Michael Döring
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael Döring has a total of 182 co-authors. Here are the top co-authors by number of shared publications:
Gerhard Hindricks
Department of Electrophysiology, Heart Center University of Leipzig Leipzig Germany
30 shared publicationsSergio Richter
Department of Electrophysiology, Heart Center University of Leipzig Leipzig Germany
22 shared publicationsPhilipp Sommer
Electrophysiology, Heart Center Leipzig, Leipzig, Germany
14 shared publicationsAndreas Bollmann
Electrophysiology, Heart Center Leipzig, Leipzig, Germany
13 shared publicationsArash Arya
Electrophysiology, University of Leipzig, Heart Center, Leipzig, Germany
11 shared publicationsSascha Rolf
DRK Kliniken Berlin Westend, Berlin, Germany
9 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 12 June 2024
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 45 (30) , 2771-2781
Therapy duration and improvement of ventricular function in de novo heart failure: the Heart Failure Optimization study
In patients with de novo heart failure with reduced ejection fraction (HFrEF), improvement of left ventricular ejection fraction (LVEF) is expected to occur when started on guideline-recommended medical therapy. However, improvement may not be completed within 90 days. Patients with HFrEF and LVEF ≤ 35% prescribed a wearable cardioverter-defibrillator between 2017 and 2022 from 68 sites were enrolled, starting with a registry phase for 3 months and followed by a study phase up to 1 year. The primary endpoints were LVEF improvement > 35% between Days 90 and 180 following guideline-recommended medical therapy initiation and the percentage of target dose reached at Days 90 and 180. A total of 598 patients with de novo HFrEF [59 years (interquartile range 51–68), 27% female] entered the study phase. During the first 180 days, a significant increase in dosage of beta-blockers, renin–angiotensin system inhibitors, and mineralocorticoid receptor antagonists was observed (P < .001). At Day 90, 46% [95% confidence interval (CI) 41%–50%] of study phase patients had LVEF improvement > 35%; 46% (95% CI 40%–52%) of those with persistently low LVEF at Day 90 had LVEF improvement > 35% by Day 180, increasing the total rate of improvement > 35% to 68% (95% CI 63%–72%). In 392 patients followed for 360 days, improvement > 35% was observed in 77% (95% CI 72%–81%) of the patients. Until Day 90, sustained ventricular tachyarrhythmias were observed in 24 wearable cardioverter-defibrillator carriers (1.8%). After 90 days, no sustained ventricular tachyarrhythmia occurred in wearable cardioverter-defibrillator carriers. Continuous optimization of guideline-recommended medical therapy for at least 180 days in HFrEF is associated with additional LVEF improvement > 35%, allowing for better decision-making regarding preventive implantable cardioverter-defibrillator therapy. Summary of design and results of Heart Failure Optimization study. Median left ventricular ejection fraction and percentage of patients with left ventricular ejection fraction > 35% at baseline, Days 90, 180, and 360. GRMT, guideline-recommended medical therapy; HFrEF, heart failure with reduced ejection fraction; LVEF, left ventricular ejection fraction; WCD, wearable cardioverter-defibrillator.
