cylindrical fiber for total artificial lung application
Mass transport and fluid dynamics characteristics in the vicinity of an oscillating cylindrical fiber with an imposed pulsatile inflow condition are computationally investigated in the present study. The work is motivated by a recently proposed design modification to the Total Artificial Lung (TAL) device, which is expected to provide better gas exchange. Navier–Stokes computations, coupled with convection–diffusion equation are performed to assess flow dynamics and mass transport behavior around the oscillating fiber. The oscillations and the pulsatile free stream velocity are represented by two sinusoidal functions. The resulting non-dimensional parameters are Keulegan–Carpenter number (KC), Schmidt number (Sc), Reynolds number (Re), pulsatile inflow amplitude ( ), and amplitude of cylinder oscillation ( ). Results are computed for , Sc = 1000, Re = 5 and 10, and 0.7 and 0.25 5.25. The pulsatile inflow parameters correspond to the flow velocities found in human pulmonary artery while matching the operating TAL Reynolds number. Mass transport from the surface of the cylinder to the bulk fluid is found to be primarily dependent on the size of surface vortices created by the movement of the cylinder. Time-averaged surface Sherwood number (Sh) is dependent on the amplitude and KC of cylinder oscillation. Compared to the fixed cylinder case, a significant gain up to 380% in Sh is achieved by oscillating the cylinder even at the small displacement amplitude (AD = 0.75D). Moreover, with decrease in KC the oscillating cylinder exhibits a lower drag amplitude compared with the fixed cylinder case. Inflow pulsation amplitude has minor effects on the mass transport characteristics. However, an increase in results in an increase in the amplitude of the periodic drag force on the cylinder. This rise in the drag amplitude is similar to that measured for the fixed cylinder case. Quantifications of shear stress distribution in the bulk fluid suggest that the physiological concerns of platelet activation and injury to red blood cells due to cylinder oscillation are negligible.
- 10 September 2014
- Published by ASME International in Journal of Fluids Engineering
- Vol. 137 (2) , 021301
A Model for an Acoustically Driven Microbubble Inside a Rigid Tube
A theoretical framework to model the dynamics of acoustically driven microbubble inside a rigid tube is presented. The proposed model is not a variant of the conventional Rayleigh–Plesset category of models. It is derived from the reduced Navier–Stokes equation and is coupled with the evolving flow field solution inside the tube by a similarity transformation approach. The results are computed, and compared with experiments available in literature, for the initial bubble radius of Ro = 1.5 μm and 2 μm for the tube diameter of D = 12 μm and 200 μm with the acoustic parameters as utilized in the experiments. Results compare quite well with the existing experimental data. When compared to our earlier basic model, better agreement on a larger tube diameter is obtained with the proposed coupled model. The model also predicts, accurately, bubble fragmentation in terms of acoustic and geometric parameters.
- 10 September 2014
- Published by ASME International in Journal of Fluids Engineering
- Vol. 137 (2) , 021301
A Model for an Acoustically Driven Microbubble Inside a Rigid Tube
A theoretical framework to model the dynamics of acoustically driven microbubble inside a rigid tube is presented. The proposed model is not a variant of the conventional Rayleigh–Plesset category of models. It is derived from the reduced Navier–Stokes equation and is coupled with the evolving flow field solution inside the tube by a similarity transformation approach. The results are computed, and compared with experiments available in literature, for the initial bubble radius of Ro = 1.5 μm and 2 μm for the tube diameter of D = 12 μm and 200 μm with the acoustic parameters as utilized in the experiments. Results compare quite well with the existing experimental data. When compared to our earlier basic model, better agreement on a larger tube diameter is obtained with the proposed coupled model. The model also predicts, accurately, bubble fragmentation in terms of acoustic and geometric parameters.
