Konstantinos Kazakos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Konstantinos Kazakos has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Athanasios Ververidis
Orthopaedic Department, Medical School, University General Hospital of Alexandroupolis, Democritus University of Thrace, St. Niarhos 1, Dragana, 68100, Alexandroupolis, Greece
3 shared publications - Georgios I. Drosos
Department of Orthopaedic Surgery, Medical School, Democritus University of Thrace, University General Hospital of Alexandroupolis, Alexandroupolis, Greece
3 shared publications - Alexandros Kouskoukis
Department of Nuclear Medicine, Democritus University of Thrace, University General Hospital of Alexandroupolis, Alexandroupolis, Greece
1 shared publication - Alexandros-Savvas Tselepis
Naval Hospital of Athens, Athens, Greece
1 shared publication - Athanasios N. Ververidis
Department of Orthopaedic Surgery, Medical School, Democritus University of Thrace, University General Hospital of Alexandroupolis, 68100, Alexandroupolis, Greece
1 shared publication - Athanasios Zissimopoulos
Department of Nuclear Medicine, School of Medicine, Democritus University of Thrace, 68100 Alexandroupolis, Greece
1 shared publication
Latest Publications
- 1 May 2015
- Vol. 26, 307-16
Constrained Implants in Total Knee Replacement.
Total knee replacement (TKR) is a successful procedure for pain relief and functional restoration in patients with advanced osteoarthritis. The number of TKRs is increasing, and this has led to an increase in revision surgeries. The key to long-term success in both primary and revision TKR is stability, as well as adequate and stable fixation between components and underlying bone. In the vast majority of primary TKRs and in some revision cases, a posterior cruciate retaining or a posterior cruciate substituting device can be used. In some primary cases with severe deformity or ligamentous instability and in most of the revision cases, a more constrained implant is required. The purpose of this paper is to review the literature concerning the use of condylar constrained knee (CCK) and rotating hinge (RH) implants in primary and revision cases focusing on the indications and results. According to this review, although excellent and very good results have been reported, there are limitations of the existing literature concerning the indications for the use of constrained implants, the absence of long-term results, and the limited comparative studies.
- 1 May 2015
- Vol. 26, 307-16
Constrained Implants in Total Knee Replacement.
Total knee replacement (TKR) is a successful procedure for pain relief and functional restoration in patients with advanced osteoarthritis. The number of TKRs is increasing, and this has led to an increase in revision surgeries. The key to long-term success in both primary and revision TKR is stability, as well as adequate and stable fixation between components and underlying bone. In the vast majority of primary TKRs and in some revision cases, a posterior cruciate retaining or a posterior cruciate substituting device can be used. In some primary cases with severe deformity or ligamentous instability and in most of the revision cases, a more constrained implant is required. The purpose of this paper is to review the literature concerning the use of condylar constrained knee (CCK) and rotating hinge (RH) implants in primary and revision cases focusing on the indications and results. According to this review, although excellent and very good results have been reported, there are limitations of the existing literature concerning the indications for the use of constrained implants, the absence of long-term results, and the limited comparative studies.
- Open Access
- 22 October 2014
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 16 (1) , 35-39
Vitamin D status in patients with knee or hip osteoarthritis in a Mediterranean country
Background Vitamin D plays an important role in bone mineralization, remodeling, and maintenance and therefore its deficiency may be implicated in the pathogenesis of osteoarthritis (OA). Vitamin D status was evaluated in patients with knee or hip OA scheduled for joint replacement. The impact of anthropometric parameters such as gender, age, and body mass index on vitamin D levels was also examined. The study was conducted in a Mediterranean country (Greece). Materials and methods We included 164 patients with knee or hip OA scheduled for joint replacement in this study. Serum levels of 25-hydroxyvitamin D (vitamin D) were measured in routine blood samples taken from the patients at their pre-admission visit, a week before the operation, using radioimmunoassay. Results The majority of patients were vitamin D deficient (81.7 %); 15.2 % of them were vitamin D insufficient (hypovitaminosis). Only 3 % of patients were vitamin D sufficient. There was a significantly positive association between vitamin D levels and male gender. Conclusion These findings indicate a large percentage of vitamin D deficient patients with knee or hip OA, which is unexpected considering the high annual insolation in northern Greece. Many other possible predisposing factors for OA should be taken into consideration. Whether treatment with vitamin D supplements may provide beneficial effects to these patients and the stage of disease in which this treatment should commence remains an issue for further scientific investigation. Level of evidence Level IV.
