Jo Erling Riise Waage
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jo Erling Riise Waage has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Sabine Leh
Department of Pathology, Haukeland University Hospital, Bergen, Norway
3 shared publications F. Pfeffer
Department of Clinical Medicine, University of Bergen, Norway
2 shared publications- Gunnar Baatrup
Department of Clinical Research, University of Southern Denmark, 5230 Odense, Denmark
2 shared publications R. F. Havre
Department of Clinical Medicine, University of Bergen, Norway
2 shared publications- Simon Parkinson Bach
Robotics and Digital Surgery Initiative, Royal College of Surgeons of England, London, England
2 shared publications - Anesa Mulabecirovic
National Centre for Ultrasound in Gastroenterology Department of Medicine Haukeland University Hospital Bergen Norway
1 shared publication
Latest Publications
- Open Access
- 16 April 2018
- Published by MDPI AG in Preprints.org
Strain Ratio as a Quantification Tool in Strain Imaging
1) Background: Ultrasound-based strain imaging is now available in several ultrasound (US) scanners. Strain ratio (SR) can be used to quantify strain recorded simultaneously in two different user-selected areas, ideally exposed to the same amount of stress. The aim of this study was to evaluate SR variability when assessed in an in-vitro setup with a tissue-mimicking phantom, on resected tissue samples and in live tissue scanning with endoscopic applications. 2) Material and methods: Retrospective analysis of SR for quantification of elastic contrasts in a tissue-mimicking phantom containing four homogenous inclusions, in 38 resected bowel wall lesions and in 48 focal pancreatic lesions examined in vivo. Median SR and the inter-quartile range (IQR) was calculated on all external and endoscopic US-applications. The IQR/median provides a measure of the SR variability focusing on the two percentiles of the data closest to the median value. 3) Results: The overall variability of SR was lowest in a tissue-mimicking phantom (mean QR/median SR: 0.07). In resected bowel wall lesions representing adenomas, adenocarcinomas or Crohn lesions, the variability increased (mean IQR/Median: 0.62). During an endoscopic examination of focal pancreatic lesions in vivo, the variability increased further (mean IQR/Median: 2.04). 4) Conclusion: SR variability increased when assessed on different targets with growing heterogeneity and biological variability as one moved from homogeneous media to live tissues and endoscopic application. This may indicate a limitation for the accuracy SR evaluation in clinical applications.
- 16 April 2018
- Published by MDPI AG in Preprints.org
Open AccessStrain Ratio as a Quantification Tool in Strain Imaging
1) Background: Ultrasound-based strain imaging is now available in several ultrasound (US) scanners. Strain ratio (SR) can be used to quantify strain recorded simultaneously in two different user-selected areas, ideally exposed to the same amount of stress. The aim of this study was to evaluate SR variability when assessed in an in-vitro setup with a tissue-mimicking phantom, on resected tissue samples and in live tissue scanning with endoscopic applications. 2) Material and methods: Retrospective analysis of SR for quantification of elastic contrasts in a tissue-mimicking phantom containing four homogenous inclusions, in 38 resected bowel wall lesions and in 48 focal pancreatic lesions examined in vivo. Median SR and the inter-quartile range (IQR) was calculated on all external and endoscopic US-applications. The IQR/median provides a measure of the SR variability focusing on the two percentiles of the data closest to the median value. 3) Results: The overall variability of SR was lowest in a tissue-mimicking phantom (mean QR/median SR: 0.07). In resected bowel wall lesions representing adenomas, adenocarcinomas or Crohn lesions, the variability increased (mean IQR/Median: 0.62). During an endoscopic examination of focal pancreatic lesions in vivo, the variability increased further (mean IQR/Median: 2.04). 4) Conclusion: SR variability increased when assessed on different targets with growing heterogeneity and biological variability as one moved from homogeneous media to live tissues and endoscopic application. This may indicate a limitation for the accuracy SR evaluation in clinical applications.