- 12 June 2024
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 45 (30) , 2771-2781
Top Cited PapersOpen AccessTherapy duration and improvement of ventricular function in de novo heart failure: the Heart Failure Optimization study
In patients with de novo heart failure with reduced ejection fraction (HFrEF), improvement of left ventricular ejection fraction (LVEF) is expected to occur when started on guideline-recommended medical therapy. However, improvement may not be completed within 90 days. Patients with HFrEF and LVEF ≤ 35% prescribed a wearable cardioverter-defibrillator between 2017 and 2022 from 68 sites were enrolled, starting with a registry phase for 3 months and followed by a study phase up to 1 year. The primary endpoints were LVEF improvement > 35% between Days 90 and 180 following guideline-recommended medical therapy initiation and the percentage of target dose reached at Days 90 and 180. A total of 598 patients with de novo HFrEF [59 years (interquartile range 51–68), 27% female] entered the study phase. During the first 180 days, a significant increase in dosage of beta-blockers, renin–angiotensin system inhibitors, and mineralocorticoid receptor antagonists was observed (P < .001). At Day 90, 46% [95% confidence interval (CI) 41%–50%] of study phase patients had LVEF improvement > 35%; 46% (95% CI 40%–52%) of those with persistently low LVEF at Day 90 had LVEF improvement > 35% by Day 180, increasing the total rate of improvement > 35% to 68% (95% CI 63%–72%). In 392 patients followed for 360 days, improvement > 35% was observed in 77% (95% CI 72%–81%) of the patients. Until Day 90, sustained ventricular tachyarrhythmias were observed in 24 wearable cardioverter-defibrillator carriers (1.8%). After 90 days, no sustained ventricular tachyarrhythmia occurred in wearable cardioverter-defibrillator carriers. Continuous optimization of guideline-recommended medical therapy for at least 180 days in HFrEF is associated with additional LVEF improvement > 35%, allowing for better decision-making regarding preventive implantable cardioverter-defibrillator therapy. Summary of design and results of Heart Failure Optimization study. Median left ventricular ejection fraction and percentage of patients with left ventricular ejection fraction > 35% at baseline, Days 90, 180, and 360. GRMT, guideline-recommended medical therapy; HFrEF, heart failure with reduced ejection fraction; LVEF, left ventricular ejection fraction; WCD, wearable cardioverter-defibrillator.
- Open Access
- 30 December 2022
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (3) , 1068-1076
Electroanatomical mapping–guided left bundle branch area pacing in patients with structural heart disease and advanced conduction abnormalities
Left bundle branch area pacing (LBBAP) can be technically challenging and fluoroscopy-intense. Three-dimensional electroanatomical mapping (EAM) facilitates non-fluoroscopic lead navigation and electrogram mapping. We sought to prospectively evaluate the feasibility, safety, and outcomes of routine EAM-guided LBBAP in patients with structural heart disease (SHD) and advanced conduction abnormalities. Consecutive patients with SHD and conduction abnormalities who underwent an attempt at EAM-guided LBBAP were included. The feasibility, safety, procedural, and mid-term outcomes were evaluated. Electrical, echocardiographic, and clinical parameters were assessed at implantation and last follow-up. Thirty-two patients (68 ± 18 years; 19% female) were included, of which 75% had intrinsic QRS > 150 ms, 53% left bundle branch block, and 25% right bundle branch block. Primary EAM-guided LBBAP was successful in 29 patients (91%). The procedural duration was 95 (70–110) min, total fluoroscopy time 0.93 (0.40–1.73) min, and total fluoroscopy dose 35.4 (20.5–77.2) cGy cm2. Paced QRS duration (QRSd) was significantly shorter than intrinsic QRSd (121.9 ± 10.7 vs. 159.2 ± 34.4 ms; P < 0.001) and remained stable during the mean follow-up of 7.0 ± 5.9 months. The LBBAP capture threshold was 0.57 ± 0.23 V/0.4 ms at implantation and remained low during follow-up (0.58 ± 0.18 V/0.5 ± 0.2 ms; P = 0.877). Overall left ventricular ejection fraction improved significantly from 44.2 ± 14.3% at baseline to 49.4 ± 13.1% at follow-up (P = 0.009), New York Heart Association class from 2.4 ± 0.6 to 1.8 ± 0.6 (P = 0.002), respectively. No complications occurred that required intervention. Routine near-zero fluoroscopy EAM-guided LBBAP can safely be performed in patients with SHD and advanced conduction abnormalities with high success rates and favourable mid-term outcomes. Further studies are needed to investigate whether the use of EAM improves the overall outcome of conduction system pacing and to identify specific patient populations who benefit the most from EAM-guided lead implantation.
