Julian Westphal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Julian Westphal has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
- Paul Christian Schulze
University Hospital Jena, Friedrich-Schiller-University, Germany (P.C.S.).
13 shared publications - Sven Möbius-Winkler
Department of Internal Medicine I, Cardiology, University Hospital Jena, Am Klinikum 1, 07747 Jena, Germany
9 shared publications - Franz Haertel
Department of Internal Medicine I, Division of Cardiology, Angiology and Intensive Medical Care, Friedrich-Schiller-University, University Hospital Jena , Jena
6 shared publications - Jurgen Bogoviku
Department of Internal Medicine I, Cardiology, University Hospital Jena, Am Klinikum 1, 07747 Jena, Germany
5 shared publications - Marcus Franz
Department of Internal Medicine I, University Hospital Jena, Jena, Germany
5 shared publications - Tarek Bekfani
Department of Internal Medicine, Division of Cardiology and Angiology, University Hospital Magdeburg, 39120 Magdeburg, Germany
4 shared publications
Latest Publications
- Open Access
- 24 February 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (5) , 1292
The Jena Method: Perfusionist Independent, Standby Wet-Primed Extracorporeal Membrane Oxygenation (ECMO) Circuit for Immediate Catheterization Laboratory and/or Hybrid Operating Room Deployment
Background: The timely initiation of extracorporeal membrane oxygenation (ECMO) is crucial for providing life support. However, delays can occur when perfusionists are not readily available. The Jena Method aims to address this issue by offering a wet-primed ECMO system that can be rapidly established without the perfusionist’s presence. Methods: The goal was to ensure prompt ECMO initiation while maintaining patient safety. The method focuses on meeting hygienic standards, safe primed storage of the circuit, staff training, and providing clear step-by-step instructions for the ECMO unit. Results: Since implementing the Jena Method in 2015, 306 patients received VA-ECMO treatment. Bacterial tests confirmed the sterility of the primed ECMO circuits during a 14-day period. The functionality of all the components of the primed ECMO circuit after 14 days, especially the pump and oxygenator, were thoroughly checked and no malfunction was found to this day. To train staff for independent ECMO initiation, a step-by-step system involves safely bringing the ECMO unit to the intervention site and establishing all connections. This includes powering up, managing recirculation, de-airing the system, and preparing it for cannula connection. A self-developed picture-based guide assists in this process. New staff members learn from colleagues and receive quarterly training sessions by perfusionists. After ECMO deployment, the perfusionist provides a new primed system for a potential next patient. Conclusions: Establishing a permanently wet-primed on-demand extracorporeal life support circuit without direct perfusionist support is feasible and safe. The Jena Method enables rapid ECMO deployment and has the potential to be adopted in emergency departments as well.
- 24 February 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (5) , 1292
Open AccessThe Jena Method: Perfusionist Independent, Standby Wet-Primed Extracorporeal Membrane Oxygenation (ECMO) Circuit for Immediate Catheterization Laboratory and/or Hybrid Operating Room Deployment
Background: The timely initiation of extracorporeal membrane oxygenation (ECMO) is crucial for providing life support. However, delays can occur when perfusionists are not readily available. The Jena Method aims to address this issue by offering a wet-primed ECMO system that can be rapidly established without the perfusionist’s presence. Methods: The goal was to ensure prompt ECMO initiation while maintaining patient safety. The method focuses on meeting hygienic standards, safe primed storage of the circuit, staff training, and providing clear step-by-step instructions for the ECMO unit. Results: Since implementing the Jena Method in 2015, 306 patients received VA-ECMO treatment. Bacterial tests confirmed the sterility of the primed ECMO circuits during a 14-day period. The functionality of all the components of the primed ECMO circuit after 14 days, especially the pump and oxygenator, were thoroughly checked and no malfunction was found to this day. To train staff for independent ECMO initiation, a step-by-step system involves safely bringing the ECMO unit to the intervention site and establishing all connections. This includes powering up, managing recirculation, de-airing the system, and preparing it for cannula connection. A self-developed picture-based guide assists in this process. New staff members learn from colleagues and receive quarterly training sessions by perfusionists. After ECMO deployment, the perfusionist provides a new primed system for a potential next patient. Conclusions: Establishing a permanently wet-primed on-demand extracorporeal life support circuit without direct perfusionist support is feasible and safe. The Jena Method enables rapid ECMO deployment and has the potential to be adopted in emergency departments as well.
