Dinesh Gundapaneni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Dinesh Gundapaneni has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Tarun Goswami
Department of Biomedical, Industrial, and Human Factors Engineering, Wright State University, Dayton, OH 45435, USA
7 shared publications Tarun Goswami
3 shared publicationsJames T. Tsatalis
Department of Radiology, Miami Valley Hospital, Dayton, OH, USA
2 shared publicationsRichard T. Laughlin
Department of Orthopedic Surgery, Sports Medicine and Rehabilitation, Miami Valley Hospital, Dayton, OH, USA
2 shared publicationsSommitsch Christof
Mechanical Engineering and Economic Sciences, Institute for Materials Science and Welding, Graz University of Technology, Kopernikusgasse 24/I, A-8010 Graz, Austria
2 shared publicationsAbdelaziz Y. Mohammad
Department of Biomedical and Industrial Engineering, Wright State University College of Engineering and Computer Science, Dayton, OH, USA
1 shared publication
Latest Publications
- Open Access
- 17 October 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (10) , 1212
Anthropomorphic Characterization of Ankle Joint
Even though total ankle replacement has emerged as an alternative treatment to arthrodesis, the long-term clinical results are unsatisfactory. Proper design of the ankle device is required to achieve successful arthroplasty results. Therefore, a quantitative knowledge of the ankle joint is necessary. In this pilot study, imaging data of 22 subjects (with both females and males and across three age groups) was used to measure the morphological parameters of the ankle joint. A total of 40 measurements were collected by creating sections in the sagittal and coronal planes for the tibia and talus. Statistical analyses were performed to compare genders, age groups, and image acquisition techniques used to generate 3D models. About 13 measurements derived for parameters (TiAL, SRTi, TaAL, SRTa, TiW, TaW, and TTL) that are very critical for the implant design showed significant differences (p-value < 0.05) between males and females. Young adults showed a significant difference (p-value < 0.05) compared to adults for 15 measurements related to critical tibial and talus parameters (TiAL, TiW, TML, TaAL, SRTa, TaW, and TTL), but no significant differences were observed between young adults and older adults, and between adults and older adults for most of the parameters. A positive correlation (r > 0.70) was observed between tibial and talar width values and between the sagittal radius values. When compared with morphological parameters obtained in this study, the sizes of current total ankle replacement devices can only fit a very limited group of people in this study. This pilot study contributes to the comprehensive understanding of the effects of gender and age group on ankle joint morphology and the relationship between tibial and talus parameters that can be used to plan and design ankle devices.
- 17 October 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (10) , 1212
Open AccessAnthropomorphic Characterization of Ankle Joint
Even though total ankle replacement has emerged as an alternative treatment to arthrodesis, the long-term clinical results are unsatisfactory. Proper design of the ankle device is required to achieve successful arthroplasty results. Therefore, a quantitative knowledge of the ankle joint is necessary. In this pilot study, imaging data of 22 subjects (with both females and males and across three age groups) was used to measure the morphological parameters of the ankle joint. A total of 40 measurements were collected by creating sections in the sagittal and coronal planes for the tibia and talus. Statistical analyses were performed to compare genders, age groups, and image acquisition techniques used to generate 3D models. About 13 measurements derived for parameters (TiAL, SRTi, TaAL, SRTa, TiW, TaW, and TTL) that are very critical for the implant design showed significant differences (p-value < 0.05) between males and females. Young adults showed a significant difference (p-value < 0.05) compared to adults for 15 measurements related to critical tibial and talus parameters (TiAL, TiW, TML, TaAL, SRTa, TaW, and TTL), but no significant differences were observed between young adults and older adults, and between adults and older adults for most of the parameters. A positive correlation (r > 0.70) was observed between tibial and talar width values and between the sagittal radius values. When compared with morphological parameters obtained in this study, the sizes of current total ankle replacement devices can only fit a very limited group of people in this study. This pilot study contributes to the comprehensive understanding of the effects of gender and age group on ankle joint morphology and the relationship between tibial and talus parameters that can be used to plan and design ankle devices.
