Luan Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Luan Zhu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Lijuan Wang
2 shared publicationsYu Zhou
2 shared publications- De'An Liu
Shanghai Institute of Optics and Fine Mechanics (China)
1 shared publication Jianfeng Sun
1 shared publication- Jianfeng Sun
Key Laboratory of Space Laser Communication and Detection Technology, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, China
1 shared publication Liren Liu
1 shared publication
Latest Publications
- 1 January 2014
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 12 (11) , 111101-111104
Down-looking synthetic aperture imaging ladar demonstrator and its experiments over 1.2 km outdoor
We present a down-looking synthetic aperture imaging ladar demonstrator and its experiments over 1.2 km in the field. The achieved imaging resolution is in agreement with the theoretical design, and the resulting two-dimensional image is satisfied. The capability to eliminate the influence from atmospheric turbulence is fully proven by the experiments.
- 1 January 2014
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 12 (11) , 111101-111104
Down-looking synthetic aperture imaging ladar demonstrator and its experiments over 1.2 km outdoor
We present a down-looking synthetic aperture imaging ladar demonstrator and its experiments over 1.2 km in the field. The achieved imaging resolution is in agreement with the theoretical design, and the resulting two-dimensional image is satisfied. The capability to eliminate the influence from atmospheric turbulence is fully proven by the experiments.
- 28 August 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (18) , 20730-20737
Inhomogeneity measurement at oblique incidence by phase measuring interferometers
The huge power solid-state lasers require large optical materials with high quality. The inhomogeneity must be required to be measured. Inhomogeneity measurement is often done at normal incidence by interferometer, while the size of large blanks is limited to the interferometer aperture. A five-step method to measure refractive index inhomogeneity over the interferometer aperture is proposed in this paper. The variation of the refractive index inhomogeneity of the glass blank is directly calculated using five interferograms measured at oblique incidence. The high repeatability of the results is given. The reliability of the method is further verified by comparing the same part measured at normal incidence.
- 28 August 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (18) , 20730-20737
Inhomogeneity measurement at oblique incidence by phase measuring interferometers
The huge power solid-state lasers require large optical materials with high quality. The inhomogeneity must be required to be measured. Inhomogeneity measurement is often done at normal incidence by interferometer, while the size of large blanks is limited to the interferometer aperture. A five-step method to measure refractive index inhomogeneity over the interferometer aperture is proposed in this paper. The variation of the refractive index inhomogeneity of the glass blank is directly calculated using five interferograms measured at oblique incidence. The high repeatability of the results is given. The reliability of the method is further verified by comparing the same part measured at normal incidence.
- 19 August 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7091, 70910S
The mechanical design of the large-optics double-shearing interferometer for the test of diffraction-limited wavefront
For testing the large-aperture and the diffraction-limited wavefront, we have proposed a revised Mach-Zehnder double-shearing interferometer with an aperture of 500 millimeters. This interferometer is composed of six same size plates. One plate is used as the beam splitter. Another one plate is acted as the beam combiner. Other plates are used as reflectors and one of them is cut to two parts. In this interferometer, two reflectors can be moved as a whole to change the shearing amount. The reflector cut to two parts is positioned to form the double shearing and it can be move to make the interferometer become an equal optical path system. In fitting process of this interferometer, the six plates are placed in the correct positions and directions by adjusting of the mechanical structure. The mechanical structures is also demanded to maintain the shape and position of the six plates in the application process. Thus the mechanical design of the interferometer is very important. The mechanical design is described in detail in this paper. The beam splitter and the beam combiner are mounted in one plate frame using strap-style support. A reference plane is generated on the lateral surface of the frame to act as a reference for the adjustment of all plates. The mounting structure of the reflectors is similar to the one of the beam splitter and their difference is the addition of the direction adjustment. With the mechanical design, this interferometer can meet the request of the wavefront testing.
- 19 August 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7091, 70910S
The mechanical design of the large-optics double-shearing interferometer for the test of diffraction-limited wavefront
For testing the large-aperture and the diffraction-limited wavefront, we have proposed a revised Mach-Zehnder double-shearing interferometer with an aperture of 500 millimeters. This interferometer is composed of six same size plates. One plate is used as the beam splitter. Another one plate is acted as the beam combiner. Other plates are used as reflectors and one of them is cut to two parts. In this interferometer, two reflectors can be moved as a whole to change the shearing amount. The reflector cut to two parts is positioned to form the double shearing and it can be move to make the interferometer become an equal optical path system. In fitting process of this interferometer, the six plates are placed in the correct positions and directions by adjusting of the mechanical structure. The mechanical structures is also demanded to maintain the shape and position of the six plates in the application process. Thus the mechanical design of the interferometer is very important. The mechanical design is described in detail in this paper. The beam splitter and the beam combiner are mounted in one plate frame using strap-style support. A reference plane is generated on the lateral surface of the frame to act as a reference for the adjustment of all plates. The mounting structure of the reflectors is similar to the one of the beam splitter and their difference is the addition of the direction adjustment. With the mechanical design, this interferometer can meet the request of the wavefront testing.