- Open Access
- 1 January 2024
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 17 (1) , e010813
Metabolic Profiling Identifies 1-MetHis and 3-IPA as Potential Diagnostic Biomarkers for Patients With Acute and Chronic Heart Failure With Reduced Ejection Fraction
BACKGROUND: Metabolomics has become a valuable tool for identifying potential new biomarkers and metabolic profiles. It has the potential to improve the diagnosis and prognosis of different phenotypes of heart failure. To generate a distinctive metabolic profile, we assessed and compared the metabolic phenotypes of patients with acute decompensated heart failure (ADHF), patients with chronic heart failure (CHF), and healthy controls. METHODS: Plasma metabolites were analyzed by liquid-chromatography mass spectrometry/mass spectrometry and the MxP Quant 500 kit in 15 patients with ADHF, 50 patients with CHF (25 with dilated cardiomyopathy, 25 with ischemic cardiomyopathy), and 13 controls. RESULTS: Of all metabolites identified to be significantly altered, 3-indolepropionic acid and 1-methyl histidine showed the highest concentration differences in ADHF and CHF compared with control. Area under the curve–receiver operating characteristic analysis showed an area under the curve ≥0.8 for 3-indolepropionic acid and 1-methyl histidine, displaying good discrimination capabilities between control and patient cohorts. Additionally, symmetrical dimethylarginine (mean, 1.97±0.61 [SD]; P =0.01) was identified as a suitable biomarker candidate for ADHF and kynurenine (mean, 1.69±0.39 [SD]; P =0.009) for CHF when compared with control, both demonstrating an area under the curve ≥0.85. CONCLUSIONS: Our study provides novel insights into the metabolic differences between ADHF and CHF and healthy controls. We here identify new metabolites for potential diagnostic and prognostic purposes.
- 1 January 2024
- Published by Wolters Kluwer Health in Circulation: Heart Failure
- Vol. 17 (1) , e010813
Open AccessMetabolic Profiling Identifies 1-MetHis and 3-IPA as Potential Diagnostic Biomarkers for Patients With Acute and Chronic Heart Failure With Reduced Ejection Fraction
BACKGROUND: Metabolomics has become a valuable tool for identifying potential new biomarkers and metabolic profiles. It has the potential to improve the diagnosis and prognosis of different phenotypes of heart failure. To generate a distinctive metabolic profile, we assessed and compared the metabolic phenotypes of patients with acute decompensated heart failure (ADHF), patients with chronic heart failure (CHF), and healthy controls. METHODS: Plasma metabolites were analyzed by liquid-chromatography mass spectrometry/mass spectrometry and the MxP Quant 500 kit in 15 patients with ADHF, 50 patients with CHF (25 with dilated cardiomyopathy, 25 with ischemic cardiomyopathy), and 13 controls. RESULTS: Of all metabolites identified to be significantly altered, 3-indolepropionic acid and 1-methyl histidine showed the highest concentration differences in ADHF and CHF compared with control. Area under the curve–receiver operating characteristic analysis showed an area under the curve ≥0.8 for 3-indolepropionic acid and 1-methyl histidine, displaying good discrimination capabilities between control and patient cohorts. Additionally, symmetrical dimethylarginine (mean, 1.97±0.61 [SD]; P =0.01) was identified as a suitable biomarker candidate for ADHF and kynurenine (mean, 1.69±0.39 [SD]; P =0.009) for CHF when compared with control, both demonstrating an area under the curve ≥0.85. CONCLUSIONS: Our study provides novel insights into the metabolic differences between ADHF and CHF and healthy controls. We here identify new metabolites for potential diagnostic and prognostic purposes.
