Michal Oscar Zembala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michal Oscar Zembala has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Krzysztof Filipiak
Department of Cardiac, Vascular and Endovascular Surgery and Transplantology School of Medicine Division of Dentistry in Zabrze Medical University of Silesia Katowice
3 shared publicationsMarian Zembala
Department of Cardiac, Vascular and Endovascular Surgery and Transplantology School of Medicine Division of Dentistry in Zabrze Medical University of Silesia Katowice
3 shared publicationsMariusz Gąsior
3 shared publicationsTomasz Niklewski
Department of Cardiac Surgery and Transplantology, Silesian Center for Heart Diseases, Zabrze, Poland
3 shared publications- Oskar Kowalski
Department of Human Nutrition, Department of Dietetics, Faculty of Health Sciences in Bytom, Medical University of Silesia in Katowice, ul. Jordana 19, 41-808 Zabrze, Poland
2 shared publications - Paweł Nadziakiewicz
Department of Anesthesiology and Intensive Therapy, Silesian Centre for Heart Diseases, Medical University of Silesia, 40-055 Katowice, Poland
2 shared publications
Latest Publications
- Open Access
- 26 September 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (19) , 12206
A Successful Heart Transplantation Coupled with Temporary Right Ventricular Assist Device Implantation in a Patient with (ir)Reversible Pulmonary Hypertension
Pulmonary hypertension (PH) constitutes one of the main contraindications to heart transplantation (OHT), and elevated pulmonary vascular resistance (PVR) is associated with high risk of posttransplant right heart failure (RVF). In the present case report, a patient with PH is introduced who qualified for heart lung transplantation (HLT) and underwent successful OHT with temporary right ventricle assist device (tRVAD) due to the lack of a suitable heart-lung donor. Temporary RVAD support coupled with optimal medical management may help reverse pulmonary vascular resistance, which was previously deemed as permanent in patients requiring heart transplantation.
- 26 September 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (19) , 12206
Open AccessA Successful Heart Transplantation Coupled with Temporary Right Ventricular Assist Device Implantation in a Patient with (ir)Reversible Pulmonary Hypertension
Pulmonary hypertension (PH) constitutes one of the main contraindications to heart transplantation (OHT), and elevated pulmonary vascular resistance (PVR) is associated with high risk of posttransplant right heart failure (RVF). In the present case report, a patient with PH is introduced who qualified for heart lung transplantation (HLT) and underwent successful OHT with temporary right ventricle assist device (tRVAD) due to the lack of a suitable heart-lung donor. Temporary RVAD support coupled with optimal medical management may help reverse pulmonary vascular resistance, which was previously deemed as permanent in patients requiring heart transplantation.
- 1 August 2017
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 59 (4) , e337-e344
Hybrid dual stage closed chest ablation of persistent atrial fibrillation
- 1 August 2017
- Published by Czech Society of Cardiology in Cor et Vasa
- Vol. 59 (4) , e337-e344
Hybrid dual stage closed chest ablation of persistent atrial fibrillation
- Open Access
- 1 January 2017
- Published by Termedia Sp. z.o.o. in Archives of Medical Science
- Vol. 1 (1) , 109-117
Staged hybrid ablation for persistent and longstanding persistent atrial fibrillation effectively restores sinus rhythm in long-term observation
Introduction: Hybrid ablation (HABL) of atrial fibrillation combining endoscopic, minimally invasive, closed chest epicardial ablation with endocardial CARTO-guided accuracy was introduced to overcome the limitations of current therapeutic options for patients with persistent (PSAF) and...
- 1 January 2017
- Published by Termedia Sp. z.o.o. in Archives of Medical Science
- Vol. 1 (1) , 109-117
Open AccessStaged hybrid ablation for persistent and longstanding persistent atrial fibrillation effectively restores sinus rhythm in long-term observation
Introduction: Hybrid ablation (HABL) of atrial fibrillation combining endoscopic, minimally invasive, closed chest epicardial ablation with endocardial CARTO-guided accuracy was introduced to overcome the limitations of current therapeutic options for patients with persistent (PSAF) and...