- 2 January 2021
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 9 (1) , 4-27
Surface damage evaluation and computational modelling of clinically failed knee liners
Five retrieved knee liners made of cross-linked, ultra-high molecular weight polyethylene were investigated. Each liner was examined by five investigators and in vivo damage was evaluated using four methods (Wasielewski, Brandt, Lombardi, and Hood). Both optical and confocal microscopy techniques were used to quantify damage modes. Oxidation index, crystallinity and hardness parameters were calculated for material characterization. Gait profiles of two subjects (one male and one female) for three different activities were considered in finite element analysis (FEA) simulations. The main hypotheses of this study were that 1) the wear tracks on the liners may be represented by maximum von Mises stress areas, 2) a single composite index may be used to represent 10 different damage modes. Significant reduction in tensile strength was observed with an average value of 27.7 MPa at 50KGy due to oxidation in all the liners. Correlations were made between FEA results and surface evaluation results. Gait analysis of the liners showed males typically have a higher stress levelin vivothan females, leading to increased wear. Attempts were made to relate the damage patterns on the liners with the stress development and the damage evaluation methods and our computational simulation validates the methods that we used. Higher stress areas were compared against the surface evaluation results, showing those regions experiencing the high stress also had a high damage index. Even though the liners were mechanically intact, they failed clinically and more likely due to abrasive wear (due to third-body wear particles).
- 2 January 2021
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 9 (1) , 4-27
Surface damage evaluation and computational modelling of clinically failed knee liners
Five retrieved knee liners made of cross-linked, ultra-high molecular weight polyethylene were investigated. Each liner was examined by five investigators and in vivo damage was evaluated using four methods (Wasielewski, Brandt, Lombardi, and Hood). Both optical and confocal microscopy techniques were used to quantify damage modes. Oxidation index, crystallinity and hardness parameters were calculated for material characterization. Gait profiles of two subjects (one male and one female) for three different activities were considered in finite element analysis (FEA) simulations. The main hypotheses of this study were that 1) the wear tracks on the liners may be represented by maximum von Mises stress areas, 2) a single composite index may be used to represent 10 different damage modes. Significant reduction in tensile strength was observed with an average value of 27.7 MPa at 50KGy due to oxidation in all the liners. Correlations were made between FEA results and surface evaluation results. Gait analysis of the liners showed males typically have a higher stress levelin vivothan females, leading to increased wear. Attempts were made to relate the damage patterns on the liners with the stress development and the damage evaluation methods and our computational simulation validates the methods that we used. Higher stress areas were compared against the surface evaluation results, showing those regions experiencing the high stress also had a high damage index. Even though the liners were mechanically intact, they failed clinically and more likely due to abrasive wear (due to third-body wear particles).
- 18 May 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 7 (2) , 162-174
Simulation of ankle joint kinematics in sagittal plane using passive imaging data – a pilot study
Purpose: The purpose of this pilot study was to determine the radius of curvature of the tibia and talus, and to deduce ankle joint kinematics in the sagittal plane using passive imaging data. Methods: Imaging data of four subjects under passive conditions was used. Ligament positions were marked using MRI data to subscribe the four-bar linkage (FBL) mechanism at the ankle joint. Flexion motion of the assembly construct was simulated in the sagittal plane to determine the contact points on the tibial and talar dome surfaces. The radius of curvature was determined by fitting the contact points with a circle fit. Results: In addition to articular surfaces, calcaneofibular and tibiocalcaneal ligaments in the FBL play an important role in affecting the path of ankle joint motion. Two different linkage arrangements between the ligaments were observed in this study. The double-crank type arrangement by these ligaments generated the same contact path on the articular surface during dorsi- and plantarflexion, whereas the triple-rocker arrangement resulted in different paths. Conclusion: A higher order compliant mechanism, which includes additional ankle ligaments, needs to be developed and studied under load bearing conditions to achieve more accurate results.
