Salam K. Al-Dawery
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Salam K. Al-Dawery has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Nasser Ben Harharah Hamed
Department of Chemical Engineering, College of Engineering, King Khalid University, Abha 62223, Saudi Arabia
4 shared publications - Ramzi H. Harharah
Department of Chemical and Process Engineering, Faculty of Engineering & Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia
4 shared publications - Gasim Hayder
Department of Civil and Environmental Engineering, College of Engineering and Architecture, University of Nizwa, Birkat Al Mouz, Nizwa 616, Oman
3 shared publications - Saima Farooq
Department of Biological Sciences and Chemistry College of Arts and Sciences University of Nizwa Nizwa Oman
2 shared publications - Abdelfattah Amari
Department of Chemical Engineering, College of Engineering, King Khalid University, Abha 61411, Saudi Arabia
1 shared publication - Abdus Sami
Centre of Excellence in Solid State Physics, University of Punjab, Lahore 54590, Pakistan
1 shared publication
Latest Publications
- Open Access
- 19 July 2025
- Published by Al-Nahrain Journal for Engineering Sciences in Al-Nahrain Journal for Engineering Sciences
- Vol. 28 (2) , 253-265
Mathematical Modeling and Advanced Control of the Refinery Processes: A Review
The oil industry has a direct impact on the economic feasibility of other sectors and is considered to be the most important energy source used to turn the wheels of other industries. Therefore, it was necessary to pay attention and continuously develop this industry, to find the best modern techniques for designing, pre-commissioning and controlling process, to improve efficiency, preserve energy and achieve the highest production of costly components with the highest purity of the product. This study aims to provide a literary analysis of the stages of development and progress of the dynamics and control of the petroleum industry, in particular the distillation column, because it is multivariable with high interaction between control cycles, nonlinear behaviour and large gains. Control processes have undergone many developments and modernizations to achieve the best results. Various control methods have been used, ranging from simple proportional-integral-derivative controller (PID) to advanced control strategies such as model predictive control (MPC), multivariate model predictive control (MMPC), fuzzy logic control (FLC), quadratic dynamic matrix control (QDMC), artificial neural network control (ANN) and other advanced control techniques. The authors concluded from the review that the advanced control strategies superior than the conventional methods.
- 19 July 2025
- Published by Al-Nahrain Journal for Engineering Sciences in Al-Nahrain Journal for Engineering Sciences
- Vol. 28 (2) , 253-265
Open AccessMathematical Modeling and Advanced Control of the Refinery Processes: A Review
The oil industry has a direct impact on the economic feasibility of other sectors and is considered to be the most important energy source used to turn the wheels of other industries. Therefore, it was necessary to pay attention and continuously develop this industry, to find the best modern techniques for designing, pre-commissioning and controlling process, to improve efficiency, preserve energy and achieve the highest production of costly components with the highest purity of the product. This study aims to provide a literary analysis of the stages of development and progress of the dynamics and control of the petroleum industry, in particular the distillation column, because it is multivariable with high interaction between control cycles, nonlinear behaviour and large gains. Control processes have undergone many developments and modernizations to achieve the best results. Various control methods have been used, ranging from simple proportional-integral-derivative controller (PID) to advanced control strategies such as model predictive control (MPC), multivariate model predictive control (MMPC), fuzzy logic control (FLC), quadratic dynamic matrix control (QDMC), artificial neural network control (ANN) and other advanced control techniques. The authors concluded from the review that the advanced control strategies superior than the conventional methods.
- Open Access
- 19 July 2025
- Published by Al-Nahrain Journal for Engineering Sciences in Al-Nahrain Journal for Engineering Sciences
- Vol. 28 (2) , 195-204
Crude Oil Demulsification Using Electro-Coalescence Method: A Comprehensive Review
The separation of water from crude oil emulsions is a critical and complex challenge in petroleum production and processing. Water-in-oil (W/O) emulsions increase viscosity, pose corrosion risks, reduce refining efficiency, and raise significant environmental concerns. Traditional separation methods often struggle with stable emulsions containing small droplets due to limitations in cost, environmental impact, and effectiveness. Electro-coalescence demulsification has emerged as a promising technique that applies electric fields to enhance droplet coalescence, facilitating efficient water removal. This comprehensive review examines the influence of electrode geometry on electro-coalescence systems in depth, synthesizes key findings from numerous studies, and provides a detailed analysis of electrode spacing calculations, critical conditions for effective demulsification, and optimal operational parameters. By exploring these aspects comprehensively, the review offers insights into how electrode design affects demulsification efficiency, guiding future advancements in crude oil processing and contributing to more sustainable practices in the petroleum industry.
