Jie Shao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jie Shao has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Juncheng Lu
Department of Optical Engineering, School of Physics and Electronic Engineering, Zhejiang Normal University, Jinhua 321004, China
4 shared publicationsJie Guo
Zhejiang Normal Univ. (China)
3 shared publicationsChenying Shen
Key Laboratory of Optical Information Detection and Display Technology of Zhejiang, Zhejiang Normal University, Jinhua 321004, China
2 shared publications- Daru Chen
Zhejiang Normal University
2 shared publications Jiasheng Zhao
Key Laboratory of Optical Information Detection and Display Technology of Zhejiang, Zhejiang Normal University, Jinhua 321004, China
2 shared publicationsJindong Xiang
Institute of Information Optics, Zhejiang Normal University, Jinhua 321004, China
2 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 23 January 2026
- Published by Elsevier in Photoacoustics
- Vol. 48, 100802
Real-time in Vivo monitoring of photosynthesis in individual leaves by frequency-locked quartz-enhanced photoacoustic spectroscopy
- 23 January 2026
- Published by Elsevier in Photoacoustics
- Vol. 48, 100802
Top Cited PapersOpen AccessReal-time in Vivo monitoring of photosynthesis in individual leaves by frequency-locked quartz-enhanced photoacoustic spectroscopy
- Open Access
- 5 April 2023
- Published by Elsevier in Photoacoustics
- Vol. 30, 100488
Continuous real-time monitoring of carbon dioxide emitted from human skin by quartz-enhanced photoacoustic spectroscopy
- 5 April 2023
- Published by Elsevier in Photoacoustics
- Vol. 30, 100488
Open AccessContinuous real-time monitoring of carbon dioxide emitted from human skin by quartz-enhanced photoacoustic spectroscopy
- 1 March 2023
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 62 (03) , 034104-11
Dynamic ammonia measurement based on quantum cascade laser absorption spectroscopy
We investigate the key techniques in ammonia (NH3) measurement based on midinfrared quantum cascade laser absorption spectroscopy technology. As the detection object, the system chose two absorption peaks splitting near 1122.16 cm − 1 at 0.3 atm. It was also combined with wavelength modulation spectroscopy technology and a high-temperature environment to reduce NH3 absorption in dynamic measurement. Allan variance was used to analyze the stability of the system. The optimal time to measure the average was 195 s, and the minimum detection limit was 121.58 ppb.
- 1 March 2023
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 62 (03) , 034104-11
Dynamic ammonia measurement based on quantum cascade laser absorption spectroscopy
We investigate the key techniques in ammonia (NH3) measurement based on midinfrared quantum cascade laser absorption spectroscopy technology. As the detection object, the system chose two absorption peaks splitting near 1122.16 cm − 1 at 0.3 atm. It was also combined with wavelength modulation spectroscopy technology and a high-temperature environment to reduce NH3 absorption in dynamic measurement. Allan variance was used to analyze the stability of the system. The optimal time to measure the average was 195 s, and the minimum detection limit was 121.58 ppb.
- Open Access
A Dual-Band Carbon Dioxide Sensor Based on Metal–TiO2–Metal Metasurface Covered by Functional Material
Highly sensitive and integrated optical multi-band CO2 sensors are significant at the shortwave infrared (SWIR) region and still lack research. A compact CO2 sensor composed of a Au-disk/TiO2-cylinder/Au-film metasurface coated by polyhexamethylene biguanide (PHMB) film, functioning at multi-band resonances as well as having high sensitivity to gas concentrations, is presented. It can be employed as a dual-band narrowband absorber, producing two strongly resonant modes at the SWIR region under a reflection-type framework of linearly polarized incidence. Moreover, the metasurface sensor possesses high refractive index sensitivity of 109.25 pm/ppm at around 1040 nm and 42.57 pm/ppm at around 1330 nm in the range of 200–600 ppm, which is suitable for detecting atmospheric CO2. Furthermore, the numerical results show that the sensitivity increases with a thicker PHMB film and optimizes at a thickness above 600 nm. The physical mechanism reveals that the higher order mode exhibits more extended near-field energy than the lower order mode, resulting in more sensitivity towards the surroundings. The design and results of our investigation show high-quality CO2 sensing performance which functions at dual spectrum bands in the SWIR region and is promising for integrated photonic applications.
