M. Hafez A. Alhous
M. Hafez A. Alhous has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Andrew Hannah
Department of Cardiology, Aberdeen Royal Infirmary/University of Aberdeen, Aberdeen AB25 2ZN, UK
2 shared publicationsGary R. Small
Department of Cardiology, Aberdeen Royal Infirmary/University of Aberdeen, Aberdeen AB25 2ZN, UK
2 shared publicationsGraham S. Hillis
The George Institute for Global Health, University of Sydney, Australia
2 shared publicationsMichael Frenneaux
Department of Cardiology, Aberdeen Royal Infirmary/University of Aberdeen, Aberdeen AB25 2ZN, UK
1 shared publicationPaul A. Broadhurst
Department of Cardiology, Aberdeen Royal Infirmary/University of Aberdeen, Aberdeen AB25 2ZN, UK
1 shared publicationPaul Broadhurst
Department of Cardiology , Aberdeen Royal Infirmary/University of Aberdeen , Aberdeen , UK
1 shared publication
Latest Publications
- Open Access
- 30 October 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 17 (1) , 94-100
Right ventricular septal pacing as alternative for failed left ventricular lead implantation in cardiac resynchronization therapy candidates
To compare the effects on left ventricular (LV) function of right ventricular (RV) septal pacing vs. cardiac resynchronization therapy (CRT) in patients with an indication for the latter. Cardiac resynchronization therapy is an effective therapy in patients with drug-refractory heart failure. Despite advances in implantation techniques, LV lead placement can be impossible in up to 10% of cases. We, therefore, assessed the effects of RV septal pacing from mid septum (RVmIVS) and outflow tract (RVOT) on cardiac performance, in comparison with CRT. Twenty-two patients scheduled for CRT underwent dual-chamber temporary pacing. The ventricular lead was placed at the RV apex (RVA), RVmIVS, and RVOT in random order. Comprehensive echocardiography was performed in a baseline AAI mode and then at each RV position in dual chamber pacemaker function (D pacing, D sensing, D dual responses) mode and repeated on the next day following CRT implantation. Right ventricular apex pacing did not change any of the assessed echocardiography parameters. Both RVmIVS and RVOT pacing increased LV ejection fraction (EF): 29 ± 7% at baseline vs. 32 ± 6% (P = 0.02) and 32 ± 5% (P = 0.04) with RVmIVS and RVOT pacing, respectively. Similarly, the dyssynchrony index (Ts-SD) decreased: 50 ± 19 ms at baseline vs. 39 ± 17 ms (P = 0.04) and 37 ± 17 ms (P = 0.006) with RVmIVS and RVOT pacing, respectively. Cardiac resynchronization therapy further improved LVEF and Ts-SD to 36 ± 7% and 34 ± 15 ms, respectively, however, only LVEF was significantly higher compared with RVmIVS and RVOT pacing (P = 0.03 and P = 0.01 respectively). There were no significant differences in either LVEF or Ts-SD between RVmIVS and RVOT. Right ventricular septal pacing from mid septum or RVOT pacing improves LVEF and LV synchrony in CRT candidates. Further improvement in LVEF was achieved by CRT, which remains the ‘gold standard’ therapy in these patients. However, RV septal pacing is worthy of further study as an alternative strategy when LV lead implantation fails.
- 30 October 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 17 (1) , 94-100
Open AccessRight ventricular septal pacing as alternative for failed left ventricular lead implantation in cardiac resynchronization therapy candidates
To compare the effects on left ventricular (LV) function of right ventricular (RV) septal pacing vs. cardiac resynchronization therapy (CRT) in patients with an indication for the latter. Cardiac resynchronization therapy is an effective therapy in patients with drug-refractory heart failure. Despite advances in implantation techniques, LV lead placement can be impossible in up to 10% of cases. We, therefore, assessed the effects of RV septal pacing from mid septum (RVmIVS) and outflow tract (RVOT) on cardiac performance, in comparison with CRT. Twenty-two patients scheduled for CRT underwent dual-chamber temporary pacing. The ventricular lead was placed at the RV apex (RVA), RVmIVS, and RVOT in random order. Comprehensive echocardiography was performed in a baseline AAI mode and then at each RV position in dual chamber pacemaker function (D pacing, D sensing, D dual responses) mode and repeated on the next day following CRT implantation. Right ventricular apex pacing did not change any of the assessed echocardiography parameters. Both RVmIVS and RVOT pacing increased LV ejection fraction (EF): 29 ± 7% at baseline vs. 32 ± 6% (P = 0.02) and 32 ± 5% (P = 0.04) with RVmIVS and RVOT pacing, respectively. Similarly, the dyssynchrony index (Ts-SD) decreased: 50 ± 19 ms at baseline vs. 39 ± 17 ms (P = 0.04) and 37 ± 17 ms (P = 0.006) with RVmIVS and RVOT pacing, respectively. Cardiac resynchronization therapy further improved LVEF and Ts-SD to 36 ± 7% and 34 ± 15 ms, respectively, however, only LVEF was significantly higher compared with RVmIVS and RVOT pacing (P = 0.03 and P = 0.01 respectively). There were no significant differences in either LVEF or Ts-SD between RVmIVS and RVOT. Right ventricular septal pacing from mid septum or RVOT pacing improves LVEF and LV synchrony in CRT candidates. Further improvement in LVEF was achieved by CRT, which remains the ‘gold standard’ therapy in these patients. However, RV septal pacing is worthy of further study as an alternative strategy when LV lead implantation fails.