- 15 April 2015
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 36 (06) , 611-617
Strain Elastography Evaluation of Rectal Tumors: Inter- and Intraobserver Reproducibility
Purpose: Elastography is a promising method for the identification and differentiation of malignant tissue in several organ systems. The primary aim was to evaluate the inter- and intraobserver reproducibility of endorectal strain elastography differentiation of adenomas and adenocarcinomas. The secondary aim was to compare the performance of strain elastography to endorectal ultrasonography (ERUS) examinations. Materials and Methods: Consecutive inclusion of 95 ERUS examinations and 110 elastography video loops with ERUS overlay mode. Video loops were randomized and evaluated by eight observers on two separate occasions. Observers were blinded to all clinical information except the circumferential location of the tumor. A continuous visual analog scale (VAS) and a categorical scale (W-score) were used for elastography evaluation. ERUS loops were T-staged according to the TNM classification system. Histopathological evaluation of surgical resection specimen was used as the reference standard. Results: Strain elastography visual evaluation yielded intraobserver variability from 0.86 to 0.97 and interobserver variability of 0.99. VAS strain elastography differentiation of adenomas (pT0) and adenocarcinomas (pT1 – 4) yielded sensitivity, specificity, accuracy, positive and negative predictive values of 0.94, 0.71, 0.89, 0.92 and 0.78, respectively. The corresponding ERUS values were 0.83, 0.64, 0.79, 0.88 and 0.54, respectively. Conclusion: Visual evaluation of elastography loops is highly reproducible in an offline setting with blinded observers, and correlates significantly with pT-stages. Strain elastography performs better than ERUS and might consequently improve staging. Ziel: Die Identifikation und Differenzierung von bösartigen Tumoren in verschiedenen Organen mit Elastografie/Gewebeelastizität hat vielversprechende Ergebnisse gezeigt. Primäres Ziel dieser Studie war die Evaluation der Inter- und Intra-Beobachter Variabilität der Differenzierung von Adenomen und Adenokarzinomen mittels endorektaler Elastografie. Zusätzlich wurden die Ergebnisse von Elastografie und endorektalem Ultraschall (ERUS) verglichen. Material und Methoden: 95 gespeicherte ERUS- und 110 Elastografie-Videos wurden eingeschlossen. Die Videoclips wurden randomisiert und von 8 Untersuchern zu 2 verschiedenen Zeitpunkten ausgewertet. Bis auf die zirkumferentielle Lage des Tumors waren alle klinischen Informationen für die Untersucher geblindet. Eine kontinuierliche visuelle Analogskala (VAS) und eine kategorische Skala (W-Skala) wurden zur Beurteilung der Elastografie verwendet. ERUS- Schnitte wurden entsprechend der TNM- Klassifikation in T-Stadien eingeteilt. Die Histologie der Operationspräparate diente als Referenz. Ergebnisse: Die visuelle Evaluierung der Gewebeelastizität ergab eine Intra- Beobachter Variabilität von 0,86 bis 0,97 und eine Inter-Beobachter Variabilität von 0,99. Die Differenzierung von Adenomen (pT0) und Adenokarzinomen (pT1 – 4) mittels VAS Gewebeelastizität ergab eine Sensitivität, Spezifität, Genauigkeit, positiver-, negativer- Vorhersagewert von 0,94, 0,71, 0,89, 0,92 und 0.78. Die entsprechenden Resultate für ERUS waren: 0,83, 0,64, 0,79, 0,88 und 0,54. Schlussfolgerung: Die Bestimmung der Gewebeelastizität mittels VAS- und W- Skala ist eine sehr exakte und zuverlässige Methode zur Differenzierung von Adenomen und Adenokarzinomen des Rektum. Die Analyse der Videoclips ergibt eine höhere Genauigkeit und Reproduzierbarkeit der Elastografie verglichen mit ERUS-Untersuchungen.
- 15 April 2015
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 36 (06) , 611-617
Strain Elastography Evaluation of Rectal Tumors: Inter- and Intraobserver Reproducibility