- 19 July 2025
- Published by Al-Nahrain Journal for Engineering Sciences in Al-Nahrain Journal for Engineering Sciences
- Vol. 28 (2) , 195-204
Open AccessCrude Oil Demulsification Using Electro-Coalescence Method: A Comprehensive Review
The separation of water from crude oil emulsions is a critical and complex challenge in petroleum production and processing. Water-in-oil (W/O) emulsions increase viscosity, pose corrosion risks, reduce refining efficiency, and raise significant environmental concerns. Traditional separation methods often struggle with stable emulsions containing small droplets due to limitations in cost, environmental impact, and effectiveness. Electro-coalescence demulsification has emerged as a promising technique that applies electric fields to enhance droplet coalescence, facilitating efficient water removal. This comprehensive review examines the influence of electrode geometry on electro-coalescence systems in depth, synthesizes key findings from numerous studies, and provides a detailed analysis of electrode spacing calculations, critical conditions for effective demulsification, and optimal operational parameters. By exploring these aspects comprehensively, the review offers insights into how electrode design affects demulsification efficiency, guiding future advancements in crude oil processing and contributing to more sustainable practices in the petroleum industry.
- Open Access
Engineered Cu0.5Ni0.5Al2O4/GCN Spinel Nanostructures for Dual-Functional Energy Storage and Electrocatalytic Water Splitting
The rapid growth in population and industrialization have significantly increased global energy demand, placing immense pressure on finite and environmentally harmful conventional fossil fuel-based energy sources. In this context, the development of hybrid electrocatalysts presents a crucial solution for energy conversion and storage, addressing environmental challenges while meeting rising energy needs. In this study, the fabrication of a novel bifunctional catalyst, copper nickel aluminum spinel (Cu0.5Ni0.5Al2O4) supported on graphitic carbon nitride (GCN), using a solid-state synthesis process is reported. Because of its effective interface design and spinel cubic structure, the Cu0.5Ni0.5Al2O4/GCN nanocomposite, as synthesized, performs exceptionally well in electrochemical energy conversion, such as the oxygen evolution reaction (OER), the hydrogen evolution reaction (HER), and energy storage. In particular, compared to noble metals, Pt/C- and IrO2-based water-splitting cells require higher voltages (1.70 V), while for the Cu0.5Ni0.5Al2O4/GCN nanocomposite, a voltage of 1.49 V is sufficient to generate a current density of 10 mA cm−2 in an alkaline solution. When used as supercapacitor electrode materials, Cu0.5Ni0.5Al2O4/GCN nanocomposites show a specific capacitance of 1290 F g−1 at a current density of 1 A g−1 and maintain a specific capacitance of 609 F g−1 even at a higher current density of 5 A g−1, suggesting exceptional rate performance and charge storage capacity. The electrode’s exceptional capacitive properties were further confirmed through the determination of the roughness factor (Rf), which represents surface heterogeneity and active area enhancement, with a value of 345.5. These distinctive characteristics render the Cu0.5Ni0.5Al2O4/GCN composite a compelling alternative to fossil fuels in the ongoing quest for a viable replacement. Undoubtedly, the creation of the Cu0.5Ni0.5Al2O4/GCN composite represents a significant breakthrough in addressing the energy crisis and environmental concerns. Owing to its unique composition and electrocatalytic characteristics, it is considered a feasible choice in the pursuit of ecologically sustainable alternatives to fossil fuels.
