Yiwen Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yiwen Yang has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Lei Li
Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing 314001, Zhejiang, China
14 shared publications Hailong Wang
Provincial Key Laboratory of Multimodal Perceiving and Intelligent Systems, Engineering Research Center of Intelligent Human Health Situation Awareness of Zhejiang Province, Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological and Chemical Engineering, Jiaxing University, Jiaxing 314001, PR China
12 shared publicationsYanbo Zeng
Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological and Chemical Engineering, Jiaxing University, Jiaxing, Zhejiang, 314001, China
10 shared publicationsQiukai Tang
Clinical Laboratory, Zhejiang Sian International Hospital, Jiaxing 314031, Zhejiang, China
9 shared publicationsJian Zhang
College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing, 314001, Zhejiang, China
6 shared publications- Yanbo Zeng
Jiaxing Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing, People’s Republic of China
5 shared publications
Latest Publications
- 30 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (8) , 1667-1673
Pyrene-based fluorescent molecularly imprinted polymer for the rapid and selective detection of oxytetracycline based on the inner filter effect
Synthesis process for the Al-Py monomer, preparation of Py-FMIP and the procedure for oxytetracycline (OTC) detection using Py-FMIP.
- 30 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (8) , 1667-1673
Pyrene-based fluorescent molecularly imprinted polymer for the rapid and selective detection of oxytetracycline based on the inner filter effect
Synthesis process for the Al-Py monomer, preparation of Py-FMIP and the procedure for oxytetracycline (OTC) detection using Py-FMIP.
- 11 August 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (9) , 586
Ultrasensitive determination of insulin by an unlabelled fluorescent aptasensor based on Fe3O4@SiO2 and an oxadiazole compound with AIEE activity
A novel fluorescent organic compound, OBEI, exhibiting aggregation-induced emission enhancement (AIEE) characteristics was successfully synthesized. Leveraging its unique photophysical properties, a label-free fluorescent aptasensor was developed using OBEI as the fluorescent reporter and Fe3O4@SiO2 magnetic beads as the adsorption substrate. The sensing mechanism relies on the formation of an INS-Apt/OBEI complex through electrostatic and hydrophobic interactions between OBEI and the insulin-specific aptamer (INS-Apt). This complex becomes immobilized on the magnetic bead surface via hydrogen bonding. Upon insulin introduction, the strong target-aptamer affinity triggers complex dissociation from the magnetic substrate, leaving the fluorescent INS-Apt/OBEI complex in solution after magnetic separation. The fluorescent intensity of the supernatant exhibited a linear response to insulin concentrations ranging from 0.033 pM to 10 nM, achieving a remarkable detection limit of 0.01 pM (S/N = 3). The biosensor demonstrates remarkable specificity for insulin against potential interferents and has been successfully implemented for insulin determination in human serum samples.
- 11 August 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (9) , 586
Ultrasensitive determination of insulin by an unlabelled fluorescent aptasensor based on Fe3O4@SiO2 and an oxadiazole compound with AIEE activity
A novel fluorescent organic compound, OBEI, exhibiting aggregation-induced emission enhancement (AIEE) characteristics was successfully synthesized. Leveraging its unique photophysical properties, a label-free fluorescent aptasensor was developed using OBEI as the fluorescent reporter and Fe3O4@SiO2 magnetic beads as the adsorption substrate. The sensing mechanism relies on the formation of an INS-Apt/OBEI complex through electrostatic and hydrophobic interactions between OBEI and the insulin-specific aptamer (INS-Apt). This complex becomes immobilized on the magnetic bead surface via hydrogen bonding. Upon insulin introduction, the strong target-aptamer affinity triggers complex dissociation from the magnetic substrate, leaving the fluorescent INS-Apt/OBEI complex in solution after magnetic separation. The fluorescent intensity of the supernatant exhibited a linear response to insulin concentrations ranging from 0.033 pM to 10 nM, achieving a remarkable detection limit of 0.01 pM (S/N = 3). The biosensor demonstrates remarkable specificity for insulin against potential interferents and has been successfully implemented for insulin determination in human serum samples.
