Wiktor Jakowluk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wiktor Jakowluk has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Miroslaw Swiercz
Faculty of Electrical Engineering, Bialystok University of Technology, Wiejska 45D, 15-351 Bialystok, Poland
2 shared publications - Karol Godlewski
Faculty of Computer Science, Bialystok University of Technology, Wiejska 45A, 15-351 Bialystok, Poland
1 shared publication M. Świercz
Faculty of Electrical Engineering Bialystok University of Technology Wiejska 45D 15-351 Bialystok Poland
1 shared publication- Sjoerd Boersma
Biometris Wageningen University & Research Droevendaalsesteeg 4 6708 PB Wageningen The Netherlands
1 shared publication Sławomir Jaszczak
West Pomeranian University of Technology in Szczecin, Faculty of Computer Science and Information Technology, Żołnierska 49, ˙71-210 Szczecin, Poland
1 shared publication
Latest Publications
- 22 September 2026
- Published by Springer Nature
- p. 357-369
Convex Optimization for Input Spectrum Design in Robust Closed-Loop Identification
- 22 September 2026
- Published by Springer Nature
- p. 357-369
Convex Optimization for Input Spectrum Design in Robust Closed-Loop Identification
- Open Access
- 29 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12665
Optimal Input Design for Fractional-Order System Identification Using an LMI-Based Frequency Error Criterion
This paper presents a novel approach to optimal input signal design for open-loop fractional-order system identification, using an integer-order approximation of the fractional operators to minimize the average input power. This is obtained by formulating the problem as an LMI (Linear Matrix Inequality) optimization problem with the limitation of achieving at least a specified model accuracy. The ORA (Oustaloup Recursive Approximation) method has been employed to model the fractional-order differentiation operator in discrete integer-order Output Error model form. The optimal input design is executed using finite-dimensional FIR (Finite Impulse Response) filter spectrum parameterization, where the decision variables are calculated through convex optimization. The A-optimality criterion has been used to examine the relationship between the input signal spectrum power and the accuracy of estimated models. Finally, numerical examples illustrate the proposed approach, confirming the method’s suitability for fractional-order system identification.
- 29 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12665
Open AccessOptimal Input Design for Fractional-Order System Identification Using an LMI-Based Frequency Error Criterion
This paper presents a novel approach to optimal input signal design for open-loop fractional-order system identification, using an integer-order approximation of the fractional operators to minimize the average input power. This is obtained by formulating the problem as an LMI (Linear Matrix Inequality) optimization problem with the limitation of achieving at least a specified model accuracy. The ORA (Oustaloup Recursive Approximation) method has been employed to model the fractional-order differentiation operator in discrete integer-order Output Error model form. The optimal input design is executed using finite-dimensional FIR (Finite Impulse Response) filter spectrum parameterization, where the decision variables are calculated through convex optimization. The A-optimality criterion has been used to examine the relationship between the input signal spectrum power and the accuracy of estimated models. Finally, numerical examples illustrate the proposed approach, confirming the method’s suitability for fractional-order system identification.
- Open Access
- 28 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (11) , 6552
Application-Oriented Input Spectrum Design in Closed-Loop Identification
In the paper, a problem of real-time input design, where the spectral characteristic of the external excitation signal is optimized considering the fixed bound on the ellipsoidal constraint applied to the quality measure of the estimated model, has been presented. We designed a compensator close to the complementary sensitivity function such that the resulting closed-loop system is stable and guarantees robust performance. The contribution of this work comprises a comparison of the KYP and frequency grid methods for the worst-case minimization between the identified plant and all models in the uncertainty region. It has been noted that the input design problem considering the frequency grid is far more numerically robust than the KYP method and guarantees that more than 90% of the estimated model parameters are clustered inside the assumed confidence region. The proposed approach is verified by numerical examples, and the sensitivity of the input spectrum design to the estimates of model parameters is discussed.
- 28 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (11) , 6552
Open AccessApplication-Oriented Input Spectrum Design in Closed-Loop Identification
In the paper, a problem of real-time input design, where the spectral characteristic of the external excitation signal is optimized considering the fixed bound on the ellipsoidal constraint applied to the quality measure of the estimated model, has been presented. We designed a compensator close to the complementary sensitivity function such that the resulting closed-loop system is stable and guarantees robust performance. The contribution of this work comprises a comparison of the KYP and frequency grid methods for the worst-case minimization between the identified plant and all models in the uncertainty region. It has been noted that the input design problem considering the frequency grid is far more numerically robust than the KYP method and guarantees that more than 90% of the estimated model parameters are clustered inside the assumed confidence region. The proposed approach is verified by numerical examples, and the sensitivity of the input spectrum design to the estimates of model parameters is discussed.