- 30 December 2022
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (3) , 1068-1076
Open AccessElectroanatomical mapping–guided left bundle branch area pacing in patients with structural heart disease and advanced conduction abnormalities
Left bundle branch area pacing (LBBAP) can be technically challenging and fluoroscopy-intense. Three-dimensional electroanatomical mapping (EAM) facilitates non-fluoroscopic lead navigation and electrogram mapping. We sought to prospectively evaluate the feasibility, safety, and outcomes of routine EAM-guided LBBAP in patients with structural heart disease (SHD) and advanced conduction abnormalities. Consecutive patients with SHD and conduction abnormalities who underwent an attempt at EAM-guided LBBAP were included. The feasibility, safety, procedural, and mid-term outcomes were evaluated. Electrical, echocardiographic, and clinical parameters were assessed at implantation and last follow-up. Thirty-two patients (68 ± 18 years; 19% female) were included, of which 75% had intrinsic QRS > 150 ms, 53% left bundle branch block, and 25% right bundle branch block. Primary EAM-guided LBBAP was successful in 29 patients (91%). The procedural duration was 95 (70–110) min, total fluoroscopy time 0.93 (0.40–1.73) min, and total fluoroscopy dose 35.4 (20.5–77.2) cGy cm2. Paced QRS duration (QRSd) was significantly shorter than intrinsic QRSd (121.9 ± 10.7 vs. 159.2 ± 34.4 ms; P < 0.001) and remained stable during the mean follow-up of 7.0 ± 5.9 months. The LBBAP capture threshold was 0.57 ± 0.23 V/0.4 ms at implantation and remained low during follow-up (0.58 ± 0.18 V/0.5 ± 0.2 ms; P = 0.877). Overall left ventricular ejection fraction improved significantly from 44.2 ± 14.3% at baseline to 49.4 ± 13.1% at follow-up (P = 0.009), New York Heart Association class from 2.4 ± 0.6 to 1.8 ± 0.6 (P = 0.002), respectively. No complications occurred that required intervention. Routine near-zero fluoroscopy EAM-guided LBBAP can safely be performed in patients with SHD and advanced conduction abnormalities with high success rates and favourable mid-term outcomes. Further studies are needed to investigate whether the use of EAM improves the overall outcome of conduction system pacing and to identify specific patient populations who benefit the most from EAM-guided lead implantation.
- Open Access
- 10 September 2020
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 43 (11) , 1325-1332
Transvenous revision of leads with cardiac perforation following device implantation—Safety, outcome, and complications
Introduction: Cardiac perforation is a rare complication of cardiac implantable electronic device (CIED) implantation. Transvenous revision of perforated leads is associated with the risk of cardiac tamponade and death. Little is known about periprocedural complications and outcome of these patients.Methods and results: All patients referred to our department with evidence or suspicion of cardiac perforation following CIED implantation underwent chest X‐ray, transthoracic echocardiography, device interrogation, and, if necessary, a cardiac computed tomography (CT)‐scan to diagnose lead perforation and associated complications. Transvenous lead revision (TLR) was performed in all patients with evidence of lead perforation. Patient characteristics, procedural complications, and outcome were recorded and analyzed.Fifty‐six patients (75 ± 10 years, 43% male) were diagnosed with cardiac perforation, 34 patients (61%) early within 30 days post‐implantation, and 22 patients (39%) thereafter. The most frequent perforation site was the right ventricular (RV) apex (75%), followed by the RV free wall (16%) and the right atrial appendage (9%). A total of 16 patients (29%) presented with severe complications; 12 patients (21%) with pericardial effusion treated by pericardiocentesis before lead revision and four patients (7%) with hematothorax requiring drainage. Late perforations showed significantly more frequent cardiac tamponades (P = .041). TLR was performed without further complications in 54 patients (96%). None of the patients required surgical treatment or experienced in‐hospital death.Conclusions: Cardiac perforation following CIED implantation is associated with severe complications in nearly one‐third of the cases. Transvenous revision of the perforated lead can safely be performed with a very low complication rate.
