Georgia Tsoumakidou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Georgia Tsoumakidou has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Afshin Gangi
Department of Interventional Radiology, University Hospital Strasbourg, Strasbourg, France
11 shared publications - Guillaume Koch
Department of Interventional Radiology, University Hospital Strasbourg, Strasbourg, France
9 shared publications - Nitin Ramamurthy
Department of Radiology, Norfolk and Norwich University Hospital, Norwich, UK
7 shared publications - Roberto Luigi Cazzato
Department of Interventional Radiology, University Hospital Strasbourg, Strasbourg, France
7 shared publications - Julien Garnon
Department of Interventional Radiology, University Hospital of Strasbourg, Strasbourg, France
6 shared publications - Pramod Rao
ICube, University of Strasbourg, Strasbourg, France
5 shared publications
Latest Publications
- 29 March 2017
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 40 (8) , 1267-1273
Ultrasound-Guided Biopsies of Bone Lesions Without Cortical Disruption Using Fusion Imaging and Needle Tracking: Proof of Concept
- 29 March 2017
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 40 (8) , 1267-1273
Ultrasound-Guided Biopsies of Bone Lesions Without Cortical Disruption Using Fusion Imaging and Needle Tracking: Proof of Concept
- 21 June 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (10) , 1521-1524
Curved Needles: Beyond Diagnostic Procedures
- 21 June 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (10) , 1521-1524
Curved Needles: Beyond Diagnostic Procedures
- 2 June 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (10) , 1455-1463
Percutaneous Image-Guided Screw Fixation of Bone Lesions in Cancer Patients: Double-Centre Analysis of Outcomes including Local Evolution of the Treated Focus
Aim To review outcomes and local evolution of treated lesions following percutaneous image-guided screw fixation (PIGSF) of pathological/insufficiency fractures (PF/InF) and impeding fractures (ImF) in cancer patients at two tertiary centres. Materials and methods Thirty-two consecutive patients (mean age 67.5 years; range 33–86 years) with a range of tumours and prognoses underwent PIGSF for non/minimally displaced PF/InF and ImF. Screws were placed under CT/fluoroscopy or cone-beam CT guidance, with or without cementoplasty. Clinical outcomes were assessed using a simple 4-point scale (1 = worse; 2 = stable; 3 = improved; 4 = significantly improved). Local evolution was reviewed on most recent follow-up imaging. Technical success, complications, and overall survival were evaluated. Results Thirty-six lesions were treated with 74 screws mainly in the pelvis and femoral neck (58.2 %); including 47.2 % PF, 13.9 % InF, and 38.9 % ImF. Cementoplasty was performed in 63.9 % of the cases. Technical success was 91.6 %. Hospital stay was ≤3 days; 87.1 % of lesions were improved at 1-month follow-up; three major complications (early screw-impingement radiculopathy; accelerated coxarthrosis; late coxofemoral septic arthritis) and one minor complication were observed. Unfavourable local evolution at imaging occurred in 3/24 lesions (12.5 %) at mean 8.7-month follow-up, including poor consolidation (one case) and screw loosening (two cases, at least 1 symptomatic). There were no cases of secondary fractures. Conclusions PIGSF is feasible for a wide range of oncologic patients, offering good short-term efficacy, acceptable complication rates, and rapid recovery. Unfavourable local evolution at imaging may be relatively frequent, and requires close clinico-radiological surveillance.
- 2 June 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (10) , 1455-1463
Percutaneous Image-Guided Screw Fixation of Bone Lesions in Cancer Patients: Double-Centre Analysis of Outcomes including Local Evolution of the Treated Focus
Aim To review outcomes and local evolution of treated lesions following percutaneous image-guided screw fixation (PIGSF) of pathological/insufficiency fractures (PF/InF) and impeding fractures (ImF) in cancer patients at two tertiary centres. Materials and methods Thirty-two consecutive patients (mean age 67.5 years; range 33–86 years) with a range of tumours and prognoses underwent PIGSF for non/minimally displaced PF/InF and ImF. Screws were placed under CT/fluoroscopy or cone-beam CT guidance, with or without cementoplasty. Clinical outcomes were assessed using a simple 4-point scale (1 = worse; 2 = stable; 3 = improved; 4 = significantly improved). Local evolution was reviewed on most recent follow-up imaging. Technical success, complications, and overall survival were evaluated. Results Thirty-six lesions were treated with 74 screws mainly in the pelvis and femoral neck (58.2 %); including 47.2 % PF, 13.9 % InF, and 38.9 % ImF. Cementoplasty was performed in 63.9 % of the cases. Technical success was 91.6 %. Hospital stay was ≤3 days; 87.1 % of lesions were improved at 1-month follow-up; three major complications (early screw-impingement radiculopathy; accelerated coxarthrosis; late coxofemoral septic arthritis) and one minor complication were observed. Unfavourable local evolution at imaging occurred in 3/24 lesions (12.5 %) at mean 8.7-month follow-up, including poor consolidation (one case) and screw loosening (two cases, at least 1 symptomatic). There were no cases of secondary fractures. Conclusions PIGSF is feasible for a wide range of oncologic patients, offering good short-term efficacy, acceptable complication rates, and rapid recovery. Unfavourable local evolution at imaging may be relatively frequent, and requires close clinico-radiological surveillance.
