Manuel Loesch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Manuel Loesch has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Hartmut Schmeck
Karlsruhe Institute of Technology (KIT)
4 shared publications Hartmut Schmeck
Karlsruhe Institute of Technology Institute of Applied Informatics and Formal Description Methods Kaiserstr. 89,Karlsruhe,Germany,76133
3 shared publicationsJulian Rominger
FZI Research Center for Information Technology Haid-und-Neu-Str. 10-14,Karlsruhe,Germany,76131
3 shared publications- Kevin Förderer
Institute for Automation and Applied Informatics, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
2 shared publications - Rouven Krebs
SAP SE
2 shared publications Sebastian Steuer
FZI Research Center for Information Technology Haid-und-Neu-Str. 10-14,Karlsruhe,Germany,76131
2 shared publications
Latest Publications
- Open Access
- 26 May 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (11) , 3665
State-of-the-Art Integration of Decentralized Energy Management Systems into the German Smart Meter Gateway Infrastructure
The German Smart Meter Gateway (SMGW) infrastructure enables digital access to metering data and distributed energy resources by external parties. There are, however, various restrictions in order to guarantee the privacy of consumers, and strong security requirements. Furthermore, in the current state of development, there are still several challenges to overcome in order to implement demand side management (DSM) measures. In this paper, we present a prototype enabling DSM measures within the SMGW infrastructure, using the smart grid traffic light concept. The prototype implements an automated decentralized energy management system (EMS) that optimally controls an electric vehicle charging station. In the development of this prototype, we did not only evaluate five of the seven available SMGW devices, but also push the limits of the infrastructure itself. The experiments demonstrated the successful implementation of the intended DSM measure by the EMS. Even though there are technical guidelines standardizing the functionality of SMGWs, our evaluation shows that there are substantial differences between the individual SMGW devices.
- 26 May 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (11) , 3665
Open AccessState-of-the-Art Integration of Decentralized Energy Management Systems into the German Smart Meter Gateway Infrastructure
The German Smart Meter Gateway (SMGW) infrastructure enables digital access to metering data and distributed energy resources by external parties. There are, however, various restrictions in order to guarantee the privacy of consumers, and strong security requirements. Furthermore, in the current state of development, there are still several challenges to overcome in order to implement demand side management (DSM) measures. In this paper, we present a prototype enabling DSM measures within the SMGW infrastructure, using the smart grid traffic light concept. The prototype implements an automated decentralized energy management system (EMS) that optimally controls an electric vehicle charging station. In the development of this prototype, we did not only evaluate five of the seven available SMGW devices, but also push the limits of the infrastructure itself. The experiments demonstrated the successful implementation of the intended DSM measure by the EMS. Even though there are technical guidelines standardizing the functionality of SMGWs, our evaluation shows that there are substantial differences between the individual SMGW devices.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis of the German Continuous Intraday Market and the Revenue Potential for Flexibility Options
As the share of energy from fluctuating renewable energy resources traded on the German power spot markets has risen over the past years, energy prices on these markets have become more volatile. Therefore, the opportunities for utilizing the flexibility of energy demand or supply to gain monetary benefits have increased significantly. Especially the EPEX Intraday Continuous power market appears to be a favorable market place for demand- and supply-side flexibility options as continuously changing prices for power products offer the possibility to profit from consecutive rescheduling up to only five minutes before delivery. The contribution of this paper is twofold. Firstly, we provide an analysis of the development of the German Intraday Continuous power market over the years 2015 to 2017, and secondly, we quantify the revenue potential for different flexibility options participating in this market. The results of this work show an increasing revenue potential over the course of the three years. The revenues equal up to 3.4 times the wholesale energy costs for solely consuming and up to 12.4 times for consuming and generating flexibility options.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis of the German Continuous Intraday Market and the Revenue Potential for Flexibility Options
As the share of energy from fluctuating renewable energy resources traded on the German power spot markets has risen over the past years, energy prices on these markets have become more volatile. Therefore, the opportunities for utilizing the flexibility of energy demand or supply to gain monetary benefits have increased significantly. Especially the EPEX Intraday Continuous power market appears to be a favorable market place for demand- and supply-side flexibility options as continuously changing prices for power products offer the possibility to profit from consecutive rescheduling up to only five minutes before delivery. The contribution of this paper is twofold. Firstly, we provide an analysis of the development of the German Intraday Continuous power market over the years 2015 to 2017, and secondly, we quantify the revenue potential for different flexibility options participating in this market. The results of this work show an increasing revenue potential over the course of the three years. The revenues equal up to 3.4 times the wholesale energy costs for solely consuming and up to 12.4 times for consuming and generating flexibility options.