- 29 December 2023
- Published by Springer Nature
- p. 323-339
Akute Herzinsuffizienz und kardiale Dekompensation
- 29 December 2023
- Published by Springer Nature
- p. 323-339
Akute Herzinsuffizienz und kardiale Dekompensation
- Open Access
- 27 November 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (23) , 16802
Prognostic Value of Galectin-3 after Left Atrial Appendage Occlusion for Predicting Peri-Device Leakage
Echocardiographic detection of residual peri-device leakage (PDL) after percutaneous left atrial appendage occlusion (LAAO) is crucial for managing anticoagulation. Galectin-3, a protein involved in tissue–foreign body interactions, may hold significance in understanding PDL and cardiac tissue remodeling after LAAO. This study aimed to analyze galectin-3 serum levels in relation to PDL using a novel echo-morphological classification. LAAO eligible patients were included in the study. Galectin-3 serum levels were measured before LAAO, at 45 days (45D), and at 6 months (6M) after the procedure. Transesophageal echocardiography was used to assess LAAO success. A new echo-morphological classification categorized the degree of LAAO into three different types (A: homogenous echodensity, indicating completely thrombosed device; B: inhomogeneous echolucencies ( 50%). Among 47 patients, complete LAAO was achieved in 60% after 45D and in 74% after 6M. We observed a significant increase and distribution of serum levels of galectin-3 [ng/mL] after 45D among the three types (baseline: 13.1 ± 5.8 ng/mL; 45D: 16.3 ± 7.2 ng/mL (Type A) vs. 19.2 ± 8.6 ng/mL (Type B) vs. 25.8 ± 9.4 ng/mL (Type C); p = 0.031), followed by a drop in galectin-3 for Types A and B after 6M toward and below the baseline levels (6M: 8.9 ± 3.1 ng/mL (Type A) vs. 12.4 ± 5.5 ng/mL (Type B)), whereas Type C persisted in showing elevated galectin-3 levels compared to all other types (6M: 17.5 ± 4.5 ng/mL (Type C); p < 0.01). Increased galectin-3 serum levels after LAAO likely reflect the transition from thrombus formation to fibrotic scar development in the LAA lumen. Successful occlusion is associated with a time-restricted decrease in galectin-3 levels after 6 months, while relevant PDL leads to persistently elevated levels, making galectin-3 a potential predictor of occlusion success.
- 27 November 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (23) , 16802
Open AccessPrognostic Value of Galectin-3 after Left Atrial Appendage Occlusion for Predicting Peri-Device Leakage
Echocardiographic detection of residual peri-device leakage (PDL) after percutaneous left atrial appendage occlusion (LAAO) is crucial for managing anticoagulation. Galectin-3, a protein involved in tissue–foreign body interactions, may hold significance in understanding PDL and cardiac tissue remodeling after LAAO. This study aimed to analyze galectin-3 serum levels in relation to PDL using a novel echo-morphological classification. LAAO eligible patients were included in the study. Galectin-3 serum levels were measured before LAAO, at 45 days (45D), and at 6 months (6M) after the procedure. Transesophageal echocardiography was used to assess LAAO success. A new echo-morphological classification categorized the degree of LAAO into three different types (A: homogenous echodensity, indicating completely thrombosed device; B: inhomogeneous echolucencies ( 50%). Among 47 patients, complete LAAO was achieved in 60% after 45D and in 74% after 6M. We observed a significant increase and distribution of serum levels of galectin-3 [ng/mL] after 45D among the three types (baseline: 13.1 ± 5.8 ng/mL; 45D: 16.3 ± 7.2 ng/mL (Type A) vs. 19.2 ± 8.6 ng/mL (Type B) vs. 25.8 ± 9.4 ng/mL (Type C); p = 0.031), followed by a drop in galectin-3 for Types A and B after 6M toward and below the baseline levels (6M: 8.9 ± 3.1 ng/mL (Type A) vs. 12.4 ± 5.5 ng/mL (Type B)), whereas Type C persisted in showing elevated galectin-3 levels compared to all other types (6M: 17.5 ± 4.5 ng/mL (Type C); p < 0.01). Increased galectin-3 serum levels after LAAO likely reflect the transition from thrombus formation to fibrotic scar development in the LAA lumen. Successful occlusion is associated with a time-restricted decrease in galectin-3 levels after 6 months, while relevant PDL leads to persistently elevated levels, making galectin-3 a potential predictor of occlusion success.