- 18 May 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 7 (2) , 162-174
Simulation of ankle joint kinematics in sagittal plane using passive imaging data – a pilot study
Purpose: The purpose of this pilot study was to determine the radius of curvature of the tibia and talus, and to deduce ankle joint kinematics in the sagittal plane using passive imaging data. Methods: Imaging data of four subjects under passive conditions was used. Ligament positions were marked using MRI data to subscribe the four-bar linkage (FBL) mechanism at the ankle joint. Flexion motion of the assembly construct was simulated in the sagittal plane to determine the contact points on the tibial and talar dome surfaces. The radius of curvature was determined by fitting the contact points with a circle fit. Results: In addition to articular surfaces, calcaneofibular and tibiocalcaneal ligaments in the FBL play an important role in affecting the path of ankle joint motion. Two different linkage arrangements between the ligaments were observed in this study. The double-crank type arrangement by these ligaments generated the same contact path on the articular surface during dorsi- and plantarflexion, whereas the triple-rocker arrangement resulted in different paths. Conclusion: A higher order compliant mechanism, which includes additional ankle ligaments, needs to be developed and studied under load bearing conditions to achieve more accurate results.
- 1 December 2016
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 2 (6) , 065012
Applicability of PEEK and its composites in total ankle replacement devices and wear rate predictions
PEEK and carbon fiber reinforced PEEK (CFR-PEEK) materials have emerged as leading high-performance materials for replacing metal components in orthopedic devices. In this study these materials were critically evaluated as main load bearing components in total ankle replacement (TAR) devices. Wear characterization was determined by conducting finite element analysis on second generation Wright State University (WSU) TAR devices. Maximum von Mises stress value of 25.06 MPa was obtained for the optimized model with CFR-PEEK/UHMWPE as tibial/talar and bearing components, which is comparable with stress value of 26.85 MPa obtained for Ti-6Al-4V/UHMWPE material model. A similar trend was observed for contact stress values as well, where an average contact stress value of 6.61 MPa was obtained for CFR-PEEK/UHMWPE model which corresponds to a wear rate of 0.03 (mm 3 yr −1 ). Based on the obtained stress and wear results, and in the absence of PEEK debris causing osteolysis data, CFR-PEEK was recommended as a potential alternative to Titanium alloy in TAR devices. Further wear simulator testing is necessary to accurately determine the wear behavior of TAR models.
- 1 December 2016
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 2 (6) , 065012
Applicability of PEEK and its composites in total ankle replacement devices and wear rate predictions
PEEK and carbon fiber reinforced PEEK (CFR-PEEK) materials have emerged as leading high-performance materials for replacing metal components in orthopedic devices. In this study these materials were critically evaluated as main load bearing components in total ankle replacement (TAR) devices. Wear characterization was determined by conducting finite element analysis on second generation Wright State University (WSU) TAR devices. Maximum von Mises stress value of 25.06 MPa was obtained for the optimized model with CFR-PEEK/UHMWPE as tibial/talar and bearing components, which is comparable with stress value of 26.85 MPa obtained for Ti-6Al-4V/UHMWPE material model. A similar trend was observed for contact stress values as well, where an average contact stress value of 6.61 MPa was obtained for CFR-PEEK/UHMWPE model which corresponds to a wear rate of 0.03 (mm 3 yr −1 ). Based on the obtained stress and wear results, and in the absence of PEEK debris causing osteolysis data, CFR-PEEK was recommended as a potential alternative to Titanium alloy in TAR devices. Further wear simulator testing is necessary to accurately determine the wear behavior of TAR models.
