Yuichi Murozaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuichi Murozaki has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Fumihito Arai
Nagoya University
4 shared publications- Fumihito Arai
The University of Tokyo
1 shared publication Shinya Sakuma
Nagoya University
1 shared publication- Shinya Sakuma
Nagoya University
1 shared publication - Shinya Sakuma
Department of Mechanical Engineering, Faculty of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, Fukuoka 819-0395, Japan
1 shared publication
Latest Publications
- Open Access
Improvement of the Measurement Range and Temperature Characteristics of a Load Sensor Using a Quartz Crystal Resonator with All Crystal Layer Components
Monitoring multiple biosignals, such as heart rate, respiration cycle, and weight transitions, contributes to the health management of individuals. Specifically, it is possible to measure multiple biosignals using load information obtained through contact with the environment, such as a chair and bed, in daily use. A wide-range load sensor is essential since load information contains multiple biosignals with various load ranges. In this study, a load sensor is presented by using a quartz crystal resonator (QCR) with a wide measurement range of 1.5 × 106 (0.4 mN to 600 N), and its temperature characteristic of load is improved to −7 Hz/°C (−18 mN/°C). In order to improve the measurement range of the load, a design method of this sensor is proposed by restraining the buckling of QCR and by using a thinner QCR. The proposed sensor allows a higher allowable load with high sensitivity. The load sensor mainly consists of three layers, namely a QCR layer and two holding layers. As opposed to the conventional holding layer composed of silicon, quartz crystal is utilized for the holding layers to improve the temperature characteristic of the load sensor. In the study, multiple biosignals, such as weight and pulse, are detected by using a fabricated sensor.
Open AccessImprovement of the Measurement Range and Temperature Characteristics of a Load Sensor Using a Quartz Crystal Resonator with All Crystal Layer Components
Monitoring multiple biosignals, such as heart rate, respiration cycle, and weight transitions, contributes to the health management of individuals. Specifically, it is possible to measure multiple biosignals using load information obtained through contact with the environment, such as a chair and bed, in daily use. A wide-range load sensor is essential since load information contains multiple biosignals with various load ranges. In this study, a load sensor is presented by using a quartz crystal resonator (QCR) with a wide measurement range of 1.5 × 106 (0.4 mN to 600 N), and its temperature characteristic of load is improved to −7 Hz/°C (−18 mN/°C). In order to improve the measurement range of the load, a design method of this sensor is proposed by restraining the buckling of QCR and by using a thinner QCR. The proposed sensor allows a higher allowable load with high sensitivity. The load sensor mainly consists of three layers, namely a QCR layer and two holding layers. As opposed to the conventional holding layer composed of silicon, quartz crystal is utilized for the holding layers to improve the temperature characteristic of the load sensor. In the study, multiple biosignals, such as weight and pulse, are detected by using a fabricated sensor.
- Open Access
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2016, 1P1-18b4
QCR Load Sensor with Measurement Range of 106
Monitoring of biosignals plays important role in health and safe management in daily life. We have developed wide range load sensor based quartz crystal resonator (QCR load sensor) for casual sensing of biosignals such as pulse, respiration, and body motion. Expansion of the measurement range of the sensor is required for enhancing the usage of the QCR load sensor as casual sensing. We described the design of QCR load sensor to expand the measurement range of the QCR load sensor. Fabricated sensor with proposed design had practical resolution of 0.4 mN and maximum allowable load of 600 N, so that we successfully enhanced the measurement range of the QCR load sensor to 1.5 x 106.
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2016, 1P1-18b4
Open AccessQCR Load Sensor with Measurement Range of 106
Monitoring of biosignals plays important role in health and safe management in daily life. We have developed wide range load sensor based quartz crystal resonator (QCR load sensor) for casual sensing of biosignals such as pulse, respiration, and body motion. Expansion of the measurement range of the sensor is required for enhancing the usage of the QCR load sensor as casual sensing. We described the design of QCR load sensor to expand the measurement range of the QCR load sensor. Fabricated sensor with proposed design had practical resolution of 0.4 mN and maximum allowable load of 600 N, so that we successfully enhanced the measurement range of the QCR load sensor to 1.5 x 106.
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2014, _1P2-X02_1
1P2-X02 High-sensitive and Wide-range Load Sensor Using Micro Retention Mechanism of Quartz Crystal Resonator(Tactile and Force Sensing (2))
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2014, _1P2-X02_1
1P2-X02 High-sensitive and Wide-range Load Sensor Using Micro Retention Mechanism of Quartz Crystal Resonator(Tactile and Force Sensing (2))
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2014, _1P1-X03_1
1P1-X03 Multiple Biosignals Detection by Wide-range Load Sensor Using Quartz Crystal Resonator(Tactile and Force Sensing (1))
Highly sensitive, wide-measurement-range compact load sensors are desirable for various applications. A load sensor using an AT-cut quartz crystal resonator (QCR) has superior characteristics such as, high accuracy, improved strength under compressive stress, long-term stability. However, a retention mechanism is required to firmly support the QCR because the QCR is easily broken by stretching and bending motions. Conventional machining processes are not suitable for further miniaturization of the sensor. Even if the retention mechanism were miniaturized, the assembly process is complicated. We proposed a μQCR load sensor that fabricated by microfabrication and bonding for simplifying assembly process. The objective of this study is to improve the maximum load and load-measurement resolution of the sensor for application to biological signal detection in the bed. We fabricated a μQCR sensor with a sensitivity of 374 Hz/N (theoretical maximum load is 130 N) and succeeded in detecting multiple biological signals (respiration, heartbeat, and posture).
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2014, _1P1-X03_1
1P1-X03 Multiple Biosignals Detection by Wide-range Load Sensor Using Quartz Crystal Resonator(Tactile and Force Sensing (1))
Highly sensitive, wide-measurement-range compact load sensors are desirable for various applications. A load sensor using an AT-cut quartz crystal resonator (QCR) has superior characteristics such as, high accuracy, improved strength under compressive stress, long-term stability. However, a retention mechanism is required to firmly support the QCR because the QCR is easily broken by stretching and bending motions. Conventional machining processes are not suitable for further miniaturization of the sensor. Even if the retention mechanism were miniaturized, the assembly process is complicated. We proposed a μQCR load sensor that fabricated by microfabrication and bonding for simplifying assembly process. The objective of this study is to improve the maximum load and load-measurement resolution of the sensor for application to biological signal detection in the bed. We fabricated a μQCR sensor with a sensitivity of 374 Hz/N (theoretical maximum load is 130 N) and succeeded in detecting multiple biological signals (respiration, heartbeat, and posture).
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Symposium on Micro-Nano Science and Technology
- Vol. 2014.6, _21am2-A5
21am2-A5 Miniaturization of QCR load sensor using microfabrication
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Symposium on Micro-Nano Science and Technology
- Vol. 2014.6, _21am2-A5
21am2-A5 Miniaturization of QCR load sensor using microfabrication