Open AccessA Dual-Band Carbon Dioxide Sensor Based on Metal–TiO2–Metal Metasurface Covered by Functional Material
Highly sensitive and integrated optical multi-band CO2 sensors are significant at the shortwave infrared (SWIR) region and still lack research. A compact CO2 sensor composed of a Au-disk/TiO2-cylinder/Au-film metasurface coated by polyhexamethylene biguanide (PHMB) film, functioning at multi-band resonances as well as having high sensitivity to gas concentrations, is presented. It can be employed as a dual-band narrowband absorber, producing two strongly resonant modes at the SWIR region under a reflection-type framework of linearly polarized incidence. Moreover, the metasurface sensor possesses high refractive index sensitivity of 109.25 pm/ppm at around 1040 nm and 42.57 pm/ppm at around 1330 nm in the range of 200–600 ppm, which is suitable for detecting atmospheric CO2. Furthermore, the numerical results show that the sensitivity increases with a thicker PHMB film and optimizes at a thickness above 600 nm. The physical mechanism reveals that the higher order mode exhibits more extended near-field energy than the lower order mode, resulting in more sensitivity towards the surroundings. The design and results of our investigation show high-quality CO2 sensing performance which functions at dual spectrum bands in the SWIR region and is promising for integrated photonic applications.
- 25 January 2022
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 65 (5) , 1099-1107
Estimation of Staphylococcus aureus growth rates from CO2 with absorption spectroscopy
- 25 January 2022
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 65 (5) , 1099-1107
Estimation of Staphylococcus aureus growth rates from CO2 with absorption spectroscopy
- 11 January 2021
- Published by IOP Publishing in Chinese Physics B
- Vol. 30 (5) , 054203
A pressure-calibration method of wavelength modulation spectroscopy in sealed microbial growth environment*
A new pressure-calibration method for calibrating the reduction of second harmonic (2f) amplitude caused by pressure broadening effect in sealed microbial growth environment is present. The new method combines with linewidth compensation and modulation depth compensation and makes the 2f amplitude accurately retrieve metabolic CO2 in microbial growth. In order to verify the method, a simulation experiment is developed, in which the increasing CO2 concentration leads to the increasing pressure. Comparing with the relation between the traditional 2f amplitude and gas concentration, there is a monotonous relation between the calibrated 2f amplitude and CO2 concentration, particularly, a linear relation is present when the CO2 concentration is replaced with the CO2 particle number. In terms of microbial measurement, the growth of Escherichia coli is measured, and the culture bottle is sealed during the microbial growth process. The experimental results show that, comparing to the microbial growth retrieved by traditional 2f amplitude, the calibrated 2f amplitude can accurately retrieve microbial growth in sealed environment.
- 11 January 2021
- Published by IOP Publishing in Chinese Physics B
- Vol. 30 (5) , 054203
A pressure-calibration method of wavelength modulation spectroscopy in sealed microbial growth environment*
A new pressure-calibration method for calibrating the reduction of second harmonic (2f) amplitude caused by pressure broadening effect in sealed microbial growth environment is present. The new method combines with linewidth compensation and modulation depth compensation and makes the 2f amplitude accurately retrieve metabolic CO2 in microbial growth. In order to verify the method, a simulation experiment is developed, in which the increasing CO2 concentration leads to the increasing pressure. Comparing with the relation between the traditional 2f amplitude and gas concentration, there is a monotonous relation between the calibrated 2f amplitude and CO2 concentration, particularly, a linear relation is present when the CO2 concentration is replaced with the CO2 particle number. In terms of microbial measurement, the growth of Escherichia coli is measured, and the culture bottle is sealed during the microbial growth process. The experimental results show that, comparing to the microbial growth retrieved by traditional 2f amplitude, the calibrated 2f amplitude can accurately retrieve microbial growth in sealed environment.
