SWShouguo Wu

Shouguo Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shouguo Wu has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Lei Rui

    Department of Chemistry, University of Science and Technology of China, Hefei, Anhui, 230026, P.R. China

    5 shared publications
  • Longzhen Zheng

    Department of Chemistry, University of Science and Technology of China, Hefei, Anhui, 230026, P.R. China

    5 shared publications
  • Lei Nie

    Department of Chemistry, University of Science and Technology of China, Hefei, Anhui, 230026, P.R. China

    4 shared publications
  • Lei Zhou

    University of Science and Technology of China Department of Chemistry Hefei 230026, China

    4 shared publications
  • Xiangqin Lin

    Department of Chemistry, University of Science and Technology of China, Hefei, 230026, P. R. China

    4 shared publications
  • Chuanqin Wang

    Department of Chemistry, University of Science and Technology of China, Hefei 230026, China

    3 shared publications

Latest Publications

  • Electrocatalytic Oxidation of Calcium Folinate on Carboxyl Graphene Modified CuxO/Cu Electrode

    by Li-Wen Wang, Shou-Guo Wu, Tian-Yang Shi, Wei Wei, Pan Pan

    Carboxyl graphene modified CuxO/Cu electrode was fabricated. The bare copper electrode was firstly anodic polarized in 1.0 mol/L NaOH solution in order to get CuxO nanoparticles, then the carboxyl graphene (CG) was electrodeposited on the CuxO/Cu electrode by cyclic potential sweeping. The electrocatalytic oxidation behaviors of calcium folinate (CF) at the graphene modified CuxO/Cu electrode were investigated by cyclic voltammetry. A positive scan polarization reverse catalytic voltammetry was used to obtain the pure catalytic oxidation current. The graphene modified CuxO/Cu electrode was served as the electrochemical sensor of CF, a highly sensitivity of 22.0 µA·(µmol/µL)−1cm−2 was achieved, and the current response was linear with increasing CF concentration in the range of 2.0×10−7 mol/L to 2.0×10−5 mol/L, which crossed three orders of magnitude, and the detection limit was found 7.6×10−8 mol/L (S/N=3). In addition, the proposed sensor was successfully applied in determination of CF in drug sample.


  • High-Sensitive Glucose Biosensor Based on Ionic Liquid Doped Polyaniline/Prussian Blue Composite Film

    by Yao Yao, Shou-Guo Wu, Hai-Hong Xu, Li-Wen Wang

    The Prussian blue/ionic liquid-polyaniline/multiwall carbon nanotubes (PB/IL-PANI/MWNTs) composite film was fabricated by using cyclic voltammetry. The ion liquid acting as a lubricating agent, could enhance the electron delocalization degree and reduce the structural defects of the polyaniline. The surface morphology of the composite film revealed that the PB nanoparticles have smaller size than that in pure PB film. Due to the introduction of ion liquid, the PB/IL-PANI/MWNTs composite film showed wonderful synergistic effect which can remarkably enhance sensitivity, expand linear range and broaden acidic adaptability for hydrogen peroxide detection. The composite film demonstrated good stability in neutral solution contrast to pure PB film, with a linear range from 2.5 µmol/L to 0.5 mmol/L and a high sensitivity of 736.8 µA·(mmol/L)−1·cm−2 for H2O2 detection. Based on the composite film, an amperometric glucose biosensor was then fabricated by immobilizing glucose oxidase. Under the optimal conditions, the biosensor also exhibits excellent response to glucose with the linear range from 12.5 µmol/L to 1.75 mmol/L and a high sensitivity of 94.79 µA·(mmol/L)−1·cm−2 for H2O2. The detection limit was estimated 1.1 µmol/L. The resulting biosensor was applied to detect the blood sugar in human serum samples without any pretreatment, and the results were comparatively in agreement with the clinical assay.


  • Electrocatalytic Oxidation of Saccharides at MoOx/AuNPs Modified Electrode Towards Analytical Application

    by Shou-Guo Wu, Zhi-Xin Zhang, Qi-Ping Zhao, Lei Zhou, Yao Yao

    The MoOx/AuNPs composite film modified glassy carbon electrode was fabricated by electro-depositing simultaneously gold nanoparticles and molybdenum oxides using cyclic voltammetry. The morphology and topography of the MoOx/AuNPs composite were characterized by scan electron microscopy and X-ray photoelectron spectroscopy respectively, and the electrocatalytic oxidation of glucose at the MoOx/AuNPs composite film was investigated and analyzed in detail. It was shown that the MoOx/AuNPs composite was of strong electrocatalytic activity towards oxidation of glucose as well as other saccharides, so that an attempt was made for direct voltammetric determination of glucose. Then the positive scan polarization reverse catalytic voltammetry was proposed for the first time. Based on this method, the pure oxidation current was extracted by subtraction of the blank current in the reverse scan. The current sensitivity was enhanced tremendously and the signal to noise ratio was improved adequately. The electrocatalytic oxidation of glucose at the MoOx/AuNPs modified electrode was performed in alkaline medium, a wide linear range from 0.01 mmol/L to 4.0 mmol/L of glucose, a higher current sensitivity of 2.35 mA/(mmol/L·cm2), and a lower limit of detection of 9.01 µmol/L (at signal/noise=3) were achieved. In addition, the electrocatalytic oxidation of other saccharides such as lactose, fructose and sucrose was also evaluated.