Open AccessEngineered Cu0.5Ni0.5Al2O4/GCN Spinel Nanostructures for Dual-Functional Energy Storage and Electrocatalytic Water Splitting
The rapid growth in population and industrialization have significantly increased global energy demand, placing immense pressure on finite and environmentally harmful conventional fossil fuel-based energy sources. In this context, the development of hybrid electrocatalysts presents a crucial solution for energy conversion and storage, addressing environmental challenges while meeting rising energy needs. In this study, the fabrication of a novel bifunctional catalyst, copper nickel aluminum spinel (Cu0.5Ni0.5Al2O4) supported on graphitic carbon nitride (GCN), using a solid-state synthesis process is reported. Because of its effective interface design and spinel cubic structure, the Cu0.5Ni0.5Al2O4/GCN nanocomposite, as synthesized, performs exceptionally well in electrochemical energy conversion, such as the oxygen evolution reaction (OER), the hydrogen evolution reaction (HER), and energy storage. In particular, compared to noble metals, Pt/C- and IrO2-based water-splitting cells require higher voltages (1.70 V), while for the Cu0.5Ni0.5Al2O4/GCN nanocomposite, a voltage of 1.49 V is sufficient to generate a current density of 10 mA cm−2 in an alkaline solution. When used as supercapacitor electrode materials, Cu0.5Ni0.5Al2O4/GCN nanocomposites show a specific capacitance of 1290 F g−1 at a current density of 1 A g−1 and maintain a specific capacitance of 609 F g−1 even at a higher current density of 5 A g−1, suggesting exceptional rate performance and charge storage capacity. The electrode’s exceptional capacitive properties were further confirmed through the determination of the roughness factor (Rf), which represents surface heterogeneity and active area enhancement, with a value of 345.5. These distinctive characteristics render the Cu0.5Ni0.5Al2O4/GCN composite a compelling alternative to fossil fuels in the ongoing quest for a viable replacement. Undoubtedly, the creation of the Cu0.5Ni0.5Al2O4/GCN composite represents a significant breakthrough in addressing the energy crisis and environmental concerns. Owing to its unique composition and electrocatalytic characteristics, it is considered a feasible choice in the pursuit of ecologically sustainable alternatives to fossil fuels.
- Open Access
Carbon Dioxide Capture by Alkaline Water with a Semi-Batch Column and Ultra-Fine Microbubble Generator
Increased emissions of carbon dioxide (CO2) from industrial activities are the main cause of the growing problem of global warming and climate change, highlighting the needs for efficient CO2 capture and storage (CCS) techniques. The present work aims to investigate the possibility of CO2 sequestration using sodium hydroxide (NaOH) in a semi-batch column with an integrated gas lift tower and an ultra-micro bubbles generator, a novel setup designed to enhance mass transfer rates and capture efficiency. Unlike the previously reported setups, our system achieves a 50% faster capture rate with improved mass transfer, enhanced gas-liquid interaction and higher removal efficiency due to finer bubble dispersion, as confirmed by experimental findings. Preliminary tests to ascertain the effectiveness of CO2 removal were carried out across various CO2 gas flow rates (3, 5, 7 L/min), NaOH volumes (2, 3, 4 L) and concentrations (0.1, 0.2, 0.3 M). The results indicated that both gas flow rate and NaOH concentration have profound impacts on the CO2 capture rate. Increasing either of these parameters, or using low concentrations of NaOH, leads to a rapid drop in pH due to a faster rate of neutralization and the formation of carbonic acid (H2CO3), a weak acidic solution. For instance, with 0.1 M NaOH and 2 L volume, the pH decreased from 13.07 to 7.02 within 1.5 min at gas flow rate of 7 L/min, while with 0.3 M NaOH, pH reduced to 7.3 after 6 min. Higher volumes and concentrations of NaOH caused a decrease in the capture rate of CO2 due to reversed reaction with formed sodium carbonate. For instance, with 0.3 M NaOH and 4 L volume, the pH reduced from 13.58 to 8 after 5 min at 7 L/min gas flow rate. Scaling up to a 100 L semi-batch column with an ultra-fine micro bubble generator, as a new approach, reduced the time taken by half in the capture of CO2. Additionally, the study also investigated the comparison of tap versus deionized water in CO2 capture reaction. The results demonstrated that dissolved minerals in tap water, particularly Ca2+ and Mg2+ ions, affected precipitate formation and capture efficiency differently than deionized water, offering practical insights for CCS in varied water sources.