- 1 December 2016
- Published by Elsevier in Engineering Failure Analysis
- Vol. 70, 237-254
Characterization of retrieved total ankle replacement liners
- 1 December 2016
- Published by Elsevier in Engineering Failure Analysis
- Vol. 70, 237-254
Characterization of retrieved total ankle replacement liners
- 1 January 2016
- Published by Elsevier in Engineering Failure Analysis
- Vol. 59, 588-604
Failure investigation of a tibiotalocalcaneal arthrodesis system
- 1 January 2016
- Published by Elsevier in Engineering Failure Analysis
- Vol. 59, 588-604
Failure investigation of a tibiotalocalcaneal arthrodesis system
- 1 April 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 44, 202-223
Wear characteristics of WSU total ankle replacement devices under shear and torsion loads
- 1 April 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 44, 202-223
Wear characteristics of WSU total ankle replacement devices under shear and torsion loads
- 1 September 2014
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 12 (3) , 193-202
Thermal Isotherms in PMMA and Cell Necrosis during Total Hip Arthroplasty
Background: Polymethylmethacrylate (PMMA), also known as bone cement, is a commonly used adhesive material to fix implants in Total Hip Arthroplasty (THA). During implantation, bone cement undergoes a polymerization reaction which is an exothermic reaction and results in the release of heat to the surrounding bone tissue, which ultimately leads to thermal necrosis. Necrosis in the bony tissue results in early loosening of the implant, which causes pain and reduces the life of the implant. Purpose: The main objective of the present study was to understand the thermal isotherms in PMMA and to determine the optimal cement mantle thickness to prevent cell necrosis during THA. Methods: In this study, the environment in the bony tissue during implantation was simulated by constructing 3D solid models to observe the temperature distribution in the bony tissue at different cement mantle thicknesses (1 mm, 3 mm and 5 mm), by applying the temperature conditions that exist during the surgery. Stems made with Co-Cr-Mo, 316L stainless steel and Ti6Al4V were used, which acted as heat sinks, and a thermal damage equation was used to measure the bone damage. FEA was conducted based on temperature conditions and thermal isotherms at different cement mantle thicknesses were obtained. Results: Thermal isotherms derived with respect to distance in the bony tissue from the center of the cement mantle, and cell necrosis was determined at different mantle thicknesses. Based on the deduced results, cement mantle thickness of 1-5 mm does not cause thermal damage in the bony tissue. Conclusion: Considering the long term stability of the implant, cement mantle thickness range from 3 mm-5 mm was found to be optimal in THA to prevent cell necrosis.
- 1 September 2014
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 12 (3) , 193-202
Thermal Isotherms in PMMA and Cell Necrosis during Total Hip Arthroplasty
Background: Polymethylmethacrylate (PMMA), also known as bone cement, is a commonly used adhesive material to fix implants in Total Hip Arthroplasty (THA). During implantation, bone cement undergoes a polymerization reaction which is an exothermic reaction and results in the release of heat to the surrounding bone tissue, which ultimately leads to thermal necrosis. Necrosis in the bony tissue results in early loosening of the implant, which causes pain and reduces the life of the implant. Purpose: The main objective of the present study was to understand the thermal isotherms in PMMA and to determine the optimal cement mantle thickness to prevent cell necrosis during THA. Methods: In this study, the environment in the bony tissue during implantation was simulated by constructing 3D solid models to observe the temperature distribution in the bony tissue at different cement mantle thicknesses (1 mm, 3 mm and 5 mm), by applying the temperature conditions that exist during the surgery. Stems made with Co-Cr-Mo, 316L stainless steel and Ti6Al4V were used, which acted as heat sinks, and a thermal damage equation was used to measure the bone damage. FEA was conducted based on temperature conditions and thermal isotherms at different cement mantle thicknesses were obtained. Results: Thermal isotherms derived with respect to distance in the bony tissue from the center of the cement mantle, and cell necrosis was determined at different mantle thicknesses. Based on the deduced results, cement mantle thickness of 1-5 mm does not cause thermal damage in the bony tissue. Conclusion: Considering the long term stability of the implant, cement mantle thickness range from 3 mm-5 mm was found to be optimal in THA to prevent cell necrosis.
- 1 June 2014
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 34, 134-145
Finite element analysis of stress and wear characterization in total ankle replacements
- 1 June 2014
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 34, 134-145
Finite element analysis of stress and wear characterization in total ankle replacements
- Open Access
- 1 April 2012
- Published by Taylor & Francis in Biomatter
- Vol. 2 (2) , 87-93
Effect of cement fill ratio in loosening of hip implants
Femoral loosening is one of the most prevalent causes of revision orthopedic surgeries. Cement mantle thickness has been directly correlated with femoral loosening. If the mantle is too thick, ther...
- 1 April 2012
- Published by Taylor & Francis in Biomatter
- Vol. 2 (2) , 87-93
Open AccessEffect of cement fill ratio in loosening of hip implants
Femoral loosening is one of the most prevalent causes of revision orthopedic surgeries. Cement mantle thickness has been directly correlated with femoral loosening. If the mantle is too thick, ther...