Martin Dostál
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Martin Dostál has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Stanislav Solnař
Czech Technical University in Prague, Faculty of Mechanical Engineering, Department of Process Engineering, Technická 4, 166 07 Prague, Czech Republic
2 shared publications- Tomáš Jirout
Department of Process Engineering, Czech Technical University in Prague, 16600 Prague, Czech Republic
2 shared publications - Viktor Vajc
Department of Process Engineering, Faculty of Mechanical Engineering, Czech Technical University, 166 07 Prague, Czech Republic
2 shared publications - Dita Jiroutová
Klokner Institute, Czech Technical University in Prague, Prague 6 - Dejvice, Czech Republic
1 shared publication - Ivan Fořt
Czech Technical University in Prague, Faculty of Mechanical Engineering, Department of Process Engineering, Technická 4, 166 07 Prague, Czech Republic
1 shared publication - Jiří Moravec
Faculty of Mechanical Engineering, Department of Process Engineering, Czech Technical University in Prague, Prague 6 - Dejvice, Czech Republic
1 shared publication
Latest Publications
- Open Access
- 7 April 2023
- Published by Springer Nature in Archive of Applied Mechanics
- Vol. 93 (7) , 2877-2890
Model fluids substituting fresh UHPC mixtures flow behaviour
Carboxymethylcellulose (CMC) and ultrasound gel (USG) seem to be suitable clear model fluids to substitute real ultra-high-performance concretes (UHPCs), enabling experimental monitoring of events occurring within these mixtures at similar flow behaviour. USG is eligible for UHPC mixtures with significant yield stress. CMC having a suitable concentration is better for UHPCs exhibiting indistinct yield stress. The rheological behaviour of real UHPC mixtures as well as substituting model fluids was measured using a non-standard system consisting of a vessel stirred by an anchor or a screw agitator. In addition, a standard rotational rheometer system with concentric cylinder geometry was used for optimization of the above-mentioned method of measurement and also for measuring the rheological parameters of the substituting model fluids. This article deals with the methodology for measuring the rheological properties of these substances and presents the results of the measurements using flow curves and rheological models.
- 7 April 2023
- Published by Springer Nature in Archive of Applied Mechanics
- Vol. 93 (7) , 2877-2890
Open AccessModel fluids substituting fresh UHPC mixtures flow behaviour
Carboxymethylcellulose (CMC) and ultrasound gel (USG) seem to be suitable clear model fluids to substitute real ultra-high-performance concretes (UHPCs), enabling experimental monitoring of events occurring within these mixtures at similar flow behaviour. USG is eligible for UHPC mixtures with significant yield stress. CMC having a suitable concentration is better for UHPCs exhibiting indistinct yield stress. The rheological behaviour of real UHPC mixtures as well as substituting model fluids was measured using a non-standard system consisting of a vessel stirred by an anchor or a screw agitator. In addition, a standard rotational rheometer system with concentric cylinder geometry was used for optimization of the above-mentioned method of measurement and also for measuring the rheological parameters of the substituting model fluids. This article deals with the methodology for measuring the rheological properties of these substances and presents the results of the measurements using flow curves and rheological models.
- Open Access
- 24 October 2022
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 269, 01009
Gnielinski’s correlation and a modern temperature-oscillation method for measuring heat transfer coefficients
The heat transfer coeffcient is one of the most important parameters in the design of apparatuses in which convective heat transport takes place. Classical direct methods based on determining basic thermal quantities can be used for measuring heat transfer coeffcients. Another option is to measure concentrations, electric current or other quantities that can be transformed to thermal quantities using the analogy between heat and mass transport. The temperature-oscillation method is less frequently used, although the theoretical basis of the method dates back to 1997, and although the method has the major advantage that the heat transfer coeffcients can be measured without making any contact with the heat transfer surface. In the temperatureoscillation method, the heat transfer surface is exposed to an oscillating heat flux, and the temperature response on this surface can be measured by a contactless method (e.g. infra-red thermography). The heat transfercoeffcients can be determined on the basis of mathematical relations between the oscillating heat flux and the temperature response. However, the method depends on an appropriate method for processing the measured data when it is necessary to correct some conditions that are not included in the mathematical model. This paper evaluates the impact of processing the experimental data on the resulting heat transfer coeffcients in one of the basic geometrical configurations – the flow of a liquid in a pipe with a circular cross section. In this paper, we present the results of a comparison of real experiments based on the temperature oscillation method and numerical modeling of the heat transfer in this geometry, using the ANSYS CFD commercial system.
