Carmen P. Lydell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carmen P. Lydell has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- James A. White
Stephenson Cardiac Imaging Centre, University of Calgary, Calgary, AB T2N 1N4, Canada
5 shared publications - Andrew G. Howarth
Department of Cardiac Sciences, Cumming School of Medicine, Libin Cardiovascular Institute, University of Calgary, Alberta, Canada. (W.H., L.J., A.H., R.K., J.S., W.K., R.J.H.M.)
4 shared publications - Alessandro Satriano
Stephenson Cardiac Imaging Centre, Calgary, Canada
3 shared publications - Naeem Merchant
Department of Diagnostic Imaging, University of Calgary, Calgary, AB, Canada
3 shared publications - Nowell M. Fine
Libin Cardiovascular Institute, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
3 shared publications - Bobak Heydari
Center for Cardiovascular Innovation, Division of Cardiology, Department of Medicine, University of British Columbia, 2775 Laurel St, 9th Floor, Vancouver, BC V5Z 1M9, Canada
2 shared publications
Latest Publications
- 4 August 2018
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 35 (1) , 121-131
Intra-thoracic adiposity is associated with impaired contractile function in patients with coronary artery disease: a cardiovascular magnetic resonance imaging study
The influence of visceral adiposity on left ventricular remodeling following coronary artery disease (CAD)-related events has not been examined to date. Using magnetic resonance imaging (MRI) we explored intra-thoracic fat volume (ITFV) and strain-based markers of adverse remodeling in patients with CAD. Forty-seven patients with known CAD (25 with prior MI, 22 without prior MI) were studied. ITFV was quantified using previously validated imaging techniques. Myocardial strain was derived from cine MRI using a validated 3D feature-tracking (FT) software. Segmental LGE quantification was performed and was used to incrementally constrain strain analyses to non-infarcted (i.e. remote) segments. Remote myocardial strain was compared to the non-MI control cohort and was explored for associations with ITFV. Mean age was 57 ± 13 years with a mean BMI of 30.0 ± 6.2 kg/m2 (range 20.3–38.4 kg/m2). Patients with versus without prior MI had similar demographics and BMI (29.4 ± 4.4 vs. 30.4 ± 7.9 kg/m2, p = 0.62). Patients with prior MI had lower mean peak strain than non-MI patients (p = 0.02), consistent with remote tissue contractile dysfunction. Inverse associations were identified between ITFV and mean peak strain in both the MI group (circumferential: r = 0.43, p = 0.03; radial: − 0.41, p = 0.04; minimum principal: r = 0.41, p = 0.04; maximum principal: r = − 0.43, p = 0.03) and non-MI group (circumferential: r = 0.42, p = 0.05; minimum principal: r = 0.45, p = 0.03). In those with prior MI higher ITFV was associated with a greater reduction in remote tissue strain. ITFV is associated with contractile dysfunction in patients with CAD. This association is prominent in the post-MI setting suggesting relevant influence on remote tissue health following ischemic injury. Expanded study of intra-thoracic adiposity as a modulator of myocardial health in patients with CAD is warranted.
- 4 August 2018
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 35 (1) , 121-131
Intra-thoracic adiposity is associated with impaired contractile function in patients with coronary artery disease: a cardiovascular magnetic resonance imaging study
The influence of visceral adiposity on left ventricular remodeling following coronary artery disease (CAD)-related events has not been examined to date. Using magnetic resonance imaging (MRI) we explored intra-thoracic fat volume (ITFV) and strain-based markers of adverse remodeling in patients with CAD. Forty-seven patients with known CAD (25 with prior MI, 22 without prior MI) were studied. ITFV was quantified using previously validated imaging techniques. Myocardial strain was derived from cine MRI using a validated 3D feature-tracking (FT) software. Segmental LGE quantification was performed and was used to incrementally constrain strain analyses to non-infarcted (i.e. remote) segments. Remote myocardial strain was compared to the non-MI control cohort and was explored for associations with ITFV. Mean age was 57 ± 13 years with a mean BMI of 30.0 ± 6.2 kg/m2 (range 20.3–38.4 kg/m2). Patients with versus without prior MI had similar demographics and BMI (29.4 ± 4.4 vs. 30.4 ± 7.9 kg/m2, p = 0.62). Patients with prior MI had lower mean peak strain than non-MI patients (p = 0.02), consistent with remote tissue contractile dysfunction. Inverse associations were identified between ITFV and mean peak strain in both the MI group (circumferential: r = 0.43, p = 0.03; radial: − 0.41, p = 0.04; minimum principal: r = 0.41, p = 0.04; maximum principal: r = − 0.43, p = 0.03) and non-MI group (circumferential: r = 0.42, p = 0.05; minimum principal: r = 0.45, p = 0.03). In those with prior MI higher ITFV was associated with a greater reduction in remote tissue strain. ITFV is associated with contractile dysfunction in patients with CAD. This association is prominent in the post-MI setting suggesting relevant influence on remote tissue health following ischemic injury. Expanded study of intra-thoracic adiposity as a modulator of myocardial health in patients with CAD is warranted.
