Sreeja Balakrishnapillai Suseela
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sreeja Balakrishnapillai Suseela has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
Radha Sankararajan
Department of Electronics and Communication Engineering, SSN College of Engineering, Chennai, India
9 shared publications- Shankararajan Radha
Department of Electronics and Communication Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, India
5 shared publications Pratap Kumar
Anna University Chennai India
4 shared publicationsE. Manikandan
Department of ECE, B.S. Abdur Rahman Crescent Institute of Science and Technology, Chennai, India
3 shared publicationsNafiza Noorullakhan
Department of Electronics and Communication Engineering SSN College of Engineering, Kalavakkam Chennai Tamil Nadu 603110 India
3 shared publicationsS. Radha
Sri Sivasubramaniya Nadar College of Engineering
3 shared publications
Latest Publications
- 14 September 2026
- Published by Springer Nature in Applied Physics A
- Vol. 132 (10) , 1015
Flexible sugarcane bagasse-derived CNF/PVDF/PVA piezoelectric pressure sensor for real-time plantar pressure monitoring
- 14 September 2026
- Published by Springer Nature in Applied Physics A
- Vol. 132 (10) , 1015
Flexible sugarcane bagasse-derived CNF/PVDF/PVA piezoelectric pressure sensor for real-time plantar pressure monitoring
- 1 July 2026
- Published by Springer Nature in Microsystem Technologies
- Vol. 32 (8) , 109
Advances in MEMS fabrication: a comprehensive review of techniques, trends, and challenges
- 1 July 2026
- Published by Springer Nature in Microsystem Technologies
- Vol. 32 (8) , 109
Advances in MEMS fabrication: a comprehensive review of techniques, trends, and challenges
- Open Access
- 29 May 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (6) , 676
3D-Printing-Assisted Fabrication and Characterization of Pregabalin-Loaded PVA/PVP Dissolving Microneedle Arrays
Background: A transdermal drug delivery system has significant benefits over conventional routes; however, its effectiveness is limited by the barrier properties of the stratum corneum. Dissolving microneedles (DMNs) have emerged as a minimally invasive strategy to enhance drug permeation while improving patient compliance. The integration of advanced fabrication techniques such as 3D printing enables precise control over microneedle geometry and reproducibility. Objective: This study aimed to fabricate and characterize pregabalin-loaded PVA/PVP dissolving microneedle arrays using a 3D-printing-assisted mold fabrication approach for efficient transdermal drug delivery. Methods: Microneedle master molds were fabricated using 3D printing, followed by replication using polydimethylsiloxane (PDMS) to obtain negative molds. Pregabalin-loaded bilayer microneedles were prepared using a micromolding technique with PVA/PVP polymers. The formulation was evaluated through rheological analysis, scanning electron microscopy (SEM), mechanical strength testing, insertion studies, swelling behavior, drug loading efficiency, Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), X-ray diffraction (XRD), and in vitro drug release studies. Results: The fabricated microneedles exhibited uniform geometry with sharp tips and no structural defects. Rheological analysis confirmed shear-thinning behavior suitable for mold filling. The microneedles demonstrated adequate mechanical strength (~3.3 N/needle) and efficient insertion into the parafilm model. Drug loading efficiency was high (92.4%), indicating effective encapsulation. FTIR analysis confirmed compatibility between drug and polymers, while DSC and XRD results indicated partial amorphization of pregabalin within the polymer matrix. The formulation showed a biphasic drug release profile with an initial burst followed by sustained release, achieving ~96.8% cumulative release over 24 h. Conclusions: The study successfully demonstrates a robust and reproducible 3D-printing-assisted approach for fabricating pregabalin-loaded dissolving microneedles. The developed system exhibited desirable mechanical, physicochemical, and drug release properties, highlighting its potential as an effective transdermal drug delivery platform.
