BSBo Stenberg

Bo Stenberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bo Stenberg has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • A.H. Jean Robertson

    The James Hutton Institute, Craigiebuckler, Aberdeen AB15 8QH, Scotland, UK

    1 shared publication
  • Angel Faz Cano

    Technical University of Cartagena, Department of Agricultural Production, Paseo Alfonso XIII, 48. 30203 Cartagena, Spain

    1 shared publication
  • Fatemah Khayamim

    Isfahan University of Technology, Department of Soil Science, Isfahan 84156-83111, Islamic Republic of Iran

    1 shared publication
  • Hossein Khademi

    Isfahan University of Technology, Department of Soil Science, Isfahan 84156-83111, Islamic Republic of Iran

    1 shared publication
  • J. Wetterlind

    Department of Soil and Environment Swedish University of Agricultural Sciences Gråbrödragatan 19, PO box 234 532 23 Skara Sweden

    1 shared publication
  • Johanna Wetterlind

    Department of Soil and Environment Swedish University of Agricultural Sciences Skara Sweden

    1 shared publication

Latest Publications

  • Open Access

    Using Visible and near Infrared Spectroscopy to Estimate Carbonates and Gypsum in Soils in Arid and Subhumid Regions of Isfahan, Iran

    by Fatemah Khayamim, Johanna Wetterlind, Hossein Khademi, A.H. Jean Robertson, Angel Faz Cano, Bo Stenberg

    Soils in arid and semi-arid regions are strongly affected by the accumulation of carbonates, gypsum and other, more soluble, salts. Carbonates and gypsum both have a considerable influence on soil properties, especially the chemical properties of the soil solution. The development of reliable, fast and inexpensive methods to quantify the amounts of carbonates and gypsum in soil is therefore important. Visible and near infrared (vis-NIR) spectroscopy is a non-destructive, rapid and cheap method for measuring several soil properties simultaneously. However, research on vis-NIR spectroscopy in quantifying carbonates and gypsum is limited. Therefore, this study evaluated the efficiency of vis-NIR spectroscopy in quantifying carbonates and gypsum in surface soils using partial least-squares regression (PLSR) compared with standard laboratory methods and compared PLSR with a feature-specific method using continuum removal (CR). Carbonates and gypsum in a total of 251 sieved and air-dried topsoil samples from Isfahan Province in central Iran were measured by standard laboratory methods and vis-NIR spectroscopy (350–2500 nm wavelength range). In parallel, PLSR and the feature- specific method based on CR spectra were used to predict carbonates and gypsum. The PLSR model efficiency ( E) for carbonates and gypsum in the validation set was 0.52 and 0.80, respectively. The PLSR model resulted in better predictions than the feature-specific method for both soil properties. Because of the unique absorption features of gypsum, which did not overlap with other soil properties, predictions of gypsum resulted in higher E values and lower errors than predictions of carbonates.


  • Improving the prediction performance of a large tropical vis‐ NIR spectroscopic soil library from B razil by clustering into smaller subsets or use of data mining calibration techniques

    by S. R. Araújo, J. Wetterlind, J. A. M. Demattê, B. Stenberg

    Summary: Effective agricultural planning requires basic soil information. In recent decades visible near‐infrared diffuse reflectance spectroscopy (vis‐ NIR ) has been shown to be a viable alternative for rapidly analysing soil properties. We studied 7172 samples of seven different soil types collected from several regions of B razil and varying in organic matter ( OM ) (0.2–10.3%) and clay content (0.2–99.0%). The aim was to explore the possibility of enhancing the performance of vis‐ NIR data in predicting organic matter and clay content in this library by dividing it into smaller sub‐libraries on the basis of their vis‐ NIR spectra. We used partial least square regression ( PLSR ) models on the sub‐libraries and compared the results with PLSR and two non‐linear calibration techniques, boosted regression trees ( BT ) and support vector machines ( SVM ) applied to the whole library. The whole library calibrations for clay performed well ( ME (modelling efficiency) > 0.82; RMSE (root mean squared error) < 10.9%), reflecting the influence of the direct spectral responses of this property in the vis‐ NIR range. Calibrations for OM were reasonably good, especially in view of the very small variation in this property ( ME > 0.60; RMSE < 0.55%). The best results were, however, found when dividing the large library into smaller subsets by using variation in the mean‐normalized or first derivative spectra. This divided the global data set into clusters that were more uniform in mineralogy, regardless of geographical origin, and improved predictive performance. The best clustering method improved the RMSE in the validation to 8.6% clay and 0.47% OM , which corresponds to a 21% and 15% reduction, respectively, as compared with whole library PLSR . For the whole library, SVM performed almost equally well, reducing RMSE to 8.9% clay and 0.48% OM .


  • On-line measurement of animal and bio slurry quality variations with near infrared spectroscopy

    by B. Stenberg, K. Gustafsson

    There is a very large variation in dry matter and content of various plant nutrients in animal slurry and digestate from biogas production. For more precise fertilization application, quantification and monitoring of available plant nutrients prior to spreading at the farm would be advantageous. Near infrared reflectance (NIR) spectroscopy is suitable for on-line analyses and is a potential technology for such monitoring. In this study, 73 dairy, pig and bio slurries were analyzed in a test rig simulating a real spreader. Calibrations were made with partial least squared (PLS) regression. Calibrations worked best for dry matter content and, in general, calibrations for dairy slurry worked better than those for pig and bio slurries. In addition, 13 real bio slurry loads were analyzed during spreading. Spectral variation between loads was slightly larger than within loads. Compared to the variation between bio slurry plants, the variation between loads was very small.