Purpose: Elastography is a promising method for the identification and differentiation of malignant tissue in several organ systems. The primary aim was to evaluate the inter- and intraobserver reproducibility of endorectal strain elastography differentiation of adenomas and adenocarcinomas. The secondary aim was to compare the performance of strain elastography to endorectal ultrasonography (ERUS) examinations. Materials and Methods: Consecutive inclusion of 95 ERUS examinations and 110 elastography video loops with ERUS overlay mode. Video loops were randomized and evaluated by eight observers on two separate occasions. Observers were blinded to all clinical information except the circumferential location of the tumor. A continuous visual analog scale (VAS) and a categorical scale (W-score) were used for elastography evaluation. ERUS loops were T-staged according to the TNM classification system. Histopathological evaluation of surgical resection specimen was used as the reference standard. Results: Strain elastography visual evaluation yielded intraobserver variability from 0.86 to 0.97 and interobserver variability of 0.99. VAS strain elastography differentiation of adenomas (pT0) and adenocarcinomas (pT1 – 4) yielded sensitivity, specificity, accuracy, positive and negative predictive values of 0.94, 0.71, 0.89, 0.92 and 0.78, respectively. The corresponding ERUS values were 0.83, 0.64, 0.79, 0.88 and 0.54, respectively. Conclusion: Visual evaluation of elastography loops is highly reproducible in an offline setting with blinded observers, and correlates significantly with pT-stages. Strain elastography performs better than ERUS and might consequently improve staging. Ziel: Die Identifikation und Differenzierung von bösartigen Tumoren in verschiedenen Organen mit Elastografie/Gewebeelastizität hat vielversprechende Ergebnisse gezeigt. Primäres Ziel dieser Studie war die Evaluation der Inter- und Intra-Beobachter Variabilität der Differenzierung von Adenomen und Adenokarzinomen mittels endorektaler Elastografie. Zusätzlich wurden die Ergebnisse von Elastografie und endorektalem Ultraschall (ERUS) verglichen. Material und Methoden: 95 gespeicherte ERUS- und 110 Elastografie-Videos wurden eingeschlossen. Die Videoclips wurden randomisiert und von 8 Untersuchern zu 2 verschiedenen Zeitpunkten ausgewertet. Bis auf die zirkumferentielle Lage des Tumors waren alle klinischen Informationen für die Untersucher geblindet. Eine kontinuierliche visuelle Analogskala (VAS) und eine kategorische Skala (W-Skala) wurden zur Beurteilung der Elastografie verwendet. ERUS- Schnitte wurden entsprechend der TNM- Klassifikation in T-Stadien eingeteilt. Die Histologie der Operationspräparate diente als Referenz. Ergebnisse: Die visuelle Evaluierung der Gewebeelastizität ergab eine Intra- Beobachter Variabilität von 0,86 bis 0,97 und eine Inter-Beobachter Variabilität von 0,99. Die Differenzierung von Adenomen (pT0) und Adenokarzinomen (pT1 – 4) mittels VAS Gewebeelastizität ergab eine Sensitivität, Spezifität, Genauigkeit, positiver-, negativer- Vorhersagewert von 0,94, 0,71, 0,89, 0,92 und 0.78. Die entsprechenden Resultate für ERUS waren: 0,83, 0,64, 0,79, 0,88 und 0,54. Schlussfolgerung: Die Bestimmung der Gewebeelastizität mittels VAS- und W- Skala ist eine sehr exakte und zuverlässige Methode zur Differenzierung von Adenomen und Adenokarzinomen des Rektum. Die Analyse der Videoclips ergibt eine höhere Genauigkeit und Reproduzierbarkeit der Elastografie verglichen mit ERUS-Untersuchungen.
- Open Access
- 21 January 2015
- Published by Wiley in Colorectal Disease
- Vol. 17 (2) , 124-131
Endorectal ultrasonography, strain elastography and MRI differentiation of rectal adenomas and adenocarcinomas
Strain elastography is a method for recording tissue hardness. Strain in different areas may be compared using strain ratio (SR). The aims of this study were to validate a previously proposed SR cut-off value of 1.25 for differentiating adenocarcinomas from adenomas and to compare the performance of endorectal ultrasonography (ERUS), strain elastography and MRI in the same patients. A prospective evaluation of 120 consecutive patients with rectal neoplasia, using a predetermined elastography strain ratio cut-off value, was performed to differentiate adenomas from adenocarcinomas. ERUS and MRI were performed according to standard routine at Haukeland University Hospital, defining T0 as adenomas and T1-T4 as adenocarcinomas. Subsequent histopathology was used as the reference standard. Histopathological evaluation revealed 21 adenomas and 99 adenocarcinomas. Sensitivity, specificity and accuracy (with 95% CI) were as follows: ERUS: 0.96 (0.90-0.99), 0.62 (0.40-0.80) and 0.90 (0.83-0.94); elastography SR: 0.96 (0.90-0.99), 0.86 (0.66-0.96) and 0.94 (0.88-0.97); and MRI: 0.99 (0.94-1.00), 0.07 (0.00-0.31) and 0.87 (0.80-0.93). This study confirms that the elastography SR assessment accurately differentiates sessile adenomas from adenocarcinomas. SR assessment has a superior ability to differentiate adenomas and adenocarcinomas when compared with ERUS and MRI. MRI examination seems unable to recognize adenomas and should be interpreted with care when early-stage rectal neoplasia is suspected.