Open AccessCarbon Dioxide Capture by Alkaline Water with a Semi-Batch Column and Ultra-Fine Microbubble Generator
Increased emissions of carbon dioxide (CO2) from industrial activities are the main cause of the growing problem of global warming and climate change, highlighting the needs for efficient CO2 capture and storage (CCS) techniques. The present work aims to investigate the possibility of CO2 sequestration using sodium hydroxide (NaOH) in a semi-batch column with an integrated gas lift tower and an ultra-micro bubbles generator, a novel setup designed to enhance mass transfer rates and capture efficiency. Unlike the previously reported setups, our system achieves a 50% faster capture rate with improved mass transfer, enhanced gas-liquid interaction and higher removal efficiency due to finer bubble dispersion, as confirmed by experimental findings. Preliminary tests to ascertain the effectiveness of CO2 removal were carried out across various CO2 gas flow rates (3, 5, 7 L/min), NaOH volumes (2, 3, 4 L) and concentrations (0.1, 0.2, 0.3 M). The results indicated that both gas flow rate and NaOH concentration have profound impacts on the CO2 capture rate. Increasing either of these parameters, or using low concentrations of NaOH, leads to a rapid drop in pH due to a faster rate of neutralization and the formation of carbonic acid (H2CO3), a weak acidic solution. For instance, with 0.1 M NaOH and 2 L volume, the pH decreased from 13.07 to 7.02 within 1.5 min at gas flow rate of 7 L/min, while with 0.3 M NaOH, pH reduced to 7.3 after 6 min. Higher volumes and concentrations of NaOH caused a decrease in the capture rate of CO2 due to reversed reaction with formed sodium carbonate. For instance, with 0.3 M NaOH and 4 L volume, the pH reduced from 13.58 to 8 after 5 min at 7 L/min gas flow rate. Scaling up to a 100 L semi-batch column with an ultra-fine micro bubble generator, as a new approach, reduced the time taken by half in the capture of CO2. Additionally, the study also investigated the comparison of tap versus deionized water in CO2 capture reaction. The results demonstrated that dissolved minerals in tap water, particularly Ca2+ and Mg2+ ions, affected precipitate formation and capture efficiency differently than deionized water, offering practical insights for CCS in varied water sources.
- Open Access
Treatment of Sewage Sludge and Phosphorus Removal Using Polyacrylamide and Calcium Chloride
The enhancement of the treatment of municipal wastewater treatment plants is limited by poor sludge settling qualities, and the excessive discharge of nitrogen and phosphorus exacerbate water eutrophication. The goal of the current work was to remove phosphorus from fresh sewage-activated sludge by developing a new conditioning and flocculation mechanism that included a coagulant and cationic polyelectrolytes in a dual conditioning system. The coagulant (CaCl2) and the high molecular weight polyacrylamide (CPAM-10) were chosen to be utilized singly or in pairs as cationic–coagulant combinations. The collected results showed that, in comparison to utilizing the coagulant (CaCl2), conditioning with the high molecular weight polymer (CPAM-10) produced improved settling and less turbidity. Only sludge with a lower solid content (TSS) exhibited better settling when pure CaCl2 was used for conditioning. CaCl2 conditioning enhanced settling by just 3%, while CPAM-10 improved the sludge setting by 60% for higher sludge TSSs. According to the results, conditioning settings using a dual mixture including 20 mL CPAM-10 and 50 mL CaCl2 improved settling by 80%. The amount of phosphorus in the supernatant was decreased by 15% and 9%, respectively, by using the coagulant (CaCl2) and 50 mL/L polyacrylamide (CPAM-10). As a result, there was a significant amount of phosphorus in the resultant supernatant. This suggested that the polymer had a significant impact on sludge settling because of its high positive charge, but had less of an impact on attracting phosphorus metal. Despite the lower positive charge of CaCl2, it has a dual action of settling and removing phosphorus. A considerable amount of phosphorus was removed from the sludge and leached to the supernatant during treatment. This treatment was coupled with less sludge settling. However, 90% phosphorus removal was achieved when mixed conditioning agents (20 mL CPAM-10 and 50 mL CaCl2) were used. Furthermore, phosphorus was reduced by 33 and 39%, respectively, by adding 20 milliliters of CaCl2 to 100 milliliters of the pre-conditioned supernatant with pure CPAM-10 and CaCl2. Using the CPAM-10 agent for sludge conditioning has a major impact on settling, because of the high positive charge, and because when a small amount of Ca++ is added to the polymer solution for conditioning to attract fine sludge particles and accelerate their combination, this results in flocculation and rapid dewatering. This mechanism allows for more phosphorus to be released to the supernatant, which has not been reported previously to the best of our knowledge.
