EMEmmanuel A. M. Mylanus

Emmanuel A. M. Mylanus

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Emmanuel A. M. Mylanus has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Ad F.M. Snik

    Donders Institute for Brain, Cognition and Behaviour, Department of Otorhinolaryngology, Head and Neck Surgery, Hearing and Implants, Radboud University Medical Centre Nijmegen, The Netherlands

    2 shared publications
  • Andy J. Beynon

    Department of Otorhinolaryngology, Radboud university medical center, Nijmegen, The Netherlands

    2 shared publications
  • Marloes Sparreboom

    Affiliation Department of Otorhinolaryngology, Head and Neck Surgery, Hearing and Implants, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Centre, Nijmegen, The Netherlands

    2 shared publications
  • Ad F. M. Snik

    Department of Otorhinolaryngology, Head and Neck Surgery, Hearing and Implants, Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands

    1 shared publication
  • Ad F. M. Snik

    Department of Otorhinolaryngology, University Hospital Nijmegen, The Netherlands

    1 shared publication
  • Ad Snik

    Department of Otorhinolaryngology, Radboud University Medical Centre and Donders Institute for Brain, Cognition and Behaviour, Nijmegen, The Netherlands

    1 shared publication

Latest Publications

  • Auditory Cortical Maturation in Children With Sequential Bilateral Cochlear Implants

    by Marloes Sparreboom, Andy J. Beynon, Ad F. M. Snik, Emmanuel A. M. Mylanus

    Objective To assess the effect of sequential bilateral cochlear implantation on auditory, cortical maturation after various periods of unilateral cochlear implant use. Study Design Prospective cohort study. Setting Tertiary academic referral center. Patients Thirty prelingually deaf children, who received their first implant at a mean age of 1.8 years and their second implant at a mean age of 5.3 years. Intervention Sequential bilateral cochlear implantation. Main Outcomes Measure The electrically evoked auditory cortical response (EACR) was evoked by the 2 implants separately after 12 and 24 months of bilateral cochlear implant use. P1 and N2 latencies and RMS amplitudes were compared between both implant sides and were compared with those of a group of 27 age-matched children with normal hearing. Results EACR latencies diminished over time for both implant sides. RMS amplitudes and P1 latencies elicited by the second implant were still significantly different from that of the first implant after 24 month. After 24 months, the difference in N2 latencies between both implant sides was no longer significant, although still apparent. Interimplant delay had an adverse effect on RMS amplitudes and waveform morphology. EACR latencies were age appropriate, although RMS amplitudes evoked by the second implant were smaller than those of the children with normal hearing. Conclusion Auditory cortical maturation is possible after extended unilateral cochlear implant use, although responses evoked by the second implant still lack behind that of the experienced first implant. It is not clear if the auditory cortical response will become similar on both implant sides over time, especially for the children with longer interimplant delays.


  • Open Access

    Estimated Cost-effectiveness of Active Middle-Ear Implantation in Hearing-Impaired Patients With Severe External Otitis

    by Ad F. M. Snik, Noortje T. L. van Duijnhoven, Emmanuel A. M. Mylanus, Cor W. R. J. Cremers

    In patients with moderate to severe sensorineural hearing loss, conventional hearing aid fitting may be troublesome owing to chronic external otitis. Although some patients benefit from vented or silver- or gold-coated ear molds, others continue to experience pain or itching when the ear canal is occluded, which leads to nonuse of the hearing aid. In these patients, the electronic middle-ear implant may form a solution, because the device does not block the ear canal. At present, 2 types of middle-ear implants are commercially available: the Vibrant Soundbridge (Med-El, Innsbruck, Austria)1-3 and the Otologics MET device (Otologics LLC, Boulder, Colo).4-6


  • Fitting range of the BAHA Cordelle

    by Arjan J. Bosman, Ad F.M. Snik, Emmanuel A.M. Mylanus, Cor W.R.J. Cremers

    The performance of the most powerful Bone-Anchored Hearing Aid (BAHA) currently available, the BAHA Cordelle, was evaluated in 25 patients with severe to profound mixed hearing loss. Patients showed bone conduction thresholds at 500, 1000 and 2000 Hz, ranged between 30 and 70 dB HL, and an additional air-bone gap of about at least 30 dB. With the BAHA Cordelle, free-field thresholds improve relative to bone-conduction thresholds with 1.5, 5.0, 17.8, and 4.3 dB at 500, 1000, 2000, and 4000 Hz, respectively, with substantial inter-individual variability. The differences in unaided air conduction thresholds and aided free-field thresholds amount to 45.3, 45.8, 47.5, and 43.5 dB at 500, 1000, 2000, and 4000 Hz, respectively. Speech perception, measured both with monosyllables of the consonant-vowel-consonant type and with bisyllables, showed highly similar results. The fitting range of a (linear) hearing aid is determined by its gain characteristics. Requiring aided speech reception thresholds at or better than 65 dB SPL results in an upper limit of the fitting range of the BAHA Cordelle for bone-conduction thresholds of 51, 56, 67, and 58 dB HL at 500, 1000, 2000, and 4000 Hz, respectively. The dynamic range provided by the BAHA Cordelle was estimated from loudness growth functions at 500, 1500, and 3000 Hz employing 7-point categorical scaling. On average, aided loudness growth functions exhibit normal slopes but they level off at input levels of about 80, 70, 65 dB SPL for 500, 1500, and 3000 Hz stimuli, respectively. Measurements with a skull simulator demonstrated that the levelling-off reflects saturation of the output of the Cordelle. The relatively low saturation levels of the device suggest that increasing maximum output levels may be a worthwhile consideration for candidates with more profound sensorineural loss.