Renata Obiala
Research Subjects
Renata Obiala has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Matthias Braun
University of Luxembourg
6 shared publications - Christoph Odenbreit
University of Luxembourg
4 shared publications - Job Duarte da Costa
University of Luxembourg ArcelorMittal Chair of Steel and Façade Engineering Luxembourg
2 shared publications Anthony Peirce
Department of Mathematics; University of British Columbia; Vancouver British Columbia V6T 1Z2 Canada
1 shared publication- Dario Zaganelli
ArcelorMittal Europe - Long Products; L-4009 Esch sur Alzette Luxembourg
1 shared publication - Florian Eggert
University of Stuttgart
1 shared publication
Latest Publications
- Open Access
- 27 June 2018
- Published by Universitat Politecnica de Valencia
Development of an innovative type of shear connector dedicated to fully embedded steel-concrete composite columns – experimental and numerical investigations.
Development of an innovative type of shear connector dedicated to fully embedded steel-concrete composite columns – experimental and numerical investigations.
- 27 June 2018
- Published by Universitat Politecnica de Valencia
Open AccessDevelopment of an innovative type of shear connector dedicated to fully embedded steel-concrete composite columns – experimental and numerical investigations.
Development of an innovative type of shear connector dedicated to fully embedded steel-concrete composite columns – experimental and numerical investigations.
03.05: Experimental investigations on semi‐continuous encased composite joints
This article is not available for publication.
03.05: Experimental investigations on semi‐continuous encased composite joints
This article is not available for publication.
- 12 May 2017
- Published by Wiley in Steel Construction
- Vol. 10 (2) , 93-114
Design of single-span beams for SLS and ULS using semi-continuous beam-to-column joints
- 12 May 2017
- Published by Wiley in Steel Construction
- Vol. 10 (2) , 93-114
Design of single-span beams for SLS and ULS using semi-continuous beam-to-column joints
- 11 May 2015
- Published by Wiley in Steel Construction
- Vol. 8 (2) , 85-89
Slim‐floor construction using hollow‐core and composite decking systems
This article reviews the performance characteristics of and some recent developments in slim‐floor and integrated beam construction. This form of construction provides a flat floor using precast concrete slabs or deep composite decking and offers advantages over other forms of construction in many sectors. Composite slim‐floor beams have superior stiffness and can achieve longer spans.
- 11 May 2015
- Published by Wiley in Steel Construction
- Vol. 8 (2) , 85-89
Slim‐floor construction using hollow‐core and composite decking systems
This article reviews the performance characteristics of and some recent developments in slim‐floor and integrated beam construction. This form of construction provides a flat floor using precast concrete slabs or deep composite decking and offers advantages over other forms of construction in many sectors. Composite slim‐floor beams have superior stiffness and can achieve longer spans.
- 11 May 2015
- Published by Wiley in Steel Construction
- Vol. 8 (2) , 90-95
Composite action in shallow floor beams with different shear connections
Shallow floor beams, abbreviated to SF beams and also known as slim floor beams, are beams where most of the beam member is embedded in the concrete decking of the floor, which is supported on the lower flange or outward ledge of the beam. SF beams are composite members in which composite action can be utilized in both the serviceability and ultimate limit state conditions or only at the serviceability limit state, depending on the decking type. This paper discusses the composite action in SF beams when the decking is of a solid type, i.e. consists of a reinforced concrete slab or composite slab with profiled sheeting, making it possible to benefit from the composite behaviour at all important limit states. Hollow‐core decking supported on SF beams is a special case in which the composite action can only be employed in the design for serviceability conditions. Another paper covers the special issues regarding the design of such shallow floors.
