M. V. Ramana Murthy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
M. V. Ramana Murthy has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Dilli Balaji
Natl Inst Ocean Technol, Ocean Struct Dept, Chennai, Tamil Nadu, India
5 shared publications - Dhinesh Ganapathi
Natl Inst Ocean Technol, Ocean Struct Dept, Chennai, Tamil Nadu, India
2 shared publications - Ramalingam Velraj
Institute for Energy Studies, Anna University, Chennai, India
2 shared publications - S. V. S. Phani Kumar
Natl Inst Ocean Technol, Ocean Struct Dept, Chennai, Tamil Nadu, India
2 shared publications A. S. Kiran
Minist Earth Sci, Natl Inst Ocean Technol, Chennai 600100, Tamil Nadu, India
1 shared publication- A. S. Kiran
National Institute of Ocean Technology
1 shared publication
Latest Publications
- Open Access
- 1 May 2021
- Published by Elsevier in Desalination and Water Treatment
- Vol. 222, 36-46
Experimental study on the deaeration process of low temperature thermal desalination plant
- 1 May 2021
- Published by Elsevier in Desalination and Water Treatment
- Vol. 222, 36-46
Open AccessExperimental study on the deaeration process of low temperature thermal desalination plant
- Open Access
- 1 January 2021
- Published by Elsevier in Desalination and Water Treatment
- Vol. 210, 31-43
Numerical studies on the heat transfer characteristics of falling film evaporation on a horizontal elliptical tube for seawater desalination
- 1 January 2021
- Published by Elsevier in Desalination and Water Treatment
- Vol. 210, 31-43
Open AccessNumerical studies on the heat transfer characteristics of falling film evaporation on a horizontal elliptical tube for seawater desalination
- 10 June 2020
- Published by Current Science Association in Current Science
- Vol. 118 (11) , 1768-1773
Shore Protection Measures along Indian Coast – Design to Implementation Based on Two Case Studies
- 10 June 2020
- Published by Current Science Association in Current Science
- Vol. 118 (11) , 1768-1773
Shore Protection Measures along Indian Coast – Design to Implementation Based on Two Case Studies
- 27 September 2019
- Published by Wiley in Journal of Heat Transfer
- Vol. 141 (11)
Numerical Investigation on the Effect of Tube Geometry and Feeder Height on the Heat Transfer Performance of Horizontal Tube Falling Film Evaporation
This paper discusses about the effect of tube geometry and liquid feeder height on the heat transfer performance of falling film evaporation over the horizontal heated plain tubes. To investigate this, a two-dimensional computational fluid dynamics (CFD) model was developed, compared, and validated with published data available in the literature. A numerical simulation was carried out for varying liquid load, tube diameter, liquid feeder height, and corresponding changes in the heat transfer co-efficient (HTC), and mass transfer rate was recorded and analyzed. An attempt was also made to measure the thickness of the film around the tubes from the simulation model. Mechanisms that control the factors such as HTC, film thickness, and mass transfer were numerically investigated and discussed in this work. Numerical results indicated that low value of liquid film thickness appears approximately at the angular position of the range between 90 deg and 125 deg. Also the numerical investigation revealed that liquid film thickness decreases and HTC and mass transfer rate increases with the increase of feeder height. No remarkable change in film thickness was observed with increase in the tube diameter. This numerical study also proved that the prediction of thermally developed boundary region on the circumference of the tube could be possible in terms of mass transfer rate. It was also observed from the numerical study that the highest mass transfer rate takes place between the angle 135–165 deg near to the bottom of the tube.
- 27 September 2019
- Published by Wiley in Journal of Heat Transfer
- Vol. 141 (11)
Numerical Investigation on the Effect of Tube Geometry and Feeder Height on the Heat Transfer Performance of Horizontal Tube Falling Film Evaporation
This paper discusses about the effect of tube geometry and liquid feeder height on the heat transfer performance of falling film evaporation over the horizontal heated plain tubes. To investigate this, a two-dimensional computational fluid dynamics (CFD) model was developed, compared, and validated with published data available in the literature. A numerical simulation was carried out for varying liquid load, tube diameter, liquid feeder height, and corresponding changes in the heat transfer co-efficient (HTC), and mass transfer rate was recorded and analyzed. An attempt was also made to measure the thickness of the film around the tubes from the simulation model. Mechanisms that control the factors such as HTC, film thickness, and mass transfer were numerically investigated and discussed in this work. Numerical results indicated that low value of liquid film thickness appears approximately at the angular position of the range between 90 deg and 125 deg. Also the numerical investigation revealed that liquid film thickness decreases and HTC and mass transfer rate increases with the increase of feeder height. No remarkable change in film thickness was observed with increase in the tube diameter. This numerical study also proved that the prediction of thermally developed boundary region on the circumference of the tube could be possible in terms of mass transfer rate. It was also observed from the numerical study that the highest mass transfer rate takes place between the angle 135–165 deg near to the bottom of the tube.
