Nichole Korpi-Steiner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nichole Korpi-Steiner has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
A K Saenger
University of Minnesota, Minneapolis, MN, United States
1 shared publicationAndres Schanzer
Department of Surgery, UMass Memorial Medical Center, Worcester, MA
1 shared publicationDabcc
From the Department of Pathology and Laboratory Medicine, University of North Carolina, Chapel Hill, NC
1 shared publicationDenise Milhorn
Department of Pathology and Laboratory Medicine, University of North Carolina, Chapel Hill, NC, USA
1 shared publicationFacb
From the Department of Pathology and Laboratory Medicine, University of North Carolina, Chapel Hill, NC
1 shared publicationGlenn E Palomaki
Department of Pathology and Laboratory Medicine, Women & Infants Hospital/Alpert Medical School at Brown University, Providence, RI
1 shared publication
Latest Publications
- 1 January 2020
- Published by Elsevier in Clinical Biochemistry
- Vol. 75, 53-61
Characterization of biotin interference in 21 Vitros 5600 immunoassays and risk mitigation for patient safety at a large academic medical center
- 1 January 2020
- Published by Elsevier in Clinical Biochemistry
- Vol. 75, 53-61
Characterization of biotin interference in 21 Vitros 5600 immunoassays and risk mitigation for patient safety at a large academic medical center
- 1 November 2017
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 2 (3) , 356-366
Comparison of Point-of-Care Activated Clotting Time Methods in Different Clinical Settings in a Large Academic Medical Center
Objectives: This study is a comparative analysis of measured activated clotting time (ACT) values by use of 5 different point-of-care (POC) ACT methods spanning the range detected during different clinical procedures at our institution. Methods: We determined the correlation, imprecision, and differences in measured ACT values with use of 4 POC ACT methods compared with a reference ACT method in 41 venous whole blood samples collected from 25 adult patients undergoing interventional procedures. The POC ACT methods evaluated included the i-STAT with kaolin activator in prewarm mode, i-STAT with Celite activator in prewarm and nonprewarm modes, ACTPlus, and HMSPlus, which was designated the reference method. Each venous whole blood patient sample was tested in duplicate on each POC ACT test system (total n = 410 ACT measurements). Analyses of imprecision and differences in measured ACT values were stratified by moderate (100–299 s) and high (≥300 s) ACT ranges. Results: In this study population, measured ACT values ranged from 100–835 s with use of the HMSPlus. All methods demonstrated good correlation (r ≥ 0.95) in ACT values compared to the reference method. Imprecision varied by method with ranges of 1.7%–2.7% CV in the moderate ACT range and 2.5%–4.8% CV in the high ACT range. ACTPlus and i-STAT-Celite-prewarm methods exhibited proportional differences in measured ACT values whereas the i-STAT-Celite-nonprewarm and i-STAT-kaolin-prewarm demonstrated constant differences in measured ACT values compared to HMSPlus. Conclusions: ACT values correlate well between POC methods. Imprecision and difference profiles vary by method; notably, imprecision exceeds systematic differences in the high ACT range and contributes to intermethod differences that are limitations worthy of consideration when contemplating a change in ACT methods.
- 1 November 2017
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 2 (3) , 356-366
Comparison of Point-of-Care Activated Clotting Time Methods in Different Clinical Settings in a Large Academic Medical Center
Objectives: This study is a comparative analysis of measured activated clotting time (ACT) values by use of 5 different point-of-care (POC) ACT methods spanning the range detected during different clinical procedures at our institution. Methods: We determined the correlation, imprecision, and differences in measured ACT values with use of 4 POC ACT methods compared with a reference ACT method in 41 venous whole blood samples collected from 25 adult patients undergoing interventional procedures. The POC ACT methods evaluated included the i-STAT with kaolin activator in prewarm mode, i-STAT with Celite activator in prewarm and nonprewarm modes, ACTPlus, and HMSPlus, which was designated the reference method. Each venous whole blood patient sample was tested in duplicate on each POC ACT test system (total n = 410 ACT measurements). Analyses of imprecision and differences in measured ACT values were stratified by moderate (100–299 s) and high (≥300 s) ACT ranges. Results: In this study population, measured ACT values ranged from 100–835 s with use of the HMSPlus. All methods demonstrated good correlation (r ≥ 0.95) in ACT values compared to the reference method. Imprecision varied by method with ranges of 1.7%–2.7% CV in the moderate ACT range and 2.5%–4.8% CV in the high ACT range. ACTPlus and i-STAT-Celite-prewarm methods exhibited proportional differences in measured ACT values whereas the i-STAT-Celite-nonprewarm and i-STAT-kaolin-prewarm demonstrated constant differences in measured ACT values compared to HMSPlus. Conclusions: ACT values correlate well between POC methods. Imprecision and difference profiles vary by method; notably, imprecision exceeds systematic differences in the high ACT range and contributes to intermethod differences that are limitations worthy of consideration when contemplating a change in ACT methods.
