Nicky Van Der Vekens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nicky Van Der Vekens has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Gunther van Loon
Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine Ghent University Ghent Belgium
18 shared publications A. Decloedt
Department of Large Animal Internal Medicine Faculty of Veterinary Medicine Ghent University Salisburylaan 133 9820 Merelbeke Belgium
9 shared publicationsD. De Clercq
Department of Large Animal Internal Medicine Faculty of Veterinary Medicine Ghent University Salisburylaan 133 9820 Merelbeke Belgium
9 shared publications- Annelies Decloedt
Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine Ghent University Ghent Belgium
7 shared publications S. Ven
Department of Large Animal Internal Medicine Faculty of Veterinary Medicine Ghent University Salisburylaan 133 9820 Merelbeke Belgium
7 shared publicationsD. de Clercq
Department of Large Animal Internal Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
4 shared publications
Latest Publications
- Open Access
- 20 December 2024
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 12, e60244
Building a Foundation for High-Quality Health Data: Multihospital Case Study in Belgium
Background: Data quality is fundamental to maintaining the trust and reliability of health data for both primary and secondary purposes. However, before the secondary use of health data, it is essential to assess the quality at the source and to develop systematic methods for the assessment of important data quality dimensions. Objective: This case study aims to offer a dual aim—to assess the data quality of height and weight measurements across 7 Belgian hospitals, focusing on the dimensions of completeness and consistency, and to outline the obstacles these hospitals face in sharing and improving data quality standards. Methods: Focusing on data quality dimensions completeness and consistency, this study examined height and weight data collected from 2021 to 2022 within 3 distinct departments—surgical, geriatrics, and pediatrics—in each of the 7 hospitals. Results: Variability was observed in the completeness scores for height across hospitals and departments, especially within surgical and geriatric wards. In contrast, weight data uniformly achieved high completeness scores. Notably, the consistency of height and weight data recording was uniformly high across all departments. Conclusions: A collective collaboration among Belgian hospitals, transcending network affiliations, was formed to conduct this data quality assessment. This study demonstrates the potential for improving data quality across health care organizations by sharing knowledge and good practices, establishing a foundation for future, similar research.
- 20 December 2024
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 12, e60244
Open AccessBuilding a Foundation for High-Quality Health Data: Multihospital Case Study in Belgium
Background: Data quality is fundamental to maintaining the trust and reliability of health data for both primary and secondary purposes. However, before the secondary use of health data, it is essential to assess the quality at the source and to develop systematic methods for the assessment of important data quality dimensions. Objective: This case study aims to offer a dual aim—to assess the data quality of height and weight measurements across 7 Belgian hospitals, focusing on the dimensions of completeness and consistency, and to outline the obstacles these hospitals face in sharing and improving data quality standards. Methods: Focusing on data quality dimensions completeness and consistency, this study examined height and weight data collected from 2021 to 2022 within 3 distinct departments—surgical, geriatrics, and pediatrics—in each of the 7 hospitals. Results: Variability was observed in the completeness scores for height across hospitals and departments, especially within surgical and geriatric wards. In contrast, weight data uniformly achieved high completeness scores. Notably, the consistency of height and weight data recording was uniformly high across all departments. Conclusions: A collective collaboration among Belgian hospitals, transcending network affiliations, was formed to conduct this data quality assessment. This study demonstrates the potential for improving data quality across health care organizations by sharing knowledge and good practices, establishing a foundation for future, similar research.
- Open Access
- 6 May 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Building a Foundation for High-Quality Health Data: A Multi-Hospital Study in Belgium (Preprint)
BACKGROUND Data quality is fundamental to maintain the trust and reliability of health data for both primary and secondary purposes. However, before secondary use of health data, it is essential to assess the quality at the source and to develop systematic methods for the assessment of important data quality dimensions. OBJECTIVE This case study aims to offer a dual aim: to assess the data quality of height and weight measurements across seven Belgian hospitals and to outline the obstacles these hospitals face in sharing and improving data quality standards METHODS Focusing on data quality dimensions completeness and consistency, this study examined height and weight data collected from 2021 to 2022 within three distinct departments – surgical, geriatrics, and paediatrics – in each of the seven hospitals. RESULTS Variability was observed in the completeness scores for height across hospitals and departments, especially within surgical and geriatric wards. In contrast, weight data uniformly achieved high completeness scores. Notably, the consistency of height and weight data recording was uniformly high across all departments. CONCLUSIONS A collective collaboration among Belgian hospitals, transcending network affiliations, was formed to conduct this data quality assessment. This study demonstrates the potential for improving data quality across healthcare organizations by sharing knowledge and good practices, establishing a foundation for future, similar research.
