Manfred M. Maurer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Manfred M. Maurer has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Feola
Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, United States
2 shared publications - Barbara Röhrnbauer
Institute of Mechanical Systems, ETH Zurich, Tannenstrasse 3, 8092 Zurich, Switzerland
2 shared publications E. Mazza
Department of Mechanical and Process Engineering, ETH Zurich, 8092 Zurich, Switzerland; EMPA, Swiss Federal Laboratories for Materials Testing and Research, 8600 Dubendorf, Switzerland
2 shared publications- Jan Deprest
UCL Elizabeth Garrett Anderson Institute for Women's Health University College London London UK
2 shared publications - Edoardo Mazza
Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf, Switzerland
1 shared publication M. Bajka
Department of Obstetrics and Gynecology, University Hospital Zurich, 8091 Zurich, Switzerland
1 shared publication
Latest Publications
- 1 June 2015
- Published by Elsevier in Journal of Biomechanics
- Vol. 48 (9) , 1541-1548
Challenging the in-vivo assessment of biomechanical properties of the uterine cervix: A critical analysis of ultrasound based quasi-static procedures
- 1 June 2015
- Published by Elsevier in Journal of Biomechanics
- Vol. 48 (9) , 1541-1548
Challenging the in-vivo assessment of biomechanical properties of the uterine cervix: A critical analysis of ultrasound based quasi-static procedures
- Open Access
Prosthetic Meshes for Repair of Hernia and Pelvic Organ Prolapse: Comparison of Biomechanical Properties
This study aims to compare the mechanical behavior of synthetic meshes used for pelvic organ prolapse (POP) and hernia repair. The analysis is based on a comprehensive experimental protocol, which included uniaxial and biaxial tension, cyclic loading and testing of meshes in dry conditions and embedded into an elastomer matrix. Implants are grouped as POP or hernia meshes, as indicated by the manufacturer, and their stiffness in different loading configurations, area density and porosity are compared. Hernia meshes might be expected to be stiffer, since they are implanted into a stiffer tissue (abdominal wall) than POP meshes (vaginal wall). Contrary to this, hernia meshes have a generally lower secant stiffness than POP meshes. For example, DynaMesh PRS, a POP mesh, is up to two orders of magnitude stiffer in all tested configurations than DynaMesh ENDOLAP, a hernia mesh. Additionally, lighter, large pore implants might be expected to be more compliant, which was shown to be generally not true. In particular, Restorelle, the lightest mesh with the largest pores, is less compliant in the tested configurations than Surgipro, the heaviest, small-pore implant. Our study raises the question of defining a meaningful design target for meshes in terms of mechanical biocompatibility.
Open AccessProsthetic Meshes for Repair of Hernia and Pelvic Organ Prolapse: Comparison of Biomechanical Properties
This study aims to compare the mechanical behavior of synthetic meshes used for pelvic organ prolapse (POP) and hernia repair. The analysis is based on a comprehensive experimental protocol, which included uniaxial and biaxial tension, cyclic loading and testing of meshes in dry conditions and embedded into an elastomer matrix. Implants are grouped as POP or hernia meshes, as indicated by the manufacturer, and their stiffness in different loading configurations, area density and porosity are compared. Hernia meshes might be expected to be stiffer, since they are implanted into a stiffer tissue (abdominal wall) than POP meshes (vaginal wall). Contrary to this, hernia meshes have a generally lower secant stiffness than POP meshes. For example, DynaMesh PRS, a POP mesh, is up to two orders of magnitude stiffer in all tested configurations than DynaMesh ENDOLAP, a hernia mesh. Additionally, lighter, large pore implants might be expected to be more compliant, which was shown to be generally not true. In particular, Restorelle, the lightest mesh with the largest pores, is less compliant in the tested configurations than Surgipro, the heaviest, small-pore implant. Our study raises the question of defining a meaningful design target for meshes in terms of mechanical biocompatibility.
- 1 December 2014
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 40, 42-58
Mechanical biocompatibility of prosthetic meshes: A comprehensive protocol for mechanical characterization
- 1 December 2014
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 40, 42-58
Mechanical biocompatibility of prosthetic meshes: A comprehensive protocol for mechanical characterization