- 24 October 2022
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 269, 01009
Open AccessGnielinski’s correlation and a modern temperature-oscillation method for measuring heat transfer coefficients
The heat transfer coeffcient is one of the most important parameters in the design of apparatuses in which convective heat transport takes place. Classical direct methods based on determining basic thermal quantities can be used for measuring heat transfer coeffcients. Another option is to measure concentrations, electric current or other quantities that can be transformed to thermal quantities using the analogy between heat and mass transport. The temperature-oscillation method is less frequently used, although the theoretical basis of the method dates back to 1997, and although the method has the major advantage that the heat transfer coeffcients can be measured without making any contact with the heat transfer surface. In the temperatureoscillation method, the heat transfer surface is exposed to an oscillating heat flux, and the temperature response on this surface can be measured by a contactless method (e.g. infra-red thermography). The heat transfercoeffcients can be determined on the basis of mathematical relations between the oscillating heat flux and the temperature response. However, the method depends on an appropriate method for processing the measured data when it is necessary to correct some conditions that are not included in the mathematical model. This paper evaluates the impact of processing the experimental data on the resulting heat transfer coeffcients in one of the basic geometrical configurations – the flow of a liquid in a pipe with a circular cross section. In this paper, we present the results of a comparison of real experiments based on the temperature oscillation method and numerical modeling of the heat transfer in this geometry, using the ANSYS CFD commercial system.
- Open Access
Pool Boiling Heat Transfer Coefficients in Mixtures of Water and Glycerin
Heat transfer coefficients were investigated for saturated nucleate pool boiling of binary mixtures of water and glycerin at atmospheric pressure in a wide range of concentrations and heat fluxes. Mixtures with water mass fractions from to were boiled on a horizontal flat copper surface at heat fluxes from about 25 up to . Experiments were carried out by static and dynamic method of measurement. Results of the static method show that the impact of mixture effects on heat transfer coefficient cannot be neglected and ideal heat transfer coefficient has to be corrected for all investigated concentrations and heat fluxes. Experimental data are correlated with the empirical correlation with mean relative error of . Taking mixture effects into account, data are also successfully correlated with the combination of Stephan and Abdelsalam (1980) and Schlünder (1982) correlations with mean relative error of about . Recommended coefficients of Schlünder correlation and were found to be acceptable for all investigated mixtures. The dynamic method was developed for fast measurement of heat transfer coefficients at continuous change of composition of boiling mixture. The dynamic method was tested for water–glycerin mixtures with water mass fractions from down to . Results of the dynamic method were found to be comparable with the static method. For water–glycerin mixtures with higher water mass fractions, precise temperature measurements are needed.Open AccessPool Boiling Heat Transfer Coefficients in Mixtures of Water and Glycerin
Heat transfer coefficients were investigated for saturated nucleate pool boiling of binary mixtures of water and glycerin at atmospheric pressure in a wide range of concentrations and heat fluxes. Mixtures with water mass fractions from to were boiled on a horizontal flat copper surface at heat fluxes from about 25 up to . Experiments were carried out by static and dynamic method of measurement. Results of the static method show that the impact of mixture effects on heat transfer coefficient cannot be neglected and ideal heat transfer coefficient has to be corrected for all investigated concentrations and heat fluxes. Experimental data are correlated with the empirical correlation with mean relative error of . Taking mixture effects into account, data are also successfully correlated with the combination of Stephan and Abdelsalam (1980) and Schlünder (1982) correlations with mean relative error of about . Recommended coefficients of Schlünder correlation and were found to be acceptable for all investigated mixtures. The dynamic method was developed for fast measurement of heat transfer coefficients at continuous change of composition of boiling mixture. The dynamic method was tested for water–glycerin mixtures with water mass fractions from down to . Results of the dynamic method were found to be comparable with the static method. For water–glycerin mixtures with higher water mass fractions, precise temperature measurements are needed. - Open Access
- 28 June 2019
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 213, 02090
First testing experiments with measurement of pool boiling heat transfer coefficient on a new apparatus
We have designed a simple apparatus for measurement of heat transfer during pool boiling in order to find or create suitable correlations for heat-transfer coefficient, which could be used for various liquids and conditions. We have run several testing experiments with tap and deionized water. This contribution presents proceedings and the first results of these experiments as well as comparison of these results with some published and verified correlations.
- 28 June 2019
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 213, 02090
Open AccessFirst testing experiments with measurement of pool boiling heat transfer coefficient on a new apparatus
We have designed a simple apparatus for measurement of heat transfer during pool boiling in order to find or create suitable correlations for heat-transfer coefficient, which could be used for various liquids and conditions. We have run several testing experiments with tap and deionized water. This contribution presents proceedings and the first results of these experiments as well as comparison of these results with some published and verified correlations.
- 1 June 2018
- Published by Avestia Publishing
Heat Transfer Measurements with Temperature Oscillation Method
- 1 June 2018
- Published by Avestia Publishing
Heat Transfer Measurements with Temperature Oscillation Method
- 7 October 2014
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 92 (12) , 2115-2121
Analysis of heat transfer in a vessel with helical pipe coil and multistage impeller
- 7 October 2014
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 92 (12) , 2115-2121
Analysis of heat transfer in a vessel with helical pipe coil and multistage impeller