Jialin Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jialin Song has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Shichao Jiang
Department of Orthopedics, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, 250021, China
2 shared publications - Cunyi Fan
Department of Orthopaedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China
1 shared publication - Cunyi Fan
Department of Orthopaedics, Shanghai Jiaotong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, China
1 shared publication - Dapeng Fan
Department of Orthopaedics, Shanghai Jiaotong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, China
1 shared publication - Fengfeng Li
Department of Orthopaedics, Shanghai Jiaotong University Affiliated Sixth People's Hospital, 600 Yishan Road, Shanghai 200233, PR China
1 shared publication - Guoqing Pan
Institute for Advanced Materials, School of Materials Science and Engineering, Jiangsu University, Zhenjiang, Jiangsu, 212013, PR China
1 shared publication
Latest Publications
- 11 May 2023
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 646, 399-412
Graphdiyne-loaded polycaprolactone nanofiber scaffold for peripheral nerve regeneration
- 11 May 2023
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 646, 399-412
Graphdiyne-loaded polycaprolactone nanofiber scaffold for peripheral nerve regeneration
- Open Access
- 1 May 2023
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 106, 108176
Free fillet flap transplantation using amputated upper limbs for shoulder defect coverage and joint function salvage in emergency treatment—A case report
Severe limb trauma results in mangled extremities, amputation, uncovered wound and delayed healing. The rapid development of flap transplantation concept and technique leads to applications of free flap in the salvage of limb and articular appearance and functions. This report discusses the case of a patient with acute shoulder avulsion and smashed injuries and evaluates the feasibility and safety of free fillet flap transplantation in emergency treatment. A 44-year-old man presented with acute traumatic severing injury to the left arm. We performed free fillet flap transplantation from the amputated forearms to retain the structure of shoulder joint and coverage of humerus in a patient who suffered from acute shoulder avulsion and smashed injuries. Moreover, we evaluated the long-term outcomes at 2-year follow-up and confirmed the functional adaptivity of proximal stump of the shoulder joint. The free fillet flap application is an important and advanced technique to cover large areas of skin and soft tissue defects in a mangled upper limb. It requires an experienced microsurgeon to achieve vessel reconnection, flap transfer and wound repair. In such an emergency case like this one, it calls for collaboration between different departments to work out a delicate and comprehensive plan in order to obtain the best possible result for saving patients. The free fillet flap transfer in this report is feasible and useful for shoulder defect coverage and joint function salvage in emergency treatment.
- 1 May 2023
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 106, 108176
Open AccessFree fillet flap transplantation using amputated upper limbs for shoulder defect coverage and joint function salvage in emergency treatment—A case report
Severe limb trauma results in mangled extremities, amputation, uncovered wound and delayed healing. The rapid development of flap transplantation concept and technique leads to applications of free flap in the salvage of limb and articular appearance and functions. This report discusses the case of a patient with acute shoulder avulsion and smashed injuries and evaluates the feasibility and safety of free fillet flap transplantation in emergency treatment. A 44-year-old man presented with acute traumatic severing injury to the left arm. We performed free fillet flap transplantation from the amputated forearms to retain the structure of shoulder joint and coverage of humerus in a patient who suffered from acute shoulder avulsion and smashed injuries. Moreover, we evaluated the long-term outcomes at 2-year follow-up and confirmed the functional adaptivity of proximal stump of the shoulder joint. The free fillet flap application is an important and advanced technique to cover large areas of skin and soft tissue defects in a mangled upper limb. It requires an experienced microsurgeon to achieve vessel reconnection, flap transfer and wound repair. In such an emergency case like this one, it calls for collaboration between different departments to work out a delicate and comprehensive plan in order to obtain the best possible result for saving patients. The free fillet flap transfer in this report is feasible and useful for shoulder defect coverage and joint function salvage in emergency treatment.
- Open Access
- 26 March 2015
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 16 (4) , 6932-6944
Multi-Layer Electrospun Membrane Mimicking Tendon Sheath for Prevention of Tendon Adhesions
Defect of the tendon sheath after tendon injury is a main reason for tendon adhesions, but it is a daunting challenge for the biomimetic substitute of the tendon sheath after injury due to its multi-layer membrane-like structure and complex biologic functions. In this study, a multi-layer membrane with celecoxib-loaded poly(l-lactic acid)-polyethylene glycol (PELA) electrospun fibrous membrane as the outer layer, hyaluronic acid (HA) gel as middle layer, and PELA electrospun fibrous membrane as the inner layer was designed. The anti-adhesion efficacy of this multi-layer membrane was compared with a single-layer use in rabbit flexor digitorum profundus tendon model. The surface morphology showed that both PELA fibers and celecoxib-loaded PELA fibers in multi-layer membrane were uniform in size, randomly arrayed, very porous, and smooth without beads. Multi-layer membrane group had fewer peritendinous adhesions and better gliding than the PELA membrane group and control group in gross and histological observation. The similar mechanical characteristic and collagen expression of tendon repair site in the three groups indicated that the multi-layer membrane did not impair tendon healing. Taken together, our results demonstrated that such a biomimetic multi-layer sheath could be used as a potential strategy in clinics for promoting tendon gliding and preventing adhesion without poor tendon healing.
- 26 March 2015
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 16 (4) , 6932-6944
Open AccessMulti-Layer Electrospun Membrane Mimicking Tendon Sheath for Prevention of Tendon Adhesions
Defect of the tendon sheath after tendon injury is a main reason for tendon adhesions, but it is a daunting challenge for the biomimetic substitute of the tendon sheath after injury due to its multi-layer membrane-like structure and complex biologic functions. In this study, a multi-layer membrane with celecoxib-loaded poly(l-lactic acid)-polyethylene glycol (PELA) electrospun fibrous membrane as the outer layer, hyaluronic acid (HA) gel as middle layer, and PELA electrospun fibrous membrane as the inner layer was designed. The anti-adhesion efficacy of this multi-layer membrane was compared with a single-layer use in rabbit flexor digitorum profundus tendon model. The surface morphology showed that both PELA fibers and celecoxib-loaded PELA fibers in multi-layer membrane were uniform in size, randomly arrayed, very porous, and smooth without beads. Multi-layer membrane group had fewer peritendinous adhesions and better gliding than the PELA membrane group and control group in gross and histological observation. The similar mechanical characteristic and collagen expression of tendon repair site in the three groups indicated that the multi-layer membrane did not impair tendon healing. Taken together, our results demonstrated that such a biomimetic multi-layer sheath could be used as a potential strategy in clinics for promoting tendon gliding and preventing adhesion without poor tendon healing.
- 1 December 2014
- Published by Elsevier in Biomaterials
- Vol. 35 (37) , 9920-9929
Down-regulating ERK1/2 and SMAD2/3 phosphorylation by physical barrier of celecoxib-loaded electrospun fibrous membranes prevents tendon adhesions
- 1 December 2014
- Published by Elsevier in Biomaterials
- Vol. 35 (37) , 9920-9929
Down-regulating ERK1/2 and SMAD2/3 phosphorylation by physical barrier of celecoxib-loaded electrospun fibrous membranes prevents tendon adhesions