- 6 May 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessBuilding a Foundation for High-Quality Health Data: A Multi-Hospital Study in Belgium (Preprint)
BACKGROUND Data quality is fundamental to maintain the trust and reliability of health data for both primary and secondary purposes. However, before secondary use of health data, it is essential to assess the quality at the source and to develop systematic methods for the assessment of important data quality dimensions. OBJECTIVE This case study aims to offer a dual aim: to assess the data quality of height and weight measurements across seven Belgian hospitals and to outline the obstacles these hospitals face in sharing and improving data quality standards METHODS Focusing on data quality dimensions completeness and consistency, this study examined height and weight data collected from 2021 to 2022 within three distinct departments – surgical, geriatrics, and paediatrics – in each of the seven hospitals. RESULTS Variability was observed in the completeness scores for height across hospitals and departments, especially within surgical and geriatric wards. In contrast, weight data uniformly achieved high completeness scores. Notably, the consistency of height and weight data recording was uniformly high across all departments. CONCLUSIONS A collective collaboration among Belgian hospitals, transcending network affiliations, was formed to conduct this data quality assessment. This study demonstrates the potential for improving data quality across healthcare organizations by sharing knowledge and good practices, establishing a foundation for future, similar research.
- Open Access
- 1 July 2016
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 30 (4) , 1253-1259
Atrial Premature Depolarization-Induced Changes in QRS and T Wave Morphology on Resting Electrocardiograms in Horses
Background: The electrocardiographic differentiation between atrial (APDs) and ventricular (VPDs) premature depolarizations is important. P wave prematurity and normal QRS and T wave morphology generally are used as discriminating criteria for APDs. Hypothesis/Objectives: The aim of this study was to determine whether P, Q, R, S, and T wave amplitude, PQ interval, QRS and P wave duration and P and T wave morphology differ between APDs and sinus beats. To determine the relationship between the RR coupling interval and the change in S wave amplitude between sinus beats and APDs. Methods: Case–control study. From a modified base-apex configuration of 30 horses with APDs at rest, sinus beat and APD associated preceding RR interval, P, PQ and QRS duration and P, R, S, and T wave amplitudes were measured. Linear mixed models and logistic regression were used to determine the effect of APDs on the ECG variables studied. Results: In comparison to sinus beats, APDs were associated with a significant (P < .001) change in P amplitude (−0.03 ± 0.01 mV) and increase in S (0.20 ± 0.02 mV) and T (0.08 ± 0.03 mV) amplitude. PQ (−20.3 ± 5.2 ms) and RR (−519 ± 14 ms) interval and P duration (−21.1 ± 3.0 ms) decreased (P < .001). APDs were significantly associated with a singular positive P wave (OR: 11.0, P < .001) and were more likely to have a monophasic positive T wave (OR: 9.2, P < .001). A smaller RR coupling interval was associated with an increased relative difference in S amplitude (P < .01). Conclusions: Atrial premature depolarizations may lead to changes in QRS and T wave morphology. Knowledge of these changes is important to avoid interpreting certain APDs as VPDs.