- 5 April 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (9) , 1332-1338
Percutaneous CT and Fluoroscopy-Guided Screw Fixation of Pathological Fractures in the Shoulder Girdle: Technical Report of 3 Cases
To review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures. Between May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment. Four pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality. Percutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.
- 5 April 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (9) , 1332-1338
Percutaneous CT and Fluoroscopy-Guided Screw Fixation of Pathological Fractures in the Shoulder Girdle: Technical Report of 3 Cases
To review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures. Between May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment. Four pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality. Percutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.
- 5 April 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (9) , 1315-1321
18F-FDOPA PET/CT-Guided Radiofrequency Ablation of Liver Metastases from Neuroendocrine Tumours: Technical Note on a Preliminary Experience
To review our preliminary experience with 6-l-18F-fluorodihydroxyphenylalanine (18F-FDOPA) PET/CT-guided radiofrequency ablation (RFA) of liver metastases from neuroendocrine tumours (NETs). Three patients (mean age 51.3 years; range 43–56) with gastro-entero pancreatic NET (GEP-NET) liver metastases underwent 18F-FDOPA PET/CT-guided RFA. Patients were referred with oligometastatic hepatic-confined disease (1–6 metastases; n = 2) in resolving carcinoid syndrome symptoms. 18F-FDOPA PET/CT-guided RFA appears technically feasible, safe, and effective in patients with GEP-NETs and low-burden hepatic metastases. Further prospective studies are required to elucidate its precise role in tailored multimodality management of GEP-NET liver metastases.
- 5 April 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (9) , 1315-1321
18F-FDOPA PET/CT-Guided Radiofrequency Ablation of Liver Metastases from Neuroendocrine Tumours: Technical Note on a Preliminary Experience
To review our preliminary experience with 6-l-18F-fluorodihydroxyphenylalanine (18F-FDOPA) PET/CT-guided radiofrequency ablation (RFA) of liver metastases from neuroendocrine tumours (NETs). Three patients (mean age 51.3 years; range 43–56) with gastro-entero pancreatic NET (GEP-NET) liver metastases underwent 18F-FDOPA PET/CT-guided RFA. Patients were referred with oligometastatic hepatic-confined disease (1–6 metastases; n = 2) in resolving carcinoid syndrome symptoms. 18F-FDOPA PET/CT-guided RFA appears technically feasible, safe, and effective in patients with GEP-NETs and low-burden hepatic metastases. Further prospective studies are required to elucidate its precise role in tailored multimodality management of GEP-NET liver metastases.
- 16 February 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (7) , 1050-1056
Percutaneous Management of Accidentally Retained Foreign Bodies During Image-Guided Non-vascular Procedures: Novel Technique Using a Large-Bore Biopsy System
Objective To describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures. Materials and Methods Between May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioning a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications. Results Mean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications. Conclusion Percutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.
- 16 February 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (7) , 1050-1056
Percutaneous Management of Accidentally Retained Foreign Bodies During Image-Guided Non-vascular Procedures: Novel Technique Using a Large-Bore Biopsy System
Objective To describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures. Materials and Methods Between May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioning a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications. Results Mean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications. Conclusion Percutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.
- 27 January 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (5) , 791-794
Optimising Pulmonary Microwave Ablation Using Trans-Scapular Access and Continuous Temperature Monitoring
- 27 January 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (5) , 791-794
Optimising Pulmonary Microwave Ablation Using Trans-Scapular Access and Continuous Temperature Monitoring
- 24 November 2015
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (2) , 315-317
Cryoablation Does Not Prevent from Diaphragmatic Hernia
- 24 November 2015
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (2) , 315-317
Cryoablation Does Not Prevent from Diaphragmatic Hernia
- 1 August 2015
- Published by Oxford University Press (OUP)
- p. 239-244
Vertebroplasty of the cervical spine
A case of cervical level primary aneurysmal bone cyst treated percutaneously with vertebroplasty is discussed. The patient presented with local pain due to vertebral body fracture with no signs of radiculopathy or neurological deficit. The procedure was performed under general anaesthesia and combined CT-fluoroscopic guidance. An anterior approach was used with the needle trajectory between the carotid sheath laterally, and the thyroid gland and oesophagus medially. The patient was symptom free immediately after the procedure. The short- and long-term clinical and imaging follow-up was satisfactory
- 1 August 2015
- Published by Oxford University Press (OUP)
- p. 239-244
Vertebroplasty of the cervical spine
A case of cervical level primary aneurysmal bone cyst treated percutaneously with vertebroplasty is discussed. The patient presented with local pain due to vertebral body fracture with no signs of radiculopathy or neurological deficit. The procedure was performed under general anaesthesia and combined CT-fluoroscopic guidance. An anterior approach was used with the needle trajectory between the carotid sheath laterally, and the thyroid gland and oesophagus medially. The patient was symptom free immediately after the procedure. The short- and long-term clinical and imaging follow-up was satisfactory