SLSibo Li

Sibo Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sibo Li has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Micromachined Pb(Mg1/3Nb2/3)O3-PbTiO3 Single Crystal Composite Circular Array for Intravascular Ultrasound Imaging

    by Sibo Li, Jian Tian, Xiaoning Jiang

    This paper describes the design, fabrication, and characterization of a micromachined high-frequency Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) single crystal/epoxy 1–3 composite ultrasound circular array. The 1–3 composites were fabricated by deep reactive ion etching (DRIE) of PMN-PT single crystal. The feature size of single crystal pillars was 18 μm in diameter. The kerf between pillars was less than 4 μm. A 50-element circular array transducer (radially outward) with the pitch of 100 μm was wrapped around a needle resulting in an outer diameter of 1.7 mm. The array test showed that the center frequency reached 39±2 MHz and −6-dB fractional bandwidth was 82±6%. The insertion loss was −41 dB, and crosstalk between adjacent elements was −24 dB. A radial outward imaging testing with phantom wires (D = 50 μm) was conducted. The image was in a dynamic range of 30 dB to show a penetration depth of 6 mm by using the synthetic aperture method. The −6-dB beam width was estimated to be 60 μm in the axial direction at 3.1 mm distance away from the probe. The results suggest that the 40 MHz micromachined 1–3 composite circular array is promising for intravascular ultrasound (IVUS) imaging applications.


  • Open Access

    Dual-Frequency Piezoelectric Transducers for Contrast Enhanced Ultrasound Imaging

    by K. Heath Martin, Brooks D. Lindsey, Jianguo Ma, Mike Lee, Sibo Li, F. Stuart Foster, Xiaoning Jiang, Paul A. Dayton

    For many years, ultrasound has provided clinicians with an affordable and effective imaging tool for applications ranging from cardiology to obstetrics. Development of microbubble contrast agents over the past several decades has enabled ultrasound to distinguish between blood flow and surrounding tissue. Current clinical practices using microbubble contrast agents rely heavily on user training to evaluate degree of localized perfusion. Advances in separating the signals produced from contrast agents versus surrounding tissue backscatter provide unique opportunities for specialized sensors designed to image microbubbles with higher signal to noise and resolution than previously possible. In this review article, we describe the background principles and recent developments of ultrasound transducer technology for receiving signals produced by contrast agents while rejecting signals arising from soft tissue. This approach relies on transmitting at a low-frequency and receiving microbubble harmonic signals at frequencies many times higher than the transmitted frequency. Design and fabrication of dual-frequency transducers and the extension of recent developments in transducer technology for dual-frequency harmonic imaging are discussed.