  • Early Results after Aortic Valve Replacement Using Last Generation Bioprosthetic Aortic Valve

    by Dritan Useini, Markus Schlömicher, Peter Haldenwang, Hamid Naraghi, Vadim Moustafine, Matthias Bechtel, Justus Strauch

    Introduction: Few data are available about the newest generation surgical bioprosthesis. We aimed to evaluate early clinical and hemodynamic outcomes after using the INSPIRIS RESILIA aortic valve (Edwards Lifesciences, Irvine, California, USA). Methods: Between July 2018 and April 2021, 80 patients underwent aortic valve replacement receiving the INSPIRIS RESILIA aortic valve at our institution. Primary outcomes were the composite of early mortality, stroke, and myocardial infarction. Secondary outcomes were hemodynamic performances of the valve, paravalvular leakage, and new pacemaker implantation. Results: The mean age of the study population was 60.6 ± 8.3 years. The mean Society of Thoracic Surgery-Predicted Risk of Mortality score was 2.9 ± 1.7%. In 43.7% of the patients, concomitant surgery was performed. The in-hospital mortality, all-stroke, and myocardial infarction rates were 2.5%, 1.2%, and 1.2%, respectively. No valve was explanted and no redo was performed. The mean postoperative trans-prosthetic gradient at discharge was 10.2 ± 4.1 mm Hg. There was no need for new pacemaker implantation. We registered only two cases with minimal (trace) paravalvular leakage. Conclusion: The use of the INSPIRIS RESILIA aortic valve in a young, low-risk population is safe and associated with very good early clinical and hemodynamic outcomes.


  • Open Access

    The Use of Rapid Deployment Valves in Combined Aortic and Mitral Valve Surgery

    by Markus Schlömicher, Matthias Bechtel, Zulfugar Taghiyev, Yazan Al-Jabery, Peter Lukas Haldenwang, Vadim Moustafine, Justus Thomas Strauch

    Patients undergoing multiple valve surgery represent a high-risk group who could potentially benefit from a reduction of cross-clamp and cardiopulmonary bypass times because prolonged bypass and cross-clamp times are considered independent risk factors for increased morbidity and mortality after cardiac surgery. Between July 2013 and November 2014, 16 patients underwent rapid deployment aortic valve replacement with the EDWARDS INTUITY valve system in the setting of concomitant mitral disease. Fifteen patients showed mitral regurgitation, whereas one patient had severe mitral stenosis. Fourteen patients received mitral valve repair and two patients received biological mitral valve replacement. Tricuspid valve repair was performed additionally in two patients. The mean ± SD age was 72.8 ± 8.4 years, and the mean ± SD logistic EuroSCORE II is 8.7% ± 3.4%. Within a 30-day perioperative period, no patient was lost (n = 0). The mean ± SD follow-up time was 11 ± 2 months. At 1 year, the overall survival was 81% (n = 13). A mean ± SD transaortic gradient of 10.7 ± 2.3 mm Hg and a mean ± SD effective orifice area of 1.7 ± 0.3 cm2 were measured echocardiographically. No higher-grade paravalvular leak (aortic insufficiency > 1+) occurred. Eight patients (61%) had no residual mitral regurgitation, four patients (30%) showed trivial regurgitation (1/4), and one patient (7.3%) had moderate mitral regurgitation (2/4). No interference of the subannular stent frame with the reconstructed valve or the biological mitral prosthesis was seen. Rapid deployment aortic valve replacement with the EDWARDS INTUITY valve system in combined aortic and mitral valve surgery can be performed safely with reproducible results. One-year follow-up data of this small series shows encouraging results potentially justifying the extension of the indication for rapid deployment valves to patients with concomitant mitral disease. Especially elderly patients undergoing multiple valve surgery may benefit from a reduction of cardiopulmonary bypass and myocardial ischemic times.

