TFTakuya Furuta

Takuya Furuta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takuya Furuta has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Toward AI-agent-driven particle transport simulations: implementation of AI-assisted workflows for PHITS

    by Tatsuhiko Sato, Shintaro Hashimoto, Tatsuhiko Ogawa, Takuya Furuta, Yuho Hirata, Seiki Ohnishi, Yasuhito Sakaki, Nobuhiro Shigyo

  • Integration of a dose-voxel kernel (DVK) convolution method for voxel-based dosimetry in Particle and Heavy Ion Transport code System (PHITS)

    by Shalaine Sana Tatu, Tatsuhiko Sato, Takuya Furuta, Yin How Wong, Azahari Kasbollah, Subapriya Suppiah, Chai Hong Yeong

    Objective . Dose-voxel kernel (DVK) convolution provides a physics-based approach for absorbed-dose calculation from nuclear medicine imaging. This study implemented DVK convolution within the particle and heavy ion transport code system (PHITS) and evaluated its performance against Monte Carlo (MC) simulations and clinical dosimetry methods. Approach . Five post-radioembolization 90 Y bremsstrahlung single photon emission computed tomography/computed tomography (SPECT/CT) and positron emission tomography/CT (PET/CT) datasets from the University of Michigan Deep Blue Data repository were converted into PHITS-readable formats using the radiotherapy package based on PHITS. Activity distributions were mapped onto CT voxel grids, and DVKs were generated for 24 human tissue materials. A new DVK mode was implemented in PHITS to calculate voxel-wise absorbed-dose rates by convolving tissue-specific DVKs with activity distributions. Performance was evaluated against MC simulations using gamma index analysis, mean absorbed-dose rates within volumes of interests (VOIs), and voxel-wise absorbed-dose differences in liver, lung, and liver–lung interface regions. VOI-based mean absorbed doses were further benchmarked against the local deposition model (LDM) and voxel S -value (VSV) convolution in MIM Software (v7.4.3). Main results . Following one-time DVK generation, DVK mode calculations required ∼40 s compared with >9 h for high-statistics MC simulations. Gamma pass fractions ranged from 92.1%–99.9%, while mean DVK–MC differences in VOI-based dose rates were −1.2 ± 2.9% (SPECT/CT) and −1.0 ± 4.3% (PET/CT). Voxel-wise dose differences showed good agreement between DVK and MC in homogeneous liver tissue, while lung regions exhibited lower absorbed-dose estimates and the liver–lung interface showed increased variability, ( P 95 up to 39%). Compared with MIM, VOI-based dose differences were 9.7 ± 7.2% for SPECT/CT (LDM-based) and −0.1 ± 8.4% for PET/CT (VSV-based). Significance . The PHITS-integrated DVK implementation enables efficient voxel-based dosimetry while maintaining close agreement with high-statistics MC simulations. This framework provides a practical physics-based approach for patient-specific radiopharmaceutical therapy dosimetry.

  • Open Access

    Overview of PHITS Ver.3.34 with particular focus on track-structure calculation

    by Tatsuhiko Ogawa, Yuho Hirata, Yusuke Matsuya, Takeshi Kai, Tatsuhiko Sato, Yosuke Iwamoto, Shintaro Hashimoto, Takuya Furuta, Shin-Ichiro Abe, Norihiro Matsuda, et al.

    This paper presents the latest updates on PHITS, a versatile radiation transport code, focusing specifically on track-structure models. Track structure calculations are methods used to simulate the movement of charged particles while explicitly considering each atomic reaction. Initially developed for radiation biology, these calculation methods aimed to analyze the radiation-induced damage to DNA and chromosomes. Several track-structure calculation models, including PHITS-ETS, PHITS-ETS for Si, PHITS-KURBUC, ETSART, and ITSART, have been developed and implemented for PHITS. These models allow users to study the behavior of various particles at the nano-scale across a wide range of materials. Furthermore, potential applications of track-structure calculations have also been proposed so far. This collection of track-structure calculation models, which encompasses diverse conditions, opens up new avenues for research in the field of radiation effects.


  • Open Access

    Construction of new polygon mesh-type phantoms based on adult Japanese voxel phantoms

    by Kaoru Sato, Takuya Furuta, Daiki Satoh, Shuichi Tsuda

    To construct adult Japanese phantoms applicable to individual exposure dose assessments, we created adult Japanese polygon mesh-type male (JPM) and female (JPF) phantoms through modification of the adult Japanese voxel phantoms, JM-103 (male) and JF-103 (female). The body sizes and masses of organs, tissues, and organ contents in JPM and JPF were adjusted to the Japanese averages, except for those unimportant for radiation protection or risks. The JPM and JPF data were converted to tetrahedral mesh-type data and incorporated into the Particle and Heavy Ion Transport code System (PHITS) for dose calculations. The dosimetric characteristics of the JPM and JPF phantoms were validated by calculating their effective doses in the anterior–posterior geometry for the external irradiation of photons with energies of 0.01–20 MeV and compared with those of JM-103 and JF-103 or the reference values given in ICRP Publication 116. The results confirmed no problems applying JPM and JPF to dose assessments in adult Japanese subjects. Furthermore, it was found that JPM and JPF can also accurately calculate the absorbed doses for entire organs and high radiosensitive cell regions with thin, small, and complicated structures.

