Simon Marmor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Simon Marmor has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
Vincent Le Strat
Department of Orthopaedic Surgery, Hospital La Croix-Saint Simon, 125, rue d'Avron, 75020, Paris, France
6 shared publicationsAntoine Mouton
Department of Orthopaedic Surgery, Hospital La Croix-Saint Simon, 125, rue d'Avron, 75020, Paris, France
5 shared publications- Thomas Aubert
Groupe Hospitalier Diaconesses Croix Saint Simon, 125 Rue d'Avron, Paris 75020, France
5 shared publications Wilfrid Graff
Department of Orthopaedic Surgery, Hospital La Croix-Saint Simon, 125, rue d'Avron, 75020, Paris, France
4 shared publicationsLuc Lhotellier
Department of Orthopedic Surgery, Groupe Hospitalier Diaconesses Croix Saint-Simon, Paris, France
3 shared publications- Valérie Zeller
Centre de Référence des Infections Ostéo-Articulaires Complexes, Groupe Hospitalier Diaconesses–Croix Saint-Simon, 125, rue d’Avron, 75020 Paris, France
3 shared publications
Latest Publications
- Open Access
- 3 December 2025
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 112 (1) , 104561
Management of patients on long-term oral anticoagulant therapy during primary total hip or knee replacement arthroplasty: A prospective non-interventional comparative study
- 3 December 2025
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 112 (1) , 104561
Open AccessManagement of patients on long-term oral anticoagulant therapy during primary total hip or knee replacement arthroplasty: A prospective non-interventional comparative study
- Open Access
- 17 October 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (5) , 1766-1775
Personalized alignment in total knee arthroplasty reduces patellar tilt: A retrospective study
Purpose: Patellofemoral kinematics is crucial for patient satisfaction following total knee arthroplasty (TKA). A postoperative patellar tilt greater than 5° has been associated with inferior clinical outcomes. While a femoral component external rotation beyond 3° is generally protective against patellar tilt, personalized alignment may not consistently reach this threshold. The aim of this study is to (1) assess the incidence of postoperative patellar tilt >5° following TKA with personalized alignment and (2) identify preoperative and intraoperative factors associated with this complication. Methods: This comparative retrospective study included 316 primary TKAs Attune (Johnson & Johnson®) performed between January and December 2024 using navigation or robotic assistance. All procedures were conducted at the same center by four surgeons: two using a subvastus approach and two a transquadricipital approach. Thirty‐six involving residents were excluded. Patellar tilt is defined as an angle exceeding 5° between a line drawn along the anterior borders of the femoral condyles and a line connecting the posterior edges of the medial and lateral patellar facets on a patellofemoral skyline view 3 months postoperatively. No patients were lost to follow‐up. To identify postoperative patellar risk factors, the following data were analyzed: Age, gender, body mass index, preoperative hip‐knee‐ankle angle, medial proximal tibial angle, lateral distal femoral angle, coronal plane alignment, functional knee phenotype, tibial slope, preoperative radiographic patellar tilt, range of motion, surgical approach, laterality, implant type (posterior‐stabilized or cruciate‐retaining), use of robotics or navigation, patellar resurfacing and patellar button size (if applicable). Results: Patellar tilt was observed in 11.8% of cases, a rate markedly lower than that reported for mechanical alignment in existing literature. Multivariate analysis identified the transquadricipital approach (odds ratio [OR]: 2.75; p = 0.02), right‐sided surgery (OR: 2.63; p = 0.02) and PS implants (OR: 2.59; p = 0.04) as independent risk factors. Conclusion: Personalized alignment, the subvastus approach, and cruciate‐retaining implants appear to reduce the risk of postoperative patellar tilt. Level of Evidence: Level III, retrospective cohort study.