- 22 March 2016
- Published by Polskie Towarzystwo Kardiologiczne in Polish Heart Journal
- Vol. 74 (3) , 206-212
Symetis Acurate Neo transfemoral aortic bioprosthesis — initial Polish experience
Background: Transcatheter aortic valve implantation (TAVI) has proven to be valuable alternative to conventional surgical aortic valve replacement in high risk and surgically inoperable patients who suffer from severe symptomatic aortic stenosis. With second generation of TAVI devices improvements in both handling and performance are highly demanded. This brief clinical communication reports the first Polish experience with the second generation of transfemoral TAVI device – Symetis Acurate Neo. Methods: From Nov.19th 2014 till Feb. 18th 2015 nine (n=9) patients with severe symptomatic aortic stenosis have been operated on using the Symetis Acurate Neo. Patients were subject to 7-day evaluation and 30-day phone follow-up Results: The procedure was safely and successfully performed in all patients. A SMALL (S) valve (21-23mm equivalent) was used in two pts, MEDIUM (M; 23-25mm equiv) in five and a LARGE (L; 25-26mm equivalent) in two pts. In three cases post-release balloon dilatation was required. There were no intraoperative complications and no major adverse events (as per VARC classification) during initial hospitalization, including conduction or rhythm disturbances. In all cases, a Mean gradient on the prosthetic valves was 7,8mmHg (10,2mmHg on the “S” valves). Rapid improvement in patients’ functional class was noted. Perivalvular leak was evaluated as “mild” in 3 cases, “trace” in one and “not existing” in five. Conclusions: This initial experience with the Symetis Acurate Neo demonstrates its good safety profile and excellent hemodynamics. Low radial stress of the valve results in minimal incidence of AV rhythm disturbances, and sealing crown for nearly non-existing paravalvular leak.
- 22 March 2016
- Published by Polskie Towarzystwo Kardiologiczne in Polish Heart Journal
- Vol. 74 (3) , 206-212
Symetis Acurate Neo transfemoral aortic bioprosthesis — initial Polish experience
Background: Transcatheter aortic valve implantation (TAVI) has proven to be valuable alternative to conventional surgical aortic valve replacement in high risk and surgically inoperable patients who suffer from severe symptomatic aortic stenosis. With second generation of TAVI devices improvements in both handling and performance are highly demanded. This brief clinical communication reports the first Polish experience with the second generation of transfemoral TAVI device – Symetis Acurate Neo. Methods: From Nov.19th 2014 till Feb. 18th 2015 nine (n=9) patients with severe symptomatic aortic stenosis have been operated on using the Symetis Acurate Neo. Patients were subject to 7-day evaluation and 30-day phone follow-up Results: The procedure was safely and successfully performed in all patients. A SMALL (S) valve (21-23mm equivalent) was used in two pts, MEDIUM (M; 23-25mm equiv) in five and a LARGE (L; 25-26mm equivalent) in two pts. In three cases post-release balloon dilatation was required. There were no intraoperative complications and no major adverse events (as per VARC classification) during initial hospitalization, including conduction or rhythm disturbances. In all cases, a Mean gradient on the prosthetic valves was 7,8mmHg (10,2mmHg on the “S” valves). Rapid improvement in patients’ functional class was noted. Perivalvular leak was evaluated as “mild” in 3 cases, “trace” in one and “not existing” in five. Conclusions: This initial experience with the Symetis Acurate Neo demonstrates its good safety profile and excellent hemodynamics. Low radial stress of the valve results in minimal incidence of AV rhythm disturbances, and sealing crown for nearly non-existing paravalvular leak.
- 25 November 2014
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 47 (2) , e75-e76
Intra-aortic balloon clamp for safe resternotomy in a patient with a giant aneurysm of sinuses of Valsalva
Despite advances in surgical techniques and postoperative medical management, the mortality rates for cardiac reoperations remain high. The risk is most commonly associated with failed resternotomy complicated by fatal injury to the myocardium or its structures. This short case report documents the first use of an endoluminal balloon occlusive device in order to prevent aneurysmal sack damage and coronary vessel injury in a patient with a giant aortic aneurysm after failed aortic surgery. The safe aortic occlusion allowed for closed-chest cardioplegia delivery and subsequent aortic unloading, thus facilitating a difficult but uneventful resternotomy.
- 25 November 2014
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 47 (2) , e75-e76
Intra-aortic balloon clamp for safe resternotomy in a patient with a giant aneurysm of sinuses of Valsalva
Despite advances in surgical techniques and postoperative medical management, the mortality rates for cardiac reoperations remain high. The risk is most commonly associated with failed resternotomy complicated by fatal injury to the myocardium or its structures. This short case report documents the first use of an endoluminal balloon occlusive device in order to prevent aneurysmal sack damage and coronary vessel injury in a patient with a giant aortic aneurysm after failed aortic surgery. The safe aortic occlusion allowed for closed-chest cardioplegia delivery and subsequent aortic unloading, thus facilitating a difficult but uneventful resternotomy.