- Open Access
- 27 December 2022
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 70 (6) , 143646
Cascade tanks system identification for robust predictive control
The main goal of estimating models for industrial applications is to guarantee the cheapest system identification. The requirements for the identification experiment should not be allowed to affect product quality under normal operating conditions. This paper deals with ensuring the required liquid levels of the cascade system tanks using the model predictive control (MPC) method. The MPC strategy was extended with the Kalman filter (KF) to predict the system’s succeeding states subject to a reference trajectory in the presence of both process and measurement noise covariances. The main contribution is to use the application-oriented input design to update the parameters of the model during system degradation. This framework delivers the least-costly identification experiment and guarantees high performance of the system with the updated model. The methods presented are evaluated both in the experiments on a real process and in the computer simulations. The results of the robust MPC application for cascade system water levels control are discussed.
- 27 December 2022
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 70 (6) , 143646
Open AccessCascade tanks system identification for robust predictive control
The main goal of estimating models for industrial applications is to guarantee the cheapest system identification. The requirements for the identification experiment should not be allowed to affect product quality under normal operating conditions. This paper deals with ensuring the required liquid levels of the cascade system tanks using the model predictive control (MPC) method. The MPC strategy was extended with the Kalman filter (KF) to predict the system’s succeeding states subject to a reference trajectory in the presence of both process and measurement noise covariances. The main contribution is to use the application-oriented input design to update the parameters of the model during system degradation. This framework delivers the least-costly identification experiment and guarantees high performance of the system with the updated model. The methods presented are evaluated both in the experiments on a real process and in the computer simulations. The results of the robust MPC application for cascade system water levels control are discussed.
- 17 September 2021
- Published by Springer Nature
- p. 381-393
Fractional-Order Nonlinear System Identification Using MPC Technique
- 17 September 2021
- Published by Springer Nature
- p. 381-393
Fractional-Order Nonlinear System Identification Using MPC Technique
- Open Access
- 31 August 2020
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 68 (4) , 883-891
Application-oriented experiment design for model predictive control
The model predictive control (MPC) technique has been widely applied in a large number of industrial plants. Optimal input design should guarantee acceptable model parameter estimates while still providing for low experimental effort. The goal of this work is to investigate an application-oriented identification experiment that satisfies the performance objectives of the implementation of the model. A- and D-optimal input signal design methods for a non-linear liquid two-tank model are presented in this paper. The excitation signal is obtained using a finite impulse response filter (FIR) with respect to the accepted application degradation and the input power constraint. The MPC controller is then used to control the liquid levels of the double tank system subject to the reference trajectory. The MPC scheme is built based on the linearized and discretized model of the system to predict the system’s succeeding outputs with reference to the future input signal. The novelty of this model-based method consists in including the experiment cost in input design through the objective function. The proposed framework is illustrated by means of numerical examples, and simulation results are discussed.
- 31 August 2020
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 68 (4) , 883-891
Open AccessApplication-oriented experiment design for model predictive control
The model predictive control (MPC) technique has been widely applied in a large number of industrial plants. Optimal input design should guarantee acceptable model parameter estimates while still providing for low experimental effort. The goal of this work is to investigate an application-oriented identification experiment that satisfies the performance objectives of the implementation of the model. A- and D-optimal input signal design methods for a non-linear liquid two-tank model are presented in this paper. The excitation signal is obtained using a finite impulse response filter (FIR) with respect to the accepted application degradation and the input power constraint. The MPC controller is then used to control the liquid levels of the double tank system subject to the reference trajectory. The MPC scheme is built based on the linearized and discretized model of the system to predict the system’s succeeding outputs with reference to the future input signal. The novelty of this model-based method consists in including the experiment cost in input design through the objective function. The proposed framework is illustrated by means of numerical examples, and simulation results are discussed.