- 16 March 2016
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (9) , 2339-2345
Wavelength-modulated tunable diode-laser absorption spectrometry for real-time monitoring of microbial growth
It is important to monitor and assess the growth of micro-organisms under various conditions. Yet, thus far there has been no technique to do this with the required speed and accuracy. This work demonstrates swift and accurate assessment of the concentration of carbon dioxide that is produced by use of a wavelength-modulated tunable diode-laser based absorption spectroscopy (WM-TDLAS). It is shown by experiments on two types of bacteria, Staphylococcus aureus and Candida albicans, that the technique can produce high signal-to-noise-ratio data from bacteria grown in confined spaces and exposed to limited amounts of nutrients that can be used for extraction of growth parameters by fitting of the Gompertz model. By applying the technique to S. aureus bacteria at various temperatures (in the 25°C to 42°C range), it is specifically shown that both the maximum growth rate and the so-called lag time have a strong temperature dependence (under the specific conditions with a maximum of the former at 37°C) that matches conventional models well for bacterial growth. Hence, it is demonstrated that WM-TDLAS monitoring is a user-friendly, non-intrusive, and label-free technique that swiftly, and with high signal-to-noise-ratio, can be used for rapid (on the Hz scale) and accurate assessment of bacterial growth.- 16 March 2016
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (9) , 2339-2345
Wavelength-modulated tunable diode-laser absorption spectrometry for real-time monitoring of microbial growth
It is important to monitor and assess the growth of micro-organisms under various conditions. Yet, thus far there has been no technique to do this with the required speed and accuracy. This work demonstrates swift and accurate assessment of the concentration of carbon dioxide that is produced by use of a wavelength-modulated tunable diode-laser based absorption spectroscopy (WM-TDLAS). It is shown by experiments on two types of bacteria, Staphylococcus aureus and Candida albicans, that the technique can produce high signal-to-noise-ratio data from bacteria grown in confined spaces and exposed to limited amounts of nutrients that can be used for extraction of growth parameters by fitting of the Gompertz model. By applying the technique to S. aureus bacteria at various temperatures (in the 25°C to 42°C range), it is specifically shown that both the maximum growth rate and the so-called lag time have a strong temperature dependence (under the specific conditions with a maximum of the former at 37°C) that matches conventional models well for bacterial growth. Hence, it is demonstrated that WM-TDLAS monitoring is a user-friendly, non-intrusive, and label-free technique that swiftly, and with high signal-to-noise-ratio, can be used for rapid (on the Hz scale) and accurate assessment of bacterial growth.- 1 August 2015
- Vol. 35 (8) , 2078-82
[High-Sensitive Carbon Dioxide Detection Using Quartz-Enhanced Photoacoustic Spectroscopy with a 2.0 μm Distributed Feedback Laser].
A carbon dioxide (CO2) sensor is developed using quartz enhanced photoacoustic spectroscopy (QEPAS) with a 2.0 μm distributed feedback diode laser. The detection is based on a 2f wavelength-modulation spectroscopy approach by dithering and scanning the laser current. The laser modulation depth is optimized at normal atmosphere pressure and room temperature. The influence of the H2O presence in the sample gas mixture on the CO2 sensor performance is also investigated. The results show that, with 1% CO2 concentration, the H2O in the concentration ranges of 0 to 0.2% has an effect on the CO2 signal amplitude and phase, and the largest amplitude difference is ~2.1 times. When the H2O concentration is over 0.2%, the CO2 signal amplitude is saturated and remains steady. Atmospheric CO2 concentration is well measured using the optimal sensor parameters. Benefiting from the strong absorption line intensity at 4989.97 cm(-1), a detection limit of 19 ppm (1σ, 300 ms averaging time) is achieved, which corresponds to a normalized noise equivalent absorption coefficient of 4.71 × 10(-9) cm(-1) · W · Hz(-1/2).
- 1 August 2015
- Vol. 35 (8) , 2078-82
[High-Sensitive Carbon Dioxide Detection Using Quartz-Enhanced Photoacoustic Spectroscopy with a 2.0 μm Distributed Feedback Laser].