- 29 May 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (6) , 676
Open Access3D-Printing-Assisted Fabrication and Characterization of Pregabalin-Loaded PVA/PVP Dissolving Microneedle Arrays
Background: A transdermal drug delivery system has significant benefits over conventional routes; however, its effectiveness is limited by the barrier properties of the stratum corneum. Dissolving microneedles (DMNs) have emerged as a minimally invasive strategy to enhance drug permeation while improving patient compliance. The integration of advanced fabrication techniques such as 3D printing enables precise control over microneedle geometry and reproducibility. Objective: This study aimed to fabricate and characterize pregabalin-loaded PVA/PVP dissolving microneedle arrays using a 3D-printing-assisted mold fabrication approach for efficient transdermal drug delivery. Methods: Microneedle master molds were fabricated using 3D printing, followed by replication using polydimethylsiloxane (PDMS) to obtain negative molds. Pregabalin-loaded bilayer microneedles were prepared using a micromolding technique with PVA/PVP polymers. The formulation was evaluated through rheological analysis, scanning electron microscopy (SEM), mechanical strength testing, insertion studies, swelling behavior, drug loading efficiency, Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), X-ray diffraction (XRD), and in vitro drug release studies. Results: The fabricated microneedles exhibited uniform geometry with sharp tips and no structural defects. Rheological analysis confirmed shear-thinning behavior suitable for mold filling. The microneedles demonstrated adequate mechanical strength (~3.3 N/needle) and efficient insertion into the parafilm model. Drug loading efficiency was high (92.4%), indicating effective encapsulation. FTIR analysis confirmed compatibility between drug and polymers, while DSC and XRD results indicated partial amorphization of pregabalin within the polymer matrix. The formulation showed a biphasic drug release profile with an initial burst followed by sustained release, achieving ~96.8% cumulative release over 24 h. Conclusions: The study successfully demonstrates a robust and reproducible 3D-printing-assisted approach for fabricating pregabalin-loaded dissolving microneedles. The developed system exhibited desirable mechanical, physicochemical, and drug release properties, highlighting its potential as an effective transdermal drug delivery platform.
- 5 January 2026
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 30 (2) , 10
A review on advanced nanocomposite-based electrochemical biosensors for healthcare monitoring using human sweat
- 5 January 2026
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 30 (2) , 10
A review on advanced nanocomposite-based electrochemical biosensors for healthcare monitoring using human sweat
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (2) , 1-4
Development of Electrochemical Sensors for Blood Glucose Detection With Wide Range Using MWCNT–Chitosan—A Microneedle Approach
In this study, we developed electrochemical sensors for detecting blood glucose levels in interstitial fluid over a wide range (0–30 mM) by using a nonenzymatic approach with the nanomaterial MWCNT–chitosan as the glucose-sensing material and incorporating a microneedle for a minimally invasive method. In this method, the sensing principle includes a three-electrode system. The sensor was designed to resemble a screen-printed electrode with a novel microneedle incorporated onto the surface of the electrode. The fabrication process includes a 3-D printing technique followed by the formulation of graphite conductive ink and working-electrode modification with the glucose-sensing material MWCNT–chitosan. Electrochemical characterization studies, such as cyclic voltammetry (CV) and linear sweep voltammetry (LSV), were performed for the MWCNT-chitosan-modified working electrode against Ag/AgCl used as the reference electrode. The measured sensitivity values were 52.44 and 4.224 μA mM−1 cm−2, limit of detection calculated to be 0.2187 mM and 0.2705 mM using CV and LSV, respectively. To determine the high selectivity toward glucose, an in vitro interference test was performed using common interferents.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (2) , 1-4
Development of Electrochemical Sensors for Blood Glucose Detection With Wide Range Using MWCNT–Chitosan—A Microneedle Approach
In this study, we developed electrochemical sensors for detecting blood glucose levels in interstitial fluid over a wide range (0–30 mM) by using a nonenzymatic approach with the nanomaterial MWCNT–chitosan as the glucose-sensing material and incorporating a microneedle for a minimally invasive method. In this method, the sensing principle includes a three-electrode system. The sensor was designed to resemble a screen-printed electrode with a novel microneedle incorporated onto the surface of the electrode. The fabrication process includes a 3-D printing technique followed by the formulation of graphite conductive ink and working-electrode modification with the glucose-sensing material MWCNT–chitosan. Electrochemical characterization studies, such as cyclic voltammetry (CV) and linear sweep voltammetry (LSV), were performed for the MWCNT-chitosan-modified working electrode against Ag/AgCl used as the reference electrode. The measured sensitivity values were 52.44 and 4.224 μA mM−1 cm−2, limit of detection calculated to be 0.2187 mM and 0.2705 mM using CV and LSV, respectively. To determine the high selectivity toward glucose, an in vitro interference test was performed using common interferents.