- Open Access
- 19 April 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (8) , 1634
Smart Meter Gateways: Options for a BSI-Compliant Integration of Energy Management Systems
The introduction of Smart Meter Gateways (SMGWs) to buildings and households creates new opportunities and challenges for energy management systems. While SMGWs provide interfaces for accessing recorded information and enable communication to external parties, they also restrict data access to protect the privacy of inhabitants and facility owners. This paper presents an analysis of options for integrating automated (Building) Energy Management Systems (EMSs) into the smart meter architecture based on the technical guidelines for SMGWs by the German Federal Office for Information Security (“Bundesamt für Sicherheit in der Informationstechnik”, BSI). It shows that there are multiple ways for integrating automated EMSs into the German smart metering architecture, although each option comes with its own advantages and restrictions. By providing a detailed discussion of trade-offs, this paper supports EMS designers that will be confronted with differing freedoms and limitations depending on the integration option.
- 19 April 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (8) , 1634
Open AccessSmart Meter Gateways: Options for a BSI-Compliant Integration of Energy Management Systems
The introduction of Smart Meter Gateways (SMGWs) to buildings and households creates new opportunities and challenges for energy management systems. While SMGWs provide interfaces for accessing recorded information and enable communication to external parties, they also restrict data access to protect the privacy of inhabitants and facility owners. This paper presents an analysis of options for integrating automated (Building) Energy Management Systems (EMSs) into the smart meter architecture based on the technical guidelines for SMGWs by the German Federal Office for Information Security (“Bundesamt für Sicherheit in der Informationstechnik”, BSI). It shows that there are multiple ways for integrating automated EMSs into the German smart metering architecture, although each option comes with its own advantages and restrictions. By providing a detailed discussion of trade-offs, this paper supports EMS designers that will be confronted with differing freedoms and limitations depending on the integration option.
- Open Access
- 1 November 2018
- Published by Elsevier in Energy Procedia
- Vol. 155, 443-453
Utilization of Local Flexibility for Charge Management of a Battery Energy Storage System Providing Frequency Containment Reserve
- 1 November 2018
- Published by Elsevier in Energy Procedia
- Vol. 155, 443-453
Open AccessUtilization of Local Flexibility for Charge Management of a Battery Energy Storage System Providing Frequency Containment Reserve
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Optimizing Bidding Strategies for the German Secondary Control Reserve Market: The Impact of Energy Prices
In the synchronized European grid, Secondary Control Reserve (SCR) is a key component to restore a stable grid frequency of 50 Hz. The German SCR market is based on a capacity price and an energy price. After being accepted into the reserve pool based on the capacity price, the energy price determines the position in the call merit order, and hence the probability of an activation. In this paper we present results of an ex-post simulation of the SCR market, based on publicly available data. Using our simulation, we quantified the share of SCR bid activations given different energy prices, and derived the profit potential for SCR providers. In addition, we investigated the development over the last years, recognizing that in particular positive SCR bids with a given energy price tend to be activated less often. By providing transparency regarding the relation between reserve energy prices and the share of activations, the insights presented in this paper can be used by balancing service providers in order to improve their SCR bids, or to validate the quality of bidding strategies of SCR aggregators.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Optimizing Bidding Strategies for the German Secondary Control Reserve Market: The Impact of Energy Prices
In the synchronized European grid, Secondary Control Reserve (SCR) is a key component to restore a stable grid frequency of 50 Hz. The German SCR market is based on a capacity price and an energy price. After being accepted into the reserve pool based on the capacity price, the energy price determines the position in the call merit order, and hence the probability of an activation. In this paper we present results of an ex-post simulation of the SCR market, based on publicly available data. Using our simulation, we quantified the share of SCR bid activations given different energy prices, and derived the profit potential for SCR providers. In addition, we investigated the development over the last years, recognizing that in particular positive SCR bids with a given energy price tend to be activated less often. By providing transparency regarding the relation between reserve energy prices and the share of activations, the insights presented in this paper can be used by balancing service providers in order to improve their SCR bids, or to validate the quality of bidding strategies of SCR aggregators.