- Open Access
- 25 July 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (15) , 4893
Impact of a VA–ECMO in Combination with an Extracorporeal Cytokine Hemadsorption System in Critically Ill Patients with Cardiogenic Shock–Design and Rationale of the ECMOsorb Trial
Background: Cardiogenic shock and arrest present as critical, life-threatening emergencies characterized by severely compromised tissue perfusion and inadequate oxygen supply. Veno–arterial extracorporeal membrane oxygenation (VA–ECMO) serves as a mechanical support system for patients suffering shock refractory to conventional resuscitation. Despite the utilization of VA–ECMO, clinical deterioration due to systemic inflammatory response syndrome (SIRS) resulting from the underlying shock and exposure of blood cells to the artificial surfaces of the ECMO circuit may occur. To address this issue, cytokine adsorbers offer a valuable solution by eliminating blood proteins, thereby controlling SIRS and potentially improving hemodynamics. Consequently, a prospective, randomized, blinded clinical trial will be carried out with ECMOsorb. Methods and Study Design: ECMOsorb is a single-center, controlled, randomized, triple-blinded trial that will compare the hemodynamic effects of treatment with a VA–ECMO in combination with a cytokine adsorber (CytoSorb®, intervention) to treatment with VA–ECMO only (control) in patients with cardiogenic shock (with or without prior cardiopulmonary resuscitation (CPR)) requiring extracorporeal, hemodynamic support. Fifty-four patients will be randomized in a 1:1 fashion to the intervention or control group over a 36-month period. The primary endpoint of ECMOsorb is the improvement of the Inotropic Score (IS) 72 h after the intervention. Prognostic indicators, including mortality rates, hemodynamic parameters, laboratory findings, echocardiographic assessments, quality of life measurements, and clinical parameters, will serve as secondary outcome measures. The safety evaluation encompasses endpoints such as air embolisms, allergic reactions, peripheral ischemic complications, vascular complications, bleeding incidents, and stroke occurrences. Conclusions: The ECMOsorb trial seeks to assess the efficacy of a cytokine adsorber (CytoSorb®; CytoSorbents Europe GmbH, Berlin, Germany) in reducing SIRS and improving hemodynamics in patients with cardiogenic shock who are receiving VA–ECMO. We hypothesize that a reduction in cytokine levels can lead to faster weaning from inotropic and mechanical circulatory support, and ultimately to improved recovery.