- Open Access
- 1 May 2017
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 63 (5) , 946-953
Emerging Considerations for Noninvasive Prenatal Testing
Approaches to prenatal screening for common fetal chromosomal aneuploidies are undergoing a dynamic transformation in response to a greater understanding surrou
- 1 May 2017
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 63 (5) , 946-953
Open AccessEmerging Considerations for Noninvasive Prenatal Testing
Approaches to prenatal screening for common fetal chromosomal aneuploidies are undergoing a dynamic transformation in response to a greater understanding surrou
- 1 January 2017
- Published by Elsevier
- Vol. 78, 1-58
Advances in Cardiac Biomarkers of Acute Coronary Syndrome
- 1 January 2017
- Published by Elsevier
- Vol. 78, 1-58
Advances in Cardiac Biomarkers of Acute Coronary Syndrome
- Open Access
- 1 September 2016
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 62 (9) , 1285-1286
Bayesian Inference Dilemma in Medical Decision-Making: A Need for User-Friendly Probabilistic Reasoning Tools
The struggle with uncertainty among healthcare professionals about how to apply test results for risk stratification and diagnosis of patients was recently highlighted as a serious risk factor for diagnostic and medical decision-making errors in the 2015 Institute of Medicine (IOM) report Improving Diagnosis in Health Care (1). The Bayes theorem is well recognized by trainees and caregivers as a statistical key for updating the probability of a patient event (e.g., disease) occurring as test result(s) become available, with consideration of the clinical performance characteristics (i.e., clinical sensitivity and specificity) of a test in the clinical context (i.e., prevalence of disease/health in a reference population). However, many trainees and caregivers struggle with the application of Bayes' theorem in clinical practice, suggesting a longstanding educational gap that can negatively impact medical decision-making and patient care. The IOM …
- 1 September 2016
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 62 (9) , 1285-1286
Open AccessBayesian Inference Dilemma in Medical Decision-Making: A Need for User-Friendly Probabilistic Reasoning Tools
The struggle with uncertainty among healthcare professionals about how to apply test results for risk stratification and diagnosis of patients was recently highlighted as a serious risk factor for diagnostic and medical decision-making errors in the 2015 Institute of Medicine (IOM) report Improving Diagnosis in Health Care (1). The Bayes theorem is well recognized by trainees and caregivers as a statistical key for updating the probability of a patient event (e.g., disease) occurring as test result(s) become available, with consideration of the clinical performance characteristics (i.e., clinical sensitivity and specificity) of a test in the clinical context (i.e., prevalence of disease/health in a reference population). However, many trainees and caregivers struggle with the application of Bayes' theorem in clinical practice, suggesting a longstanding educational gap that can negatively impact medical decision-making and patient care. The IOM …
- 1 February 2015
- Published by Elsevier in Clinical Biochemistry
- Vol. 48 (3) , 99-104
Using a simulation model to assess risk of false negative point-of-care urinary human chorionic gonadotropin device results due to high-dose hook interference
- 1 February 2015
- Published by Elsevier in Clinical Biochemistry
- Vol. 48 (3) , 99-104
Using a simulation model to assess risk of false negative point-of-care urinary human chorionic gonadotropin device results due to high-dose hook interference
- 1 September 2014
- Published by Wolters Kluwer Health in Point of Care: The Journal of Near-Patient Testing & Technology
- Vol. 13 (3) , 94-96
Tightening Glucose Meter Performance Criteria and Disinfection Practice
- 1 September 2014
- Published by Wolters Kluwer Health in Point of Care: The Journal of Near-Patient Testing & Technology
- Vol. 13 (3) , 94-96
Tightening Glucose Meter Performance Criteria and Disinfection Practice
- Open Access
- 1 February 2014
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 60 (2) , 427
Be-(a)-ware of the Red Flags: Common Flaws of Nonreproducible Preclinical Research Studies
- 1 February 2014
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 60 (2) , 427
Open AccessBe-(a)-ware of the Red Flags: Common Flaws of Nonreproducible Preclinical Research Studies