Open AccessTreatment of Sewage Sludge and Phosphorus Removal Using Polyacrylamide and Calcium Chloride
The enhancement of the treatment of municipal wastewater treatment plants is limited by poor sludge settling qualities, and the excessive discharge of nitrogen and phosphorus exacerbate water eutrophication. The goal of the current work was to remove phosphorus from fresh sewage-activated sludge by developing a new conditioning and flocculation mechanism that included a coagulant and cationic polyelectrolytes in a dual conditioning system. The coagulant (CaCl2) and the high molecular weight polyacrylamide (CPAM-10) were chosen to be utilized singly or in pairs as cationic–coagulant combinations. The collected results showed that, in comparison to utilizing the coagulant (CaCl2), conditioning with the high molecular weight polymer (CPAM-10) produced improved settling and less turbidity. Only sludge with a lower solid content (TSS) exhibited better settling when pure CaCl2 was used for conditioning. CaCl2 conditioning enhanced settling by just 3%, while CPAM-10 improved the sludge setting by 60% for higher sludge TSSs. According to the results, conditioning settings using a dual mixture including 20 mL CPAM-10 and 50 mL CaCl2 improved settling by 80%. The amount of phosphorus in the supernatant was decreased by 15% and 9%, respectively, by using the coagulant (CaCl2) and 50 mL/L polyacrylamide (CPAM-10). As a result, there was a significant amount of phosphorus in the resultant supernatant. This suggested that the polymer had a significant impact on sludge settling because of its high positive charge, but had less of an impact on attracting phosphorus metal. Despite the lower positive charge of CaCl2, it has a dual action of settling and removing phosphorus. A considerable amount of phosphorus was removed from the sludge and leached to the supernatant during treatment. This treatment was coupled with less sludge settling. However, 90% phosphorus removal was achieved when mixed conditioning agents (20 mL CPAM-10 and 50 mL CaCl2) were used. Furthermore, phosphorus was reduced by 33 and 39%, respectively, by adding 20 milliliters of CaCl2 to 100 milliliters of the pre-conditioned supernatant with pure CPAM-10 and CaCl2. Using the CPAM-10 agent for sludge conditioning has a major impact on settling, because of the high positive charge, and because when a small amount of Ca++ is added to the polymer solution for conditioning to attract fine sludge particles and accelerate their combination, this results in flocculation and rapid dewatering. This mechanism allows for more phosphorus to be released to the supernatant, which has not been reported previously to the best of our knowledge.
- Open Access
Treatment of Fish-Processing Wastewater Using Polyelectrolyte and Palm Anguish
Fish-process wastewater industries are a significant source of environmental pollutions and biohazard to humans and other living organisms due to suspended organics, phosphorus, and nitrate that causes environmental damage. In this study, the treatment of two types of fish wastewater was examined by applying chemical and physical methods. The chemical treatments using positive polyelectrolyte with a concentration of 25 ppm reduced the turbidity of fish wastewater by 50%; conductivity was reduced by 50% and pH was reduced from 8 to 7.2. Meanwhile, using negative polyelectrolyte and mixed polymers reduced the turbidity of fish wastewater by 30%. For applying natural material as a physical adsorbent, several natural materials were examined: ocimum leaves, Boswellia sacra leaves, Al-Shakher leaves, tephrosia leaves, neem leaves, mentha leaves, jand peel, neem wood, ocimum fruit, olive fruit peel, and palm anguish for the treatment of the fish wastewater. The initial tests indicated that the best material was palm anguish. FTIR, SEM, and EDS were used for the characterization of palm anguish. The selected material was treated with 1 M of NaOH solution. Different bed heights (10, 20, and 30 cm) of Palm anguish were applied. The results showed 80% and 85% reduction in the turbidity in both types of fish wastewater, especially with a bed height of 30 cm of the fish wastewater treated with NaOH, respectively. Notably, this study distinguishes itself by utilizing polyacrylamide flocculants of varying densities and by employing palm anguish as a natural adsorbent, which can sufficiently improve the treatment of fish-processing wastewater.
