Barry J. Gallacher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Barry J. Gallacher has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
J. S. Burdess
Newcastle University, Newcastle, Tyne and Waer NE1 7RU, United Kingdom
2 shared publications- Stephen R. Bowles
Newcastle University
2 shared publications Z. X. Hu
Newcastle University, Newcastle, Tyne and Waer NE1 7RU, United Kingdom
2 shared publicationsC. Dale
Newcastle University, Newcastle, Tyne and Waer NE1 7RU, United Kingdom
1 shared publicationC. Fu
Newcastle University, Newcastle, Tyne and Waer NE1 7RU, United Kingdom
1 shared publicationChristopher P. Fell
Atlantic Inertial Systems, Devon, U.K.
1 shared publication
Latest Publications
- Open Access
- 1 June 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 141 (6) , 4622-4632
The theory of a trapped degenerate mode resonator
Resonance based biosensors are used in the detection of biological molecules for medical diagnostics. Sensing in a liquid environment is very desirable for this application, but presents a significant challenge for resonators based upon conventional technologies. In this paper, the major originality lies in the development and exposition of a fundamental theory enabling design of an original elastic resonant sensor whose modes are engineered to simultaneously possess three separate but complementary dynamical properties: namely, (1) in-plane displacement of the free interface whereby the SH waves are uncoupled from the SV and P waves; (2) intrinsic modal trapping; and finally, (3) cyclic symmetry and modal degeneracy. The modal trapping is due to the physical configuration of the resonator resulting in an imaginary wavenumber for one region of the resonator. The wave will be evanescent in this region and propagating elsewhere. The fundamental principles are elucidated, and analytical techniques are presented that facilitate the efficient design of this unique class of device.
- 1 June 2017
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 141 (6) , 4622-4632
Open AccessThe theory of a trapped degenerate mode resonator
Resonance based biosensors are used in the detection of biological molecules for medical diagnostics. Sensing in a liquid environment is very desirable for this application, but presents a significant challenge for resonators based upon conventional technologies. In this paper, the major originality lies in the development and exposition of a fundamental theory enabling design of an original elastic resonant sensor whose modes are engineered to simultaneously possess three separate but complementary dynamical properties: namely, (1) in-plane displacement of the free interface whereby the SH waves are uncoupled from the SV and P waves; (2) intrinsic modal trapping; and finally, (3) cyclic symmetry and modal degeneracy. The modal trapping is due to the physical configuration of the resonator resulting in an imaginary wavenumber for one region of the resonator. The wave will be evanescent in this region and propagating elsewhere. The fundamental principles are elucidated, and analytical techniques are presented that facilitate the efficient design of this unique class of device.
- 29 September 2014
- Published by Springer Nature
- p. 473-492
The Application of Parametric Excitation in Resonant MEMS Gyroscopes
- 29 September 2014
- Published by Springer Nature
- p. 473-492
The Application of Parametric Excitation in Resonant MEMS Gyroscopes
- 14 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (1) , 552-560
Control Scheme to Reduce the Effect of Structural Imperfections in a Rate Integrating MEMS Gyroscope
In this paper, a control scheme is presented for a rate integrating microelectromechanical system ring gyroscope that reduces the effects of structural imperfections on the precession of an ellipse used to describe the structural vibration of the gyroscope. Modeling is provided that demonstrates the potential increase in gyroscope measurement accuracy on implementation of the control scheme. Furthermore, the description of the gyroscope dynamics used provides an alternative description of the effect of drive mistuning. Finally, experimental results are provided that demonstrate the viability of the proposed control scheme.
- 14 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (1) , 552-560
Control Scheme to Reduce the Effect of Structural Imperfections in a Rate Integrating MEMS Gyroscope
In this paper, a control scheme is presented for a rate integrating microelectromechanical system ring gyroscope that reduces the effects of structural imperfections on the precession of an ellipse used to describe the structural vibration of the gyroscope. Modeling is provided that demonstrates the potential increase in gyroscope measurement accuracy on implementation of the control scheme. Furthermore, the description of the gyroscope dynamics used provides an alternative description of the effect of drive mistuning. Finally, experimental results are provided that demonstrate the viability of the proposed control scheme.