- 5 November 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1333, 343386
Detection of C-reactive protein using a label-free NIR fluorescent aptasensor with a large Stokes shift based on an AIEE anthracene derivative
- 5 November 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1333, 343386
Detection of C-reactive protein using a label-free NIR fluorescent aptasensor with a large Stokes shift based on an AIEE anthracene derivative
- 24 October 2024
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 60 (92) , 13570-13573
Detecting carcinoembryonic antigen based on the aggregation-induced emission enhancement effect
In this study, a novel label-free fluorescent aptasensor with an aggregation-induced emission enhancement effect was developed and applied for the detection of carcinoembryonic antigen (CEA). The sensor has a simple detection mechanism, easy operation, high sensitivity (with low limit of detection of 1 pg mL−1), good selectivity, and wide linear range (0.003–10 ng mL−1). In addition, it can be directly applied for the determination of CEA in human serum.
- 24 October 2024
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 60 (92) , 13570-13573
Detecting carcinoembryonic antigen based on the aggregation-induced emission enhancement effect
In this study, a novel label-free fluorescent aptasensor with an aggregation-induced emission enhancement effect was developed and applied for the detection of carcinoembryonic antigen (CEA). The sensor has a simple detection mechanism, easy operation, high sensitivity (with low limit of detection of 1 pg mL−1), good selectivity, and wide linear range (0.003–10 ng mL−1). In addition, it can be directly applied for the determination of CEA in human serum.
- 16 May 2024
- Published by Springer Nature in Journal of Fluorescence
- Vol. 35 (5) , 3301-3312
Ultrasensitive Detection of Prostate Specific Antigen by an Unlabeled Fluorescence Aptasensor Based on the AIE Effect
The accurate and sensitive detection of prostate specific antigen (PSA) is vital for the early diagnosis and treatment of prostate cancer. To this end, an unlabeled fluorescent aptasensor was constructed by using a novel Compound B {1,1ʹ-(1,4-phenylene) bis(3-ethyl-1H-imidazol-3-ium) iodide} with aggregation-induced emission (AIE) activity as a fluorescence signal and NH2-Fe3O4 particle as an adsorption platform. Compound B could combine with prostate specific antigen aptamers (PSA-Apt) to form a PSA-Apt/B complex, which further generated the AIE effect. Then, PSA was added to the PSA-Apt/B solution. PSA combined with PSA-Apt/B to form the PSA-Apt/B/PSA complex. Next, NH2-Fe3O4 magnetic particles were added to the solution. Given that PSA-Apt/B/PSA would no longer combine with NH2-Fe3O4 magnetic particles, the PSA-Apt/B/PSA complex remained in the supernate after magnet separation, and the supernate showed strong fluorescence (I). When no PSA was added to the PSA-Apt/B solution, PSA-Apt/B could combine with NH2-Fe3O4 magnetic particles and would be sucked into the bottom of the test tube by magnet, and the supernate would show weak fluorescence (I0). Result showed that the difference between the above-mentioned two fluorescence values (∆I = I − I0) had an excellent linear relationship with the PSA concentration within the concentration range of 0.01–10 ng/mL, and its limit of detection was 3 pg/mL (S/N = 3). In addition, the sensor has high accuracy and can be directly used to test PSA in actual serum samples.
- 16 May 2024
- Published by Springer Nature in Journal of Fluorescence
- Vol. 35 (5) , 3301-3312
Ultrasensitive Detection of Prostate Specific Antigen by an Unlabeled Fluorescence Aptasensor Based on the AIE Effect
The accurate and sensitive detection of prostate specific antigen (PSA) is vital for the early diagnosis and treatment of prostate cancer. To this end, an unlabeled fluorescent aptasensor was constructed by using a novel Compound B {1,1ʹ-(1,4-phenylene) bis(3-ethyl-1H-imidazol-3-ium) iodide} with aggregation-induced emission (AIE) activity as a fluorescence signal and NH2-Fe3O4 particle as an adsorption platform. Compound B could combine with prostate specific antigen aptamers (PSA-Apt) to form a PSA-Apt/B complex, which further generated the AIE effect. Then, PSA was added to the PSA-Apt/B solution. PSA combined with PSA-Apt/B to form the PSA-Apt/B/PSA complex. Next, NH2-Fe3O4 magnetic particles were added to the solution. Given that PSA-Apt/B/PSA would no longer combine with NH2-Fe3O4 magnetic particles, the PSA-Apt/B/PSA complex remained in the supernate after magnet separation, and the supernate showed strong fluorescence (I). When no PSA was added to the PSA-Apt/B solution, PSA-Apt/B could combine with NH2-Fe3O4 magnetic particles and would be sucked into the bottom of the test tube by magnet, and the supernate would show weak fluorescence (I0). Result showed that the difference between the above-mentioned two fluorescence values (∆I = I − I0) had an excellent linear relationship with the PSA concentration within the concentration range of 0.01–10 ng/mL, and its limit of detection was 3 pg/mL (S/N = 3). In addition, the sensor has high accuracy and can be directly used to test PSA in actual serum samples.
