Ahmet Ozgur Saf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ahmet Ozgur Saf has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Haluk Bingol
Science and Technology Research and Application Center (BITAM), Necmettin Erbakan University, Konya, Türkiye; Department of Basic Sciences, Faculty of Engineering, Necmettin Erbakan University, Konya, Türkiye
3 shared publications - Erhan Zor
Science and Technology Research and Application Center (BİTAM), Necmettin Erbakan University, Konya, Turkiye
2 shared publications - Ilker Akin
Necmettin Erbakan Universitesi
2 shared publications - Emine Guler Akgemci
Selcuk Univ, Dept Chem, TR-42099 Meram Konya, Turkey
1 shared publication - Ercan Türkkan
Department of Physic Education, Faculty of A.K. Education, University of Necmettin Erbakan, Konya, Turkey
1 shared publication - Halil Ugur Tasdemir
Necmettin Erbakan University, Turkey
1 shared publication
Latest Publications
- 28 April 2015
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 5 (53) , 42422-42429
Preparation of a novel PSf membrane containing rGO/PTh and its physical properties and membrane performance
Recent advances in the fabrication of nanostructures such as graphene-related materials have received a lot of attention in membrane technology for the future of water supplies. Herein, we report the synthesis of a reduced graphene oxide/polythiophene (rGO/PTh) composite material using an in situ enzymatic polymerization reaction, which is an eco-friendly and a simple way to construct a nanocomposite material. Polysulfone (PSf) mixed matrix composite membranes containing rGO and rGO/PTh were prepared via a phase inversion method. The morphology of the membranes was evaluated by various characterization methods, including SEM, AFM, contact angle and porosity measurements. The performance and antifouling properties of the membranes were examined in detail. The PSf-rGO/PTh membrane showed a significant improvement in water flux permeability due to the enhancement of hydrophilicity and porosity. Moreover, the PSf-rGO/PTh membrane exhibited an approximately 10 times higher improved water flux than that of the rGO membrane as the pressure was increased. The fouling resistance ratio (FRR) and antifouling properties of the membranes were tested using two different protein solutions: bovine serum albumin (BSA) and cytochrome c (Ctc). The antifouling and FRR properties of the PSf-rGO/PTh membrane decreased due to not only the interactions between the functional groups on the membrane surface and fouling materials, but also the morphological properties of the membrane.
- 28 April 2015
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 5 (53) , 42422-42429
Preparation of a novel PSf membrane containing rGO/PTh and its physical properties and membrane performance
Recent advances in the fabrication of nanostructures such as graphene-related materials have received a lot of attention in membrane technology for the future of water supplies. Herein, we report the synthesis of a reduced graphene oxide/polythiophene (rGO/PTh) composite material using an in situ enzymatic polymerization reaction, which is an eco-friendly and a simple way to construct a nanocomposite material. Polysulfone (PSf) mixed matrix composite membranes containing rGO and rGO/PTh were prepared via a phase inversion method. The morphology of the membranes was evaluated by various characterization methods, including SEM, AFM, contact angle and porosity measurements. The performance and antifouling properties of the membranes were examined in detail. The PSf-rGO/PTh membrane showed a significant improvement in water flux permeability due to the enhancement of hydrophilicity and porosity. Moreover, the PSf-rGO/PTh membrane exhibited an approximately 10 times higher improved water flux than that of the rGO membrane as the pressure was increased. The fouling resistance ratio (FRR) and antifouling properties of the membranes were tested using two different protein solutions: bovine serum albumin (BSA) and cytochrome c (Ctc). The antifouling and FRR properties of the PSf-rGO/PTh membrane decreased due to not only the interactions between the functional groups on the membrane surface and fouling materials, but also the morphological properties of the membrane.
- 1 February 2015
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 136, 719-725
Spectrophotometric, voltammetric and cytotoxicity studies of 2-hydroxy-5-methoxyacetophenone thiosemicarbazone and its N(4)-substituted derivatives: A combined experimental–computational study
- 1 February 2015
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 136, 719-725
Spectrophotometric, voltammetric and cytotoxicity studies of 2-hydroxy-5-methoxyacetophenone thiosemicarbazone and its N(4)-substituted derivatives: A combined experimental–computational study
- 19 February 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (24) , 12457-12466
Green synthesis of reduced graphene oxide/nanopolypyrrole composite: characterization and H2O2 determination in urine
Here we report on a novel, simple and eco-friendly approach for the fabrication of a reduced Graphene Oxide/nanopolypyrrole (rGO/nPPy) composite material and its electrochemical performance for detection of hydrogen peroxide on a glassy carbon electrode. The characterization of the as-prepared rGO/nPPy composite was investigated by Fourier transform infrared spectroscopy, thermogravimetric analysis, ultraviolet-visible spectroscopy, scanning electron microscopy, contact angle measurement, cyclic voltammetry and electrochemical impedance spectroscopy. Cyclic voltammetry, differential pulse voltammetry and chronoamperometry techniques were used to investigate and optimize the performance of the developed electrochemical biosensor. The proposed biosensor showed excellent analytical response towards the quantification of H2O2 at pH 7.40. Under the optimized conditions, the biosensor shows a linear response range from 1.0 × 10−7 to 4.0 × 10−6 M concentrations of H2O2. The limit of detection was determined to be 34 nM. Reproducibility, sensitivity, stability and anti-interference capability of the fabricated biosensor for the detection of H2O2 were examined. The biological relevance of the developed electrochemical biosensor was further studied by the determination of H2O2 in urine samples. The real sample analysis of H2O2 was achieved before and after drinking coffee in urine samples. The successful and sensitive determination of H2O2 urine samples indicates that the proposed electrochemical biosensor can be applied to the quantification analysis of H2O2 in real samples.
- 19 February 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (24) , 12457-12466
Green synthesis of reduced graphene oxide/nanopolypyrrole composite: characterization and H2O2 determination in urine
Here we report on a novel, simple and eco-friendly approach for the fabrication of a reduced Graphene Oxide/nanopolypyrrole (rGO/nPPy) composite material and its electrochemical performance for detection of hydrogen peroxide on a glassy carbon electrode. The characterization of the as-prepared rGO/nPPy composite was investigated by Fourier transform infrared spectroscopy, thermogravimetric analysis, ultraviolet-visible spectroscopy, scanning electron microscopy, contact angle measurement, cyclic voltammetry and electrochemical impedance spectroscopy. Cyclic voltammetry, differential pulse voltammetry and chronoamperometry techniques were used to investigate and optimize the performance of the developed electrochemical biosensor. The proposed biosensor showed excellent analytical response towards the quantification of H2O2 at pH 7.40. Under the optimized conditions, the biosensor shows a linear response range from 1.0 × 10−7 to 4.0 × 10−6 M concentrations of H2O2. The limit of detection was determined to be 34 nM. Reproducibility, sensitivity, stability and anti-interference capability of the fabricated biosensor for the detection of H2O2 were examined. The biological relevance of the developed electrochemical biosensor was further studied by the determination of H2O2 in urine samples. The real sample analysis of H2O2 was achieved before and after drinking coffee in urine samples. The successful and sensitive determination of H2O2 urine samples indicates that the proposed electrochemical biosensor can be applied to the quantification analysis of H2O2 in real samples.