HDHadrien Dyvorne

Hadrien Dyvorne

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hadrien Dyvorne has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Slice‐selective adiabatic magnetization T2‐preparation (SAMPA) for efficient T2‐weighted imaging at ultrahigh field strengths

    by Hadrien Dyvorne, Priti Balchandani

    Purpose: At high field, T2‐weighted (T2w) imaging is limited by transmit field inhomogeneity and increased radiofrequency power deposition. In this work, we introduce SAMPA (Slice‐selective Adiabatic Magnetization T2 PrepAration) and demonstrate its use for efficient brain T2w imaging at 7 Tesla (T).Methods: SAMPA was designed by subsampling an optimized B1 insensitive rotation (BIR4) waveform with small tip angle linear subpulses. To perform T2w imaging, SAMPA was inserted before a fast gradient echo acquisition. The off‐resonance behavior, B1 robustness, and slice selectivity of the novel T2 preparation module were analyzed using Bloch simulations. The performance of SAMPA for T2w imaging was demonstrated in phantom experiments as well as in the brains of healthy volunteers at 7T.Results: Based on simulations, the proposed design operates at peak B1 of 15 μT and higher, within a 400 Hz bandwidth. T2 values were in strong agreement with spin echo‐based T2 mapping in phantom experiments. Whole brain, interleaved multislab three‐dimensional imaging could be acquired with 0.8 mm3 isotropic resolution in 5:36 min per T2 weighting.Conclusion: Compared with previous adiabatic T2 preparation techniques, SAMPA allows for slice‐selectivity, which can lead to efficient and robust acquisitions for T2w imaging at high field. Magn Reson Med 76:1741–1749, 2016. © 2015 International Society for Magnetic Resonance in Medicine


  • Ultrahigh field single-refocused diffusion weighted imaging using a matched-phase adiabatic spin echo (MASE)

    by Hadrien Dyvorne, Rafael O'Halloran, Priti Balchandani

    To improve ultrahigh field diffusion-weighted imaging (DWI) in the presence of inhomogeneous transmit B1 field by designing a novel semi-adiabatic single-refocused DWI technique. A 180° slice-selective, adiabatic radiofrequency (RF) pulse of 4 ms duration was designed using the adiabatic Shinnar-Le Roux algorithm. A matched-phase slice-selective 90° RF pulse of 8 ms duration was designed to compensate the nonlinear phase of the adiabatic 180° RF pulse. The resulting RF pulse combination, matched-phase adiabatic spin echo (MASE), was integrated into a single-shot echo planar DWI sequence. The performance of this sequence was compared with single-refocused Stejskal-Tanner (ST), twice-refocused spin echo (TRSE) and twice-refocused adiabatic spin echo (TRASE) in simulations, phantoms, and healthy volunteers at 7 Tesla (T). In regions with inhomogeneous B1 , MASE resulted in increased signal intensity compared with ST (up to 64%). Moderate increase in specific absorption rate (35-39%) was observed for adiabatic RF pulses. MASE resulted in higher signal homogeneity at 7T, leading to improved visualization of measures derived from diffusion-weighted images such as white matter tractography and track density images. Efficient adiabatic SLR pulses can be adapted to single-refocused DWI, leading to substantially improved signal uniformity when compared with conventional acquisitions.


  • Abdominal 4D Flow MR Imaging in a Breath Hold: Combination of Spiral Sampling and Dynamic Compressed Sensing for Highly Accelerated Acquisition

    by Hadrien Dyvorne, Ashley Knight-Greenfield, Guido Jajamovich, Cecilia Besa, Yong Cui, Aurélien Stalder, Michael Markl, Bachir Taouli

    Combining highly efficient spiral sampling with dynamic compressed sensing results in major acceleration for four-dimensional flow MR imaging and allows comprehensive assessment of abdominal vessel hemodynamics in a single breath hold. PurposeTo develop a highly accelerated phase-contrast cardiac-gated volume flow measurement (four-dimensional [4D] flow) magnetic resonance (MR) imaging technique based on spiral sampling and dynamic compressed sensing and to compare this technique with established phase-contrast imaging techniques for the quantification of blood flow in abdominal vessels.Materials and MethodsThis single-center prospective study was compliant with HIPAA and approved by the institutional review board. Ten subjects (nine men, one woman; mean age, 51 years; age range, 30–70 years) were enrolled. Seven patients had liver disease. Written informed consent was obtained from all participants. Two 4D flow acquisitions were performed in each subject, one with use of Cartesian sampling with respiratory tracking and the other with use of spiral sampling and a breath hold. Cartesian two-dimensional (2D) cine phase-contrast images were also acquired in the portal vein. Two observers independently assessed vessel conspicuity on phase-c...


  • Diffusion-Weighted Imaging of the Liver in Patients With Chronic Liver Disease: Comparison of Monopolar and Bipolar Diffusion Gradients for Image Quality and Lesion Detection

    by Sara Lewis, Amita Kamath, Manjil Chatterji, Amish Patel, Inna Shyknevsky, Hadrien A. Dyvorne, Bernd Kuehn, Bachir Taouli

    The objective of our study was to compare diffusion-weighted imaging (DWI) sequences using a bipolar versus a monopolar single-shot echo-planar imaging (EPI) gradient design for image quality and for lesion detection and characterization in patients with liver disease.In this retrospective study, 77 patients with chronic liver disease who underwent MRI including bipolar and monopolar DWI at 1.5 T were assessed. Two independent observers reviewed the DWI studies for image quality and the detection and characterization of liver lesions. The reference standard for diagnosis was established by consensus review of two different observers using imaging characteristics on conventional MRI sequences, lesion stability over time, pathologic correlation, or a combination of these findings. The estimated signal-to-noise ratio (SNR) of liver parenchyma and apparent diffusion coefficients (ADCs) of the liver and lesions were calculated for both sequences. ROC analysis was conducted to evaluate the performance of ADC for the diagnosis of hepatocellular carcinoma (HCC).Eighty-five lesions, 50 HCCs and 35 benign lesions, were detected with the reference standard in 38 patients. There was equivalent image quality for the bipolar and monopolar sequences (p = 0.24-0.42). The HCC detection rate for observers 1 and 2 was slightly better with bipolar DWI (50.0% and 52.0%, respectively) compared with monopolar DWI (44.0% and 46.0%); however, this difference did not reach statistical significance. The estimated SNR was higher with the monopolar sequence than with the bipolar sequence (p ≤ 0.001). The AUC for the ROC curve was 0.691 for bipolar DWI and 0.649 for monopolar DWI when ADC was used for the characterization of HCC, which is not a statistically significant difference (p = 0.59).The higher estimated SNR yielded by the monopolar DWI sequence did not translate into better HCC detection compared with the bipolar DWI sequence. ADC has a limited role for HCC characterization in patients with liver disease.