Dong-Kwon Lim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dong-Kwon Lim has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Dinesh Kumar
Division of Mechanical Design Engineering, Jeonbuk National University, Jeonju 54896, Republic of Korea
1 shared publication Jeon Woong Kang
Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, and ‡Department of Mechanical and Biological Engineering, Massachusetts Institute of Technology , Cambridge, Massachusetts 02139, United States
1 shared publicationPeter T. C. So
‡Department of Mechanical and Biological Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
1 shared publicationRamachandra R. Dasari
†Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Cambridge, Massachusetts 02139, United States
1 shared publicationSandeep Kaur
Department of BIN Fusion Technology
1 shared publication
Latest Publications
- 3 February 2015
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 15 (3) , 1766-1772
High Resolution Live Cell Raman Imaging Using Subcellular Organelle-Targeting SERS-Sensitive Gold Nanoparticles with Highly Narrow Intra-Nanogap
We report a method to achieve high speed and high resolution live cell Raman images using small spherical gold nanoparticles with highly narrow intra-nanogap structures responding to NIR excitation (785 nm) and high-speed confocal Raman microscopy. The three different Raman-active molecules placed in the narrow intra-nanogap showed a strong and uniform Raman intensity in solution even under transient exposure time (10 ms) and low input power of incident laser (200 μW), which lead to obtain high-resolution single cell image within 30 s without inducing significant cell damage. The high resolution Raman image showed the distributions of gold nanoparticles for their targeted sites such as cytoplasm, mitochondria, or nucleus. The high speed Raman-based live cell imaging allowed us to monitor rapidly changing cell morphologies during cell death induced by the addition of highly toxic KCN solution to cells. These results strongly suggest that the use of SERS-active nanoparticle can greatly improve the current temporal resolution and image quality of Raman-based cell images enough to obtain the detailed cell dynamics and/or the responses of cells to potential drug molecules.
- 3 February 2015
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 15 (3) , 1766-1772
High Resolution Live Cell Raman Imaging Using Subcellular Organelle-Targeting SERS-Sensitive Gold Nanoparticles with Highly Narrow Intra-Nanogap
We report a method to achieve high speed and high resolution live cell Raman images using small spherical gold nanoparticles with highly narrow intra-nanogap structures responding to NIR excitation (785 nm) and high-speed confocal Raman microscopy. The three different Raman-active molecules placed in the narrow intra-nanogap showed a strong and uniform Raman intensity in solution even under transient exposure time (10 ms) and low input power of incident laser (200 μW), which lead to obtain high-resolution single cell image within 30 s without inducing significant cell damage. The high resolution Raman image showed the distributions of gold nanoparticles for their targeted sites such as cytoplasm, mitochondria, or nucleus. The high speed Raman-based live cell imaging allowed us to monitor rapidly changing cell morphologies during cell death induced by the addition of highly toxic KCN solution to cells. These results strongly suggest that the use of SERS-active nanoparticle can greatly improve the current temporal resolution and image quality of Raman-based cell images enough to obtain the detailed cell dynamics and/or the responses of cells to potential drug molecules.
- 11 September 2014
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 50 (88) , 13481-13484
Plasmon-assisted and visible-light induced graphene oxide reduction and efficient fluorescence quenching
The use of plasmonic nanoparticles accelerated visible-light induced reduction of graphene oxide at room temperature.
- 11 September 2014
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 50 (88) , 13481-13484
Plasmon-assisted and visible-light induced graphene oxide reduction and efficient fluorescence quenching
The use of plasmonic nanoparticles accelerated visible-light induced reduction of graphene oxide at room temperature.