- 7 January 2013
- Published by AIP Publishing in Applied Physics Letters
- Vol. 102 (1) , 013702
Dynamics of micro-bubble sonication inside a phantom vessel
A model for sonicated micro-bubble oscillations inside a phantom vessel is proposed. The model is not a variant of conventional Rayleigh-Plesset equation and is obtained from reduced Navier-Stokes equations. The model relates the micro-bubble oscillation dynamics with geometric and acoustic parameters in a consistent manner. It predicts micro-bubble oscillation dynamics as well as micro-bubble fragmentation when compared to the experimental data. For large micro-bubble radius to vessel diameter ratios, predictions are damped, suggesting breakdown of inherent modeling assumptions for these cases. Micro-bubble response with acoustic parameters is consistent with experiments and provides physical insight to the micro-bubble oscillation dynamics.
- 7 January 2013
- Published by AIP Publishing in Applied Physics Letters
- Vol. 102 (1) , 013702
Dynamics of micro-bubble sonication inside a phantom vessel
A model for sonicated micro-bubble oscillations inside a phantom vessel is proposed. The model is not a variant of conventional Rayleigh-Plesset equation and is obtained from reduced Navier-Stokes equations. The model relates the micro-bubble oscillation dynamics with geometric and acoustic parameters in a consistent manner. It predicts micro-bubble oscillation dynamics as well as micro-bubble fragmentation when compared to the experimental data. For large micro-bubble radius to vessel diameter ratios, predictions are damped, suggesting breakdown of inherent modeling assumptions for these cases. Micro-bubble response with acoustic parameters is consistent with experiments and provides physical insight to the micro-bubble oscillation dynamics.
- Open Access
- 1 January 2012
- Published by Taylor & Francis in Engineering Applications of Computational Fluid Mechanics
- Vol. 6 (3) , 316-335
Aerodynamics Characteristic of Axisymmetric Surface Protuberance in Supersonic Regime
The present work deals with the problem of an axi-symmetric surface protuberance mounted on a spherical nosed body of revolution. The numerical computations are carried out for laminar supersonic viscous flow for trapezoidal shape axi-symmetric protuberances. A free stream Mach number ranging from 3 to 8 in steps of 1 at a fixed free stream Reynolds number of 1.8×104 has been used in the present study. The steady solutions are obtained using a time marching approach. A newly developed Particle Velocity Upwinding (PVU) scheme has been used for the computation. The spatial flow pattern exhibits a strong bow shock in front of the hemispherical nose, which engulfs the entire base body. Near the protuberance, the fluid particle decelerates due to the adverse pressure created by the protuberance and thus the flow separates in front of the protuberance. This point of separation is found to be a function of Mach number and the protuberance shape. A low-pressure expansion region dominates the base region of the obstacle. The reattachment point for the base separation is also a function of Mach number. As the Mach number is increased the reattachment point shifts toward the protuberances base. A weak recompression shock is also seen in the base, which affects the separated zone behind the protuberance. The important design parameters such as skin friction, heat transfer, drag, and surface pressure coefficients are reported extensively.
- 1 January 2012
- Published by Taylor & Francis in Engineering Applications of Computational Fluid Mechanics
- Vol. 6 (3) , 316-335
Open AccessAerodynamics Characteristic of Axisymmetric Surface Protuberance in Supersonic Regime
The present work deals with the problem of an axi-symmetric surface protuberance mounted on a spherical nosed body of revolution. The numerical computations are carried out for laminar supersonic viscous flow for trapezoidal shape axi-symmetric protuberances. A free stream Mach number ranging from 3 to 8 in steps of 1 at a fixed free stream Reynolds number of 1.8×104 has been used in the present study. The steady solutions are obtained using a time marching approach. A newly developed Particle Velocity Upwinding (PVU) scheme has been used for the computation. The spatial flow pattern exhibits a strong bow shock in front of the hemispherical nose, which engulfs the entire base body. Near the protuberance, the fluid particle decelerates due to the adverse pressure created by the protuberance and thus the flow separates in front of the protuberance. This point of separation is found to be a function of Mach number and the protuberance shape. A low-pressure expansion region dominates the base region of the obstacle. The reattachment point for the base separation is also a function of Mach number. As the Mach number is increased the reattachment point shifts toward the protuberances base. A weak recompression shock is also seen in the base, which affects the separated zone behind the protuberance. The important design parameters such as skin friction, heat transfer, drag, and surface pressure coefficients are reported extensively.