M. Ya. Schelev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
M. Ya. Schelev has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
V. I. Lozovoi
Russian Academy of Sciences
3 shared publicationsA. V. Smirnov
Russian Academy of Sciences
2 shared publicationsE. V. Shashkov
Russian Academy of Sciences
2 shared publicationsG. P. Levina
Russian Academy of Sciences
2 shared publications- O. I. Meshkov
Novosibirsk State University, Novosibirsk, Russia
2 shared publications P. B. Gornostaev
Russian Academy of Sciences
2 shared publications
Latest Publications
- 28 September 2016
- Published by IOP Publishing in Quantum Electronics
- Vol. 46 (9) , 860-862
Recording Vavilov–Cherenkov radiation in a linear accelerator using a picosecond streak camera
- 28 September 2016
- Published by IOP Publishing in Quantum Electronics
- Vol. 46 (9) , 860-862
Recording Vavilov–Cherenkov radiation in a linear accelerator using a picosecond streak camera
- 31 January 2015
- Published by Allerton Press in Bulletin of the Lebedev Physics Institute
- Vol. 42 (1) , 7-9
On the decay time of luminescent screens of picosecond image tubes when measuring repeated signals in the accumulation mode
When replacing the conventional “slow” luminescent screens (P20, P43) in picosecond image tubes by the “fast” ones (P46, P47), we found an increase in the decay time of “fast” cathodoluminophors (by a factor of 2–5) with increasing the number (from one to a hundred) of measured pulses. The consideration of the detected effect makes it possible to correct the problem statement in developing picosecond dissectors for recording repeated signals in the accumulation mode (e.g., synchrotron radiation).
- 31 January 2015
- Published by Allerton Press in Bulletin of the Lebedev Physics Institute
- Vol. 42 (1) , 7-9
On the decay time of luminescent screens of picosecond image tubes when measuring repeated signals in the accumulation mode
When replacing the conventional “slow” luminescent screens (P20, P43) in picosecond image tubes by the “fast” ones (P46, P47), we found an increase in the decay time of “fast” cathodoluminophors (by a factor of 2–5) with increasing the number (from one to a hundred) of measured pulses. The consideration of the detected effect makes it possible to correct the problem statement in developing picosecond dissectors for recording repeated signals in the accumulation mode (e.g., synchrotron radiation).
- 21 November 2014
- Published by Springer Nature in Journal of Russian Laser Research
- Vol. 35 (6) , 617-622
Laser Diagnostics of Picosecond Streak Tubes Supplied with Fast-Response Phosphor Screens
- 21 November 2014
- Published by Springer Nature in Journal of Russian Laser Research
- Vol. 35 (6) , 617-622
Laser Diagnostics of Picosecond Streak Tubes Supplied with Fast-Response Phosphor Screens
- Open Access
- 1 January 2012
- Published by Uspekhi Fizicheskikh Nauk (UFN) Journal in Uspekhi Fizicheskih Nauk
- Vol. 182 (6) , 649-656
Pico-femto-attosecond photoelectronics: looking through the lens of half a century
????-?????-????????????? ??????????????? (?????? ????? ??????????? "???? ???????"), ????? ?.?.
- 1 January 2012
- Published by Uspekhi Fizicheskikh Nauk (UFN) Journal in Uspekhi Fizicheskih Nauk
- Vol. 182 (6) , 649-656
Open AccessPico-femto-attosecond photoelectronics: looking through the lens of half a century
????-?????-????????????? ??????????????? (?????? ????? ??????????? "???? ???????"), ????? ?.?.
- 28 November 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7126
New computer modeling and experimental results on photoelectron gun with time-dependent electric field
Presented are the recent, numerically-supported experimental results on temporal compressing of electron bunch in timedependent electric field, derived with the use of a unique photoelectron gun that has been simulated, designed, manufactured, and tested at the Photoelectronics Department of A.M. Prokhorov General Physics Institute, RAS. An original photoelectron bunch generated from the photocathode by a 7 ps laser pulse was compressed down to ~fs. The future prospects of temporal compressing of electron bunch in time-dependent fields are discussed.
- 28 November 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7126
New computer modeling and experimental results on photoelectron gun with time-dependent electric field
Presented are the recent, numerically-supported experimental results on temporal compressing of electron bunch in timedependent electric field, derived with the use of a unique photoelectron gun that has been simulated, designed, manufactured, and tested at the Photoelectronics Department of A.M. Prokhorov General Physics Institute, RAS. An original photoelectron bunch generated from the photocathode by a 7 ps laser pulse was compressed down to ~fs. The future prospects of temporal compressing of electron bunch in time-dependent fields are discussed.
- 26 January 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6279, 62797N
The granulated gold-film-based semitransparent photocathodes in the visible spectrum range for femtosecond time-resolution experiments
Developed is the granulated, Au film-based, semitransparent photocathode consisting of spherical Au nanoparticles. The granulated Au films are activated by a thin layer of cesium and oxygen of about two monolayer thicknesses to decrease the work function down to about 1 eV and gain the photoemission effect in the visible spectrum range. The sensitivity maximum equal to about one mA/W is located in the green spectrum range. The nanoparticles formation and photocathode surface structure are studied with the use of the X-ray photoelectron spectroscopy technique. Those studies have shown that the photoemission effect in the wavelength range &lgr;> 450 nm is conditioned by excitation of the surface plasmons in quasi-spherical Au nanoparticles. This has allowed manufacturing of a streak tube with the introducible, Au nanoparticles-based photocathode, stability of which has been remaining invariant.
- 26 January 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6279, 62797N
The granulated gold-film-based semitransparent photocathodes in the visible spectrum range for femtosecond time-resolution experiments
Developed is the granulated, Au film-based, semitransparent photocathode consisting of spherical Au nanoparticles. The granulated Au films are activated by a thin layer of cesium and oxygen of about two monolayer thicknesses to decrease the work function down to about 1 eV and gain the photoemission effect in the visible spectrum range. The sensitivity maximum equal to about one mA/W is located in the green spectrum range. The nanoparticles formation and photocathode surface structure are studied with the use of the X-ray photoelectron spectroscopy technique. Those studies have shown that the photoemission effect in the wavelength range &lgr;> 450 nm is conditioned by excitation of the surface plasmons in quasi-spherical Au nanoparticles. This has allowed manufacturing of a streak tube with the introducible, Au nanoparticles-based photocathode, stability of which has been remaining invariant.
- 1 January 2005
- Published by Institution of Engineering and Technology (IET)
- p. v6:39
Fast optical discharge propagation through optical fibres under kW-range laser radiation
The fast mode of optical discharge propagation in optical fibres has been discovered. In contrast to the known fibre fuse effect such optical discharge propagation is accompanied by fibre cracks and velocity reaches = 3 km/s under the intensity ≈40 W/m2. (2 pages)
- 1 January 2005
- Published by Institution of Engineering and Technology (IET)
- p. v6:39
Fast optical discharge propagation through optical fibres under kW-range laser radiation
The fast mode of optical discharge propagation in optical fibres has been discovered. In contrast to the known fibre fuse effect such optical discharge propagation is accompanied by fibre cracks and velocity reaches = 3 km/s under the intensity ≈40 W/m2. (2 pages)