- 25 July 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (15) , 4893
Open AccessImpact of a VA–ECMO in Combination with an Extracorporeal Cytokine Hemadsorption System in Critically Ill Patients with Cardiogenic Shock–Design and Rationale of the ECMOsorb Trial
Background: Cardiogenic shock and arrest present as critical, life-threatening emergencies characterized by severely compromised tissue perfusion and inadequate oxygen supply. Veno–arterial extracorporeal membrane oxygenation (VA–ECMO) serves as a mechanical support system for patients suffering shock refractory to conventional resuscitation. Despite the utilization of VA–ECMO, clinical deterioration due to systemic inflammatory response syndrome (SIRS) resulting from the underlying shock and exposure of blood cells to the artificial surfaces of the ECMO circuit may occur. To address this issue, cytokine adsorbers offer a valuable solution by eliminating blood proteins, thereby controlling SIRS and potentially improving hemodynamics. Consequently, a prospective, randomized, blinded clinical trial will be carried out with ECMOsorb. Methods and Study Design: ECMOsorb is a single-center, controlled, randomized, triple-blinded trial that will compare the hemodynamic effects of treatment with a VA–ECMO in combination with a cytokine adsorber (CytoSorb®, intervention) to treatment with VA–ECMO only (control) in patients with cardiogenic shock (with or without prior cardiopulmonary resuscitation (CPR)) requiring extracorporeal, hemodynamic support. Fifty-four patients will be randomized in a 1:1 fashion to the intervention or control group over a 36-month period. The primary endpoint of ECMOsorb is the improvement of the Inotropic Score (IS) 72 h after the intervention. Prognostic indicators, including mortality rates, hemodynamic parameters, laboratory findings, echocardiographic assessments, quality of life measurements, and clinical parameters, will serve as secondary outcome measures. The safety evaluation encompasses endpoints such as air embolisms, allergic reactions, peripheral ischemic complications, vascular complications, bleeding incidents, and stroke occurrences. Conclusions: The ECMOsorb trial seeks to assess the efficacy of a cytokine adsorber (CytoSorb®; CytoSorbents Europe GmbH, Berlin, Germany) in reducing SIRS and improving hemodynamics in patients with cardiogenic shock who are receiving VA–ECMO. We hypothesize that a reduction in cytokine levels can lead to faster weaning from inotropic and mechanical circulatory support, and ultimately to improved recovery.
- Open Access
- 8 August 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (15) , 4623
Rationale and Design of JenaMACS—Acute Hemodynamic Impact of Ventricular Unloading Using the Impella CP Assist Device in Patients with Cardiogenic Shock
Introduction: Cardiogenic shock due to myocardial infarction or heart failure entails a reduction in end organ perfusion. Patients who cannot be stabilized with inotropes and who experience increasing circulatory failure are in need of an extracorporeal mechanical support system. Today, small, percutaneously implantable cardiac assist devices are available and might be a solution to reduce mortality and complications. A temporary, ventricular, continuous flow propeller pump using magnetic levitation (Impella®) has been approved for that purpose. Methods and Study Design: JenaMACS (Jena Mechanical Assist Circulatory Support) is a monocenter, proof-of-concept study to determine whether treatment with an Impella CP® leads to improvement of hemodynamic parameters in patients with cardiogenic shock requiring extracorporeal, hemodynamic support. The primary outcomes of JenaMACS are changes in hemodynamic parameters measured by pulmonary artery catheterization and changes in echocardiographic parameters of left and right heart function before and after Impella® implantation at different support levels after 24 h of support. Secondary outcome measures are hemodynamic and echocardiographic changes over time as well as clinical endpoints such as mortality or time to hemodynamic stabilization. Further, laboratory and clinical safety endpoints including severe bleeding, stroke, neurological outcome, peripheral ischemic complications and occurrence of sepsis will be assessed. JenaMACS addresses essential questions of extracorporeal, mechanical, cardiac support with an Impella CP® device in patients with cardiogenic shock. Knowledge of the acute and subacute hemodynamic and echocardiographic effects may help to optimize therapy and improve the outcome in those patients. Conclusion: The JenaMACS study will address essential questions of extracorporeal, mechanical, cardiac support with an Impella CP® assist device in patients with cardiogenic shock. Knowledge of the acute and subacute hemodynamic and echocardiographic effects may help to optimize therapy and may improve outcome in those patients. Ethics and Dissemination: The protocol was approved by the institutional review board and ethics committee of the University Hospital of Jena. Written informed consent will be obtained from all participants of the study. The results of this study will be published in a renowned international medical journal, irrespective of the outcomes of the study. Strengths and Limitations: JenaMACS is an innovative approach to characterize the effect of additional left ventricular mechanical unloading during cardiogenic shock via a minimally invasive cardiac assist system (Impella CP®) 24 h after onset and will provide valuable data for acute interventional strategies or future prospective trials. However, JenaMACS, due to its proof-of-concept design, is limited by its single center protocol, with a small sample size and without a comparison group.