- 22 October 2014
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 16 (1) , 35-39
Open AccessVitamin D status in patients with knee or hip osteoarthritis in a Mediterranean country
Background Vitamin D plays an important role in bone mineralization, remodeling, and maintenance and therefore its deficiency may be implicated in the pathogenesis of osteoarthritis (OA). Vitamin D status was evaluated in patients with knee or hip OA scheduled for joint replacement. The impact of anthropometric parameters such as gender, age, and body mass index on vitamin D levels was also examined. The study was conducted in a Mediterranean country (Greece). Materials and methods We included 164 patients with knee or hip OA scheduled for joint replacement in this study. Serum levels of 25-hydroxyvitamin D (vitamin D) were measured in routine blood samples taken from the patients at their pre-admission visit, a week before the operation, using radioimmunoassay. Results The majority of patients were vitamin D deficient (81.7 %); 15.2 % of them were vitamin D insufficient (hypovitaminosis). Only 3 % of patients were vitamin D sufficient. There was a significantly positive association between vitamin D levels and male gender. Conclusion These findings indicate a large percentage of vitamin D deficient patients with knee or hip OA, which is unexpected considering the high annual insolation in northern Greece. Many other possible predisposing factors for OA should be taken into consideration. Whether treatment with vitamin D supplements may provide beneficial effects to these patients and the stage of disease in which this treatment should commence remains an issue for further scientific investigation. Level of evidence Level IV.
- 1 September 2013
- Vol. 23, 251-7
The silicone ring tourniquet in orthopaedic operations of the extremities.
Tourniquets provide a bloodless field in limb operations and their introduction in orthopaedic operative technique has been considered as a landmark. A new tourniquet device, a silicone ring tourniquet (SRT) (HemaClear or S-MART, OHK Medical Devices, Haifa, Israel), was introduced into clinical practice a few years ago. A few clinical studies as well as comparative studies in volunteers have reported its use in a relatively small number of cases. The aim of this prospective study is to report the clinical use of this device in a large number of patients, including all possible applications of a tourniquet. The SRT was used in 536 cases including 337 male and 119 female patients with a mean age of 43.7 years (range 6 to 87 years). The average tourniquet time was 58.5 minutes (range 6 to 180 minutes). It was applied in 362 (67.5%) elective and in 174 (32.5%) trauma cases including fractures (n:109, 62.6%) and soft-tissue injuries (n:65, 37.4%). The most frequent application site was the femur (n:255, 47.6%), followed by the forearm (n:154, 28.7%), humerus (n:65, 12.1%), and calf (n:62, 11.6%). Because the device is sterile it was possible to use it in operations in which the pneumatic tourniquet cannot be used, such as open reduction and internal fixation of humeral shaft and femoral supracondylar fractures. In 14 patients (2.6%), the tourniquet failed intraoperatively, and the cause was an unexpected raised blood pressure. The SRT - with a pre-set pressure according to the size and the tension model - is easy to apply. It is sterile, and occupies a narrow area of the limb. Its application combines three functions at the same time: exsanguination, tourniquet, and stockinet application. Although it cannot entirely replace the classic pneumatic tourniquet, it is a safe and useful device in orthopaedic operations because of its advantages.
- 1 September 2013
- Vol. 23, 251-7
The silicone ring tourniquet in orthopaedic operations of the extremities.
Tourniquets provide a bloodless field in limb operations and their introduction in orthopaedic operative technique has been considered as a landmark. A new tourniquet device, a silicone ring tourniquet (SRT) (HemaClear or S-MART, OHK Medical Devices, Haifa, Israel), was introduced into clinical practice a few years ago. A few clinical studies as well as comparative studies in volunteers have reported its use in a relatively small number of cases. The aim of this prospective study is to report the clinical use of this device in a large number of patients, including all possible applications of a tourniquet. The SRT was used in 536 cases including 337 male and 119 female patients with a mean age of 43.7 years (range 6 to 87 years). The average tourniquet time was 58.5 minutes (range 6 to 180 minutes). It was applied in 362 (67.5%) elective and in 174 (32.5%) trauma cases including fractures (n:109, 62.6%) and soft-tissue injuries (n:65, 37.4%). The most frequent application site was the femur (n:255, 47.6%), followed by the forearm (n:154, 28.7%), humerus (n:65, 12.1%), and calf (n:62, 11.6%). Because the device is sterile it was possible to use it in operations in which the pneumatic tourniquet cannot be used, such as open reduction and internal fixation of humeral shaft and femoral supracondylar fractures. In 14 patients (2.6%), the tourniquet failed intraoperatively, and the cause was an unexpected raised blood pressure. The SRT - with a pre-set pressure according to the size and the tension model - is easy to apply. It is sterile, and occupies a narrow area of the limb. Its application combines three functions at the same time: exsanguination, tourniquet, and stockinet application. Although it cannot entirely replace the classic pneumatic tourniquet, it is a safe and useful device in orthopaedic operations because of its advantages.
- 30 June 2008
- Published by Elsevier in The Spine Journal
- Vol. 8 (3) , 552-554
Neglected Hangman's fracture in association with rupture of the trachea
- 30 June 2008
- Published by Elsevier in The Spine Journal
- Vol. 8 (3) , 552-554
Neglected Hangman's fracture in association with rupture of the trachea