- Open Access
- 2 May 2018
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 18 (1) , 1-11
Three-dimensional thoracic aorta principal strain analysis from routine ECG-gated computerized tomography: feasibility in patients undergoing transcatheter aortic valve replacement
Functional impairment of the aorta is a recognized complication of aortic and aortic valve disease. Aortic strain measurement provides effective quantification of mechanical aortic function, and 3-dimenional (3D) approaches may be desirable for serial evaluation. Computerized tomographic angiography (CTA) is routinely performed for various clinical indications, and offers the unique potential to study 3D aortic deformation. We sought to investigate the feasibility of performing 3D aortic strain analysis in a candidate population of patients undergoing transcatheter aortic valve replacement (TAVR). Twenty-one patients with severe aortic valve stenosis (AS) referred for TAVR underwent ECG-gated CTA and echocardiography. CTA images were analyzed using a 3D feature-tracking based technique to construct a dynamic aortic mesh model to perform peak principal strain amplitude (PPSA) analysis. Segmental strain values were correlated against clinical, hemodynamic and echocardiographic variables. Reproducibility analysis was performed. The mean patient age was 81±6 years. Mean left ventricular ejection fraction was 52±14%, aortic valve area (AVA) 0.6±0.3 cm2 and mean AS pressure gradient (MG) 44±11 mmHg. CTA-based 3D PPSA analysis was feasible in all subjects. Mean PPSA values for the global thoracic aorta, ascending aorta, aortic arch and descending aorta segments were 6.5±3.0, 10.2±6.0, 6.1±2.9 and 3.3±1.7%, respectively. 3D PSSA values demonstrated significantly more impairment with measures of worsening AS severity, including AVA and MG for the global thoracic aorta and ascending segment (p<0.001 for all). 3D PSSA was independently associated with AVA by multivariable modelling. Coefficients of variation for intra- and inter-observer variability were 5.8 and 7.2%, respectively. Three-dimensional aortic PPSA analysis is clinically feasible from routine ECG-gated CTA. Appropriate reductions in PSSA were identified with increasing AS hemodynamic severity. Expanded study of 3D aortic PSSA for patients with various forms of aortic disease is warranted.
- 2 May 2018
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 18 (1) , 1-11
Open AccessThree-dimensional thoracic aorta principal strain analysis from routine ECG-gated computerized tomography: feasibility in patients undergoing transcatheter aortic valve replacement
Functional impairment of the aorta is a recognized complication of aortic and aortic valve disease. Aortic strain measurement provides effective quantification of mechanical aortic function, and 3-dimenional (3D) approaches may be desirable for serial evaluation. Computerized tomographic angiography (CTA) is routinely performed for various clinical indications, and offers the unique potential to study 3D aortic deformation. We sought to investigate the feasibility of performing 3D aortic strain analysis in a candidate population of patients undergoing transcatheter aortic valve replacement (TAVR). Twenty-one patients with severe aortic valve stenosis (AS) referred for TAVR underwent ECG-gated CTA and echocardiography. CTA images were analyzed using a 3D feature-tracking based technique to construct a dynamic aortic mesh model to perform peak principal strain amplitude (PPSA) analysis. Segmental strain values were correlated against clinical, hemodynamic and echocardiographic variables. Reproducibility analysis was performed. The mean patient age was 81±6 years. Mean left ventricular ejection fraction was 52±14%, aortic valve area (AVA) 0.6±0.3 cm2 and mean AS pressure gradient (MG) 44±11 mmHg. CTA-based 3D PPSA analysis was feasible in all subjects. Mean PPSA values for the global thoracic aorta, ascending aorta, aortic arch and descending aorta segments were 6.5±3.0, 10.2±6.0, 6.1±2.9 and 3.3±1.7%, respectively. 3D PSSA values demonstrated significantly more impairment with measures of worsening AS severity, including AVA and MG for the global thoracic aorta and ascending segment (p<0.001 for all). 3D PSSA was independently associated with AVA by multivariable modelling. Coefficients of variation for intra- and inter-observer variability were 5.8 and 7.2%, respectively. Three-dimensional aortic PPSA analysis is clinically feasible from routine ECG-gated CTA. Appropriate reductions in PSSA were identified with increasing AS hemodynamic severity. Expanded study of 3D aortic PSSA for patients with various forms of aortic disease is warranted.