- 8 August 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (15) , 4623
Open AccessRationale and Design of JenaMACS—Acute Hemodynamic Impact of Ventricular Unloading Using the Impella CP Assist Device in Patients with Cardiogenic Shock
Introduction: Cardiogenic shock due to myocardial infarction or heart failure entails a reduction in end organ perfusion. Patients who cannot be stabilized with inotropes and who experience increasing circulatory failure are in need of an extracorporeal mechanical support system. Today, small, percutaneously implantable cardiac assist devices are available and might be a solution to reduce mortality and complications. A temporary, ventricular, continuous flow propeller pump using magnetic levitation (Impella®) has been approved for that purpose. Methods and Study Design: JenaMACS (Jena Mechanical Assist Circulatory Support) is a monocenter, proof-of-concept study to determine whether treatment with an Impella CP® leads to improvement of hemodynamic parameters in patients with cardiogenic shock requiring extracorporeal, hemodynamic support. The primary outcomes of JenaMACS are changes in hemodynamic parameters measured by pulmonary artery catheterization and changes in echocardiographic parameters of left and right heart function before and after Impella® implantation at different support levels after 24 h of support. Secondary outcome measures are hemodynamic and echocardiographic changes over time as well as clinical endpoints such as mortality or time to hemodynamic stabilization. Further, laboratory and clinical safety endpoints including severe bleeding, stroke, neurological outcome, peripheral ischemic complications and occurrence of sepsis will be assessed. JenaMACS addresses essential questions of extracorporeal, mechanical, cardiac support with an Impella CP® device in patients with cardiogenic shock. Knowledge of the acute and subacute hemodynamic and echocardiographic effects may help to optimize therapy and improve the outcome in those patients. Conclusion: The JenaMACS study will address essential questions of extracorporeal, mechanical, cardiac support with an Impella CP® assist device in patients with cardiogenic shock. Knowledge of the acute and subacute hemodynamic and echocardiographic effects may help to optimize therapy and may improve outcome in those patients. Ethics and Dissemination: The protocol was approved by the institutional review board and ethics committee of the University Hospital of Jena. Written informed consent will be obtained from all participants of the study. The results of this study will be published in a renowned international medical journal, irrespective of the outcomes of the study. Strengths and Limitations: JenaMACS is an innovative approach to characterize the effect of additional left ventricular mechanical unloading during cardiogenic shock via a minimally invasive cardiac assist system (Impella CP®) 24 h after onset and will provide valuable data for acute interventional strategies or future prospective trials. However, JenaMACS, due to its proof-of-concept design, is limited by its single center protocol, with a small sample size and without a comparison group.
- Top Cited Papers
- 26 July 2022
- Published by Wolters Kluwer Health in Circulation
- Vol. 146 (4) , 289-298
Effects of Early Empagliflozin Initiation on Diuresis and Kidney Function in Patients With Acute Decompensated Heart Failure (EMPAG-HF)
Background: Effective diuretic regimens using loop diuretics in patients with acute decompensated heart failure are often limited by the development of worsening kidney function. Sodium-glucose cotransporter-2 inhibitors induce glucosuria and sodium excretion with nephroprotective effects in patients with stable heart failure but their role in acute decompensated heart failure is unclear. Methods: In this single-center, prospective, double-blind, placebo-controlled, randomized study, we randomly assigned patients with acute decompensated heart failure to empagliflozin 25 mg daily or placebo in addition to standard decongestive treatments that included loop diuretics. The primary end point was cumulative urine output over 5 days. Secondary end points included diuretic efficiency, dynamics in markers of kidney function and injury, and NT-proBNP (N-terminal pro-B-type natriuretic peptide). Results: Sixty patients were randomized within 12 hours of hospitalization for acute decompensated heart failure. Addition of empagliflozin daily to standard medical treatment of acute decompensated heart failure resulted in a 25% increase in cumulative urine output over 5 days (median 10.8 versus 8.7 L mL in placebo, group difference estimation 2.2 L [95% CI, 8.4 to 3.6]; P =0.003). Empagliflozin increased diuretic efficiency compared with placebo (14.1 mL urine per milligram furosemide equivalent [95% CI, 0.6–27.7]; P =0.041) without affecting markers of renal function (estimated glomerular filtration rate, 51±19 versus 54±17 mL/min per 1.73 m²; P =0.599) or injury (total urinary protein, 492±845 versus 503±847 mg/g creatinine; P =0.975; and urinary α1-microglobulin, 55.4±38.6 versus 31.3±33.6 mg/g creatinine; P =0.066) with more pronounced decrease in NT-proBNP in the empagliflozin group compared with placebo (−1861 versus −727.2 pg/mL after 5 days; quotient in slope, 0.89 [95% CI, 0.83–0.95]; P <0.001). There were no differences in the incidence of safety events between groups. Conclusions: Early addition of empagliflozin to standard diuretic therapy increases urine output without affecting renal function in patients with acute decompensated heart failure. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04049045.
