Charles Whitford
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Charles Whitford has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Elsheikh
Oujiang Laboratory (Zhejiang Lab for Regenerative Medicine, Vision, and Brain Health), Wenzhou,325001, China; School of Engineering, University of Liverpool, Liverpool, L69 7ZX, UK; National Institute for Health Research (NIHR) Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK
2 shared publications Ahmed Elsheikh
School of Engineering, University of Liverpool, Liverpool, L69 3GH, UK
1 shared publication- Akram Joda
Faculty of Engineering, Higher Colleges of Technology, Dubai P.O. Box 15825, United Arab Emirates
1 shared publication - Charles William McMonnies
University of New South Wales
1 shared publication - Craig Boote
Structural Biophysics Research Group, School of Optometry and Vision Sciences, Cardiff University, Cardiff, United Kingdom
1 shared publication Fangjun Bao
Eye Hospital, WenZhou Medical University, WenZhou, China
1 shared publication
Latest Publications
- Open Access
- 10 August 2016
- Published by Springer Nature in Eye and Vision
- Vol. 3 (1) , 1-12
Ex vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness
The eye globe exhibits significant regional variation of mechanical behaviour. The aim of this present study is to develop a new experimental technique for testing intact eye globes in a form that is representative of in vivo conditions, and therefore suitable for determining the material properties of the complete outer ocular tunic. A test rig has been developed to provide closed-loop control of either applied intra-ocular pressure or resulting apical displacement; measurement of displacements across the external surface of the eye globe using high-resolution digital cameras and digital image correlation software; prevention of rigid-body motion and protection of the ocular surface from environmental drying. The method has been demonstrated on one human and one porcine eye globe, which were cyclically loaded. Finite element models based on specimen specific tomography, free from rotational symmetry, were used along with experimental pressure-displacement data in an inverse analysis process to derive the mechanical properties of tissue in different regions of the eye’s outer tunic. The test method enabled monitoring of mechanical response to intraocular pressure variation across the surface of the eye globe. For the two eyes tested, the method showed a gradual change in the sclera’s stiffness from a maximum at the limbus to a minimum at the posterior pole, while in the cornea the stiffness was highest at the centre and lowest in the peripheral zone. Further, for both the sclera and cornea, the load–displacement behaviour did not vary significantly between loading cycles. The first methodology capable of mechanically testing intact eye globes, with applied loads and boundary conditions that closely represent in vivo conditions is introduced. The method enables determination of the regional variation in mechanical behaviour across the ocular surface.
- 10 August 2016
- Published by Springer Nature in Eye and Vision
- Vol. 3 (1) , 1-12
Open AccessEx vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness
The eye globe exhibits significant regional variation of mechanical behaviour. The aim of this present study is to develop a new experimental technique for testing intact eye globes in a form that is representative of in vivo conditions, and therefore suitable for determining the material properties of the complete outer ocular tunic. A test rig has been developed to provide closed-loop control of either applied intra-ocular pressure or resulting apical displacement; measurement of displacements across the external surface of the eye globe using high-resolution digital cameras and digital image correlation software; prevention of rigid-body motion and protection of the ocular surface from environmental drying. The method has been demonstrated on one human and one porcine eye globe, which were cyclically loaded. Finite element models based on specimen specific tomography, free from rotational symmetry, were used along with experimental pressure-displacement data in an inverse analysis process to derive the mechanical properties of tissue in different regions of the eye’s outer tunic. The test method enabled monitoring of mechanical response to intraocular pressure variation across the surface of the eye globe. For the two eyes tested, the method showed a gradual change in the sclera’s stiffness from a maximum at the limbus to a minimum at the posterior pole, while in the cornea the stiffness was highest at the centre and lowest in the peripheral zone. Further, for both the sclera and cornea, the load–displacement behaviour did not vary significantly between loading cycles. The first methodology capable of mechanically testing intact eye globes, with applied loads and boundary conditions that closely represent in vivo conditions is introduced. The method enables determination of the regional variation in mechanical behaviour across the ocular surface.
- Open Access
- 10 December 2015
- Published by Springer Nature in Eye and Vision
- Vol. 2 (1) , 1-10
In vivo study of corneal responses to increased intraocular pressure loading
- 10 December 2015
- Published by Springer Nature in Eye and Vision
- Vol. 2 (1) , 1-10
Open AccessIn vivo study of corneal responses to increased intraocular pressure loading