- 17 October 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (5) , 1766-1775
Open AccessPersonalized alignment in total knee arthroplasty reduces patellar tilt: A retrospective study
Purpose: Patellofemoral kinematics is crucial for patient satisfaction following total knee arthroplasty (TKA). A postoperative patellar tilt greater than 5° has been associated with inferior clinical outcomes. While a femoral component external rotation beyond 3° is generally protective against patellar tilt, personalized alignment may not consistently reach this threshold. The aim of this study is to (1) assess the incidence of postoperative patellar tilt >5° following TKA with personalized alignment and (2) identify preoperative and intraoperative factors associated with this complication. Methods: This comparative retrospective study included 316 primary TKAs Attune (Johnson & Johnson®) performed between January and December 2024 using navigation or robotic assistance. All procedures were conducted at the same center by four surgeons: two using a subvastus approach and two a transquadricipital approach. Thirty‐six involving residents were excluded. Patellar tilt is defined as an angle exceeding 5° between a line drawn along the anterior borders of the femoral condyles and a line connecting the posterior edges of the medial and lateral patellar facets on a patellofemoral skyline view 3 months postoperatively. No patients were lost to follow‐up. To identify postoperative patellar risk factors, the following data were analyzed: Age, gender, body mass index, preoperative hip‐knee‐ankle angle, medial proximal tibial angle, lateral distal femoral angle, coronal plane alignment, functional knee phenotype, tibial slope, preoperative radiographic patellar tilt, range of motion, surgical approach, laterality, implant type (posterior‐stabilized or cruciate‐retaining), use of robotics or navigation, patellar resurfacing and patellar button size (if applicable). Results: Patellar tilt was observed in 11.8% of cases, a rate markedly lower than that reported for mechanical alignment in existing literature. Multivariate analysis identified the transquadricipital approach (odds ratio [OR]: 2.75; p = 0.02), right‐sided surgery (OR: 2.63; p = 0.02) and PS implants (OR: 2.59; p = 0.04) as independent risk factors. Conclusion: Personalized alignment, the subvastus approach, and cruciate‐retaining implants appear to reduce the risk of postoperative patellar tilt. Level of Evidence: Level III, retrospective cohort study.
- Open Access
- 1 July 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (3)
Short learning curve associated with robotic total knee arthroplasty: A retrospective study
Purpose: Robotic‐assisted total knee arthroplasty (RA‐TKA), which is increasingly used to improve surgical precision, can face adoption difficulties due to a learning curve marked by longer operating times. The aim of this study was to evaluate the learning curve associated with the VELYS™ robot in five surgeons from the same centre with different annual arthroplasty volumes using navigated assistance with personalised alignment. The primary aim was to assess the learning curve for each surgeon. Secondary aims were to identify the factors associated with extended operative times. Methods: In this retrospective comparative study, 367 patients who underwent primary TKA between January and December 2024 were included, comprising 149 with robotic assistance and 218 with navigated assistance. The surgical learning curve, based on skin‐to‐skin operating time, was assessed using the cumulative summation method. Five surgeons were evaluated: two high‐volume surgeons (>150 TKAs per year), a medium‐volume surgeon (between 50 and 150) and two low‐volume surgeons (p = 0.017) with navigation. The increase was statistically significant only for one low‐volume surgeon ( p = 0.008). Use of the robot ( p < 0.001), surgeon ( p < 0.001), use of a posterior‐stabilised implant ( p < 0.001) and varus of more than 10° ( p = 0.0191) were independent factors associated with extended operative time. Conclusion: The learning curve associated with VELYS™ was between 4 and 11 procedures. The small increase in operative time compared to navigation should not be a barrier to its adoption. Level of Evidence: Level III, case–control retrospective analysis.
