Huiming Zou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Huiming Zou has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Dariusz Butrymowicz
Department of Thermal Engineering, Bialystok University of Technology, 15-351 Bialystok, Poland
4 shared publications - Kamil Śmierciew
Department of Thermal Engineering, Bialystok University of Technology, 15-351 Bialystok, Poland
4 shared publications Shuo Zhang
4 shared publicationsChangqing Tian
3 shared publicationsMingsheng Tang
3 shared publications- Adam Dudar
Department of Thermal Engineering , Faculty of Mechanical Engineering, Bialystok University of Technology , Wiejska 45C, 15-351 , Bialystok , Poland
2 shared publications
Latest Publications
- 2 April 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 175, 146-155
Study of optimizing the secondary cylinder size in a novel dual-piston carbon dioxide linear compressor to suppress piston offset
- 2 April 2025
- Published by Elsevier in International Journal of Refrigeration
- Vol. 175, 146-155
Study of optimizing the secondary cylinder size in a novel dual-piston carbon dioxide linear compressor to suppress piston offset
- Open Access
Experimental Investigation of Bacterial Inactivation of Beef Using Indirect Cold Plasma in Cold Chain and at Room Temperature
Pathogen contamination is a severe problem in maintaining food safety in the cold chain. Cold plasma (CP) is a novel non-thermal disinfection method that can be applied for the bacterial inactivation of food in appropriate contexts. Currently, research on CP used on food at cold chain temperatures is rare. This work investigated the bacterial inactivation effect of CP on beef at typical cold storage temperatures of 4 and −18 °C and room temperature (25 °C). The reactive species in CP were indirectly tested by evaluating O3, NO3− and NO2− in cold plasma-activated water (PAW), which indicated the highest concentrations of reactive species in CP at 25 °C and the lowest at −18 °C. The bactericidal efficacy of CP treatment against beef inoculated with Escherichia coli at −18 °C, 4 °C, and 25 °C was 30.5%, 60.1%, and 59.5%, respectively. The 4 °C environment was the most appropriate treatment for CP against beef, with the highest bactericidal efficacy and a minor influence on beef quality. The indirect CP treatment had no significant effect on the texture, color, pH, or cooking loss of beef at −18 °C. CP shows significant potential for the efficient decontamination of food at cold chain temperatures.
Open AccessExperimental Investigation of Bacterial Inactivation of Beef Using Indirect Cold Plasma in Cold Chain and at Room Temperature
Pathogen contamination is a severe problem in maintaining food safety in the cold chain. Cold plasma (CP) is a novel non-thermal disinfection method that can be applied for the bacterial inactivation of food in appropriate contexts. Currently, research on CP used on food at cold chain temperatures is rare. This work investigated the bacterial inactivation effect of CP on beef at typical cold storage temperatures of 4 and −18 °C and room temperature (25 °C). The reactive species in CP were indirectly tested by evaluating O3, NO3− and NO2− in cold plasma-activated water (PAW), which indicated the highest concentrations of reactive species in CP at 25 °C and the lowest at −18 °C. The bactericidal efficacy of CP treatment against beef inoculated with Escherichia coli at −18 °C, 4 °C, and 25 °C was 30.5%, 60.1%, and 59.5%, respectively. The 4 °C environment was the most appropriate treatment for CP against beef, with the highest bactericidal efficacy and a minor influence on beef quality. The indirect CP treatment had no significant effect on the texture, color, pH, or cooking loss of beef at −18 °C. CP shows significant potential for the efficient decontamination of food at cold chain temperatures.