- 1 July 2016
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 30 (4) , 1253-1259
Open AccessAtrial Premature Depolarization-Induced Changes in QRS and T Wave Morphology on Resting Electrocardiograms in Horses
Background: The electrocardiographic differentiation between atrial (APDs) and ventricular (VPDs) premature depolarizations is important. P wave prematurity and normal QRS and T wave morphology generally are used as discriminating criteria for APDs. Hypothesis/Objectives: The aim of this study was to determine whether P, Q, R, S, and T wave amplitude, PQ interval, QRS and P wave duration and P and T wave morphology differ between APDs and sinus beats. To determine the relationship between the RR coupling interval and the change in S wave amplitude between sinus beats and APDs. Methods: Case–control study. From a modified base-apex configuration of 30 horses with APDs at rest, sinus beat and APD associated preceding RR interval, P, PQ and QRS duration and P, R, S, and T wave amplitudes were measured. Linear mixed models and logistic regression were used to determine the effect of APDs on the ECG variables studied. Results: In comparison to sinus beats, APDs were associated with a significant (P < .001) change in P amplitude (−0.03 ± 0.01 mV) and increase in S (0.20 ± 0.02 mV) and T (0.08 ± 0.03 mV) amplitude. PQ (−20.3 ± 5.2 ms) and RR (−519 ± 14 ms) interval and P duration (−21.1 ± 3.0 ms) decreased (P < .001). APDs were significantly associated with a singular positive P wave (OR: 11.0, P < .001) and were more likely to have a monophasic positive T wave (OR: 9.2, P < .001). A smaller RR coupling interval was associated with an increased relative difference in S amplitude (P < .01). Conclusions: Atrial premature depolarizations may lead to changes in QRS and T wave morphology. Knowledge of these changes is important to avoid interpreting certain APDs as VPDs.
- 1 April 2016
- Published by Elsevier in The Veterinary Journal
- Vol. 210, 34-38
Assessing aortic regurgitation severity from 2D, M-mode and pulsed wave Doppler echocardiographic measurements in horses
- 1 April 2016
- Published by Elsevier in The Veterinary Journal
- Vol. 210, 34-38
Assessing aortic regurgitation severity from 2D, M-mode and pulsed wave Doppler echocardiographic measurements in horses
- 15 February 2016
- Published by Wiley in Equine Veterinary Journal
- Vol. 49 (1) , 58-64
Echocardiographic measurements of right heart size and function in healthy horses
Summary: Reasons for performing study: Right ventricular ( RV ) function is scarcely described in horses. Objectives: To establish reliable echocardiographic measurements of right heart size and function in horses. Study design: Descriptive study in healthy horses. Methods: Ten healthy untrained adult trotter horses underwent repeated echocardiography performed by 2 sonographers from right and left parasternal standard and nonstandard views. Nonstandard views included a right parasternal view focused on the right atrium, left parasternal long‐axis pulmonary artery view, left parasternal long‐axis view focused on the right ventricle including anatomical M‐mode of tricuspid annular motion and left parasternal pulsed wave Doppler recording of pulmonary flow. During off‐line analysis, 2 observers performed two‐dimensional, M‐mode, pulsed wave Doppler, tissue Doppler imaging ( TDI ) and two‐dimensional speckle tracking (2 DST ) measurements of RV size and function. Acquisition and measurement variability were assessed by calculating coefficients of variation ( CV ) from one‐way repeated measures analyses of variance. The degree of variability was classified as low ( CV 25%). Results: Most two‐dimensional and M‐mode measurements of RV , right atrial and pulmonary artery size showed low variability. The two‐dimensional, M‐mode and pulsed wave Doppler measurements of RV function showed a low to moderate variability. Right ventricular functional measurements by 2 DST showed low variability, except for segmental strain rate. Right ventricular functional measurements by TDI showed a low to high variability, with a lower variability for timing than for peak measurements and a lower variability for velocity compared with deformation measurements. Conclusions: Right heart size and function can be assessed with low variability in horses.