Open AccessTreatment of Fish-Processing Wastewater Using Polyelectrolyte and Palm Anguish
Fish-process wastewater industries are a significant source of environmental pollutions and biohazard to humans and other living organisms due to suspended organics, phosphorus, and nitrate that causes environmental damage. In this study, the treatment of two types of fish wastewater was examined by applying chemical and physical methods. The chemical treatments using positive polyelectrolyte with a concentration of 25 ppm reduced the turbidity of fish wastewater by 50%; conductivity was reduced by 50% and pH was reduced from 8 to 7.2. Meanwhile, using negative polyelectrolyte and mixed polymers reduced the turbidity of fish wastewater by 30%. For applying natural material as a physical adsorbent, several natural materials were examined: ocimum leaves, Boswellia sacra leaves, Al-Shakher leaves, tephrosia leaves, neem leaves, mentha leaves, jand peel, neem wood, ocimum fruit, olive fruit peel, and palm anguish for the treatment of the fish wastewater. The initial tests indicated that the best material was palm anguish. FTIR, SEM, and EDS were used for the characterization of palm anguish. The selected material was treated with 1 M of NaOH solution. Different bed heights (10, 20, and 30 cm) of Palm anguish were applied. The results showed 80% and 85% reduction in the turbidity in both types of fish wastewater, especially with a bed height of 30 cm of the fish wastewater treated with NaOH, respectively. Notably, this study distinguishes itself by utilizing polyacrylamide flocculants of varying densities and by employing palm anguish as a natural adsorbent, which can sufficiently improve the treatment of fish-processing wastewater.
- 19 March 2021
- Published by Springer Nature in International Journal of Environmental Science and Technology
- Vol. 18 (5) , 1097-1108
Parametric study for optimization of sediment-type microbial fuel cell
- 19 March 2021
- Published by Springer Nature in International Journal of Environmental Science and Technology
- Vol. 18 (5) , 1097-1108
Parametric study for optimization of sediment-type microbial fuel cell
- 1 April 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (10) , 10790-10801
Cost-effective treatment of sludge conditioning using supernatant fluid polyelectrolyte
Treatment of activated sludge using pure polyelectrolyte and its supernatant fluids for sludge dewatering was examined. The supernatant was used for treatment of fresh sludge for reducing the total cost of sludge conditioning by almost 50% and had great impact on wastewater treatment especially on that with large flow rate. The utilization of supernatant can be considered as a sustainable and economical method for pollution reduction especially in the developing countries. This would overcome the problem of imperfect mixing, difficulties in operated sludge conditioning, and utilized wasted polyelectrolyte. A slightly high positively charged polyelectrolyte was selected during this study. The results showed this polymer and the supernatant had significant influence on the sludge volume index (SVI) and sludge settling. The SVI and settling were improved by 50% and 60%, respectively. We found the sludge treated with supernatant showed a highest sludge settling properties compared with using pure polyelectrolyte especially for sludge samples with low total suspended solid (TSS) and SVI. Using mixed supernatant with pure polyelectrolyte showed higher settling compared to second treatment. Zeta potentials were measured, and increases in zeta potentials were observed for use of both pure polymer and supernatant fluids. The experiments of using supernatants for sludge treatment were found to reflect the use of waste for waste and principle of circulation cleaning; thus it can be a valuable reference for the researchers working in the field of sludge treatment.