- 20 November 2017
- Published by Springer Nature
- p. 59-74
Origin, Transformation and Measurement of Waves in Ocean
- 20 November 2017
- Published by Springer Nature
- p. 59-74
Origin, Transformation and Measurement of Waves in Ocean
- Open Access
- 19 February 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (55) , 26830-26844
Experimental study on the vacuum load of low-temperature thermal desalination plant
The objective of this paper is to present a methodology to predict vacuum load theoretically and to compare those results with the experimental values for validation especially the non-condensable gas load and escape water vapour load. The primary objective of this paper is to find out the accumulated effect of non-condensable gases on the vacuum load of low-temperature thermal desalination (LTTD) plant. Suggestions to control the NC gas and escape vapour load on the LTTD process were also discussed in this paper. Determination of an exact amount of vacuum load for the plant is significant, since vacuum system alone shares about 31% of total energy demand of the LTTD plant. Load contribution given by the gas mixtures such as escape water vapour, non-condensable gas and air leak in to the system was experimentally measured by conducting suitable experiments in a running plant of 100 m3/d capacity located in the Island of Agatti, UT Lakshadweep group of Islands, India. Study at Kavaratti plant of same capacity showed that the escape vapour rate was equivalent to 0.3% of the freshwater generation rate of the plant, which was used as an input value for Agatti vacuum load calculation for escape vapour rate. On comparison of the experimental results of non-condensable gas release rate of Agatti plant with the published data and predicted values using methodology, an agreement up to 16 and 7.7% was obtained, respectively, under the same operating conditions. Also, an agreement up to 15% was obtained between the experimental results of Agatti plant with that of observed results of Kavaratti for water vapour escape rate from the main process condenser. It was reported in the literature that for MED desalination system, the extraction of vapour from the evaporator unit linked with a removal of 10–20 units of vapour corresponded to every unit mass of NC gases. But in the present study, for the LTTD process, it was measured that the accumulated effect of NC gases for every unit mass resulted in extraction of 1.6 unit mass of vapour (approx) from the process condenser. This low value could be due to low operating temperature range of LTTD process and use of low-temperature deep-sea cooling water from the ocean in the condenser tubes. From calculation, it was noticed that decrease in molecular weight of gas increased the volumetric vacuum load for the same operating conditions and gas mass flow rates. Also, it was observed that the parameters such as operating pressure, duct loss, mass flow rate of feed water influence the total vacuum load of LTTD plant.
- 19 February 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (55) , 26830-26844
Open AccessExperimental study on the vacuum load of low-temperature thermal desalination plant
The objective of this paper is to present a methodology to predict vacuum load theoretically and to compare those results with the experimental values for validation especially the non-condensable gas load and escape water vapour load. The primary objective of this paper is to find out the accumulated effect of non-condensable gases on the vacuum load of low-temperature thermal desalination (LTTD) plant. Suggestions to control the NC gas and escape vapour load on the LTTD process were also discussed in this paper. Determination of an exact amount of vacuum load for the plant is significant, since vacuum system alone shares about 31% of total energy demand of the LTTD plant. Load contribution given by the gas mixtures such as escape water vapour, non-condensable gas and air leak in to the system was experimentally measured by conducting suitable experiments in a running plant of 100 m3/d capacity located in the Island of Agatti, UT Lakshadweep group of Islands, India. Study at Kavaratti plant of same capacity showed that the escape vapour rate was equivalent to 0.3% of the freshwater generation rate of the plant, which was used as an input value for Agatti vacuum load calculation for escape vapour rate. On comparison of the experimental results of non-condensable gas release rate of Agatti plant with the published data and predicted values using methodology, an agreement up to 16 and 7.7% was obtained, respectively, under the same operating conditions. Also, an agreement up to 15% was obtained between the experimental results of Agatti plant with that of observed results of Kavaratti for water vapour escape rate from the main process condenser. It was reported in the literature that for MED desalination system, the extraction of vapour from the evaporator unit linked with a removal of 10–20 units of vapour corresponded to every unit mass of NC gases. But in the present study, for the LTTD process, it was measured that the accumulated effect of NC gases for every unit mass resulted in extraction of 1.6 unit mass of vapour (approx) from the process condenser. This low value could be due to low operating temperature range of LTTD process and use of low-temperature deep-sea cooling water from the ocean in the condenser tubes. From calculation, it was noticed that decrease in molecular weight of gas increased the volumetric vacuum load for the same operating conditions and gas mass flow rates. Also, it was observed that the parameters such as operating pressure, duct loss, mass flow rate of feed water influence the total vacuum load of LTTD plant.