- 15 February 2016
- Published by Wiley in Equine Veterinary Journal
- Vol. 49 (1) , 58-64
Echocardiographic measurements of right heart size and function in healthy horses
Summary: Reasons for performing study: Right ventricular ( RV ) function is scarcely described in horses. Objectives: To establish reliable echocardiographic measurements of right heart size and function in horses. Study design: Descriptive study in healthy horses. Methods: Ten healthy untrained adult trotter horses underwent repeated echocardiography performed by 2 sonographers from right and left parasternal standard and nonstandard views. Nonstandard views included a right parasternal view focused on the right atrium, left parasternal long‐axis pulmonary artery view, left parasternal long‐axis view focused on the right ventricle including anatomical M‐mode of tricuspid annular motion and left parasternal pulsed wave Doppler recording of pulmonary flow. During off‐line analysis, 2 observers performed two‐dimensional, M‐mode, pulsed wave Doppler, tissue Doppler imaging ( TDI ) and two‐dimensional speckle tracking (2 DST ) measurements of RV size and function. Acquisition and measurement variability were assessed by calculating coefficients of variation ( CV ) from one‐way repeated measures analyses of variance. The degree of variability was classified as low ( CV 25%). Results: Most two‐dimensional and M‐mode measurements of RV , right atrial and pulmonary artery size showed low variability. The two‐dimensional, M‐mode and pulsed wave Doppler measurements of RV function showed a low to moderate variability. Right ventricular functional measurements by 2 DST showed low variability, except for segmental strain rate. Right ventricular functional measurements by TDI showed a low to high variability, with a lower variability for timing than for peak measurements and a lower variability for velocity compared with deformation measurements. Conclusions: Right heart size and function can be assessed with low variability in horses.
- 19 December 2015
- Published by Wiley in Veterinary Record
- Vol. 177 (24) , 624
Total plasma proANP increases with atrial dilatation in horses
Equine atrial natriuretic peptide (ANP) plasma concentrations are correlated with left atrial size. However, species‐specific assays are lacking and the results from human assays are poorly reproducible. A new methodology called processing independent analysis (PIA) that measures the total proANP product in plasma has proven to be successful in human medicine, but has never been used in horses. The aims were to establish an equine proANP reference interval by measurement of the total proANP product using PIA and to examine the proANP concentrations in horses with atrial dilatation. Sample stability was studied by comparison of storage at −80°C and −20°C. Plasma samples were obtained from 23 healthy horses, 12 horses with moderate or severe valvular regurgitation without atrial dilatation and 42 horses with valvular regurgitation and atrial dilatation. The proANP concentration was significantly (P<0.001) higher in horses with atrial dilatation (761.4 (442.1–1859.1) pmol/l) than in healthy horses (491.6 (429.5–765.9) pmol/l; P<0.001) or horses with cardiac disease but without atrial dilatation (544.4 (457.0–677.6) pmol/l). A cut‐off value (573.8 pmol/l) for detection of atrial dilatation was calculated. Sample storage at −80°C did not differ from sample storage at −20°C. The measurement of total proANP in plasma detects atrial dilatation in horses and may be useful for clinical evaluation in equine medicine.
- 19 December 2015
- Published by Wiley in Veterinary Record
- Vol. 177 (24) , 624
Total plasma proANP increases with atrial dilatation in horses
Equine atrial natriuretic peptide (ANP) plasma concentrations are correlated with left atrial size. However, species‐specific assays are lacking and the results from human assays are poorly reproducible. A new methodology called processing independent analysis (PIA) that measures the total proANP product in plasma has proven to be successful in human medicine, but has never been used in horses. The aims were to establish an equine proANP reference interval by measurement of the total proANP product using PIA and to examine the proANP concentrations in horses with atrial dilatation. Sample stability was studied by comparison of storage at −80°C and −20°C. Plasma samples were obtained from 23 healthy horses, 12 horses with moderate or severe valvular regurgitation without atrial dilatation and 42 horses with valvular regurgitation and atrial dilatation. The proANP concentration was significantly (P<0.001) higher in horses with atrial dilatation (761.4 (442.1–1859.1) pmol/l) than in healthy horses (491.6 (429.5–765.9) pmol/l; P<0.001) or horses with cardiac disease but without atrial dilatation (544.4 (457.0–677.6) pmol/l). A cut‐off value (573.8 pmol/l) for detection of atrial dilatation was calculated. Sample storage at −80°C did not differ from sample storage at −20°C. The measurement of total proANP in plasma detects atrial dilatation in horses and may be useful for clinical evaluation in equine medicine.
