Alessandra Tini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alessandra Tini has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Christian Bolesch
Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland.
1 shared publication - Christoph Glanzmann
Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
1 shared publication - Christoph Oehler
Department of Radiation Oncology, Kantonsspital Winterthur, 8400 Winterthur, Switzerland
1 shared publication - Daniel R. Zwahlen
Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
1 shared publication - Gabriela Studer
Faculty of Health Sciences & Medicine, University of Lucerne, Frohburgstrasse 3, 6002 Luzern, Switzerland
1 shared publication - Peter Dimmerling
Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland.
1 shared publication
Latest Publications
- Open Access
- 11 November 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 229
PTV margin definition in hypofractionated IGRT of localized prostate cancer using cone beam CT and orthogonal image pairs with fiducial markers
To evaluate PTV margins for hypofractionated IGRT of prostate comparing kV/kV imaging or CBCT. Between 2009 and 2012, 20 patients with low- (LR), intermediate- (IR) and high-risk (HR) prostate cancer were treated with VMAT in supine position with fiducial markers (FM), endorectal balloon (ERB) and full bladder. CBCT’s and kV/kV imaging were performed before and additional CBCT’s after treatment assessing intra-fraction motion. CTVP for 5 patients with LR and CTVPSV for 5 patients with IR/HR prostate cancer were contoured independently by 3 radiation oncologists using MRI. The van Hark formula (PTV margin =2.5Σ +0.7σ) was applied to calculate PTV margins of prostate/seminal vesicles (P/PSV) using CBCT or FM. 172 and 52 CBCTs before and after RT and 507 kV/kV images before RT were analysed. Differences between FM in CBCT or in planar kV image pairs were below 1 mm. Accounting for both random and systematic uncertainties anisotropic PTV margins were 5-8 mm for P (LR) and 6-11 mm for PSV (IR/HR). Random uncertainties like intra-fraction and inter-fraction (setup) uncertainties were of similar magnitude (0.9-1.4 mm). Largest uncertainty was introduced by CTV delineation (LR: 1-2 mm, IR/HR: 1.6-3.5 mm). Patient positioning using bone matching or ERB-matching resulted in larger PTV margins. For IGRT CBCT or kV/kV-image pairs with FM are interchangeable in respect of accuracy. Especially for hypofractionated RT, PTV margins can be kept in the range of 5 mm or below if stringent daily IGRT, ideally including prostate tracking, is applied. MR-based CTV delineation optimization is recommended.
- 11 November 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 229
Open AccessPTV margin definition in hypofractionated IGRT of localized prostate cancer using cone beam CT and orthogonal image pairs with fiducial markers
To evaluate PTV margins for hypofractionated IGRT of prostate comparing kV/kV imaging or CBCT. Between 2009 and 2012, 20 patients with low- (LR), intermediate- (IR) and high-risk (HR) prostate cancer were treated with VMAT in supine position with fiducial markers (FM), endorectal balloon (ERB) and full bladder. CBCT’s and kV/kV imaging were performed before and additional CBCT’s after treatment assessing intra-fraction motion. CTVP for 5 patients with LR and CTVPSV for 5 patients with IR/HR prostate cancer were contoured independently by 3 radiation oncologists using MRI. The van Hark formula (PTV margin =2.5Σ +0.7σ) was applied to calculate PTV margins of prostate/seminal vesicles (P/PSV) using CBCT or FM. 172 and 52 CBCTs before and after RT and 507 kV/kV images before RT were analysed. Differences between FM in CBCT or in planar kV image pairs were below 1 mm. Accounting for both random and systematic uncertainties anisotropic PTV margins were 5-8 mm for P (LR) and 6-11 mm for PSV (IR/HR). Random uncertainties like intra-fraction and inter-fraction (setup) uncertainties were of similar magnitude (0.9-1.4 mm). Largest uncertainty was introduced by CTV delineation (LR: 1-2 mm, IR/HR: 1.6-3.5 mm). Patient positioning using bone matching or ERB-matching resulted in larger PTV margins. For IGRT CBCT or kV/kV-image pairs with FM are interchangeable in respect of accuracy. Especially for hypofractionated RT, PTV margins can be kept in the range of 5 mm or below if stringent daily IGRT, ideally including prostate tracking, is applied. MR-based CTV delineation optimization is recommended.