- 1 July 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (3)
Open AccessShort learning curve associated with robotic total knee arthroplasty: A retrospective study
Purpose: Robotic‐assisted total knee arthroplasty (RA‐TKA), which is increasingly used to improve surgical precision, can face adoption difficulties due to a learning curve marked by longer operating times. The aim of this study was to evaluate the learning curve associated with the VELYS™ robot in five surgeons from the same centre with different annual arthroplasty volumes using navigated assistance with personalised alignment. The primary aim was to assess the learning curve for each surgeon. Secondary aims were to identify the factors associated with extended operative times. Methods: In this retrospective comparative study, 367 patients who underwent primary TKA between January and December 2024 were included, comprising 149 with robotic assistance and 218 with navigated assistance. The surgical learning curve, based on skin‐to‐skin operating time, was assessed using the cumulative summation method. Five surgeons were evaluated: two high‐volume surgeons (>150 TKAs per year), a medium‐volume surgeon (between 50 and 150) and two low‐volume surgeons (p = 0.017) with navigation. The increase was statistically significant only for one low‐volume surgeon ( p = 0.008). Use of the robot ( p < 0.001), surgeon ( p < 0.001), use of a posterior‐stabilised implant ( p < 0.001) and varus of more than 10° ( p = 0.0191) were independent factors associated with extended operative time. Conclusion: The learning curve associated with VELYS™ was between 4 and 11 procedures. The small increase in operative time compared to navigation should not be a barrier to its adoption. Level of Evidence: Level III, case–control retrospective analysis.
- 11 June 2025
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- p. 104315
Dislocation after anterior-approach THA: High prevalence of spinopelvic risk factors
- 11 June 2025
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- p. 104315
Dislocation after anterior-approach THA: High prevalence of spinopelvic risk factors
- 11 April 2025
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- p. 104243
Hip-resection arthroplasty: A valuable treatment for complex hip prosthetic joint infection?
- 11 April 2025
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- p. 104243
Hip-resection arthroplasty: A valuable treatment for complex hip prosthetic joint infection?
- Open Access
- 7 March 2025
- Published by EDP Sciences in SICOT-J
- Vol. 11, 13
Cutaneous metallosis following ceramic insert fracture in total hip arthroplasty: a case report and revision with ceramic-on-ceramic bearing couple
Ceramic fractures in total hip arthroplasty (THA) are rare complications that pose significant challenges for revision surgery. This case report describes a 68-year-old male who experienced a spontaneous alumina (ceramic) insert and head fracture four years after the initial THA. The first revision with cobalt-chrome and polyethylene components led to severe metallosis, including subcutaneous tissue discoloration. A second revision utilized a ceramic-on-ceramic (CoC) bearing couple, resulting in excellent functional outcomes and resolution of symptoms. Cutaneous pigmentation post-THA is rare and has not been previously reported following a ceramic fracture. The case underscores the need for careful material selection in revision surgery to minimize complications such as metallosis. The decision to use a ceramic-on-ceramic bearing couple in this case proved effective, ensuring durability and reducing the risk of third-body wear, which can result from inadequate management of ceramic fractures and lead to joint, systemic, or cutaneous complications.
- 7 March 2025
- Published by EDP Sciences in SICOT-J
- Vol. 11, 13
Open AccessCutaneous metallosis following ceramic insert fracture in total hip arthroplasty: a case report and revision with ceramic-on-ceramic bearing couple
Ceramic fractures in total hip arthroplasty (THA) are rare complications that pose significant challenges for revision surgery. This case report describes a 68-year-old male who experienced a spontaneous alumina (ceramic) insert and head fracture four years after the initial THA. The first revision with cobalt-chrome and polyethylene components led to severe metallosis, including subcutaneous tissue discoloration. A second revision utilized a ceramic-on-ceramic (CoC) bearing couple, resulting in excellent functional outcomes and resolution of symptoms. Cutaneous pigmentation post-THA is rare and has not been previously reported following a ceramic fracture. The case underscores the need for careful material selection in revision surgery to minimize complications such as metallosis. The decision to use a ceramic-on-ceramic bearing couple in this case proved effective, ensuring durability and reducing the risk of third-body wear, which can result from inadequate management of ceramic fractures and lead to joint, systemic, or cutaneous complications.