  • Preparation of poly(N-acetylaniline)–Prussian blue hybrid composite film and its application to hydrogen peroxide sensing

    by Lei Zhou, Shouguo Wu, Haihong Xu, Qiping Zhao, Zhixin Zhang, Yao Yao

    A poly(N-acetylaniline)–Prussian blue (PNAANI–PB) hybrid composite film was prepared by co-electrodeposition. Using a spontaneous redox reaction, the PNAANI–PB hybrid film was prepared electrochemically by cyclic voltammetry in an electroplating bath containing a low concentration of N-acetylaniline. Its surface morphology showed that the PB nanoparticles in the hybrid film had a smaller size than those in the pure PB film. As a result of electrostatic interaction between the PNAANI and the PB particles, the PNAANI–PB hybrid film displays impressive synergistic effects that remarkably enhance its sensitivity, expand its linear range and broaden its acidic adaptability in the detection of H2O2. The hybrid film displays good stability in neutral solution, in contrast to the pure PB film, with a linear range from 10−6 to 10−3 M and a high sensitivity of 507.29 μA mM−1 cm−2 for H2O2 detection. An amperometric glucose biosensor was constructed by immobilizing glucose oxidase on the hybrid film. The biosensor showed an excellent response to glucose in the linear range 10−5–10−3 M and had a high sensitivity of 62.45 μA mM−1 cm−2. The glucose biosensor had a rapid response, good reproducibility and long-term stability and was free of interference from other coexisting electroactive species.


  • Stripping Analysis of Trace Arsenic Based on the MnOx/AuNPs Composite Film Modified Electrode in Alkaline Media

    by Shouguo Wu, Qiping Zhao, Lei Zhou, Zhixin Zhang

    A simple, rapid fabricated and sensitive modified electrode for detection of As(III) in alkaline media was proposed. The modified electrode was prepared by co‐electrodeposition of manganese oxides (MnOx) and gold nanoparticles (AuNPs) on the glassy carbon electrode (GCE) with cyclic voltammetry. Linear sweep anodic stripping voltammetry (LS‐ASV) was employed for the determination of arsenic (III) without interference from Cu(II), Hg(II), and other coexisting metal ions. A lower detection limit of 0.057 µg L−1 (S/N=3) were obtained with a accumulation time of 200 s. The proposed method was successfully applied to determine arsenic (III) in real water samples with satisfactory recoveries.


  • Graphene-gold Nanoparticle Composite Film Modified Electrode for Determination of Trace Mercury in Environmental Water

    by Xue-Mei Wang, Shou-Guo Wu, Hao Liu, Lei Zhou, Qi-Ping Zhao

    The graphene‐gold nanoparticles composite film modified glassy carbon electrode (EG‐ AuNPs/GCE) was prepared by one‐step coelectrodeposition and employed for determination of trace mercury in environmental water with differential pulse stripping voltammetry. Such a nanostructured composite film combined with the advantages of gold nanoparticles and graphene, can greatly promote the electron‐transfer process and increase accumulation ability for Hg(II), leading to a remarkably improved sensitivity. The linear calibration curve ranged from 0.2 μg/L to 30 μg/L for Hg(II) and the detection limit (S/N=3) was found to be 0.03 μg/L at a deposition time of 300 s. Moreover, the stablity of the as‐prepared electrode and interferences from other substances were evaluated. The modified electrode was successfully applied to the direct detection of Hg(II) in real water samples.


  • Protein molecularly imprinted polyacrylamide membrane: for hemoglobin sensing

    by Shouguo Wu, Wenguang Tan, Haihong Xu

    A hemoglobin sensor based on a molecularly imprinted polymer-modified electrode has been fabricated by electrochemically induced redox polymerization of acrylamide in the presence of hemoglobin.


  • Preparation, characterization, and electrocatalytic activity of Prussian blue/poly(N‐acetylaniline) composite film

    by Shouguo Wu, Chuanqin Wang, Changqin Wang, Xian Zhang, Taoling Wang

    Electrochemical preparation of the Prussian blue (PB)/poly (N‐acetylaniline) (PNAANI) composite film was carried out by cyclic voltammetry (CV). Its surface morphology, which was evaluated by Atom Force Microscope (AFM), revealed that PNAANI film provides lots of redox centers for PB growth so that the electrodeposition of PB showed high current densities, and the composite film is much denser than pure PB film. The surface microstructure of the composite film was also characterized by X‐ray photoelectron spectrum (XPS). Due to the existence of electrostatic interaction between the PNAANI (polycation) film and the PB (polyanion) film, the composite film cannot be considered as a simple adherent bilayer of PB film and PNAANI film. The electroactivity and stability of the PB/PNAANI composite film in acidic electrolytes containing potassium ions were comparatively higher than that of the pure PB film. The functional composite film is expected for use in the system capable of effective accumulation of charge, and for the analytical applications towards the reduction of hydrogen peroxide due to its high electrocatalytic activity. POLYM. COMPOS., 2008. © 2008 Society of Plastics Engineers