Pedatsur Neta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pedatsur Neta has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Steen Steenken
Max-Planck-Institut für Strahlenchemie, Mülheim, Germany
3 shared publications - Andrzej Skrzypczak
Faculty of Chemical Technology, Poznan University of Technology, Poznan, Poland
1 shared publication B. L. Milman
Physical and Chemical Properties Division, National Institute of Standards and Technology, Gaithersburg, USA
1 shared publicationMahnaz Farahani
Biomolecular Measurement Division National Institute of Standards and Technology Gaithersburg MD 20899 USA
1 shared publicationR. E. Huie
Physical and Chemical Properties Division, National Institute of Standards and Technology, Gaithersburg, USA
1 shared publicationStephen E. Stein
Biomolecular Measurement Division National Institute of Standards and Technology Gaithersburg MD 20899 USA
1 shared publication
Latest Publications
- 23 October 2014
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 28 (23) , 2645-2660
Unexpected peaks in tandem mass spectra due to reaction of product ions with residual water in mass spectrometer collision cells
RATIONALE: Certain product ions in electrospray ionization tandem mass spectrometry are found to react with residual water in the collision cell. This reaction often leads to the formation of ions that cannot be formed directly from the precursor ions, and this complicates the mass spectra and may distort MRM (multiple reaction monitoring) results. METHODS: Various drugs, pesticides, metabolites, and other compounds were dissolved in acetonitrile/water/formic acid and studied by electrospray ionization mass spectrometry to record their MS 2 and MS n spectra in several mass spectrometers (QqQ, QTOF, IT, and Orbitrap HCD). Certain product ions were found to react with residual water in collision cells. The reaction was confirmed by MS n studies and the rate of reaction was determined in the IT instrument using zero collision energy and variable activation times. RESULTS: Examples of product ions reacting with water include phenyl and certain substituted phenyl cations, benzoyl‐type cations formed from protonated folic acid and similar compounds by loss of the glutamate moiety, product ions formed from protonated cyclic siloxanes by loss of methane, product ions formed from organic phosphates, and certain negative ions. The reactions of product ions with residual water varied greatly in their rate constant and in the extent of reaction (due to isomerization). CONCLUSIONS: Various types of product ions react with residual water in mass spectrometer collision cells. As a result, tandem mass spectra may contain unexplained peaks and MRM results may be distorted by the occurrence of such reactions. These often unavoidable reactions must be taken into account when annotating peaks in tandem mass spectra and when interpreting MRM results. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.
- 23 October 2014
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 28 (23) , 2645-2660
Unexpected peaks in tandem mass spectra due to reaction of product ions with residual water in mass spectrometer collision cells
RATIONALE: Certain product ions in electrospray ionization tandem mass spectrometry are found to react with residual water in the collision cell. This reaction often leads to the formation of ions that cannot be formed directly from the precursor ions, and this complicates the mass spectra and may distort MRM (multiple reaction monitoring) results. METHODS: Various drugs, pesticides, metabolites, and other compounds were dissolved in acetonitrile/water/formic acid and studied by electrospray ionization mass spectrometry to record their MS 2 and MS n spectra in several mass spectrometers (QqQ, QTOF, IT, and Orbitrap HCD). Certain product ions were found to react with residual water in collision cells. The reaction was confirmed by MS n studies and the rate of reaction was determined in the IT instrument using zero collision energy and variable activation times. RESULTS: Examples of product ions reacting with water include phenyl and certain substituted phenyl cations, benzoyl‐type cations formed from protonated folic acid and similar compounds by loss of the glutamate moiety, product ions formed from protonated cyclic siloxanes by loss of methane, product ions formed from organic phosphates, and certain negative ions. The reactions of product ions with residual water varied greatly in their rate constant and in the extent of reaction (due to isomerization). CONCLUSIONS: Various types of product ions react with residual water in mass spectrometer collision cells. As a result, tandem mass spectra may contain unexplained peaks and MRM results may be distorted by the occurrence of such reactions. These often unavoidable reactions must be taken into account when annotating peaks in tandem mass spectra and when interpreting MRM results. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.