- 10 September 2020
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 43 (11) , 1325-1332
Open AccessTransvenous revision of leads with cardiac perforation following device implantation—Safety, outcome, and complications
Introduction: Cardiac perforation is a rare complication of cardiac implantable electronic device (CIED) implantation. Transvenous revision of perforated leads is associated with the risk of cardiac tamponade and death. Little is known about periprocedural complications and outcome of these patients.Methods and results: All patients referred to our department with evidence or suspicion of cardiac perforation following CIED implantation underwent chest X‐ray, transthoracic echocardiography, device interrogation, and, if necessary, a cardiac computed tomography (CT)‐scan to diagnose lead perforation and associated complications. Transvenous lead revision (TLR) was performed in all patients with evidence of lead perforation. Patient characteristics, procedural complications, and outcome were recorded and analyzed.Fifty‐six patients (75 ± 10 years, 43% male) were diagnosed with cardiac perforation, 34 patients (61%) early within 30 days post‐implantation, and 22 patients (39%) thereafter. The most frequent perforation site was the right ventricular (RV) apex (75%), followed by the RV free wall (16%) and the right atrial appendage (9%). A total of 16 patients (29%) presented with severe complications; 12 patients (21%) with pericardial effusion treated by pericardiocentesis before lead revision and four patients (7%) with hematothorax requiring drainage. Late perforations showed significantly more frequent cardiac tamponades (P = .041). TLR was performed without further complications in 54 patients (96%). None of the patients required surgical treatment or experienced in‐hospital death.Conclusions: Cardiac perforation following CIED implantation is associated with severe complications in nearly one‐third of the cases. Transvenous revision of the perforated lead can safely be performed with a very low complication rate.
- 1 June 2020
- Published by Elsevier in International Journal of Cardiology
- Vol. 309, 84-91
Extraction of infected cardiac implantable electronic devices and the need for subsequent re-implantation
- 1 June 2020
- Published by Elsevier in International Journal of Cardiology
- Vol. 309, 84-91
Extraction of infected cardiac implantable electronic devices and the need for subsequent re-implantation
- 9 January 2020
- Published by Walter de Gruyter GmbH in Diagnosis
- Vol. 8 (3) , 295-303
Atrial fibrillation: is there a role for cardiac troponin?
Atrial fibrillation (AF) is the most common sustained arrhythmia, and its prevalence rate is expected to be doubled over the next decades. Despite the wide use of biomarkers in the management of different cardiac diseases such as myocardial infarction and heart failure, utilization of biomarkers in AF management is not routinely recommended by current guidelines. There is also growing evidence that higher levels of cardiac-specific troponin, as an intracellular protein involved in cardiomyocyte contraction, may be associated with the risk of incident and recurrent AF and its complications. In the present paper, we review the association between troponin and AF and propose clinical suggestions for use of troponin in the management of AF patients.
- 9 January 2020
- Published by Walter de Gruyter GmbH in Diagnosis
- Vol. 8 (3) , 295-303
Atrial fibrillation: is there a role for cardiac troponin?
Atrial fibrillation (AF) is the most common sustained arrhythmia, and its prevalence rate is expected to be doubled over the next decades. Despite the wide use of biomarkers in the management of different cardiac diseases such as myocardial infarction and heart failure, utilization of biomarkers in AF management is not routinely recommended by current guidelines. There is also growing evidence that higher levels of cardiac-specific troponin, as an intracellular protein involved in cardiomyocyte contraction, may be associated with the risk of incident and recurrent AF and its complications. In the present paper, we review the association between troponin and AF and propose clinical suggestions for use of troponin in the management of AF patients.
- 23 July 2019
- Published by Georg Thieme Verlag KG in International Journal of Sports Medicine
- Vol. 40 (10) , 657-662
Effect of Exercise on Outcome after Ventricular Tachycardia Ablation in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy
Competitive sports and intensive exercise are associated with adverse outcomes in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C). This study aimed to assess the role of exercise on long-term results of radiofrequency catheter ablation (RFCA) therapy of ventricular tachycardia (VT) in patients with ARVD/C. Exercise participation was evaluated by telephone or in-person interviews in patients from our ARVD/C registry with previous VT ablation (38 patients, 26 males, age 52.6±14.1years). Of 38 patients, 30 were involved in sports activities before RFCA. Only the minority of our patient population (21.1%) had a sedentary lifestyle before RFCA; 42.1 and 36.8% reported recreational or competitive sports, respectively. During the follow-up period of 52.5±31.4 months, 23 of the total 38 patients with previous RFCA (60.5%) remained free from VT recurrence. In univariate and binary logistic regression analysis, only advanced age was significantly associated with VT recurrence, with a hazard ratio of 1.15, and 95% confidence interval 1.05–1.26 (p=0.004). The results of our observational study indicate that recreational sports do not impair long-term results after RFCA treatment compared with a sedentary lifestyle. Furthermore, the dynamic component of recreational exercise did not affect the outcome of VT ablation in our patient population. Recreational exercise at low to moderate intensity is not associated with an increased risk for VT recurrence after catheter ablation in patients with ARVD/C.