- 16 July 2015
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 27 (4) , 504-509
Analytical validation of a high-sensitivity cardiac troponin T assay in horses
Although cardiac troponin T (cTnT) assays have been used to detect myocardial damage in horses, a cTnT assay has not been analytically validated, to our knowledge. The aims of this study were to estimate the precision of a high-sensitivity cTnT assay in horses and determine the effect of hemolysis on the measured cTnT concentration. Serum samples from horses were mixed in 3 different pools. Pool 1 consisted of samples from 3 healthy horses, pool 2 from 6 horses with heart failure or atypical myopathy, and pool 3 from 10 horses with atypical myopathy. The within- and between-run coefficients of variation were determined for each pool. Pools 2 and 3 were diluted to estimate linearity. To study the influence of sample hemolysis, serum was collected from 4 horses with a high cTnT concentration, in which hemolysis was mechanically induced. In addition, ethylenediamine tetra-acetic acid blood tubes were collected from 3 other horses, from which hemolysate was prepared and added to plasma at different concentrations. The within- and between-run coefficients of variation of all pools were <10%, and a good linearity was found. Three out of 4 hemolyzed serum samples had a decreased serum cTnT concentration. Plasma samples with a high hemolysis index showed a negative interference, resulting in a lower cTnT concentration. Results of the high-sensitivity cTnT assay were highly reproducible. Because samples from horses with musculoskeletal damage were included, further studies should test the possible cross-reactivity between troponin T of musculoskeletal and cardiac origin before the assay can be used in equine clinical practice.
- 16 July 2015
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 27 (4) , 504-509
Analytical validation of a high-sensitivity cardiac troponin T assay in horses
Although cardiac troponin T (cTnT) assays have been used to detect myocardial damage in horses, a cTnT assay has not been analytically validated, to our knowledge. The aims of this study were to estimate the precision of a high-sensitivity cTnT assay in horses and determine the effect of hemolysis on the measured cTnT concentration. Serum samples from horses were mixed in 3 different pools. Pool 1 consisted of samples from 3 healthy horses, pool 2 from 6 horses with heart failure or atypical myopathy, and pool 3 from 10 horses with atypical myopathy. The within- and between-run coefficients of variation were determined for each pool. Pools 2 and 3 were diluted to estimate linearity. To study the influence of sample hemolysis, serum was collected from 4 horses with a high cTnT concentration, in which hemolysis was mechanically induced. In addition, ethylenediamine tetra-acetic acid blood tubes were collected from 3 other horses, from which hemolysate was prepared and added to plasma at different concentrations. The within- and between-run coefficients of variation of all pools were <10%, and a good linearity was found. Three out of 4 hemolyzed serum samples had a decreased serum cTnT concentration. Plasma samples with a high hemolysis index showed a negative interference, resulting in a lower cTnT concentration. Results of the high-sensitivity cTnT assay were highly reproducible. Because samples from horses with musculoskeletal damage were included, further studies should test the possible cross-reactivity between troponin T of musculoskeletal and cardiac origin before the assay can be used in equine clinical practice.
- Open Access
Veal Calves Produce Less Antibodies against C. Perfringens Alpha Toxin Compared to Beef Calves
Enterotoxaemia is a disease with a high associated mortality rate, affecting beef and veal calves worldwide, caused by C. perfringens alpha toxin and perfringolysin. A longitudinal study was conducted to determine the dynamics of antibodies against these toxins in 528 calves on 4 beef and 15 veal farms. The second study aimed to determine the effect of solid feed intake on the production of antibodies against alpha toxin and perfringolysin. The control group only received milk replacer, whereas in the test group solid feed was provided. Maternal antibodies for alpha toxin were present in 45% of the veal calves and 66% of the beef calves. In beef calves a fluent transition from maternal to active immunity was observed for alpha toxin, whereas almost no veal calves developed active immunity. Perfringolysin antibodies significantly declined both in veal and beef calves. In the second study all calves were seropositive for alpha toxin throughout the experiment and solid feed intake did not alter the dynamics of alpha and perfringolysin antibodies. In conclusion, the present study showed that veal calves on a traditional milk replacer diet had significantly lower alpha toxin antibodies compared to beef calves in the risk period for enterotoxaemia, whereas no differences were noticed for perfringolysin.