- Open Access
- 10 February 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (52) , 24705-24715
Water quality improvement studies in LTTD plant
Low-temperature thermal desalination plant (LTTD) is a process which involves evaporation of warm surface seawater at 28–29°C inside a vacuum flash chamber, which is maintained at a subatmospheric pressure of around 24–27 mbar [abs] and the resultant vapor is condensed in the shell and tube heat exchanger using cooling water drawn from deep sea, which is available at 12–13°C. Two configurations have been used to conduct experiments, namely bare spout and elevated demister configuration. During the operation of LTTD plant located at Agatti Island, an increase in the salinity of product water from 110 ppm during low tide to 570 ppm during high tide is observed in the bare spout configuration. Increased tide level leads to increased flood level inside flash chamber. Increased flood level results in reduction in the separation distance between the brine liquid level and the de-mister. As a result, the salinity level of product water is increased beyond an acceptable limit. In order to bring down the salinity level, a modification is performed on the geometry of the spout pipe and elevation of demister inside flash chamber which is named as elevated demister configuration. The mechanism, which improves water quality by implementing elevated demister configuration and drawbacks of bare spout configuration are discussed in this paper. Necessary experiments are conducted for studying the effect of both the configurations on the product quality. Results based on the experimental studies show a significant improvement in the water quality ranging from 4 to 45 ppm between low and high tides when implementing the elevated demister configuration.
- 10 February 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (52) , 24705-24715
Open AccessWater quality improvement studies in LTTD plant
Low-temperature thermal desalination plant (LTTD) is a process which involves evaporation of warm surface seawater at 28–29°C inside a vacuum flash chamber, which is maintained at a subatmospheric pressure of around 24–27 mbar [abs] and the resultant vapor is condensed in the shell and tube heat exchanger using cooling water drawn from deep sea, which is available at 12–13°C. Two configurations have been used to conduct experiments, namely bare spout and elevated demister configuration. During the operation of LTTD plant located at Agatti Island, an increase in the salinity of product water from 110 ppm during low tide to 570 ppm during high tide is observed in the bare spout configuration. Increased tide level leads to increased flood level inside flash chamber. Increased flood level results in reduction in the separation distance between the brine liquid level and the de-mister. As a result, the salinity level of product water is increased beyond an acceptable limit. In order to bring down the salinity level, a modification is performed on the geometry of the spout pipe and elevation of demister inside flash chamber which is named as elevated demister configuration. The mechanism, which improves water quality by implementing elevated demister configuration and drawbacks of bare spout configuration are discussed in this paper. Necessary experiments are conducted for studying the effect of both the configurations on the product quality. Results based on the experimental studies show a significant improvement in the water quality ranging from 4 to 45 ppm between low and high tides when implementing the elevated demister configuration.
- 1 January 2015
- Published by Springer Nature
- p. 333-347
Mathematical Model Study of the Effluent Disposal from a Desalination Plant in the Marine Environment at Tuticorin, India
- 1 January 2015
- Published by Springer Nature
- p. 333-347
Mathematical Model Study of the Effluent Disposal from a Desalination Plant in the Marine Environment at Tuticorin, India
- Open Access
- 1 September 2014
- Published by SAGE Publications in The International Journal of Ocean and Climate Systems
- Vol. 5 (3) , 163-173
Assessment of Feasibility of Suction Pile/Anchor Installation and Pullout Testing through Field Tests
Suction pile anchors are large cylindrical (inverted bucket type structure) open at the bottom and closed at the top and largely used for mooring of offshore platforms, exploratory vessels etc. Prediction of the mooring capacity of suction piles is a critical issue faced by the design engineers and rational methods are required to produce reliable designs. Tests have been conducted in an existing natural pond within NIOT campus with the objective of developing methodology of deployment, design and logistics for suction pile installation and testing of mooring capacity under static pullout. Small size suction piles with varying diameters and lengths have been used in the tests. The tests have been carried out in the natural pond with constant water depth of 1.5 m with the top 1.5 m layer of bed comprising soft marine clay. It is found that pile geometry, aspect ratio and angle of pullout have a significant influence on the response to pullout. As angle of mooring load application changes from vertical to horizontal the reaction offered by the suction pile changes from skin friction to passive soil resistance. Resistance offered by the internal plug of soil is found to vary according to dimension of the anchor piles.
- 1 September 2014
- Published by SAGE Publications in The International Journal of Ocean and Climate Systems
- Vol. 5 (3) , 163-173
Open AccessAssessment of Feasibility of Suction Pile/Anchor Installation and Pullout Testing through Field Tests
Suction pile anchors are large cylindrical (inverted bucket type structure) open at the bottom and closed at the top and largely used for mooring of offshore platforms, exploratory vessels etc. Prediction of the mooring capacity of suction piles is a critical issue faced by the design engineers and rational methods are required to produce reliable designs. Tests have been conducted in an existing natural pond within NIOT campus with the objective of developing methodology of deployment, design and logistics for suction pile installation and testing of mooring capacity under static pullout. Small size suction piles with varying diameters and lengths have been used in the tests. The tests have been carried out in the natural pond with constant water depth of 1.5 m with the top 1.5 m layer of bed comprising soft marine clay. It is found that pile geometry, aspect ratio and angle of pullout have a significant influence on the response to pullout. As angle of mooring load application changes from vertical to horizontal the reaction offered by the suction pile changes from skin friction to passive soil resistance. Resistance offered by the internal plug of soil is found to vary according to dimension of the anchor piles.