Pavel Rozsíval
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pavel Rozsíval has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Nada Jiraskova
University Hospital and Faculty of Medicine of Charles University in Hradec Kralove
3 shared publications - Jan Studnička
Department of Ophthalmology, Faculty of Medicine in Hradec Kralove, Charles University in Prague and University Hospital Hradec Kralove, Hradec Kralove, Czech Republic
2 shared publications - Kateřina Tyx
Department of Ophthalmology, Institute of Aviation Medicine Prague, 160 00 Prague, Czech Republic
2 shared publications - Ladislav Viktor Nováček
Department of Ophthalmology, School of Medicine Hradec Králové, Charles University Prague, 500 03 Hradec Králové, Czech Republic
2 shared publications - Marie Němcová
Department of Ophthalmology, Institute of Aviation Medicine Prague, 160 00 Prague, Czech Republic
2 shared publications - Pavel Studeny
Ophthalmology Department of the Third Medical Faculty, University Hospital Kralovske Vinohrady, 100 34 Prague, Czech Republic
2 shared publications
Latest Publications
- Open Access
- 19 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (14) , 4194
Simultaneous Presbyopia and Astigmatism Correction with a Novel Trifocal Toric Intraocular Lens—A One-Year Follow-Up
The current investigation evaluates the efficiency of the trifocal toric Liberty 677MTY intraocular lens (IOL) in correcting preoperative corneal astigmatism in cataract patients demanding spectacle independence. The retrospective evaluation included 28 eyes of 15 patients with preoperative corneal astigmatism of at least 1.0 Dioptre (D). All patients were followed up for one year postoperatively. Residual refractive errors and visual acuities at multiple distances were measured. Binocular visual acuity and contrast sensitivity defocus curves were plotted. Visual functions and patient satisfaction were assessed. The efficiency of astigmatism correction was determined using the vector analysis method. The mean spherical equivalent refraction (SEQ) improved from 2.72 ± 1.62 D to 0.10 ± 0.48 D. The cylindric refraction decreased from 1.18 ± 0.45 D to 0.16 ± 0.31 D. Vector analysis proved efficient astigmatism correction with a centroid of 0.10 ± 0.34 D at 161°. Ninety-two percent of eyes resulted within 0.5 D from the target refraction. Visual acuities were 0.1 logMAR or better from +1.0 to −3.5 D defocus values. Visual tasks could be performed without major difficulties. Our patients were highly satisfied. Refractive and visual outcomes with the investigated presbyopia-correcting toric IOL are predictable and the lens provides excellent trifocal vision.
- 19 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (14) , 4194
Open AccessSimultaneous Presbyopia and Astigmatism Correction with a Novel Trifocal Toric Intraocular Lens—A One-Year Follow-Up
The current investigation evaluates the efficiency of the trifocal toric Liberty 677MTY intraocular lens (IOL) in correcting preoperative corneal astigmatism in cataract patients demanding spectacle independence. The retrospective evaluation included 28 eyes of 15 patients with preoperative corneal astigmatism of at least 1.0 Dioptre (D). All patients were followed up for one year postoperatively. Residual refractive errors and visual acuities at multiple distances were measured. Binocular visual acuity and contrast sensitivity defocus curves were plotted. Visual functions and patient satisfaction were assessed. The efficiency of astigmatism correction was determined using the vector analysis method. The mean spherical equivalent refraction (SEQ) improved from 2.72 ± 1.62 D to 0.10 ± 0.48 D. The cylindric refraction decreased from 1.18 ± 0.45 D to 0.16 ± 0.31 D. Vector analysis proved efficient astigmatism correction with a centroid of 0.10 ± 0.34 D at 161°. Ninety-two percent of eyes resulted within 0.5 D from the target refraction. Visual acuities were 0.1 logMAR or better from +1.0 to −3.5 D defocus values. Visual tasks could be performed without major difficulties. Our patients were highly satisfied. Refractive and visual outcomes with the investigated presbyopia-correcting toric IOL are predictable and the lens provides excellent trifocal vision.