- Open Access
Robustness Analysis of the Estimators for the Nonlinear System Identification
The main objective of the system identification is to deliver maximum information about the system dynamics, while still ensuring an acceptable cost of the identification experiment. The focus of such an idea is to design an appropriate experiment so that the departure from normal working conditions during the identification task is minimized. In this paper, the adaptive filtering (AF) scheme for plant model parameter estimation is proposed. The experimental results are obtained using the nonlinear interacting water tanks system. The adaptive filtering is expressed by minimizing the error between the system and the plant model outputs subject to the white noise signal affecting system output. This measurement error is quantified by the comparison of Minimum Error Entropy Renyi (MEER), Least Entropy Like (LEL), Least Squares (LS), and Least Absolute Deviation (LAD) estimators, respectively. The plant model parameters were obtained using sequential quadratic programming (SQP) algorithm. The robustness tests for the double-tank water system parameter estimators are performed using the ellipsoidal confidence regions. The effectiveness analysis for the above-mentioned estimators relies on the total number of iterations and the number of function evaluation comparisons. The main contribution of this paper is the evaluation of different estimation methods for the nonlinear system identification using various excitation signals. The proposed empirical study is illustrated by the numerical examples, and the simulation results are discussed.
Open AccessRobustness Analysis of the Estimators for the Nonlinear System Identification
The main objective of the system identification is to deliver maximum information about the system dynamics, while still ensuring an acceptable cost of the identification experiment. The focus of such an idea is to design an appropriate experiment so that the departure from normal working conditions during the identification task is minimized. In this paper, the adaptive filtering (AF) scheme for plant model parameter estimation is proposed. The experimental results are obtained using the nonlinear interacting water tanks system. The adaptive filtering is expressed by minimizing the error between the system and the plant model outputs subject to the white noise signal affecting system output. This measurement error is quantified by the comparison of Minimum Error Entropy Renyi (MEER), Least Entropy Like (LEL), Least Squares (LS), and Least Absolute Deviation (LAD) estimators, respectively. The plant model parameters were obtained using sequential quadratic programming (SQP) algorithm. The robustness tests for the double-tank water system parameter estimators are performed using the ellipsoidal confidence regions. The effectiveness analysis for the above-mentioned estimators relies on the total number of iterations and the number of function evaluation comparisons. The main contribution of this paper is the evaluation of different estimation methods for the nonlinear system identification using various excitation signals. The proposed empirical study is illustrated by the numerical examples, and the simulation results are discussed.
- 11 August 2019
- Published by Springer Nature
- p. 457-468
Design of a State Estimation Considering Model Predictive Control Strategy for a Nonlinear Water Tanks Process
- 11 August 2019
- Published by Springer Nature
- p. 457-468
Design of a State Estimation Considering Model Predictive Control Strategy for a Nonlinear Water Tanks Process
- 17 April 2019
- Published by Springer Nature
- p. 128-141
Design of an Optimal Input Signal for Parameter Estimation of Linear Fractional-Order Systems
- 17 April 2019
- Published by Springer Nature
- p. 128-141
Design of an Optimal Input Signal for Parameter Estimation of Linear Fractional-Order Systems
- Open Access
- 28 February 2019
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 67 (1) , 37-44
Optimal input signal design for fractional-order system identification
The optimal design of excitation signal is a procedure of generating an informative input signal to extract the model parameters with maximum pertinence during the identification process. The fractional calculus provides many new possibilities for system modeling based on the definition of a derivative of noninteger-order. A novel optimal input design methodology for fractional-order systems identification is presented in the paper. The Oustaloup recursive approximation (ORA) method is used to obtain the fractional-order differentiation in an integer order state-space representation. Then, the presented methodology is utilized to solve optimal input design problem for fractional-order system identification. The fundamental objective of this approach is to design an input signal that yields maximum information on the value of the fractional-order model parameters to be estimated. The method described in this paper was verified using a numerical example, and the computational results were discussed.
- 28 February 2019
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 67 (1) , 37-44
Open AccessOptimal input signal design for fractional-order system identification
The optimal design of excitation signal is a procedure of generating an informative input signal to extract the model parameters with maximum pertinence during the identification process. The fractional calculus provides many new possibilities for system modeling based on the definition of a derivative of noninteger-order. A novel optimal input design methodology for fractional-order systems identification is presented in the paper. The Oustaloup recursive approximation (ORA) method is used to obtain the fractional-order differentiation in an integer order state-space representation. Then, the presented methodology is utilized to solve optimal input design problem for fractional-order system identification. The fundamental objective of this approach is to design an input signal that yields maximum information on the value of the fractional-order model parameters to be estimated. The method described in this paper was verified using a numerical example, and the computational results were discussed.