  • Poster session 30: Modelling and simulation III

    by Markus Bongert, Kuno Kloos, Marius Geller, Markus Schlömicher, Tim Ricken, Volkmar Nicolas, Justus Strauch

    • 1 January 2017
      • Vol. 26  (1) , 90-97

    Aortic Valve Replacement with the Labcor TLPB Supra™ Porcine Bioprosthesis: Intermediate Clinical and Echocardiographic Outcomes.

    by Markus Schlömicher, Zulfugar Taghiyev, Yazan Al-Jabery, Peter Lukas Haldenwang, Leif Markthaler, Vadim Moustafine, Axel Maria Laczkovics, Justus Thomas Strauch, Matthias Bechtel

    The Labcor TBLP Supra™ prosthesis is a second-generation tissue valve that has evolved from the Labcor TBLP™ prosthesis, first introduced in 1984. The Supra prosthesis is a triple-composite porcine valve, with no specific anticalcification treatment being used in its production other than standard tissue fixation with 0.4% glutaraldehyde. To date, more than 100,000 Supra valves have been implanted, mainly in South America. Despite this remarkably high number of implants, only marginal data exist concerning durability and safety issues. Hence, the study aim was to analyze short-term and intermediate outcomes relating to the clinical and hemodynamic performance of the Supra valve, as well as complication rates METHODS: A follow up study was initiated to evaluate outcomes and durability of the Labcor Supra prosthesis. Between September 2004 and October 2010, a total of 331 patients (mean age 75.8 ± 7.2 years; mean logistic EuroSCORE 8.5 ± 2.3%) underwent aortic valve replacement using the Supra porcine bioprosthesis. The 30-day mortality rate was 4.8% (n = 16). The overall actuarial five-year survival was 72.3 ± 4.9%, and eight-year survival was 60.4 ± 5.6%. Actuarial freedom from reoperation was 96.3 ± 2.4% after five years, and 92.5 ± 3.5% after eight years. Actuarial freedom from structural valve deterioration (SVD) was 99.7 ± 0.3% at five years, and 97.2 ± 0.8% at eight years; actuarial freedom from thromboembolism was 97.5 ± 1.0% and 95.7 ± 1.6% at these times. Actuarial freedom from event rates for endocarditis were 99.5 ± 0.3% and 96.8 ± 0.6%, and 96.1 ± 0.9% and 93.0 ± 1.4% for reoperation CONCLUSIONS: No evidence was found of increased rates of SVD. All parameters studied were comparable to those examined for other second-generation porcine prostheses. Further long-term follow up investigations are required however, for the final judgment of this prosthesis.

  • Rapid deployment aortic valve replacement in the setting of concomitant mitral valve procedures

    by Matthias Bechtel, Markus Schlömicher, Vadim Moustafine, Justus Thomas Strauch

    The technique of rapid deployment aortic valve implantation in patients with concomitant mitral valve surgery is described and the outcome of our first 25 patients reported.


  • Spinal Cord Ischemia After Selective Cerebral Perfusion in a Porcine “Frozen Elephant Trunk” Simulation Model

    by Peter L. Haldenwang, Nora Prochnow, Andreas Baumann, Dirk Buchwald, Lorine Häuser, Markus Schlömicher, Damian Ziebura, Inge Schmitz, Hildegard Christ, Justus T. Strauch


  • Simultaneous Double Valve-in-Valve TAVI Procedure for Failed Bioprostheses

    by Markus Schlömicher, Peter Lukas Haldenwang, Vadim Moustafine, Matthias Bechtel, Justus Thomas Strauch


  • Minimal access rapid deployment aortic valve replacement: Initial single-center experience and 12-month outcomes

    by Markus Schlömicher, Peter Lukas Haldenwang, Vadim Moustafine, Matthias Bechtel, Justus Thomas Strauch


  • Detection of Valve Malfunction after Mechanical MVR using Digital Phonocardiography

    by M. Schlömicher, A. Brensing, A. Laczkovics

    We present the case of a 63-year-old female patient who developed severe chronic dyspnea two years after mechanical mitral valve replacement (MVR). Conventional cardiac diagnostics including echocardiography, fluoroscopy, right and left heart catheterization could not detect any malfunction. Only digital phonocardiography was able to show alterations of the typical acoustic signal. Based on the symptoms, the clinical history and these abnormal findings the decision was taken to reoperate. Intraoperatively, a ruptured tendinous chord was found, impeding the inferior leaflet. Redo MVR was performed