- Open Access
- 24 July 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (15) , 3268
Comparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics
This semi-prospective, parallel, comparative investigation evaluated the clinical outcomes and quality of vision (contrast sensitivity, visual function, dysphotopsia, spectacle use, overall satisfaction) after mono- or bilateral implantation of two presbyopia-correcting intraocular lenses (IOL)—the Liberty® 677MY or the AT LISA® tri 839M—in 50 eyes of 25 cataract patients. Clinical outcomes were assessed 3 and 12 months postoperatively. Eighty-nine percent of eyes implanted with the Liberty IOL and 59% of eyes implanted with the AT LISA IOL achieved a refractive outcome ±0.5 diopters of the target (emmetropia). Refractive outcomes were stable with both lenses. The proportions of eyes with 20/20 uncorrected distance visual acuity (UDVA) and 20/20 uncorrected near visual acuity (UNVA) were higher in the Liberty group than in the AT LISA group (UDVA: 56% vs. 41%; UNVA: 83% vs. 66%). Optical quality assessment results were comparable for the two IOLs. Superior photopic contrast sensitivity was found with the Liberty lens. The rate of Nd:YAG capsulotomy at the 12-month follow-up was 16.7% in the Liberty group and 40.6% for the AT LISA IOL. Considering that both lenses are made from the same material, we propose that the noted differences in clinical outcomes may derive from differences in design and optical surface between the two IOLs.
- 24 July 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (15) , 3268
Open AccessComparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics
This semi-prospective, parallel, comparative investigation evaluated the clinical outcomes and quality of vision (contrast sensitivity, visual function, dysphotopsia, spectacle use, overall satisfaction) after mono- or bilateral implantation of two presbyopia-correcting intraocular lenses (IOL)—the Liberty® 677MY or the AT LISA® tri 839M—in 50 eyes of 25 cataract patients. Clinical outcomes were assessed 3 and 12 months postoperatively. Eighty-nine percent of eyes implanted with the Liberty IOL and 59% of eyes implanted with the AT LISA IOL achieved a refractive outcome ±0.5 diopters of the target (emmetropia). Refractive outcomes were stable with both lenses. The proportions of eyes with 20/20 uncorrected distance visual acuity (UDVA) and 20/20 uncorrected near visual acuity (UNVA) were higher in the Liberty group than in the AT LISA group (UDVA: 56% vs. 41%; UNVA: 83% vs. 66%). Optical quality assessment results were comparable for the two IOLs. Superior photopic contrast sensitivity was found with the Liberty lens. The rate of Nd:YAG capsulotomy at the 12-month follow-up was 16.7% in the Liberty group and 40.6% for the AT LISA IOL. Considering that both lenses are made from the same material, we propose that the noted differences in clinical outcomes may derive from differences in design and optical surface between the two IOLs.
- Open Access
- 30 July 2016
- Published by Care Comm in Česká a slovenská neurologie a neurochirurgie
- Vol. 79/112 (4) , 458-462
Anterior Ischemic Optic Neuropathy and Branch Retinal Artery Occlusion after Transcatheter Closure of Foramen Ovale – a Case Report
- 30 July 2016
- Published by Care Comm in Česká a slovenská neurologie a neurochirurgie
- Vol. 79/112 (4) , 458-462
Open AccessAnterior Ischemic Optic Neuropathy and Branch Retinal Artery Occlusion after Transcatheter Closure of Foramen Ovale – a Case Report
- 18 August 2014
- Published by Springer Nature
- p. 221-229
AlphaCor: Indications, Contraindications, Techniques and Outcomes
- 18 August 2014
- Published by Springer Nature
- p. 221-229
AlphaCor: Indications, Contraindications, Techniques and Outcomes
- 1 January 2012
- Vol. 151 (11) , 527-30
[Papilledema and ischemic edema of the optic nerve head].
The authors report an unusual case of two etiologically different forms of the optic nerve head edema consequently occurring in short time interval: ischemic optic nerve edema and papilledema. A 58-year old woman was diagnosed with papilledema in the course of idiopathic intracranial hypertension. After successful treatment both papilledema and subjective symptoms subsided during 5 months. Three months later she was presented with worsening of visual functions in her left eye and anterior ischemic optic neuropathy was diagnosed. On this rare case we would like to emphasize the necessity of proper differential diagnosis of optic nerve head edema in relation with the treatment and prognosis.
- 1 January 2012
- Vol. 151 (11) , 527-30
[Papilledema and ischemic edema of the optic nerve head].
The authors report an unusual case of two etiologically different forms of the optic nerve head edema consequently occurring in short time interval: ischemic optic nerve edema and papilledema. A 58-year old woman was diagnosed with papilledema in the course of idiopathic intracranial hypertension. After successful treatment both papilledema and subjective symptoms subsided during 5 months. Three months later she was presented with worsening of visual functions in her left eye and anterior ischemic optic neuropathy was diagnosed. On this rare case we would like to emphasize the necessity of proper differential diagnosis of optic nerve head edema in relation with the treatment and prognosis.