- 5 September 2024
- Published by Springer Nature in Science China Technological Sciences
- Vol. 67 (12) , 3673-3681
Performance analysis of an R290 vapor-injection heat pump system for electric vehicles in cold regions
- 5 September 2024
- Published by Springer Nature in Science China Technological Sciences
- Vol. 67 (12) , 3673-3681
Performance analysis of an R290 vapor-injection heat pump system for electric vehicles in cold regions
- Open Access
- 28 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (7) , 5853
Experimental Analysis of the Discharge Valve Movement of the Oil-Free Linear Compressor in the Refrigeration System
In a linear compressor, the valve motion significantly affects the thermodynamic efficiency and the compressor’s reliability, especially in oil-free conditions. To better understand the dynamic behavior of the discharge valve, a real-time test bench was built. The piston movements and dynamic pressure in the cylinder were also observed to obtain the synchronizing characteristics among the reed valve motion, cylinder pressure, and piston motion. Observing the motion of the discharge valve visually, the discharge valve flutters due to the change in the form of the cylinder pressure, the delayed opening of the valve is caused by the inertia of the valve itself, and additional displacement fluctuations are present. This paper presents the dynamic behavior of the discharge valve under different discharge pressure/operating frequency/piston stroke/clearance length conditions. The results show that the valve flutters increase, the mean displacement of the valve increases, and the duration of the discharge increases when the discharge pressure decreases. When the operating frequency increases, the duration of the discharge decreases, while the mean displacement of the valve increases. For a high stroke or a low clearance length case, the duration of the discharge increases, while the valve flutters increase due to the pressure fluctuations in the cylinder. Through analyzing the synchronizing characteristic among the valve movements, piston movements, and cylinder pressure, it is shown that the phenomenon of the delayed opening valve is much worse for a low stroke or a high operating frequency case. In addition, the delayed closing of the valve appears for a high operating frequency case (75 Hz).
- 28 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (7) , 5853
Open AccessExperimental Analysis of the Discharge Valve Movement of the Oil-Free Linear Compressor in the Refrigeration System
In a linear compressor, the valve motion significantly affects the thermodynamic efficiency and the compressor’s reliability, especially in oil-free conditions. To better understand the dynamic behavior of the discharge valve, a real-time test bench was built. The piston movements and dynamic pressure in the cylinder were also observed to obtain the synchronizing characteristics among the reed valve motion, cylinder pressure, and piston motion. Observing the motion of the discharge valve visually, the discharge valve flutters due to the change in the form of the cylinder pressure, the delayed opening of the valve is caused by the inertia of the valve itself, and additional displacement fluctuations are present. This paper presents the dynamic behavior of the discharge valve under different discharge pressure/operating frequency/piston stroke/clearance length conditions. The results show that the valve flutters increase, the mean displacement of the valve increases, and the duration of the discharge increases when the discharge pressure decreases. When the operating frequency increases, the duration of the discharge decreases, while the mean displacement of the valve increases. For a high stroke or a low clearance length case, the duration of the discharge increases, while the valve flutters increase due to the pressure fluctuations in the cylinder. Through analyzing the synchronizing characteristic among the valve movements, piston movements, and cylinder pressure, it is shown that the phenomenon of the delayed opening valve is much worse for a low stroke or a high operating frequency case. In addition, the delayed closing of the valve appears for a high operating frequency case (75 Hz).
- Open Access
- 1 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 14249
Investigations of Performance of Mini-Channel Condensers and Evaporators for Propane
This paper provides the results of experimental investigations of the exemplary mini-channel heat exchanger in its application as a condenser and an evaporator in a compressor refrigeration system with propane as a working fluid. The aim of the investigations was to identify the mean heat transfer coefficient of the refrigerant side for the entire operating range of the tested heat exchanger. The experiments covered a mass velocity range from 50 to 160 kg/(m2 × s). The experiments covered a range of liquid subcooling in the condenser from 3 to 15 K and a range of vapour superheating at the outlet of the evaporator from 3 up to 15 K. The experiments on the condenser were conducted at the saturation temperature of 34 °C, and in the case of the evaporator, at the saturation temperature of 8 °C. The average heat transfer coefficients as well as pressure drops in the case of the operation of the tested heat exchanger as an evaporator and condenser were calculated. The heat transfer coefficient was calculated by means of the separated thermal resistance method with the application of the Wilson plot technique. The experiments confirmed the increase in the heat transfer coefficient with the increase in the refrigerant mass flow rate for the tested mini-channel heat exchanger. A dimensionless correlation was proposed for the pressure drop based on the modified Müller-Steinhagen correlation in the case of the operation of the mini-channel heat exchanger as a condenser and as an evaporator.