  • Top Cited Papers
    Open Access

    Recent improvements of the particle and heavy ion transport code system – PHITS version 3.33

    by Tatsuhiko Sato, Yosuke Iwamoto, Shintaro Hashimoto, Tatsuhiko Ogawa, Takuya Furuta, Shin-Ichiro Abe, Takeshi Kai, Yusuke Matsuya, Norihiro Matsuda, Yuho Hirata, et al.


  • Development of the DICOM-based Monte Carlo dose reconstruction system for a retrospective study on the secondary cancer risk in carbon ion radiotherapy

    by Takuya Furuta, Yusuke Koba, Shintaro Hashimoto, Weishan Chang, Shunsuke Yonai, Shinnosuke Matsumoto, Akihisa Ishikawa, Tatsuhiko Sato

    Objective. A retrospective study on secondary cancer risk on carbon ion radiotherapy (CIRT) is ongoing at the Heavy Ion Medical Accelerator in Chiba (HIMAC). The reconstruction of the whole-body patient dose distribution is the key issue in the study because dose distribution only around the planning target volume was evaluated in the treatment planning system. Approach. We therefore developed a new dose reconstruction system based on the Particle and Heavy Ion Transport code System (PHITS) coupled with the treatment plan DICOM data set by extending the functionalities of RadioTherapy package based on PHITS (RT-PHITS). In the system, the geometry of patient-specific beam devices such as the range shifter, range compensator, and collimators as well as the individual patient’s body are automatically reconstructed. Various functions useful for retrospective analysis on the CIRT are implemented in the system, such as those for separately deducing dose contributions from different secondary particles and their origins. Main results. The accuracy of the developed system was validated by comparing the dose distribution to the experimental data measured in a water tank and using a treatment plan on an anthropomorphic phantom. Significance. The extended RT-PHITS will be used in epidemiological studies based on clinical data from HIMAC.


  • Influence of distant scatterer on air kerma measurement in the evaluation of diagnostic X-rays using Monte Carlo simulation

    by Masahide Tominaga, Yukari Nagayasu, Motoharu Sasaki, Takuya Furuta, Hiroaki Hayashi, Masataka Oita, Yuichi Nishiyama, Akihiro Haga

    The evaluation of the entrance surface dose (ESD) ensures safe radiation doses for X-ray imaging patients. The air kerma free-in-air value used to estimate ESD may be affected by those X-rays that scatter from the scatterer placed behind the chamber at the time of measurement, thereby leading to assessment errors. Therefore, the influence of scattered radiation on air kerma measurements was investigated. Monte Carlo simulations were performed for various detector-to-scatterer distances and scatterer materials. The simulation results were compared with actual measurements to confirm the simulation accuracy. The source–chamber distance was set to 50 and 100 cm for the experimental measurements and simulation, respectively, and the chamber–scatterer distance was varied. The Monte Carlo simulation results reproduced the actual measurements with an accuracy of 3.5%. The effect of backscattering varied with the tube voltage and irradiation field size. The effect was observed in the order of prominence for the following scatterer materials: water-equivalent phantom, acrylic, concrete, lead, and iron. Furthermore, this effect decreased exponentially with increasing chamber–scatterer distance. For a field size of 10 × 10 cm2, the finite-distance backscatter factor decreased with an increasing chamber–scatterer distance for all materials. The cause of backscattering in diagnostic X-ray energy regions differs depending on the scatterer material, as well as the photon energy and field size. Backscattering decreases exponentially as the distance between the detector and scatterer increases.


  • Open Access

    Medical application of particle and heavy ion transport code system PHITS

    by Takuya Furuta, Tatsuhiko Sato

    The Particle and Heavy Ion Transport code System (PHITS) is a general-purpose Monte Carlo simulation code that has been applied in various areas of medical physics. These include application in different types of radiotherapy, shielding calculations, application to radiation biology, and research and development of medical tools. In this article, the useful features of PHITS are explained by referring to actual examples of various medical applications.


  • Re-evaluation of Radiation-Energy Transfer to an Extraction Solvent in a Minor-Actinide-Separation Process Based on Consideration of Radiation Permeability

    by Tomohiro Toigawa, Yasuhiro Tsubata, Takeshi Kai, Takuya Furuta, Yuta Kumagai, Tatsuro Matsumura

    Absorbed-dose estimation is essential for evaluation of the radiation tolerance of minor-actinide-separation processes. We propose a dose-evaluation method based on radiation permeability, with comparisons of heterogeneous structures seen in the solvent-extraction process, such as emulsions forming in the mixture of the organic and aqueous phases. A demonstration of radiation-energy-transfer simulation is performed with a focus on the minor-actinide-recovery process from high-level liquid waste with the aid of the Monte Carlo radiation-transport code PHITS. The simulation results indicate that the dose absorbed by the extraction solvent from alpha radiation depends upon the emulsion structure, and that from beta and gamma radiation depends upon the mixer-settler-apparatus size. Non-negligible contributions of well-permeable gamma rays were indicated in terms of the plant operation of the minor-actinide-separation process.