- 21 January 2015
- Published by Wiley in Colorectal Disease
- Vol. 17 (2) , 124-131
Open AccessEndorectal ultrasonography, strain elastography and MRI differentiation of rectal adenomas and adenocarcinomas
Strain elastography is a method for recording tissue hardness. Strain in different areas may be compared using strain ratio (SR). The aims of this study were to validate a previously proposed SR cut-off value of 1.25 for differentiating adenocarcinomas from adenomas and to compare the performance of endorectal ultrasonography (ERUS), strain elastography and MRI in the same patients. A prospective evaluation of 120 consecutive patients with rectal neoplasia, using a predetermined elastography strain ratio cut-off value, was performed to differentiate adenomas from adenocarcinomas. ERUS and MRI were performed according to standard routine at Haukeland University Hospital, defining T0 as adenomas and T1-T4 as adenocarcinomas. Subsequent histopathology was used as the reference standard. Histopathological evaluation revealed 21 adenomas and 99 adenocarcinomas. Sensitivity, specificity and accuracy (with 95% CI) were as follows: ERUS: 0.96 (0.90-0.99), 0.62 (0.40-0.80) and 0.90 (0.83-0.94); elastography SR: 0.96 (0.90-0.99), 0.86 (0.66-0.96) and 0.94 (0.88-0.97); and MRI: 0.99 (0.94-1.00), 0.07 (0.00-0.31) and 0.87 (0.80-0.93). This study confirms that the elastography SR assessment accurately differentiates sessile adenomas from adenocarcinomas. SR assessment has a superior ability to differentiate adenomas and adenocarcinomas when compared with ERUS and MRI. MRI examination seems unable to recognize adenomas and should be interpreted with care when early-stage rectal neoplasia is suspected.
- Open Access
- 1 September 2014
- Published by Wiley in Colorectal Disease
- Vol. 17 (1) , 50-56
Combined endorectal ultrasonography and strain elastography for the staging of early rectal cancer
Aim: Strain elastography is a novel approach to rectal tumour evaluation. The primary aim of this study was to correlate elastography to pT stages of rectal tumours and to assess the ability of the method to differentiate rectal adenomas (pT0) from early rectal cancer (pT1–2). Secondary aims were to compare elastography with endorectal ultrasonography (ERUS) and to propose a combined strain elastography and ERUS staging algorithm.Method: In all, 120 consecutive patients with a suspected rectal tumour were examined in this staging study. Patients receiving surgery without neoadjuvant radiotherapy were included (n = 59). All patients were examined with ERUS and elastography. Treatment decisions were made by multidisciplinary team (MDT) assessment, without considering the strain elastography examination.Results: Histopathology identified 21 adenomas, 13 pT1, 9 pT2, 15 pT3 and one pT4. Mean elastography strain ratios were predictive of T stage (P = 0.01). Differentiation of adenomas from early rectal cancer (pT1–2) had sensitivity, specificity and accuracy of 0.82, 0.86 and 0.84 for elastography and 0.82, 0.62 and 0.72 for ERUS. A combined staging algorithm was developed to identify tumours eligible for local resection. Based on MDT evaluation 32% of tumours later identified as pT0 or pT1 were treated with total mesorectal excision, even though a local excision might have sufficed. Combined ERUS and elastography evaluation would have significantly reduced this number to 9% (P = 0.008).Conclusion: Elastography may improve the staging of adenomas and early rectal cancer compared with ERUS alone. Combined ERUS and elastography assessment is likely to further improve the selection of patients for local resection.
- 1 September 2014
- Published by Wiley in Colorectal Disease
- Vol. 17 (1) , 50-56
Open AccessCombined endorectal ultrasonography and strain elastography for the staging of early rectal cancer
Aim: Strain elastography is a novel approach to rectal tumour evaluation. The primary aim of this study was to correlate elastography to pT stages of rectal tumours and to assess the ability of the method to differentiate rectal adenomas (pT0) from early rectal cancer (pT1–2). Secondary aims were to compare elastography with endorectal ultrasonography (ERUS) and to propose a combined strain elastography and ERUS staging algorithm.Method: In all, 120 consecutive patients with a suspected rectal tumour were examined in this staging study. Patients receiving surgery without neoadjuvant radiotherapy were included (n = 59). All patients were examined with ERUS and elastography. Treatment decisions were made by multidisciplinary team (MDT) assessment, without considering the strain elastography examination.Results: Histopathology identified 21 adenomas, 13 pT1, 9 pT2, 15 pT3 and one pT4. Mean elastography strain ratios were predictive of T stage (P = 0.01). Differentiation of adenomas from early rectal cancer (pT1–2) had sensitivity, specificity and accuracy of 0.82, 0.86 and 0.84 for elastography and 0.82, 0.62 and 0.72 for ERUS. A combined staging algorithm was developed to identify tumours eligible for local resection. Based on MDT evaluation 32% of tumours later identified as pT0 or pT1 were treated with total mesorectal excision, even though a local excision might have sufficed. Combined ERUS and elastography evaluation would have significantly reduced this number to 9% (P = 0.008).Conclusion: Elastography may improve the staging of adenomas and early rectal cancer compared with ERUS alone. Combined ERUS and elastography assessment is likely to further improve the selection of patients for local resection.
- 25 June 2014
- Published by Springer Nature
- p. 195-206
Endorectal Ultrasonography of Rectal Tumours