- 20 February 2023
- Published by Springer Nature in International Orthopaedics
- Vol. 47 (5) , 1197-1202
Revision total hip arthroplasty by a ceramic bearing surface after a third- and fourth-generation ceramic head or liner fracture
Purpose Although rare, fractures of ceramic components are difficult to revise, mainly due to the presence of residual ceramic debris that can cause catastrophic wear of the replacement components. Modern ceramic-on-ceramic bearings are suggested to improve outcomes of revision total hip arthroplasty (THA) for ceramic fractures. However, there are few published reports of mid-term outcomes of revision THA using ceramic-on-ceramic bearings. We evaluated clinical and radiographic outcomes of 10 patients who received ceramic-on-ceramic bearings during revision THA for ceramic fractures. Methods All patients but one received fourth-generation Biolox Delta bearings. Clinical evaluation was performed using the Harris hip score at latest follow-up, and all patients received a radiographic evaluation to analyze the fixation of the acetabular cup and of the femoral stem. Osteolytic lesions and the presence of ceramic debris were noted. Results After a mean follow-up of 8.0 years, there were no complications or implant failures, and all patients reported satisfaction with their implant. The average Harris hip score was 90.6. There was neither osteolysis nor loosening, but despite our extensive synovial debridement, ceramic debris was noted in the radiographs of five patients (50%). Conclusion We report excellent mid-term outcomes, with no implant failures after eight years despite ceramic debris being found in a significant proportion of patients. We conclude that modern ceramic-on-ceramic bearings are an advantageous option for the revision of THA due to the fracture of initial ceramic components.
- 20 February 2023
- Published by Springer Nature in International Orthopaedics
- Vol. 47 (5) , 1197-1202
Revision total hip arthroplasty by a ceramic bearing surface after a third- and fourth-generation ceramic head or liner fracture
Purpose Although rare, fractures of ceramic components are difficult to revise, mainly due to the presence of residual ceramic debris that can cause catastrophic wear of the replacement components. Modern ceramic-on-ceramic bearings are suggested to improve outcomes of revision total hip arthroplasty (THA) for ceramic fractures. However, there are few published reports of mid-term outcomes of revision THA using ceramic-on-ceramic bearings. We evaluated clinical and radiographic outcomes of 10 patients who received ceramic-on-ceramic bearings during revision THA for ceramic fractures. Methods All patients but one received fourth-generation Biolox Delta bearings. Clinical evaluation was performed using the Harris hip score at latest follow-up, and all patients received a radiographic evaluation to analyze the fixation of the acetabular cup and of the femoral stem. Osteolytic lesions and the presence of ceramic debris were noted. Results After a mean follow-up of 8.0 years, there were no complications or implant failures, and all patients reported satisfaction with their implant. The average Harris hip score was 90.6. There was neither osteolysis nor loosening, but despite our extensive synovial debridement, ceramic debris was noted in the radiographs of five patients (50%). Conclusion We report excellent mid-term outcomes, with no implant failures after eight years despite ceramic debris being found in a significant proportion of patients. We conclude that modern ceramic-on-ceramic bearings are an advantageous option for the revision of THA due to the fracture of initial ceramic components.
- Open Access
- 11 December 2022
- Published by MDPI AG in Antibiotics
- Vol. 11 (12) , 1801
Cutibacterium acnes Prosthetic Joint Infections: Is Rifampicin-Combination Therapy Beneficial?
No consensus has been reached on the optimal antibiotic regimen to treat Cutibacterium acnes PJIs (Ca-PJIs). In vitro studies showed excellent rifampicin efficacy against biofilm-associated C. acnes infections, but clinical studies did not confirm the superiority of rifampicin-combined therapy over monotherapy. This prospective cohort study was undertaken to analyze the outcomes of 70 patients who underwent exchange arthroplasty for chronic monomicrobial Ca-PJI and were treated with rifampicin or without between 2004 and 2019. The 37 patients treated from January 2004 to August 2014 were prescribed rifampicin-combination therapy and the 33 treated from September 2014 to December 2019 received monotherapy without rifampicin. The primary endpoint was the 2-year Kaplan–Meier-estimated reinfection-free probability, including relapses and new-pathogen PJIs. The 2-year reinfection-free rate was high and not different for patients who had received rifampicin or not (89.2% vs. 93.8%, respectively; p = 0.524). None of the patients relapsed and six developed new-pathogen PJIs. Our results do not support a benefit of rifampicin-combination therapy for patients who underwent exchange arthroplasty for chronic Ca-PJIs.