- 1 April 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (10) , 10790-10801
Cost-effective treatment of sludge conditioning using supernatant fluid polyelectrolyte
Treatment of activated sludge using pure polyelectrolyte and its supernatant fluids for sludge dewatering was examined. The supernatant was used for treatment of fresh sludge for reducing the total cost of sludge conditioning by almost 50% and had great impact on wastewater treatment especially on that with large flow rate. The utilization of supernatant can be considered as a sustainable and economical method for pollution reduction especially in the developing countries. This would overcome the problem of imperfect mixing, difficulties in operated sludge conditioning, and utilized wasted polyelectrolyte. A slightly high positively charged polyelectrolyte was selected during this study. The results showed this polymer and the supernatant had significant influence on the sludge volume index (SVI) and sludge settling. The SVI and settling were improved by 50% and 60%, respectively. We found the sludge treated with supernatant showed a highest sludge settling properties compared with using pure polyelectrolyte especially for sludge samples with low total suspended solid (TSS) and SVI. Using mixed supernatant with pure polyelectrolyte showed higher settling compared to second treatment. Zeta potentials were measured, and increases in zeta potentials were observed for use of both pure polymer and supernatant fluids. The experiments of using supernatants for sludge treatment were found to reflect the use of waste for waste and principle of circulation cleaning; thus it can be a valuable reference for the researchers working in the field of sludge treatment.
- Open Access
- 14 January 2019
- Published by Springer Nature in Journal of Petroleum Exploration and Production Technology
- Vol. 9 (3) , 2109-2121
Waste bio materials based viscosity reduction and rheological properties of crude oil
- 14 January 2019
- Published by Springer Nature in Journal of Petroleum Exploration and Production Technology
- Vol. 9 (3) , 2109-2121
Open AccessWaste bio materials based viscosity reduction and rheological properties of crude oil
- 10 January 2019
- Published by AccScience Publishing in Asian Journal of Water, Environment and Pollution
- Vol. 16 (1) , 81-89
Removal of Phenol from Sewage Effluent Using Activated Sludge Coupled with Photo-oxidation Process
Treatment of hazardous phenolic substances that are discharged to environment has a significant interest since decades. Biological treatment using freely suspended sludge is the most economical treatment method, but, is considered inactive for treatment of phenolic substances due to the complexity in their chemical structure. The degradation of phenol was experimentally investigated using separate and coupled biological and photo-catalytic processes. The degradation was carried out at different concentrations of phenol from 10 to 100 ppm. The results showed no degradation of phenol using biological treatment, and as expected, the bacterial colony growth was reduced by 50 percent due to lack of nutrient. The results of photo-catalytic process using titanium dioxide (TiO2) indicated the removal of 80 percent of phenol especially for concentration below 40 ppm. Bacterial colony growth during photo-oxidation test was dramatically reduced and no colony growth was found after 90 minutes after commencing time of experiment. On this basis, the results of using the combined advanced oxidation process with biological treatment, suggested that the photo-catalytic process would be considered as a post-treatment to the biological process.
- 10 January 2019
- Published by AccScience Publishing in Asian Journal of Water, Environment and Pollution
- Vol. 16 (1) , 81-89
Removal of Phenol from Sewage Effluent Using Activated Sludge Coupled with Photo-oxidation Process
Treatment of hazardous phenolic substances that are discharged to environment has a significant interest since decades. Biological treatment using freely suspended sludge is the most economical treatment method, but, is considered inactive for treatment of phenolic substances due to the complexity in their chemical structure. The degradation of phenol was experimentally investigated using separate and coupled biological and photo-catalytic processes. The degradation was carried out at different concentrations of phenol from 10 to 100 ppm. The results showed no degradation of phenol using biological treatment, and as expected, the bacterial colony growth was reduced by 50 percent due to lack of nutrient. The results of photo-catalytic process using titanium dioxide (TiO2) indicated the removal of 80 percent of phenol especially for concentration below 40 ppm. Bacterial colony growth during photo-oxidation test was dramatically reduced and no colony growth was found after 90 minutes after commencing time of experiment. On this basis, the results of using the combined advanced oxidation process with biological treatment, suggested that the photo-catalytic process would be considered as a post-treatment to the biological process.