- 15 October 2025
- Published by Springer Nature in Biomedical Materials & Devices
- Vol. 4 (4) , 1-25
Materials, Design, and Innovations in Flexible Pressure Sensors for Biomedical Applications: A Review
- 15 October 2025
- Published by Springer Nature in Biomedical Materials & Devices
- Vol. 4 (4) , 1-25
Materials, Design, and Innovations in Flexible Pressure Sensors for Biomedical Applications: A Review
- 26 September 2025
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 36 (27) , 1-23
Reduced graphene oxide/polyaniline hydrogel-based piezo pressure sensor for biomedical applications
- 26 September 2025
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 36 (27) , 1-23
Reduced graphene oxide/polyaniline hydrogel-based piezo pressure sensor for biomedical applications
- Open Access
- 1 July 2025
- Published by Springer Nature in Microsystem Technologies
- Vol. 31 (8) , 1875-1896
A systematic review of disposable biosensors: recent developments and future perspectives
- 1 July 2025
- Published by Springer Nature in Microsystem Technologies
- Vol. 31 (8) , 1875-1896
Open AccessA systematic review of disposable biosensors: recent developments and future perspectives
- 16 January 2025
- Published by Wiley in International Journal of Communication Systems
- Vol. 38 (4)
Omnidirectional to Directional Pattern Switching Patch Antenna for Wireless Sensor Nodes at Nuclear Reactor Containment Building
The novel design, prototyping, and characterization of an omnidirectional to directional radiation pattern switching planar antenna system are presented. The incorporation of the Yagi‐Uda antenna with an Alford loop antenna is proposed. The antenna is formed by a dipole, driver, reflector, and two directors. In a DC bias switching circuit with a combination of eight SMD PIN diodes and two parasitic elements, the antenna's radiation patterns can be shaped to concentrate energy in an omnidirectional radiation pattern. The introduction of switches using an SMD PIN diode at the arms of the driver element produces two switchable frequencies at 915 MHz and 2.45 GHz. Switches at the directors and reflector control the radiation pattern and can be configured to omnidirectional pattern to directional radiation pattern at those resonance frequencies. The radiation patterns as well as the simulated and measured reflection coefficients (S11) are illustrated and analyzed. Return loss (S11) is observed to be −36.36 dB at resonance frequency of 2.45 GHz (2.35–2.69 GHz) with bandwidth 340 MHz and impedance bandwidth 21.1%, and −24.45 dB at resonance frequency of 915 MHz (854–1006 MHz) with bandwidth 152 MHz and impedance bandwidth 16.61%. When compared with the omnidirectional pattern while maintaining the horizontal polarization, the gain of the antenna increases from 4.6 dBi with 90.02% efficiency to 5.1 dB with 87.77% efficiency in a directional pattern. The developed antenna system's final dimensions are 2.45 λ × 1.80 λ × 0.01 λ. The antenna system is tested in a nuclear reactor containment building equipped with a wireless sensor node. The signal transmission indicates the zero (0) invalid frames with 100 dBm received signal strength indication (RSSI). The printable nature of the antenna architecture and successful transmission of signals across the nuclear reactor containment building make the antenna a good candidate for the wireless sensor node (WSN) in the nuclear reactor.
- 16 January 2025
- Published by Wiley in International Journal of Communication Systems
- Vol. 38 (4)
Omnidirectional to Directional Pattern Switching Patch Antenna for Wireless Sensor Nodes at Nuclear Reactor Containment Building
The novel design, prototyping, and characterization of an omnidirectional to directional radiation pattern switching planar antenna system are presented. The incorporation of the Yagi‐Uda antenna with an Alford loop antenna is proposed. The antenna is formed by a dipole, driver, reflector, and two directors. In a DC bias switching circuit with a combination of eight SMD PIN diodes and two parasitic elements, the antenna's radiation patterns can be shaped to concentrate energy in an omnidirectional radiation pattern. The introduction of switches using an SMD PIN diode at the arms of the driver element produces two switchable frequencies at 915 MHz and 2.45 GHz. Switches at the directors and reflector control the radiation pattern and can be configured to omnidirectional pattern to directional radiation pattern at those resonance frequencies. The radiation patterns as well as the simulated and measured reflection coefficients (S11) are illustrated and analyzed. Return loss (S11) is observed to be −36.36 dB at resonance frequency of 2.45 GHz (2.35–2.69 GHz) with bandwidth 340 MHz and impedance bandwidth 21.1%, and −24.45 dB at resonance frequency of 915 MHz (854–1006 MHz) with bandwidth 152 MHz and impedance bandwidth 16.61%. When compared with the omnidirectional pattern while maintaining the horizontal polarization, the gain of the antenna increases from 4.6 dBi with 90.02% efficiency to 5.1 dB with 87.77% efficiency in a directional pattern. The developed antenna system's final dimensions are 2.45 λ × 1.80 λ × 0.01 λ. The antenna system is tested in a nuclear reactor containment building equipped with a wireless sensor node. The signal transmission indicates the zero (0) invalid frames with 100 dBm received signal strength indication (RSSI). The printable nature of the antenna architecture and successful transmission of signals across the nuclear reactor containment building make the antenna a good candidate for the wireless sensor node (WSN) in the nuclear reactor.
- 9 October 2024
- Published by Springer Nature in Microsystem Technologies
- Vol. 31 (6) , 1259-1288
Comprehensive overview of microfluidic flow sensors: principles, materials, and fabrication
- 9 October 2024
- Published by Springer Nature in Microsystem Technologies
- Vol. 31 (6) , 1259-1288
Comprehensive overview of microfluidic flow sensors: principles, materials, and fabrication