- Open Access
- 6 July 2017
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 33 (12) , 1979-1992
Clinical feasibility and validation of 3D principal strain analysis from cine MRI: comparison to 2D strain by MRI and 3D speckle tracking echocardiography
Two-dimensional (2D) strain analysis is constrained by geometry-dependent reference directions of deformation (i.e. radial, circumferential, and longitudinal) following the assumption of cylindrical chamber architecture. Three-dimensional (3D) principal strain analysis may overcome such limitations by referencing intrinsic (i.e. principal) directions of deformation. This study aimed to demonstrate clinical feasibility of 3D principal strain analysis from routine 2D cine MRI with validation to strain from 2D tagged cine analysis and 3D speckle tracking echocardiography. Thirty-one patients undergoing cardiac MRI were studied. 3D strain was measured from routine, multi-planar 2D cine SSFP images using custom software designed to apply 4D deformation fields to 3D cardiac models to derive principal strain. Comparisons of strain estimates versus those by 2D tagged cine, 2D non-tagged cine (feature tracking), and 3D speckle tracking echocardiography (STE) were performed. Mean age was 51 ± 14 (36% female). Mean LV ejection fraction was 66 ± 10% (range 37–80%). 3D principal strain analysis was feasible in all subjects and showed high inter- and intra-observer reproducibility (ICC range 0.83–0.97 and 0.83–0.98, respectively—p < 0.001 for all directions). Strong correlations of minimum and maximum principal strain were respectively observed versus the following: 3D STE estimates of longitudinal (r = 0.81 and r = −0.64), circumferential (r = 0.76 and r = −0.58) and radial (r = −0.80 and r = 0.63) strain (p < 0.001 for all); 2D tagged cine estimates of longitudinal (r = 0.81 and r = −0.81), circumferential (r = 0.87 and r = −0.85), and radial (r = −0.76 and r = 0.81) strain (p < 0.0001 for all); and 2D cine (feature tracking) estimates of longitudinal (r = 0.85 and −0.83), circumferential (r = 0.88 and r = −0.87), and radial strain (r = −0.79 and r = 0.84, p < 0.0001 for all). 3D principal strain analysis is feasible using routine, multi-planar 2D cine MRI and shows high reproducibility with strong correlations to 2D conventional strain analysis and 3D STE-based analysis. Given its independence from geometry-related directions of deformation this technique may offer unique benefit for the detection and prognostication of myocardial disease, and warrants expanded investigation.
- 6 July 2017
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 33 (12) , 1979-1992
Open AccessClinical feasibility and validation of 3D principal strain analysis from cine MRI: comparison to 2D strain by MRI and 3D speckle tracking echocardiography
Two-dimensional (2D) strain analysis is constrained by geometry-dependent reference directions of deformation (i.e. radial, circumferential, and longitudinal) following the assumption of cylindrical chamber architecture. Three-dimensional (3D) principal strain analysis may overcome such limitations by referencing intrinsic (i.e. principal) directions of deformation. This study aimed to demonstrate clinical feasibility of 3D principal strain analysis from routine 2D cine MRI with validation to strain from 2D tagged cine analysis and 3D speckle tracking echocardiography. Thirty-one patients undergoing cardiac MRI were studied. 3D strain was measured from routine, multi-planar 2D cine SSFP images using custom software designed to apply 4D deformation fields to 3D cardiac models to derive principal strain. Comparisons of strain estimates versus those by 2D tagged cine, 2D non-tagged cine (feature tracking), and 3D speckle tracking echocardiography (STE) were performed. Mean age was 51 ± 14 (36% female). Mean LV ejection fraction was 66 ± 10% (range 37–80%). 3D principal strain analysis was feasible in all subjects and showed high inter- and intra-observer reproducibility (ICC range 0.83–0.97 and 0.83–0.98, respectively—p < 0.001 for all directions). Strong correlations of minimum and maximum principal strain were respectively observed versus the following: 3D STE estimates of longitudinal (r = 0.81 and r = −0.64), circumferential (r = 0.76 and r = −0.58) and radial (r = −0.80 and r = 0.63) strain (p < 0.001 for all); 2D tagged cine estimates of longitudinal (r = 0.81 and r = −0.81), circumferential (r = 0.87 and r = −0.85), and radial (r = −0.76 and r = 0.81) strain (p < 0.0001 for all); and 2D cine (feature tracking) estimates of longitudinal (r = 0.85 and −0.83), circumferential (r = 0.88 and r = −0.87), and radial strain (r = −0.79 and r = 0.84, p < 0.0001 for all). 3D principal strain analysis is feasible using routine, multi-planar 2D cine MRI and shows high reproducibility with strong correlations to 2D conventional strain analysis and 3D STE-based analysis. Given its independence from geometry-related directions of deformation this technique may offer unique benefit for the detection and prognostication of myocardial disease, and warrants expanded investigation.
- Open Access
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 82-13
Objective criteria for septal fibrosis in non-ischemic dilated cardiomyopathy: validation for the prediction of future cardiovascular events
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 82-13
Open AccessObjective criteria for septal fibrosis in non-ischemic dilated cardiomyopathy: validation for the prediction of future cardiovascular events
- Open Access
- 1 December 2014
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 16 (1) , 85
Accuracy and reproducibility of semi-automated late gadolinium enhancement quantification techniques in patients with hypertrophic cardiomyopathy
- 1 December 2014
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 16 (1) , 85
Open AccessAccuracy and reproducibility of semi-automated late gadolinium enhancement quantification techniques in patients with hypertrophic cardiomyopathy