- Open Access
- 3 June 2015
- Published by Riga Technical University
- p. 132-141
Simulation Study of a Heuristic Predictive Optimization Scheme for Grid-Reactive Heat Pump Operation
Simulation Study of a Heuristic Predictive Optimization Scheme for Grid-Reactive Heat Pump Operation
- 3 June 2015
- Published by Riga Technical University
- p. 132-141
Open AccessSimulation Study of a Heuristic Predictive Optimization Scheme for Grid-Reactive Heat Pump Operation
Simulation Study of a Heuristic Predictive Optimization Scheme for Grid-Reactive Heat Pump Operation
- 1 January 2015
- Published by Springer Nature
- p. 95-112
Building Energy Management in the FZI House of Living Labs
- 1 January 2015
- Published by Springer Nature
- p. 95-112
Building Energy Management in the FZI House of Living Labs
- 12 September 2014
- Published by Springer Nature
- p. 103-113
Locations for Performance Ensuring Admission Control in Load Balanced Multi-tenant Systems
- 12 September 2014
- Published by Springer Nature
- p. 103-113
Locations for Performance Ensuring Admission Control in Load Balanced Multi-tenant Systems
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (21596182) , 914-921
Platform-as-a-Service Architecture for Performance Isolated Multi-tenant Applications
Software-as-a-Service (SaaS) often shares one single application instance among different tenants to reduce costs. However, sharing potentially leads to undesired influence from one tenant onto the performance observed by the others. This is a significant problem as performance is one of the major obstacles for cloud customers. The application does intentionally not manage hardware resources, and the operating system is not aware of application level entities like tenants which makes the performance control a challenge. In case the SaaS is hosted on a Platform-as-a-Service (PaaS), the SaaS developer usually wants to control performance-related issues according to individual needs, and available information is even more limited. Thus, it is difficult to control the performance of different tenants to keep them isolated. Existing work focuses on concrete methods to provide performance isolation in systems where the whole stack is under control. In this paper we present a concrete PaaS enhancement which enables application developers to realize isolation methods for their hosted SaaS application. In a case study we evaluated the applicability and effectiveness of the enhancement in different environments.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (21596182) , 914-921
Platform-as-a-Service Architecture for Performance Isolated Multi-tenant Applications
Software-as-a-Service (SaaS) often shares one single application instance among different tenants to reduce costs. However, sharing potentially leads to undesired influence from one tenant onto the performance observed by the others. This is a significant problem as performance is one of the major obstacles for cloud customers. The application does intentionally not manage hardware resources, and the operating system is not aware of application level entities like tenants which makes the performance control a challenge. In case the SaaS is hosted on a Platform-as-a-Service (PaaS), the SaaS developer usually wants to control performance-related issues according to individual needs, and available information is even more limited. Thus, it is difficult to control the performance of different tenants to keep them isolated. Existing work focuses on concrete methods to provide performance isolation in systems where the whole stack is under control. In this paper we present a concrete PaaS enhancement which enables application developers to realize isolation methods for their hosted SaaS application. In a case study we evaluated the applicability and effectiveness of the enhancement in different environments.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Demand side management in smart buildings by intelligent scheduling of heat pumps
A major component of the future Smart Grid is an adaptive demand side that allows to handle the fluctuating power supply based on renewable energies. In this paper, we present an evolutionary algorithm that allows for shifting electrical loads generated by heat pumps. Our approach is based on overheating the hot water storage in order to get a higher degree of freedom for scheduling. In our scenario, we assume time-variable price and load limitation signals as well as a prediction for local power generation from photovoltaic panels to incentivize the load shifting. Using these signals, we consider the future thermal demand to schedule the heat pump such that electricity costs are decreased. Our simulations show that heat pumps and hot water storages bear potential to shift loads over a time span of up to multiple hours, thus providing economical storage capacity. In doing so and based on electricity prices from the stock exchange, we were able to significantly decrease electricity costs for operating the heat pump.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Demand side management in smart buildings by intelligent scheduling of heat pumps
A major component of the future Smart Grid is an adaptive demand side that allows to handle the fluctuating power supply based on renewable energies. In this paper, we present an evolutionary algorithm that allows for shifting electrical loads generated by heat pumps. Our approach is based on overheating the hot water storage in order to get a higher degree of freedom for scheduling. In our scenario, we assume time-variable price and load limitation signals as well as a prediction for local power generation from photovoltaic panels to incentivize the load shifting. Using these signals, we consider the future thermal demand to schedule the heat pump such that electricity costs are decreased. Our simulations show that heat pumps and hot water storages bear potential to shift loads over a time span of up to multiple hours, thus providing economical storage capacity. In doing so and based on electricity prices from the stock exchange, we were able to significantly decrease electricity costs for operating the heat pump.