- Open Access
- 14 July 2011
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 13 (12) , 1738-1746
Impact of temporary right ventricular pacing from different sites on echocardiographic indices of cardiac function
To assess the impact of pacing from different right ventricular (RV) pacing sites on left ventricular (LV) function. Chronic apical RV pacing may induce heart failure. To reduce this RV, mid-septum and outflow tract are suggested as alternative pacing sites. We therefore assessed cardiac performance during temporary RV pacing from apical vs. mid-septum or outflow tract sites, using echocardiography and electrocardiography. Patients scheduled for a permanent pacemaker underwent temporary pacing in dual-chamber mode (DDD) and with atrio-ventricular delay optimized. The ventricular lead was moved to either the RV apex, mid-septum or outflow tract. Comprehensive echocardiography was performed in each position. Twenty-two patients completed the study. The baseline data was collected at atrial pacing mode (AAI). QRS duration lengthened with RV apical pacing (97 ± 22 ms AAI vs. 154 ± 18 ms RV apical, P< 0.001) and shortened with mid-septum or outflow tract pacing (147 ± 14 ms RV mid-septum and 136 ± 16 ms RV outflow tract, P= 0.001 and P< 0.001, respectively, vs. RV apical). Right ventricular apical pacing was associated with reductions in stroke volume and LV ejection fraction (54 ± 6% AAI vs. 48 ± 5% RV apical, P= 0.001). Right ventricular mid-septum (52 ± 5%) and outflow tract (54 ± 6%) pacing improved LV ejection fraction in comparison with apical pacing (P< 0.01 for both). Pacing at all sites induced dyssynchrony. In comparison with RV apical pacing dyssynchrony was reduced by mid-septum or outflow tract pacing. Right ventricular pacing at the mid-septum or outflow tract results in narrower QRS complexes, less dyssynchrony, and better LV systolic function than RV apical pacing.
- 14 July 2011
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 13 (12) , 1738-1746
Open AccessImpact of temporary right ventricular pacing from different sites on echocardiographic indices of cardiac function
To assess the impact of pacing from different right ventricular (RV) pacing sites on left ventricular (LV) function. Chronic apical RV pacing may induce heart failure. To reduce this RV, mid-septum and outflow tract are suggested as alternative pacing sites. We therefore assessed cardiac performance during temporary RV pacing from apical vs. mid-septum or outflow tract sites, using echocardiography and electrocardiography. Patients scheduled for a permanent pacemaker underwent temporary pacing in dual-chamber mode (DDD) and with atrio-ventricular delay optimized. The ventricular lead was moved to either the RV apex, mid-septum or outflow tract. Comprehensive echocardiography was performed in each position. Twenty-two patients completed the study. The baseline data was collected at atrial pacing mode (AAI). QRS duration lengthened with RV apical pacing (97 ± 22 ms AAI vs. 154 ± 18 ms RV apical, P< 0.001) and shortened with mid-septum or outflow tract pacing (147 ± 14 ms RV mid-septum and 136 ± 16 ms RV outflow tract, P= 0.001 and P< 0.001, respectively, vs. RV apical). Right ventricular apical pacing was associated with reductions in stroke volume and LV ejection fraction (54 ± 6% AAI vs. 48 ± 5% RV apical, P= 0.001). Right ventricular mid-septum (52 ± 5%) and outflow tract (54 ± 6%) pacing improved LV ejection fraction in comparison with apical pacing (P< 0.01 for both). Pacing at all sites induced dyssynchrony. In comparison with RV apical pacing dyssynchrony was reduced by mid-septum or outflow tract pacing. Right ventricular pacing at the mid-septum or outflow tract results in narrower QRS complexes, less dyssynchrony, and better LV systolic function than RV apical pacing.