- 26 July 2022
- Published by Wolters Kluwer Health in Circulation
- Vol. 146 (4) , 289-298
Top Cited PapersEffects of Early Empagliflozin Initiation on Diuresis and Kidney Function in Patients With Acute Decompensated Heart Failure (EMPAG-HF)
Background: Effective diuretic regimens using loop diuretics in patients with acute decompensated heart failure are often limited by the development of worsening kidney function. Sodium-glucose cotransporter-2 inhibitors induce glucosuria and sodium excretion with nephroprotective effects in patients with stable heart failure but their role in acute decompensated heart failure is unclear. Methods: In this single-center, prospective, double-blind, placebo-controlled, randomized study, we randomly assigned patients with acute decompensated heart failure to empagliflozin 25 mg daily or placebo in addition to standard decongestive treatments that included loop diuretics. The primary end point was cumulative urine output over 5 days. Secondary end points included diuretic efficiency, dynamics in markers of kidney function and injury, and NT-proBNP (N-terminal pro-B-type natriuretic peptide). Results: Sixty patients were randomized within 12 hours of hospitalization for acute decompensated heart failure. Addition of empagliflozin daily to standard medical treatment of acute decompensated heart failure resulted in a 25% increase in cumulative urine output over 5 days (median 10.8 versus 8.7 L mL in placebo, group difference estimation 2.2 L [95% CI, 8.4 to 3.6]; P =0.003). Empagliflozin increased diuretic efficiency compared with placebo (14.1 mL urine per milligram furosemide equivalent [95% CI, 0.6–27.7]; P =0.041) without affecting markers of renal function (estimated glomerular filtration rate, 51±19 versus 54±17 mL/min per 1.73 m²; P =0.599) or injury (total urinary protein, 492±845 versus 503±847 mg/g creatinine; P =0.975; and urinary α1-microglobulin, 55.4±38.6 versus 31.3±33.6 mg/g creatinine; P =0.066) with more pronounced decrease in NT-proBNP in the empagliflozin group compared with placebo (−1861 versus −727.2 pg/mL after 5 days; quotient in slope, 0.89 [95% CI, 0.83–0.95]; P <0.001). There were no differences in the incidence of safety events between groups. Conclusions: Early addition of empagliflozin to standard diuretic therapy increases urine output without affecting renal function in patients with acute decompensated heart failure. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04049045.