- 11 May 2015
- Published by Wiley in Steel Construction
- Vol. 8 (2) , 90-95
Composite action in shallow floor beams with different shear connections
Shallow floor beams, abbreviated to SF beams and also known as slim floor beams, are beams where most of the beam member is embedded in the concrete decking of the floor, which is supported on the lower flange or outward ledge of the beam. SF beams are composite members in which composite action can be utilized in both the serviceability and ultimate limit state conditions or only at the serviceability limit state, depending on the decking type. This paper discusses the composite action in SF beams when the decking is of a solid type, i.e. consists of a reinforced concrete slab or composite slab with profiled sheeting, making it possible to benefit from the composite behaviour at all important limit states. Hollow‐core decking supported on SF beams is a special case in which the composite action can only be employed in the design for serviceability conditions. Another paper covers the special issues regarding the design of such shallow floors.
Experimentelle Untersuchungen von Slim‐Floor‐Trägern in Verbundbauweise
Die Kombination von integrierten Deckenträgern mit Betondübeln ermöglicht eine äußerst materialsparende und wirtschaftliche Realisierung weitgespannter Slim‐Floor‐Träger in Verbundbauweise (Composite Slim‐Floor Beams – CoSFB). Mangels Bemessungsregeln für diese vorgesehene Anwendung wurden ab 2009 Bauteil‐ und Push‐Out‐Versuche zur Untersuchung des Tragverhaltens der Betondübel durchgeführt und der Einfluss der für die Tragfähigkeit maßgebenden Parameter bestimmt [1]. In diesem Beitrag werden die durchgeführten Versuche und deren Auswertung beschrieben sowie die Bestimmung der charakteristischen Tragfähigkeit der CoSFB‐Betondübel ausführlich erläutert. Die Ergebnisse sind in eine allgemeine bauaufsichtliche Zulassung [2] eingeflossen, worin neben den Dübeltragfähigkeiten auch Anwendungsgrenzen und Bestimmungen zur Ausführung geregelt sind.Experimental investigation of Composite Slim‐Floor Beams – Application of concrete dowels. The combination of integrated beams with concrete dowels allows for a significant material saving and an economical realization of long‐span Composite Slim‐Floor Beams (CoSFB). Due to lack of design rules for the proposed application, since 2009 member tests and Push‐Out tests were performed in order to investigate the load bearing behaviour of the concrete dowels and to determine an influence of relevant parameters on the resistance of the system [1]. This paper describes the accomplished tests and the evaluation of the experimental results as well as it explains the determination of the characteristic resistance of CoSFB concrete dowels. The results led to a general technical approval [2] in which the dowel load bearing capacity, application limits and rules for execution are given.
Experimentelle Untersuchungen von Slim‐Floor‐Trägern in Verbundbauweise
Die Kombination von integrierten Deckenträgern mit Betondübeln ermöglicht eine äußerst materialsparende und wirtschaftliche Realisierung weitgespannter Slim‐Floor‐Träger in Verbundbauweise (Composite Slim‐Floor Beams – CoSFB). Mangels Bemessungsregeln für diese vorgesehene Anwendung wurden ab 2009 Bauteil‐ und Push‐Out‐Versuche zur Untersuchung des Tragverhaltens der Betondübel durchgeführt und der Einfluss der für die Tragfähigkeit maßgebenden Parameter bestimmt [1]. In diesem Beitrag werden die durchgeführten Versuche und deren Auswertung beschrieben sowie die Bestimmung der charakteristischen Tragfähigkeit der CoSFB‐Betondübel ausführlich erläutert. Die Ergebnisse sind in eine allgemeine bauaufsichtliche Zulassung [2] eingeflossen, worin neben den Dübeltragfähigkeiten auch Anwendungsgrenzen und Bestimmungen zur Ausführung geregelt sind.Experimental investigation of Composite Slim‐Floor Beams – Application of concrete dowels. The combination of integrated beams with concrete dowels allows for a significant material saving and an economical realization of long‐span Composite Slim‐Floor Beams (CoSFB). Due to lack of design rules for the proposed application, since 2009 member tests and Push‐Out tests were performed in order to investigate the load bearing behaviour of the concrete dowels and to determine an influence of relevant parameters on the resistance of the system [1]. This paper describes the accomplished tests and the evaluation of the experimental results as well as it explains the determination of the characteristic resistance of CoSFB concrete dowels. The results led to a general technical approval [2] in which the dowel load bearing capacity, application limits and rules for execution are given.