A carbon dioxide (CO2) sensor is developed using quartz enhanced photoacoustic spectroscopy (QEPAS) with a 2.0 μm distributed feedback diode laser. The detection is based on a 2f wavelength-modulation spectroscopy approach by dithering and scanning the laser current. The laser modulation depth is optimized at normal atmosphere pressure and room temperature. The influence of the H2O presence in the sample gas mixture on the CO2 sensor performance is also investigated. The results show that, with 1% CO2 concentration, the H2O in the concentration ranges of 0 to 0.2% has an effect on the CO2 signal amplitude and phase, and the largest amplitude difference is ~2.1 times. When the H2O concentration is over 0.2%, the CO2 signal amplitude is saturated and remains steady. Atmospheric CO2 concentration is well measured using the optimal sensor parameters. Benefiting from the strong absorption line intensity at 4989.97 cm(-1), a detection limit of 19 ppm (1σ, 300 ms averaging time) is achieved, which corresponds to a normalized noise equivalent absorption coefficient of 4.71 × 10(-9) cm(-1) · W · Hz(-1/2).
- 19 November 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9274, 92741S
Application of pulse cavity ring-down spectroscopy technique for aerosol extinction measurement
In recent years, there has been a rapid rise in the use of pulse cavity ring-down spectroscopy to determine the optical properties of atmospheric aerosols. In the present work ,we describes the design and performance of a CRDS system for measuring extinction coefficients of atmospheric aerosols. CRDS based methods can achieve impressive sensitivity owing to the long effective path lengths involved. More importantly, the method is not affected by laser intensity fluctuations since the rate of attenuation of light is the measured variable rather than absolute irradiance. The extinction coefficient is a function of the cavity ring-down time. Determining an accurate decay time is critical to precise measurements of the extinction coefficients. The average and standard deviation of the decay time (τ0 is measured 6 hours ,cavity filled only with dry nitrogen) is about 42.21μs and 0.16μs, respectively. Moreover, a minimum detectable aerosol extinction coefficient of 0.41Mm-1 is achieved. Allan deviation plots for the value of τ0 measurements, close to a flicker noise. The minima(~5.8x10-4μs) in the Allan plots indicate the optimum average time(~60s) for optimum detection performance. To test the performance of the CRDS system, we monitored the optical properties of ambient aerosols on the campus of the Zhejiang Normal University from January 3rd to January 7th, 2014. During this period, the average value of the extinction coefficient is 816.8Mm-1, a maximum value more than 1800 Mm-1, and a minimum aerosol extinction coefficient of 119.27 Mm-1 is detected.
- 19 November 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9274, 92741S
Application of pulse cavity ring-down spectroscopy technique for aerosol extinction measurement
In recent years, there has been a rapid rise in the use of pulse cavity ring-down spectroscopy to determine the optical properties of atmospheric aerosols. In the present work ,we describes the design and performance of a CRDS system for measuring extinction coefficients of atmospheric aerosols. CRDS based methods can achieve impressive sensitivity owing to the long effective path lengths involved. More importantly, the method is not affected by laser intensity fluctuations since the rate of attenuation of light is the measured variable rather than absolute irradiance. The extinction coefficient is a function of the cavity ring-down time. Determining an accurate decay time is critical to precise measurements of the extinction coefficients. The average and standard deviation of the decay time (τ0 is measured 6 hours ,cavity filled only with dry nitrogen) is about 42.21μs and 0.16μs, respectively. Moreover, a minimum detectable aerosol extinction coefficient of 0.41Mm-1 is achieved. Allan deviation plots for the value of τ0 measurements, close to a flicker noise. The minima(~5.8x10-4μs) in the Allan plots indicate the optimum average time(~60s) for optimum detection performance. To test the performance of the CRDS system, we monitored the optical properties of ambient aerosols on the campus of the Zhejiang Normal University from January 3rd to January 7th, 2014. During this period, the average value of the extinction coefficient is 816.8Mm-1, a maximum value more than 1800 Mm-1, and a minimum aerosol extinction coefficient of 119.27 Mm-1 is detected.