- 23 July 2019
- Published by Georg Thieme Verlag KG in International Journal of Sports Medicine
- Vol. 40 (10) , 657-662
Effect of Exercise on Outcome after Ventricular Tachycardia Ablation in Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy
Competitive sports and intensive exercise are associated with adverse outcomes in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C). This study aimed to assess the role of exercise on long-term results of radiofrequency catheter ablation (RFCA) therapy of ventricular tachycardia (VT) in patients with ARVD/C. Exercise participation was evaluated by telephone or in-person interviews in patients from our ARVD/C registry with previous VT ablation (38 patients, 26 males, age 52.6±14.1years). Of 38 patients, 30 were involved in sports activities before RFCA. Only the minority of our patient population (21.1%) had a sedentary lifestyle before RFCA; 42.1 and 36.8% reported recreational or competitive sports, respectively. During the follow-up period of 52.5±31.4 months, 23 of the total 38 patients with previous RFCA (60.5%) remained free from VT recurrence. In univariate and binary logistic regression analysis, only advanced age was significantly associated with VT recurrence, with a hazard ratio of 1.15, and 95% confidence interval 1.05–1.26 (p=0.004). The results of our observational study indicate that recreational sports do not impair long-term results after RFCA treatment compared with a sedentary lifestyle. Furthermore, the dynamic component of recreational exercise did not affect the outcome of VT ablation in our patient population. Recreational exercise at low to moderate intensity is not associated with an increased risk for VT recurrence after catheter ablation in patients with ARVD/C.
- 21 June 2019
- Published by Springer Nature in Heart and Vessels
- Vol. 35 (1) , 104-109
Outcome in patients undergoing upgrade to cardiac resynchronization therapy: predictors of outcome after upgrade to CRT
The advantages of upgrade to cardiac resynchronisation therapy (CRT) have not been explored as carefully as the outcomes of de novo CRT implantations. Furthermore selection criteria for patients with the potential to benefit the most from this therapy are unknown. Therefore, we analyzed the long term outcome and its predictors in a real-world cohort receiving a CRT upgrade from previous pacemaker (PM) and defibrillator devices (ICD). We analyzed 86 patients (mean age 68 ± 9 years; 89% male) undergoing CRT upgrade procedures. Response to CRT as well as long term patient outcome was analyzed. NYHA class improved in majority of the patients during short term period (61%), and this trend remained constant during long term follow-up (54%). The observed all-cause mortality was 54% with mean survival of 49 ± 4 months. 11 patients underwent left ventricular assist device implantation or heart transplantation. In the multivariate analysis, only kidney function assessed by GFR (HR 0.97; 95% CI 0.95–0.99; p = 0.009) and LVEF (HR 0.92; 95% CI 0.87–0.97; p = 0.002) remain predictors for mortality. Patients who undergo an upgrade procedure to CRT demonstrate a significant response rate assessed by improvement in NYHA class, with initial baseline parameters such as LVEF and kidney function remaining significant predictors for mortality.