- 11 December 2022
- Published by MDPI AG in Antibiotics
- Vol. 11 (12) , 1801
Open AccessCutibacterium acnes Prosthetic Joint Infections: Is Rifampicin-Combination Therapy Beneficial?
No consensus has been reached on the optimal antibiotic regimen to treat Cutibacterium acnes PJIs (Ca-PJIs). In vitro studies showed excellent rifampicin efficacy against biofilm-associated C. acnes infections, but clinical studies did not confirm the superiority of rifampicin-combined therapy over monotherapy. This prospective cohort study was undertaken to analyze the outcomes of 70 patients who underwent exchange arthroplasty for chronic monomicrobial Ca-PJI and were treated with rifampicin or without between 2004 and 2019. The 37 patients treated from January 2004 to August 2014 were prescribed rifampicin-combination therapy and the 33 treated from September 2014 to December 2019 received monotherapy without rifampicin. The primary endpoint was the 2-year Kaplan–Meier-estimated reinfection-free probability, including relapses and new-pathogen PJIs. The 2-year reinfection-free rate was high and not different for patients who had received rifampicin or not (89.2% vs. 93.8%, respectively; p = 0.524). None of the patients relapsed and six developed new-pathogen PJIs. Our results do not support a benefit of rifampicin-combination therapy for patients who underwent exchange arthroplasty for chronic Ca-PJIs.
- Open Access
- 23 October 2022
- Published by MDPI AG in Antibiotics
- Vol. 11 (11) , 1462
Population Pharmacokinetics of Orally Administered Clindamycin to Treat Prosthetic Joint Infections: A Prospective Study
A population PK model of clindamycin orally administered to patients with prosthetic joint infections (PJIs) was developed using NONMEM 7.5. Monte-Carlo simulations were run to determine the probability of obtaining bone clindamycin concentrations equal to at least the MIC or four times the MIC for several MIC values and dosing regimens. One hundred and forty plasma concentrations prospectively obtained from 20 patients with PJIs were used. A one-compartment model with first-order absorption and elimination appropriately described the data. Mean PK-parameter estimates (F being the bioavailability) were: apparent clearance, CL/F = 23 L/h, apparent distribution volume, V/F = 103 l and absorption rate constant, Ka = 3.53/h, with respective interindividual variabilities (coefficients of variation) of 14.4%, 8.2% and 59.6%. Neither goodness-of-fit curves nor visual predictive checks indicated bias. The currently recommended 600 mg q8h regimen provided a high probability of obtaining concentrations equal to at least the MIC, except for MIC ≥ the clinical breakpoint for Staphylococcus spp. (0.25 mg/L). For such MIC values, higher daily doses and q6h regimens could be considered.
- 23 October 2022
- Published by MDPI AG in Antibiotics
- Vol. 11 (11) , 1462
Open AccessPopulation Pharmacokinetics of Orally Administered Clindamycin to Treat Prosthetic Joint Infections: A Prospective Study
A population PK model of clindamycin orally administered to patients with prosthetic joint infections (PJIs) was developed using NONMEM 7.5. Monte-Carlo simulations were run to determine the probability of obtaining bone clindamycin concentrations equal to at least the MIC or four times the MIC for several MIC values and dosing regimens. One hundred and forty plasma concentrations prospectively obtained from 20 patients with PJIs were used. A one-compartment model with first-order absorption and elimination appropriately described the data. Mean PK-parameter estimates (F being the bioavailability) were: apparent clearance, CL/F = 23 L/h, apparent distribution volume, V/F = 103 l and absorption rate constant, Ka = 3.53/h, with respective interindividual variabilities (coefficients of variation) of 14.4%, 8.2% and 59.6%. Neither goodness-of-fit curves nor visual predictive checks indicated bias. The currently recommended 600 mg q8h regimen provided a high probability of obtaining concentrations equal to at least the MIC, except for MIC ≥ the clinical breakpoint for Staphylococcus spp. (0.25 mg/L). For such MIC values, higher daily doses and q6h regimens could be considered.