Ana Jiménez-Ballvé
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ana Jiménez-Ballvé has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
J.L. Carreras-Delgado
Servicio de Medicina Nuclear, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria Hospital Clínico San Carlos, Madrid, España
4 shared publicationsA. Serrano-Palacio
Servicio de Medicina Nuclear, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria Hospital Clínico San Carlos, Madrid, España
3 shared publicationsA. Ortega Candil
Servicio de Medicina Nuclear, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria Hospital Clínico San Carlos, Madrid, España
2 shared publicationsJ.M. Román-Santamaría
Servicio de Ginecología y Obstetricia, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria Hospital Clínico San Carlos, Madrid, España
2 shared publications- Jose Angel Garcia Saenz
GEICAM, Spanish Breast Cancer Group, Madrid, Spain
2 shared publications L.F. León-Ramírez
Nuclear Medicine Department, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria Hospital Clínico San Carlos, Madrid, Spain
2 shared publications
Latest Publications
- Open Access
- 1 July 2017
- Published by Elsevier in Cirugía Cardiovascular
- Vol. 24 (4) , 228-235
Avances en el diagnóstico por imagen de la endocarditis infecciosa izquierda
- 1 July 2017
- Published by Elsevier in Cirugía Cardiovascular
- Vol. 24 (4) , 228-235
Open AccessAvances en el diagnóstico por imagen de la endocarditis infecciosa izquierda
- 5 September 2016
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 43 (13) , 2401-2412
Assessment of the diagnostic accuracy of 18F-FDG PET/CT in prosthetic infective endocarditis and cardiac implantable electronic device infection: comparison of different interpretation criteria
Purpose The diagnosis of prosthetic valve (PV) infective endocarditis (IE) and infection of cardiac implantable electronic devices (CIEDs) remains challenging. The aim of this study was to assess the usefulness of 18F-FDG PET/CT in these patients and analyse the interpretation criteria. Methods We included 41 patients suspected of having IE by the Duke criteria who underwent 18F-FDG PET/CT. The criteria applied for classifying the findings as positive/negative for IE were: (a) visual analysis of only PET images with attenuation-correction (AC PET images); (b) visual analysis of both AC PET images and PET images without AC (NAC PET images); (c) qualitative analysis of NAC PET images; and (d) semiquantitative analysis of AC PET images. 18F-FDG PET/CT was considered positive for IE independently of the intensity and distribution of FDG uptake. The gold standard was the Duke pathological criteria (if tissue was available) or the decision of an endocarditis expert team after a minimum 4 months follow-up. Results We studied 62 areas with suspicion of IE, 28 areas (45 %) showing definite IE and 34 (55 %) showing possible IE. Visual analysis of only AC PET images showed poor diagnostic accuracy (sensitivity 20 %, specificity 57 %). Visual analysis of both AC PET and NAC PET images showed excellent sensitivity (100 %) and intermediate specificity (73 %), focal uptake being more frequently associated with IE. The accuracy of qualitative analysis of NAC PET images depended on the threshold: the maximum sensitivity, specificity and accuracy achieved were 88 %, 80 %, 84 %, respectively. In the semiquantitative analysis of AC PET images, SUVmax was higher in areas of confirmed IE than in those without IE (∆SUVmax 2.2, p < 0.001). When FDG uptake was twice that in the liver, IE was always confirmed, and SUVmax 5.5 was the optimal threshold for IE diagnosis using ROC curve analysis (area under the curve 0.71). Conclusion The value of 18F-FDG PET/CT in the diagnosis of suspected IE of PVs and CIEDs is highly dependent on patient preparation and the method used for image interpretation. Based on our results, the best method is to consider a study positive for IE when FDG uptake is present in both AC PET and NAC PET images.
- 5 September 2016
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 43 (13) , 2401-2412
Assessment of the diagnostic accuracy of 18F-FDG PET/CT in prosthetic infective endocarditis and cardiac implantable electronic device infection: comparison of different interpretation criteria
Purpose The diagnosis of prosthetic valve (PV) infective endocarditis (IE) and infection of cardiac implantable electronic devices (CIEDs) remains challenging. The aim of this study was to assess the usefulness of 18F-FDG PET/CT in these patients and analyse the interpretation criteria. Methods We included 41 patients suspected of having IE by the Duke criteria who underwent 18F-FDG PET/CT. The criteria applied for classifying the findings as positive/negative for IE were: (a) visual analysis of only PET images with attenuation-correction (AC PET images); (b) visual analysis of both AC PET images and PET images without AC (NAC PET images); (c) qualitative analysis of NAC PET images; and (d) semiquantitative analysis of AC PET images. 18F-FDG PET/CT was considered positive for IE independently of the intensity and distribution of FDG uptake. The gold standard was the Duke pathological criteria (if tissue was available) or the decision of an endocarditis expert team after a minimum 4 months follow-up. Results We studied 62 areas with suspicion of IE, 28 areas (45 %) showing definite IE and 34 (55 %) showing possible IE. Visual analysis of only AC PET images showed poor diagnostic accuracy (sensitivity 20 %, specificity 57 %). Visual analysis of both AC PET and NAC PET images showed excellent sensitivity (100 %) and intermediate specificity (73 %), focal uptake being more frequently associated with IE. The accuracy of qualitative analysis of NAC PET images depended on the threshold: the maximum sensitivity, specificity and accuracy achieved were 88 %, 80 %, 84 %, respectively. In the semiquantitative analysis of AC PET images, SUVmax was higher in areas of confirmed IE than in those without IE (∆SUVmax 2.2, p < 0.001). When FDG uptake was twice that in the liver, IE was always confirmed, and SUVmax 5.5 was the optimal threshold for IE diagnosis using ROC curve analysis (area under the curve 0.71). Conclusion The value of 18F-FDG PET/CT in the diagnosis of suspected IE of PVs and CIEDs is highly dependent on patient preparation and the method used for image interpretation. Based on our results, the best method is to consider a study positive for IE when FDG uptake is present in both AC PET and NAC PET images.
- 1 May 2015
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular
- Vol. 34 (3) , 207-208
Diagnosis of infection in a patient with implantable device with 18F-FDG PET-CT
- 1 May 2015
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular
- Vol. 34 (3) , 207-208
Diagnosis of infection in a patient with implantable device with 18F-FDG PET-CT
- 3 March 2015
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular
- Vol. 34 (4) , 230-235
Respuesta patológica en la axila tras quimioterapia neoadyuvante en el cáncer de mama localmente avanzado con afectación axilar
- 3 March 2015
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular
- Vol. 34 (4) , 230-235
Respuesta patológica en la axila tras quimioterapia neoadyuvante en el cáncer de mama localmente avanzado con afectación axilar
- 1 March 2015
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular
- Vol. 34 (2) , 130-132
Nasal cerebrospinal fluid leakage diagnosed by cisternoscintigraphy with intestinal activity confirmed by SPECT-CT
- 1 March 2015
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular
- Vol. 34 (2) , 130-132
Nasal cerebrospinal fluid leakage diagnosed by cisternoscintigraphy with intestinal activity confirmed by SPECT-CT