- 7 August 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1278, 341692
Fluorometric detection of alpha-fetoprotein based on the use of a novel organic compound with AIE activity and aptamer-modified magnetic microparticles
- 7 August 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1278, 341692
Fluorometric detection of alpha-fetoprotein based on the use of a novel organic compound with AIE activity and aptamer-modified magnetic microparticles
- 15 October 2022
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (44) , 4576-4582
A label-free fluorescent aptasensor based on the AIE effect and CoOOH for ultrasensitive determination of carcinoembryonic antigen
Highly sensitive and specific detection of cancer markers (such as carcinoembryonic antigen) is very important for early diagnosis and treatment of cancer. Herein, we developed a label-free fluorescent aptamer biosensor based on the aggregation-induced emission (AIE) effect and hydroxycobalt oxide (CoOOH) platform, and used it to detect carcinoembryonic antigen (CEA) with high sensitivity and specificity. Fluorescent ionic liquid Compound B can combine with a CEA aptamer (CEA-Apt) through electrostatic attraction and hydrophobic interaction to form an ionic liquid/aptamer (CEA-Apt/B) complex and produce the AIE effect, thereby enhancing the fluorescence intensity of B. CEA-Apt/B was adsorbed on the surface of CoOOH when CoOOH was added to the buffer solution, and the fluorescence of B was quenched. After adding CEA to the solution, CEA-Apt/B bound to CEA and separated from the surface of CoOOH because CEA-Apt had stronger affinity for CEA, resulting in fluorescence recovery of B. In the level range of 0.67–10000 pg mL−1, the fluorescence recovery intensity of the sensor had an excellent linear relationship with the level of CEA, and its LOD was 0.2 pg mL−1 (S/N = 3). In addition, the sensor had good selectivity and can be directly used to detect CEA in human serum with high accuracy.
- 15 October 2022
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 14 (44) , 4576-4582
A label-free fluorescent aptasensor based on the AIE effect and CoOOH for ultrasensitive determination of carcinoembryonic antigen
Highly sensitive and specific detection of cancer markers (such as carcinoembryonic antigen) is very important for early diagnosis and treatment of cancer. Herein, we developed a label-free fluorescent aptamer biosensor based on the aggregation-induced emission (AIE) effect and hydroxycobalt oxide (CoOOH) platform, and used it to detect carcinoembryonic antigen (CEA) with high sensitivity and specificity. Fluorescent ionic liquid Compound B can combine with a CEA aptamer (CEA-Apt) through electrostatic attraction and hydrophobic interaction to form an ionic liquid/aptamer (CEA-Apt/B) complex and produce the AIE effect, thereby enhancing the fluorescence intensity of B. CEA-Apt/B was adsorbed on the surface of CoOOH when CoOOH was added to the buffer solution, and the fluorescence of B was quenched. After adding CEA to the solution, CEA-Apt/B bound to CEA and separated from the surface of CoOOH because CEA-Apt had stronger affinity for CEA, resulting in fluorescence recovery of B. In the level range of 0.67–10000 pg mL−1, the fluorescence recovery intensity of the sensor had an excellent linear relationship with the level of CEA, and its LOD was 0.2 pg mL−1 (S/N = 3). In addition, the sensor had good selectivity and can be directly used to detect CEA in human serum with high accuracy.