- 1 January 2011
- Published by IMAPS - International Microelectronics Assembly and Packaging Society in Additional Conferences (Device Packaging, Hitec, Hiten, & Cicmt)
- Vol. 2011 (DPC) , 001342-001360
Fundamentals of a MEMS Rate Integrating Gyroscope that Exploits Wave Inertia
Most micromachined vibratory gyroscopes may be classified as “rate” gyroscopes where it is angular rate that is measured. Measurement of angle from a
- 1 January 2011
- Published by IMAPS - International Microelectronics Assembly and Packaging Society in Additional Conferences (Device Packaging, Hitec, Hiten, & Cicmt)
- Vol. 2011 (DPC) , 001342-001360
Fundamentals of a MEMS Rate Integrating Gyroscope that Exploits Wave Inertia
Most micromachined vibratory gyroscopes may be classified as “rate” gyroscopes where it is angular rate that is measured. Measurement of angle from a
- 1 January 2010
- Published by IMAPS - International Microelectronics Assembly and Packaging Society in Additional Conferences (Device Packaging, Hitec, Hiten, & Cicmt)
- Vol. 2010 (DPC) , 001322-001334
A Parametrically Amplified MEMS Gyroscope
The applicability of parametric amplification of either the primary and secondary vibration modes of a MEMS gyroscope, shown in Fig.1 is investigated experimentally in this paper. All control schemes have been implemented digitally onto a SHARC DSP development board. Parametric gains in excess of 80, which correspond to multiplication of the Q-factor by a factor of 80, are demonstrated experimentally for open-loop operation of the primary mode and are shown in Fig. 2. For open-loop operation it is shown that amplitude limiting nonlinearities become important as the vibration amplitude increases (see Figs.3) and that parametric amplification in excess of 80 can be only be achieved by further reducing the harmonic forcing amplitude. In many applications it is desirable to have as high a Q-factor as possible. The rate gyroscope is one application were active control of the Q-factor is extremely pertinent. If applied to the primary mode then it permits reduced forcing levels and hence contamination from “feedthrough”. If applied to the sense mode then the Coriolis force is effectively amplified. Parametric amplification of the secondary mode of the gyroscope is a challenging problem but it has the potential to improve the performance of MEMS rate gyroscope but an order of magnitude. In operation as a rate gyroscope it is important to maintain the amplitude of the primary mode of vibration at a constant level. For the case of a parametrically amplified primary mode the amplitude control circuit automatically adjusts the parametric excitation parameters to ensure the required parametric gain is achieved whilst at the same time reducing the amplitude of the harmonic forcing. In closed loop parametric amplification of the primary mode by a factor 20 have been demonstrated. Experimental results obtained from the amplified primary mode are shown in Fig.4.
- 1 January 2010
- Published by IMAPS - International Microelectronics Assembly and Packaging Society in Additional Conferences (Device Packaging, Hitec, Hiten, & Cicmt)
- Vol. 2010 (DPC) , 001322-001334
A Parametrically Amplified MEMS Gyroscope
The applicability of parametric amplification of either the primary and secondary vibration modes of a MEMS gyroscope, shown in Fig.1 is investigated experimentally in this paper. All control schemes have been implemented digitally onto a SHARC DSP development board. Parametric gains in excess of 80, which correspond to multiplication of the Q-factor by a factor of 80, are demonstrated experimentally for open-loop operation of the primary mode and are shown in Fig. 2. For open-loop operation it is shown that amplitude limiting nonlinearities become important as the vibration amplitude increases (see Figs.3) and that parametric amplification in excess of 80 can be only be achieved by further reducing the harmonic forcing amplitude. In many applications it is desirable to have as high a Q-factor as possible. The rate gyroscope is one application were active control of the Q-factor is extremely pertinent. If applied to the primary mode then it permits reduced forcing levels and hence contamination from “feedthrough”. If applied to the sense mode then the Coriolis force is effectively amplified. Parametric amplification of the secondary mode of the gyroscope is a challenging problem but it has the potential to improve the performance of MEMS rate gyroscope but an order of magnitude. In operation as a rate gyroscope it is important to maintain the amplitude of the primary mode of vibration at a constant level. For the case of a parametrically amplified primary mode the amplitude control circuit automatically adjusts the parametric excitation parameters to ensure the required parametric gain is achieved whilst at the same time reducing the amplitude of the harmonic forcing. In closed loop parametric amplification of the primary mode by a factor 20 have been demonstrated. Experimental results obtained from the amplified primary mode are shown in Fig.4.