Mario Pineda
Research Subjects
Mario Pineda has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Rong Z. Gan
School of Biomedical Engineering, University of Oklahoma, Norman, USA
2 shared publications - Don Nakmali
University of Oklahoma
1 shared publication Shangyuan Jiang
School of Aerospace & Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
1 shared publication- Vikrant Palan
Polytec, Inc
1 shared publication - Xiangming Zhang
School of Aerospace and Mechanical Engineering and Bioengineering Center, University of Oklahoma, 865 Asp Avenue, Room 200, Norman, OK, 73019, USA,
1 shared publication - Xiying Guan
School of Aerospace and Mechanical Engineering and Bioengineering Center, University of Oklahoma, Norman, OK, United States
1 shared publication
Latest Publications
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1965 (1) , 110002
Age-related full-field motion change in baboon tympanic membrane
Clinical observations indicate that the structure and function of the middle ear change from newborn to adult. However, due to the lack of young children’s temporal bones for investigators, characterizations of the pediatric middle ear function and tissue mechanical properties are limited. Higher primates such as olive baboons (Papio anubis) ear specimens may provide alternative testing sources whose properties are likely to closely resemble those of humans. This paper reports our recent study on measurement of the tympanic membrane (TM) surface motion of baboon temporal bones in the age range from 6 months to young adult using the scanning laser Doppler vibrometry (SLDV). The full-field TM motion and the umbo displacement show that the mobility of the TM at frequencies below 2 kHz increased as age increases and the middle ear input impedance decreased with the age increase. The traveling-wave-like vibration modes in adult TMs started appearing at lower frequencies than that of young baboons. The results show the age-dependent middle ear function changes in baboons which may open a new research dimension to provide urgently needed data for biomechanical properties of young children ears.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1965 (1) , 110002
Age-related full-field motion change in baboon tympanic membrane
Clinical observations indicate that the structure and function of the middle ear change from newborn to adult. However, due to the lack of young children’s temporal bones for investigators, characterizations of the pediatric middle ear function and tissue mechanical properties are limited. Higher primates such as olive baboons (Papio anubis) ear specimens may provide alternative testing sources whose properties are likely to closely resemble those of humans. This paper reports our recent study on measurement of the tympanic membrane (TM) surface motion of baboon temporal bones in the age range from 6 months to young adult using the scanning laser Doppler vibrometry (SLDV). The full-field TM motion and the umbo displacement show that the mobility of the TM at frequencies below 2 kHz increased as age increases and the middle ear input impedance decreased with the age increase. The traveling-wave-like vibration modes in adult TMs started appearing at lower frequencies than that of young baboons. The results show the age-dependent middle ear function changes in baboons which may open a new research dimension to provide urgently needed data for biomechanical properties of young children ears.
- 9 August 2014
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 15 (6) , 867-881
Experimental and Modeling Study of Human Tympanic Membrane Motion in the Presence of Middle Ear Liquid
Vibration of the tympanic membrane (TM) has been measured at the umbo using laser Doppler vibrometry and analyzed with finite element (FE) models of the human ear. Recently, full-field TM surface motion has been reported using scanning laser Doppler vibrometry, holographic interferometry, and optical coherence tomography. Technologies for imaging human TM motion have the potential to lead to using a dedicated clinical diagnosis tool for identification of middle ear diseases. However, the effect of middle ear fluid (liquid) on TM surface motion is still not clear. In this study, a scanning laser Doppler vibrometer was used to measure the full-field surface motion of the TM from four human temporal bones. TM displacements were measured under normal and disease-mimicking conditions with different middle ear liquid levels over frequencies ranging from 0.2 to 8 kHz. An FE model of the human ear, including the ear canal, middle ear, and spiral cochlea was used to simulate the motion of the TM in normal and disease-mimicking conditions. The results from both experiments and FE model show that a simple deflection shape with one or two major displacement peak regions of the TM in normal ear was observed at low frequencies (1 kHz and below) while complicated ring-like pattern of the deflection shapes appeared at higher frequencies (4 kHz and above). The liquid in middle ear mainly affected TM deflection shapes at the frequencies higher than 1 kHz.
- 9 August 2014
- Published by Springer Nature in Journal of the Association for Research in Otolaryngology
- Vol. 15 (6) , 867-881
Experimental and Modeling Study of Human Tympanic Membrane Motion in the Presence of Middle Ear Liquid
Vibration of the tympanic membrane (TM) has been measured at the umbo using laser Doppler vibrometry and analyzed with finite element (FE) models of the human ear. Recently, full-field TM surface motion has been reported using scanning laser Doppler vibrometry, holographic interferometry, and optical coherence tomography. Technologies for imaging human TM motion have the potential to lead to using a dedicated clinical diagnosis tool for identification of middle ear diseases. However, the effect of middle ear fluid (liquid) on TM surface motion is still not clear. In this study, a scanning laser Doppler vibrometer was used to measure the full-field surface motion of the TM from four human temporal bones. TM displacements were measured under normal and disease-mimicking conditions with different middle ear liquid levels over frequencies ranging from 0.2 to 8 kHz. An FE model of the human ear, including the ear canal, middle ear, and spiral cochlea was used to simulate the motion of the TM in normal and disease-mimicking conditions. The results from both experiments and FE model show that a simple deflection shape with one or two major displacement peak regions of the TM in normal ear was observed at low frequencies (1 kHz and below) while complicated ring-like pattern of the deflection shapes appeared at higher frequencies (4 kHz and above). The liquid in middle ear mainly affected TM deflection shapes at the frequencies higher than 1 kHz.