- 30 June 2022
- Published by Springer Nature
- p. 1-17
Akute Herzinsuffizienz und kardiale Dekompensation
- Open Access
- 18 February 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (4) , 1059
A Novel Echocardiographic-Based Classification for the Prediction of Peri-Device Leakage following Left Atrial Appendage Occluder Implantation
(1) Background: The assessment of residual peri-device leakages (PDL) after left atrial appendage occlusion (LAAO) remains crucial for post-procedural management. Our study aimed to verify a novel echocardiographic classification for the prediction of PDL. (2) Methods: Echocardiographic data of 72 patients who underwent percutaneous LAAO were evaluated. All echo images were analyzed by two independent investigators using standard analysis software (Image-Arena IA-4.6.4.44 by TomTec®, Munich, Germany). A total number of 127 studies was evaluated. Forty-four patients had baseline studies, at 45 days and at 6 months post-implantation. We propose a morphological classification of LAA devices based on the amount of echodensity inside the devices into three types: type A showing complete homogenous thrombosis, type B incompletely thrombosed device with inhomogeneous echo-free space 50% of device in various planes, which we called the “ice-cream cone” sign. Each type was matched to the degree of PDL and clinical outcome parameters. (3) Results: Patients with type C had the highest percentage of PDL at 45 days follow-up (type A: 24%, type B: 31%, type C 100% PDL, p < 0.001) and at 6 months follow-up (type A: 7%, type B: 33%, type C 100% PDL, p < 0.001). Notably, device size in patients with PDL was larger than that in patients without PDL at 6 months follow-up (25.6 ± 3.5 mm vs. 28.7 ± 3.4 mm, p = 0.004). Device size in patients with type C appearance was the largest of the three types (type A: 25.9 ± 3.6 mm, type B: 25.8 ± 3.4 mm, type C 29.8 ± 3.0 mm, type A vs. C; p = 0.019; type B vs. C, p = 0.007). (4) Conclusions: In conclusion, PDL are common post-LAAO, and their frequency is underestimated and under-recognized. PDL are much more common in patients with larger LAA ostial sizes and likely lower longitudinal compression. Type C appearance of the LAAO devices (“ice-cream cone sign”) has a high positive predictive value for PDL. Further studies are needed for better delineation of the clinical importance of this proposed classification.
- 18 February 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (4) , 1059
Open AccessA Novel Echocardiographic-Based Classification for the Prediction of Peri-Device Leakage following Left Atrial Appendage Occluder Implantation
(1) Background: The assessment of residual peri-device leakages (PDL) after left atrial appendage occlusion (LAAO) remains crucial for post-procedural management. Our study aimed to verify a novel echocardiographic classification for the prediction of PDL. (2) Methods: Echocardiographic data of 72 patients who underwent percutaneous LAAO were evaluated. All echo images were analyzed by two independent investigators using standard analysis software (Image-Arena IA-4.6.4.44 by TomTec®, Munich, Germany). A total number of 127 studies was evaluated. Forty-four patients had baseline studies, at 45 days and at 6 months post-implantation. We propose a morphological classification of LAA devices based on the amount of echodensity inside the devices into three types: type A showing complete homogenous thrombosis, type B incompletely thrombosed device with inhomogeneous echo-free space 50% of device in various planes, which we called the “ice-cream cone” sign. Each type was matched to the degree of PDL and clinical outcome parameters. (3) Results: Patients with type C had the highest percentage of PDL at 45 days follow-up (type A: 24%, type B: 31%, type C 100% PDL, p < 0.001) and at 6 months follow-up (type A: 7%, type B: 33%, type C 100% PDL, p < 0.001). Notably, device size in patients with PDL was larger than that in patients without PDL at 6 months follow-up (25.6 ± 3.5 mm vs. 28.7 ± 3.4 mm, p = 0.004). Device size in patients with type C appearance was the largest of the three types (type A: 25.9 ± 3.6 mm, type B: 25.8 ± 3.4 mm, type C 29.8 ± 3.0 mm, type A vs. C; p = 0.019; type B vs. C, p = 0.007). (4) Conclusions: In conclusion, PDL are common post-LAAO, and their frequency is underestimated and under-recognized. PDL are much more common in patients with larger LAA ostial sizes and likely lower longitudinal compression. Type C appearance of the LAAO devices (“ice-cream cone sign”) has a high positive predictive value for PDL. Further studies are needed for better delineation of the clinical importance of this proposed classification.