- 21 June 2019
- Published by Springer Nature in Heart and Vessels
- Vol. 35 (1) , 104-109
Outcome in patients undergoing upgrade to cardiac resynchronization therapy: predictors of outcome after upgrade to CRT
The advantages of upgrade to cardiac resynchronisation therapy (CRT) have not been explored as carefully as the outcomes of de novo CRT implantations. Furthermore selection criteria for patients with the potential to benefit the most from this therapy are unknown. Therefore, we analyzed the long term outcome and its predictors in a real-world cohort receiving a CRT upgrade from previous pacemaker (PM) and defibrillator devices (ICD). We analyzed 86 patients (mean age 68 ± 9 years; 89% male) undergoing CRT upgrade procedures. Response to CRT as well as long term patient outcome was analyzed. NYHA class improved in majority of the patients during short term period (61%), and this trend remained constant during long term follow-up (54%). The observed all-cause mortality was 54% with mean survival of 49 ± 4 months. 11 patients underwent left ventricular assist device implantation or heart transplantation. In the multivariate analysis, only kidney function assessed by GFR (HR 0.97; 95% CI 0.95–0.99; p = 0.009) and LVEF (HR 0.92; 95% CI 0.87–0.97; p = 0.002) remain predictors for mortality. Patients who undergo an upgrade procedure to CRT demonstrate a significant response rate assessed by improvement in NYHA class, with initial baseline parameters such as LVEF and kidney function remaining significant predictors for mortality.
- Open Access
- 25 May 2019
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 21 (8) , 1220-1228
Cardiovascular magnetic resonance imaging in patients with cardiac implantable electronic devices: best practice and real-world experience
Cardiovascular magnetic resonance (CMR) imaging has long been a contraindication for patients with a cardiac implantable electronic device (CIED). Recent studies support the feasibility and safety for non-thoracic magnetic resonance imaging, but data for CMR are sparse. The aim of the current study was to determine the safety in patients with magnetic resonance (MR)-conditional or non-MR-conditional CIED and to develop a best practice approach. All patients with a CIED undergoing CMR imaging (1.5 T) between April 2014 and April 2017 were included in the study. Devices were programmed according to the standardized protocol directly before and after the CMR examination. Follow-up interrogation was performed 6 months after CMR examination. Results were compared with a large, reference cohort of CIED patients not undergoing any MR examination. A total of 200 consecutive patients with a CIED (non-MR-conditional, n = 103) were included in the study. Directly after CMR imaging, one device failure (0.5%, battery status = end of service) was noted necessitating premature generator replacement. In three patients (2%) of pacemaker/implantable cardioverter-defibrillator (ICD) carriers a sustained ventricular tachycardia (VT) occurred during CMR imaging. Ten ICD showed a decrease in battery capacity immediately after CMR. Overall, the reference cohort showed comparable changes of CIED function during follow-up. With adherence to a standardized protocol and established exclusion criteria CMR imaging could safely be performed in patients with a CIED. The potential risks of device malfunction necessitate the presence of a device trained individual during the entire CMR examination. If there is a history of VT storm the attendance of an experienced cardiologist, should be mandatory.
- 25 May 2019
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 21 (8) , 1220-1228
Open AccessCardiovascular magnetic resonance imaging in patients with cardiac implantable electronic devices: best practice and real-world experience
Cardiovascular magnetic resonance (CMR) imaging has long been a contraindication for patients with a cardiac implantable electronic device (CIED). Recent studies support the feasibility and safety for non-thoracic magnetic resonance imaging, but data for CMR are sparse. The aim of the current study was to determine the safety in patients with magnetic resonance (MR)-conditional or non-MR-conditional CIED and to develop a best practice approach. All patients with a CIED undergoing CMR imaging (1.5 T) between April 2014 and April 2017 were included in the study. Devices were programmed according to the standardized protocol directly before and after the CMR examination. Follow-up interrogation was performed 6 months after CMR examination. Results were compared with a large, reference cohort of CIED patients not undergoing any MR examination. A total of 200 consecutive patients with a CIED (non-MR-conditional, n = 103) were included in the study. Directly after CMR imaging, one device failure (0.5%, battery status = end of service) was noted necessitating premature generator replacement. In three patients (2%) of pacemaker/implantable cardioverter-defibrillator (ICD) carriers a sustained ventricular tachycardia (VT) occurred during CMR imaging. Ten ICD showed a decrease in battery capacity immediately after CMR. Overall, the reference cohort showed comparable changes of CIED function during follow-up. With adherence to a standardized protocol and established exclusion criteria CMR imaging could safely be performed in patients with a CIED. The potential risks of device malfunction necessitate the presence of a device trained individual during the entire CMR examination. If there is a history of VT storm the attendance of an experienced cardiologist, should be mandatory.