- 15 December 2009
- Published by Wiley
Transient Phenoxyl Radicals: Formation and Properties in Aqueous Solutions
Introduction: Formation of Phenoxyl Radicals: Properties of Phenoxyl Radicals:
- 15 December 2009
- Published by Wiley
Transient Phenoxyl Radicals: Formation and Properties in Aqueous Solutions
Introduction: Formation of Phenoxyl Radicals: Properties of Phenoxyl Radicals:
- 15 December 2009
- Published by Wiley
Radiation Chemistry of Phenols
Introduction: Radiation Chemistry of Phenols in Aqueous Solutions: Radiation Chemistry of Phenols in Organic Solvents: Radiation Chemistry of Neat Phenols (and in Solid Matrices): Radiation Chemistry of Phenols in the Gas Phase:
- 15 December 2009
- Published by Wiley
Radiation Chemistry of Phenols
Introduction: Radiation Chemistry of Phenols in Aqueous Solutions: Radiation Chemistry of Phenols in Organic Solvents: Radiation Chemistry of Neat Phenols (and in Solid Matrices): Radiation Chemistry of Phenols in the Gas Phase:
- 4 February 2004
- Published by Wiley in International Journal of Chemical Kinetics
- Vol. 36 (4) , 253-258
Rate constants for reaction of 1,2‐dimethylimidazole with benzyl bromide in ionic liquids and organic solvents
The rate constant for the Menschutkin reaction of 1,2‐dimethylimidazole with benzyl bromide to produce 3‐benzyl‐1,2‐dimethylimidazolium bromide was determined in a number of ionic liquids and molecular organic solvents. The rate constants in 12 ionic liquids are in the range of (1.0–3.2) × 10−3 L mol−1 s−1 and vary with the solvent anion in the order (CF3SO2)2 N− < PF6− < BF4−. Variations with the solvent cation (butylmethylimidazolium, octylmethylimidazolium, butyldimethylimidazolium, octyldimethylimidazolium, butylmethylpyrrolidinium, and hexyltributylammonium) are minimal. The rate constants in the ionic liquids are comparable to those in polar aprotic molecular solvents (acetonitrile, propylene carbonate) but much higher than those in weakly polar organic solvents and in alcohols. Correlation of the rate constants with the solvatochromic parameter ET(30) is reasonable within each group of similar solvents but very poor when all the solvents are correlated together. Better correlation is obtained for the organic solvents by using a combination of two parameters, π* (dipolarity/polarizibility) and α (hydrogen bond acidity), while additional parameters such as δ (cohesive energy density) do not provide any further improvement. © 2004 Wiley Periodicals, Inc.* This article is a US Government work and, as such, is in the public domain of the United States of America. Int J Chem Kinet 36: 253–258, 2004
- 4 February 2004
- Published by Wiley in International Journal of Chemical Kinetics
- Vol. 36 (4) , 253-258
Rate constants for reaction of 1,2‐dimethylimidazole with benzyl bromide in ionic liquids and organic solvents
The rate constant for the Menschutkin reaction of 1,2‐dimethylimidazole with benzyl bromide to produce 3‐benzyl‐1,2‐dimethylimidazolium bromide was determined in a number of ionic liquids and molecular organic solvents. The rate constants in 12 ionic liquids are in the range of (1.0–3.2) × 10−3 L mol−1 s−1 and vary with the solvent anion in the order (CF3SO2)2 N− < PF6− < BF4−. Variations with the solvent cation (butylmethylimidazolium, octylmethylimidazolium, butyldimethylimidazolium, octyldimethylimidazolium, butylmethylpyrrolidinium, and hexyltributylammonium) are minimal. The rate constants in the ionic liquids are comparable to those in polar aprotic molecular solvents (acetonitrile, propylene carbonate) but much higher than those in weakly polar organic solvents and in alcohols. Correlation of the rate constants with the solvatochromic parameter ET(30) is reasonable within each group of similar solvents but very poor when all the solvents are correlated together. Better correlation is obtained for the organic solvents by using a combination of two parameters, π* (dipolarity/polarizibility) and α (hydrogen bond acidity), while additional parameters such as δ (cohesive energy density) do not provide any further improvement. © 2004 Wiley Periodicals, Inc.* This article is a US Government work and, as such, is in the public domain of the United States of America. Int J Chem Kinet 36: 253–258, 2004
- 1 September 2003
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 377 (1) , 159-164
Electrospray ionization mass spectrometry of ionic liquids and determination of their solubility in water
Electrospray ionization mass spectrometry is used to detect both the cations (C+) and the anions (A−) of ionic liquids (CA). In this study, the ionic liquids are diluted with aqueous methanol before injection. In addition to the main peaks of the parent ions, fragmentation products are observed upon increasing the cone voltage, whereas aggregates of the parent ion with one or more ionic liquid molecules (e.g., C(CA)n +, A(CA)n −) are observed upon decreasing the cone voltage. The ions of several ionic liquids in a mixture are also detected and the ratios of their concentrations estimated. A method is developed to determine quantitatively the concentration of an ionic liquid in solution by using the cation and anion of another ionic liquid as internal standards. By using this method, the solubilities in water at room temperature (22±1 °C) of three typical hydrophobic ionic liquids have been determined: 0.70±0.08 g L−1 for methyltributylammonium bis(trifluoromethylsulfonyl)imide (MeBu3NNTf2), 6.0±0.5 g L−1 for butylmethylpyrrolidinium bis(trifluoromethylsulfonyl)imide (BuMePyrNTf2), and 18.6±0.7 g L−1 for 1-butyl-3-methylimidazolium hexafluorophosphate (BMIPF6).
- 1 September 2003
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 377 (1) , 159-164
Electrospray ionization mass spectrometry of ionic liquids and determination of their solubility in water
Electrospray ionization mass spectrometry is used to detect both the cations (C+) and the anions (A−) of ionic liquids (CA). In this study, the ionic liquids are diluted with aqueous methanol before injection. In addition to the main peaks of the parent ions, fragmentation products are observed upon increasing the cone voltage, whereas aggregates of the parent ion with one or more ionic liquid molecules (e.g., C(CA)n +, A(CA)n −) are observed upon decreasing the cone voltage. The ions of several ionic liquids in a mixture are also detected and the ratios of their concentrations estimated. A method is developed to determine quantitatively the concentration of an ionic liquid in solution by using the cation and anion of another ionic liquid as internal standards. By using this method, the solubilities in water at room temperature (22±1 °C) of three typical hydrophobic ionic liquids have been determined: 0.70±0.08 g L−1 for methyltributylammonium bis(trifluoromethylsulfonyl)imide (MeBu3NNTf2), 6.0±0.5 g L−1 for butylmethylpyrrolidinium bis(trifluoromethylsulfonyl)imide (BuMePyrNTf2), and 18.6±0.7 g L−1 for 1-butyl-3-methylimidazolium hexafluorophosphate (BMIPF6).
- 22 July 2003
- Published by Wiley
- p. 1107-1152
Transient Phenoxyl Radicals: Formation and Properties in Aqueous Solutions
- 22 July 2003
- Published by Wiley
- p. 1107-1152
Transient Phenoxyl Radicals: Formation and Properties in Aqueous Solutions