- 1 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (21) , 14249
Open AccessInvestigations of Performance of Mini-Channel Condensers and Evaporators for Propane
This paper provides the results of experimental investigations of the exemplary mini-channel heat exchanger in its application as a condenser and an evaporator in a compressor refrigeration system with propane as a working fluid. The aim of the investigations was to identify the mean heat transfer coefficient of the refrigerant side for the entire operating range of the tested heat exchanger. The experiments covered a mass velocity range from 50 to 160 kg/(m2 × s). The experiments covered a range of liquid subcooling in the condenser from 3 to 15 K and a range of vapour superheating at the outlet of the evaporator from 3 up to 15 K. The experiments on the condenser were conducted at the saturation temperature of 34 °C, and in the case of the evaporator, at the saturation temperature of 8 °C. The average heat transfer coefficients as well as pressure drops in the case of the operation of the tested heat exchanger as an evaporator and condenser were calculated. The heat transfer coefficient was calculated by means of the separated thermal resistance method with the application of the Wilson plot technique. The experiments confirmed the increase in the heat transfer coefficient with the increase in the refrigerant mass flow rate for the tested mini-channel heat exchanger. A dimensionless correlation was proposed for the pressure drop based on the modified Müller-Steinhagen correlation in the case of the operation of the mini-channel heat exchanger as a condenser and as an evaporator.
- Open Access
- 17 October 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (20) , 13356
Experimental Assessment of the Efficiency of Two-Phase Ejector Components for Isobutane
Two-phase ejectors as well as single phase ejectors can be applied in many branches of industry: refrigeration and heat pump systems, chemical engineering, food processing, and others. Due to the complicated nature of the process of momentum transfer in two-phase ejectors, their design procedure based on the accurate theoretical prediction of the ejector performance is still an open issue. The paper provides its own experimental results of the velocity coefficients of the components of the two-phase ejector, i.e., the motive nozzle, suction chamber, mixing chamber, and diffuser. The results were obtained in the case of isobutane as the working fluid. It was demonstrated that the velocity coefficients may not be treated as constant quantities. Therefore, our own proposed dimensionless relationships describe the velocity coefficients of the components of the ejector that may be applied in the design procedure of the ejector. The two physical parameters, the wet vapour quality and the volumetric entrainment ratio, were selected as the key parameters. In addition, the aspects of the prediction of the critical mass flow rate of the motive nozzles was considered on the basis of the Henry–Fauske model. It was demonstrated that the model accurately predicts the two-phase critical flow under the conditions of a higher range of wet vapour quality.
- 17 October 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (20) , 13356
Open AccessExperimental Assessment of the Efficiency of Two-Phase Ejector Components for Isobutane
Two-phase ejectors as well as single phase ejectors can be applied in many branches of industry: refrigeration and heat pump systems, chemical engineering, food processing, and others. Due to the complicated nature of the process of momentum transfer in two-phase ejectors, their design procedure based on the accurate theoretical prediction of the ejector performance is still an open issue. The paper provides its own experimental results of the velocity coefficients of the components of the two-phase ejector, i.e., the motive nozzle, suction chamber, mixing chamber, and diffuser. The results were obtained in the case of isobutane as the working fluid. It was demonstrated that the velocity coefficients may not be treated as constant quantities. Therefore, our own proposed dimensionless relationships describe the velocity coefficients of the components of the ejector that may be applied in the design procedure of the ejector. The two physical parameters, the wet vapour quality and the volumetric entrainment ratio, were selected as the key parameters. In addition, the aspects of the prediction of the critical mass flow rate of the motive nozzles was considered on the basis of the Henry–Fauske model. It was demonstrated that the model accurately predicts the two-phase critical flow under the conditions of a higher range of wet vapour quality.