- 18 May 2019
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 21 (8) , 1246-1253
Deep sedation for transvenous lead extraction: a large single-centre experience
Aims: Transvenous lead extraction for cardiac implantable electronic devices (CIED) is of growing importance. Nevertheless, the optimal anaesthetic approach, general anaesthesia vs. deep sedation (DS), remains unresolved. We describe our tertiary centre experience of the feasibility and safety of DS. Methods and results: Extraction procedures were performed in the electrophysiology (EP) laboratory by two experienced electrophysiologists. We used intravenous Fentanyl, Midazolam, and Propofol for DS. A stepwise approach with locking stylets, dilator sheaths, and mechanical sheaths via subclavian, femoral, or internal jugular venous access was utilized. Patient characteristics and procedural data were collected. Logistic regression models were used to identify parameters associated with sedation-related complications. Extraction of 476 leads (dwelling time/patient 88 ± 49 months, 30% ICD leads) was performed in 220 patients (64 ± 17 years, 80% male). Deep sedation was initiated with bolus administration of Fentanyl, Midazolam, and Propofol; mean doses 0.34 ± 0.12 μg/kg, 24.3 ± 6.8 μg/kg, and 0.26 ± 0.13 mg/kg, respectively. Deep sedation was maintained with continuous Propofol infusion (initial dose 3.7 ± 1.1 mg/kg/h; subsequently increased to 4.7 ± 1.2 mg/kg/h with 3.9 ± 2.6 adjustments) and boluses of Midazolam and Fentanyl as indicated. Sedation-related episodes of hypotension, requiring vasopressors, and hypoxia, requiring additional airway management, occurred in 25 (11.4%) and 5 (2.3%) patients, respectively. These were managed without adverse consequences. Five patients (2.3%) experienced major intraprocedural complications; there were no procedure-related deaths. All of our logistic regression models indicated intraprocedural support was associated with administration higher Fentanyl doses. Conclusion: Transvenous lead extraction under DS in the EP laboratory is a safe procedure with high success rates when performed by experienced staff.
- 18 May 2019
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 21 (8) , 1246-1253
Deep sedation for transvenous lead extraction: a large single-centre experience
Aims: Transvenous lead extraction for cardiac implantable electronic devices (CIED) is of growing importance. Nevertheless, the optimal anaesthetic approach, general anaesthesia vs. deep sedation (DS), remains unresolved. We describe our tertiary centre experience of the feasibility and safety of DS. Methods and results: Extraction procedures were performed in the electrophysiology (EP) laboratory by two experienced electrophysiologists. We used intravenous Fentanyl, Midazolam, and Propofol for DS. A stepwise approach with locking stylets, dilator sheaths, and mechanical sheaths via subclavian, femoral, or internal jugular venous access was utilized. Patient characteristics and procedural data were collected. Logistic regression models were used to identify parameters associated with sedation-related complications. Extraction of 476 leads (dwelling time/patient 88 ± 49 months, 30% ICD leads) was performed in 220 patients (64 ± 17 years, 80% male). Deep sedation was initiated with bolus administration of Fentanyl, Midazolam, and Propofol; mean doses 0.34 ± 0.12 μg/kg, 24.3 ± 6.8 μg/kg, and 0.26 ± 0.13 mg/kg, respectively. Deep sedation was maintained with continuous Propofol infusion (initial dose 3.7 ± 1.1 mg/kg/h; subsequently increased to 4.7 ± 1.2 mg/kg/h with 3.9 ± 2.6 adjustments) and boluses of Midazolam and Fentanyl as indicated. Sedation-related episodes of hypotension, requiring vasopressors, and hypoxia, requiring additional airway management, occurred in 25 (11.4%) and 5 (2.3%) patients, respectively. These were managed without adverse consequences. Five patients (2.3%) experienced major intraprocedural complications; there were no procedure-related deaths. All of our logistic regression models indicated intraprocedural support was associated with administration higher Fentanyl doses. Conclusion: Transvenous lead extraction under DS in the EP laboratory is a safe procedure with high success rates when performed by experienced staff.