Open AccessVeal Calves Produce Less Antibodies against C. Perfringens Alpha Toxin Compared to Beef Calves
Enterotoxaemia is a disease with a high associated mortality rate, affecting beef and veal calves worldwide, caused by C. perfringens alpha toxin and perfringolysin. A longitudinal study was conducted to determine the dynamics of antibodies against these toxins in 528 calves on 4 beef and 15 veal farms. The second study aimed to determine the effect of solid feed intake on the production of antibodies against alpha toxin and perfringolysin. The control group only received milk replacer, whereas in the test group solid feed was provided. Maternal antibodies for alpha toxin were present in 45% of the veal calves and 66% of the beef calves. In beef calves a fluent transition from maternal to active immunity was observed for alpha toxin, whereas almost no veal calves developed active immunity. Perfringolysin antibodies significantly declined both in veal and beef calves. In the second study all calves were seropositive for alpha toxin throughout the experiment and solid feed intake did not alter the dynamics of alpha and perfringolysin antibodies. In conclusion, the present study showed that veal calves on a traditional milk replacer diet had significantly lower alpha toxin antibodies compared to beef calves in the risk period for enterotoxaemia, whereas no differences were noticed for perfringolysin.
- Open Access
- 1 May 2015
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 29 (3) , 946-953
Risk Factors for Recurrence of Atrial Fibrillation in Horses After Cardioversion to Sinus Rhythm
Background: Although atrial fibrillation (AF) can be successfully treated in horses, recurrence occurs frequently. In humans, atrial function after cardioversion can predict recurrence. Objectives: To examine the prognostic value of atrial mechanical function at 24 hours after cardioversion and other potential predictor variables for AF recurrence in horses. Animals: 117 horses treated for AF at 4 referral centers. Methods: Retrospective study. Inclusion criteria were successful cardioversion, echocardiography at 24 hours after cardioversion and ≥4 months follow-up. To determine factors associated with AF recurrence, a multivariable survival model was built. Results: 133 AF episodes in 117 horses were included. AF recurred in 36/100 horses with a first AF episode and in 57/133 AF episodes overall. Factors associated with recurrence in horses with a first episode were previous unsuccessful treatment attempt (hazard ratio HR 2.36, 95% confidence interval CI 1.11–4.99, P = .025) and mild or moderate mitral regurgitation (HR 2.70, 95% CI 1.23–5.91, P = .013). When the last AF episode of all horses was included, previous AF (HR 2.53, 1.33–4.82, P = .005) and active left atrial fractional area change ≤9.6% (HR 3.43, 1.22–9.67, P = .020) were significant predictors. Conclusions and Clinical Importance: The only echocardiographic variable of left atrial function with significant prognostic value for recurrence was low active left atrial fractional area change. Further research is necessary to evaluate whether echocardiography at a later timepoint could provide more prognostic information.
- 1 May 2015
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 29 (3) , 946-953
Open AccessRisk Factors for Recurrence of Atrial Fibrillation in Horses After Cardioversion to Sinus Rhythm
Background: Although atrial fibrillation (AF) can be successfully treated in horses, recurrence occurs frequently. In humans, atrial function after cardioversion can predict recurrence. Objectives: To examine the prognostic value of atrial mechanical function at 24 hours after cardioversion and other potential predictor variables for AF recurrence in horses. Animals: 117 horses treated for AF at 4 referral centers. Methods: Retrospective study. Inclusion criteria were successful cardioversion, echocardiography at 24 hours after cardioversion and ≥4 months follow-up. To determine factors associated with AF recurrence, a multivariable survival model was built. Results: 133 AF episodes in 117 horses were included. AF recurred in 36/100 horses with a first AF episode and in 57/133 AF episodes overall. Factors associated with recurrence in horses with a first episode were previous unsuccessful treatment attempt (hazard ratio HR 2.36, 95% confidence interval CI 1.11–4.99, P = .025) and mild or moderate mitral regurgitation (HR 2.70, 95% CI 1.23–5.91, P = .013). When the last AF episode of all horses was included, previous AF (HR 2.53, 1.33–4.82, P = .005) and active left atrial fractional area change ≤9.6% (HR 3.43, 1.22–9.67, P = .020) were significant predictors. Conclusions and Clinical Importance: The only echocardiographic variable of left atrial function with significant prognostic value for recurrence was low active left atrial fractional area change. Further research is necessary to evaluate whether echocardiography at a later timepoint could provide more prognostic information.